Vertiv™ Liebert® GXT5 UPS
500-3000VA 120V
Intelligent and Efficient UPS for Protection of Your Mission-Critical Applications
Intelligent and Efficient UPS for Protection of Your Mission-Critical Applications
The Vertiv™ Liebert® GXT5 UPS is an online double conversion UPS solution offering premium power outage protection and continuous power conditioning in a compact and flexible rack/tower form factor. The Liebert® GXT5 single-phase UPS operates with high power efficiency, making it ideally suited to protect critical infrastructure in both centralized and edge network applications. Scalable runtime options with matching external battery cabinets offer additional flexibility when extended uninterrupted power is required. Plus, the Liebert GXT5 provides battery health status and replacement date prediction for intelligent battery health management.
The UPS system is easy to deploy and maintain due to its user-friendly LCD interface and remote management capabilities supported by the Vertiv RDU101 communications card, which makes the Liebert GXT5 compatible with Vertiv infrastructure management solutions such as LIFE™ Services, environmental sensors, Vertiv Power Insight, and more. With market-leading efficiency and unity power factor operation, the Liebert GXT5 will meet your critical application needs. Vertiv offers a standard, three-year advanced exchange product warranty.
Liebert® GXT5 Features
Leading UPS Technology
- High output power factor = up to 1.0
- Full-color graphic LCD with gravity sensing orientation
- Individually controllable output power sockets
- External battery cabinets with auto-detection
- Battery health status and replacement date prediction
- Remote management, update, and configuration capabilities
- Optimized thermal management and variable speed fan
Efficient and Green Product
- High efficiency in online mode
- Energy Star 2.0 certified
- Even higher efficiency (up to 98%) in Active ECO mode
- Programmable outlets for power cycling hung equipment and optimum battery usage
- Compliance with Restriction of Hazardous Substances (RoHS) directive and the Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) regulation
Solutions Wide
- Compact rack/tower design
- Broad range of services and extended warranty
- Easy to install, configure and operate
- Vertiv™ RDU101 network communications card with advanced features
- Compatibility with environmental sensors
- Integrated dry-contacts with selectable definition
- Free Vertiv Power Insight management software
- Serial port for out-of-band management with Avocent® serial consoles
- Automatic internal bypass and external maintenance bypass options
How You Benefit from the Vertiv™ Liebert® GXT5 UPS
Designed for high availability
- The higher power factor (0.9 - 1.0) ensures the connection of more loads and IT equipment.
- With individually controlled output receptacles, you can manage power to individual devices without impacting other critical network equipment operation.
- Minimum downtime with hot-swappable, user-replaceable battery modules that can be changed during operation.
- LIFE™ Services enhance uptime and operational efficiency with continuous remote monitoring, expert analysis, and proactive response.
- Automatic self-test.
User-friendly installation and operation
- Easy-to-read, gravity-sensing graphical color display.
- Intuitive user interface for local configuration and management.
- Support for the Vertiv™ suite of remote management tools (Vertiv™ Power Insight, RDU101 network interface card, and serial connectivity support).
- Auto-detection of external battery cabinets enables faster deployment and accurate runtime information.
- Remote UPS firmware upgrade capability ensures the UPS has the latest features and enhancements.
Longer service life and runtime of the batteries
- Extended runtimes with the addition of external battery cabinets.
- Improved battery care through temperature-compensated battery charging.
- Intelligent battery health management ensures a longer service life (optimized battery maintenance and replacement when needed).
Optimized energy and capacity management
- Active ECO operating mode with up to 98% efficiency.
- Efficiency in online double conversion mode up to 95%.
- Energy Star 2.0 certified.
- Four individually programmable output receptacles can be used to extend runtime for the most critical loads and smart disconnection of less critical ones.
Seamless connectivity
- Four onboard, user-definable dry contact I/O for integration of support management systems.
- Supports SNMP, web, and environmental sensors with the optional RDU101 communications card.
- Serial connection for integration of Avocent® ACS product or direct serial management and control of the UPS.
Technical Specifications
Models | Liebert GXT5-500LVRT2UXL/LN | Liebert GXT5-750LVRT2UXL/LN | Liebert GXT5-1000LVRT2UXL/LN | Liebert GXT5-1500LVRT2UXL/LN | Liebert GXT5-2000LVRT2UXL/LN | Liebert GXT5-3000LVRT2UXL/LN |
---|---|---|---|---|---|---|
Ratings (VA/W) | 500VA/500W | 750VA/750W | 1000VA/1000W | 1500VA/1350W | 2000VA/1800W | 3000VA/2700W |
Dimensions, inches (mm) Unit W x D x H | 16.9 x 15.7 x 3.4 (430 x 400 x 85) | 16.9 x 15.7 x 3.4 (430 x 400 x 85) | 16.9 x 15.7 x 3.4 (430 x 400 x 85) | 16.9 x 18.5 x 3.4 (430 x 470 x 85) | 16.9 x 18.5 x 3.4 (430 x 470 x 85) | 16.9 x 21.3 x 3.4 (430 x 540 x 85) |
Weight, pounds (kg) Unit | 37 (16.8) | 37 (16.8) | 37 (16.8) | 46.2 (21) | 47.5 (21.6) | 66 (30) |
Input AC Parameters Range | Typical 120V Range: 60-150V | Typical 120V Range: 60-150V | Typical 120V Range: 60-150V | Typical 120V Range: 60-150V | Typical 120V Range: 60-150V | Typical 120V Range: 60-150V |
Frequency | 40-70Hz; Auto Sensing | 40-70Hz; Auto Sensing | 40-70Hz; Auto Sensing | 40-70Hz; Auto Sensing | 40-70Hz; Auto Sensing | 40-70Hz; Auto Sensing |
Input Power Cord | 10 ft. attached w/ NEMA 5-15P plug | 10 ft. attached w/ NEMA 5-15P plug | 10 ft. attached w/ NEMA 5-15P plug | 10 ft. attached w/ NEMA 5-15P A plug | NEMA L5-20P or 5-20P plug (5-20P adapter included) | 10 ft. attached w/ NEMA L5-30P plug |
Output Receptacles | 5-15R x 6 | 5-15R x 6 | 5-15R x 6 | 5-15R x 6 | L5-20R+5-20R x 6 | L5-30R+5-20R x 6 |
Waveform | Sine wave | Sine wave | Sine wave | Sine wave | Sine wave | Sine wave |
Utility (AC) Mode Overload | >200% for 250ms; 150-200% for 50 sec; 125-150% for 60 sec; 105-125% for 60 sec | >200% for 250ms; 150-200% for 50 sec; 125-150% for 60 sec; 105-125% for 60 sec | >200% for 250ms; 150-200% for 50 sec; 125-150% for 60 sec; 105-125% for 60 sec | >200% for 250ms; 150-200% for 2 sec; 125-150% for 50 sec; 105-125% for 60 sec | >200% for 250ms; 150-200% for 2 sec; 125-150% for 50 sec; 105-125% for 60 sec | >200% for 250ms; 150-200% for 2 sec; 125-150% for 10 sec; 105-125% for 15 sec |
Battery Type | Valve-regulated, non-spillable, lead acid | Valve-regulated, non-spillable, lead acid | Valve-regulated, non-spillable, lead acid | Valve-regulated, non-spillable, lead acid | Valve-regulated, non-spillable, lead acid | Valve-regulated, non-spillable, lead acid |
Backup Time (100% Load) | 17.9 | 10.4 | 6.7 | 6.7 | 4 | 4 |
Backup Time (50% Load) | 40.4 | 25.5 | 17.9 | 18.8 | 12.3 | 12.6 |
+1 External Battery Cabinet Backup Time (100% Load) | 76.3 | 45.4 | 32.6 | 32.4 | 22 | 22.2 |
+1 External Battery Cabinet Backup Time (50% Load) | 147.8 | 102.4 | 76.5 | 79.7 | 53.6 | 54.6 |
Environmental Requirements Operating Temperature, °F (°C) | +32 to +104 (0 to 40) | +32 to +104 (0 to 40) | +32 to +104 (0 to 40) | +32 to +104 (0 to 40) | +32 to +104 (0 to 40) | +32 to +104 (0 to 40) |
Storage Temperature, °F (°C) | -4 to +140 (-20 to 60) | -4 to +140 (-20 to 60) | -4 to +140 (-20 to 60) | -4 to +140 (-20 to 60) | -4 to +140 (-20 to 60) | -4 to +140 (-20 to 60) |
Relative Humidity | 0% to 95%, non-condensing | 0% to 95%, non-condensing | 0% to 95%, non-condensing | 0% to 95%, non-condensing | 0% to 95%, non-condensing | 0% to 95%, non-condensing |
Operating Elevation | 10,000 ft. (3,000m) | 10,000 ft. (3,000m) | 10,000 ft. (3,000m) | 10,000 ft. (3,000m) | 10,000 ft. (3,000m) | 10,000 ft. (3,000m) |
Storage Elevation | 50,000 ft. (15,000m) | 50,000 ft. (15,000m) | 50,000 ft. (15,000m) | 50,000 ft. (15,000m) | 50,000 ft. (15,000m) | 50,000 ft. (15,000m) |
Audible Noise | <46dBA max @ 3 ft. (1m) front and sides < 43dBA, at 3 ft. (1m) rear | <46dBA max @ 3 ft. (1m) front and sides < 43dBA, at 3 ft. (1m) rear | <46dBA max @ 3 ft. (1m) front and sides < 43dBA, at 3 ft. (1m) rear | < 46dBA at 3 ft. (1m) front and side < 45dBA at 3 ft. (1m) rear | <48dBA max @ 3 ft. (1m) front and side <48dBA max @ 3 ft. (1m) rear | <48dBA max @ 3 ft. (1m) front and side <48dBA max @ 3 ft. (1m) rear |
Agency Surge Immunity | ANSI C62.41 Category B | ANSI C62.41 Category B | ANSI C62.41 Category B | ANSI C62.41 Category B | ANSI C62.41 Category B | ANSI C62.41 Category B |
Transportation | ISTA Procedure 1A | ISTA Procedure 1A | ISTA Procedure 1A | ISTA Procedure 1A | ISTA Procedure 1A | ISTA Procedure 1A |
Safety | UL 1778 4th Edition and CSA 22.2 No 107.3 | UL 1778 4th Edition and CSA 22.2 No 107.3 | UL 1778 4th Edition and CSA 22.2 No 107.3 | UL 1778 4th Edition and CSA 22.2 No 107.3 | UL 1778 4th Edition and CSA 22.2 No 107.3 | UL 1778 4th Edition and CSA 22.2 No 107.3 |
Emissions | FCC Part 15 (Class A) - CISPR22 Class A (RFI) | FCC Part 15 (Class A) - CISPR22 Class A (RFI) | FCC Part 15 (Class A) - CISPR22 Class A (RFI) | FCC Part 15 (Class A) - CISPR22 Class A (RFI) | FCC Part 15 (Class A) - CISPR22 Class A (RFI) | FCC Part 15 (Class A) - CISPR22 Class A (RFI) |
Environmental | WEEE and ROHS2 REACH | WEEE and ROHS2 REACH | WEEE and ROHS2 REACH | WEEE and ROHS2 REACH | WEEE and ROHS2 REACH | WEEE and ROHS2 REACH |
Warranty | Std. 3 year; Opt. 2 year | Std. 3 year; Opt. 2 year | Std. 3 year; Opt. 2 year | Std. 3 year; Opt. 2 year | Std. 3 year; Opt. 2 year | Std. 3 year; Opt. 2 year |
Protection Plan | $500,000 | $500,000 | $500,000 | $500,000 | $500,000 | $500,000 |
Available Accessories
External battery cabinets and replacement battery kits
UPS | External battery cabinets | Replacement battery kits |
---|---|---|
GXT5-500LVRT2UXL | GXT5-EBC36VRT2U | GXT5-36VBATKIT |
GXT5-750LVRT2UXL | GXT5-EBC36VRT2U | GXT5-36VBATKIT |
GXT5-1000LVRT2UXL | GXT5-EBC36VRT2U | GXT5-36VBATKIT |
GXT5-1500LVRT2UXL | GXT5-EBC48VRT2U | GXT5-48VBATKIT |
GXT5-2000LVRT2UXL | GXT5-EBC48VRT2U | GXT5-48VBATKIT |
GXT5-3000LVRT2UXL | GXT5-EBC72VRT2U | GXT5-72VBATKIT |
Network communications and environmental sensors
- Network Communications: RDU101 (Intellislot web card for SNMP and web management. Supports environmental sensors.)
- Environmental Sensors: IS-RELAY, SN-Z01, SN-Z02, SN-Z03, SN-T, SN-TH, SN-2D, SN-3C, SN-L20 (Various sensors for temperature, humidity, and leak detection, with integrated or modular options.)
- UPS manageability options: Vertiv™ Power Insight Software Management (Complimentary web-based software to monitor Vertiv™ UPSs and rPDUs), Liebert® MicroPOD (Maintenance bypass and output distribution option for UPS products 3 kVA and below.)
Power Assurance Package: Comprehensive Service Support for Critical Systems
- Five-year protection plan with 100% parts coverage and 24x7 emergency service.
- On-site installation and startup of UPS and internal batteries (excludes hard-wired applications); configuration of new UPS and accessories; and safe removal and disposal of legacy UPS and batteries.
- On-site service support available 24x7 (within 150 miles of regional service center) and includes 100% labor and travel coverage.
- 100% parts coverage for UPS and includes internal batteries, POD (power output distribution), and web card.
- 24x7 access to customer resolution center and online access to Customer Services Network.
Key benefits:
- Hassle-free management of multi-site rollouts.
- Frees up time-strapped IT staff by managing and tracking UPS health, maintenance, and service.
- Reduces the worry of critical equipment downtime.
- Ensures rapid recovery in the event of failure (within 24-48 hours).
- Frees you from the responsibility of handling and documenting the disposal of legacy UPS and batteries.
Remote Diagnostic Services for Rapid Response
The Vertiv™ Liebert® GXT5 UPS system is designed for seamless integration with remote monitoring and management tools. This includes features like continuous monitoring for early detection of trends and operating anomalies, analysis and interpretation of alarm and status messages, automatic transmission of data for analysis, and concurrent diagnosis and dispatch of engineers to site. This ensures increased insight and ease of management, with notifications of operating conditions that may impact system health and periodic trend and analysis reports.
Mounting Kit Options
Application | Model Supported | Style | Model | Description |
---|---|---|---|---|
2 Post rack | Liebert® GXT5 UPS family (500VA to 10kVA) | Shelf | RS500 | Flush-mount shelf for 19" rack wide |
Shelf | RS600 | Center-mount shelf for 19" rack wide | ||
Shelf | RS700 | Flush-mount shelf for 23" rack wide | ||
Shelf | RS800 | Center-mount shelf for 23" rack wide | ||
Liebert® GXT5 up to 3kVA | Bracket | 2UTELECOMRKIT | Only center-mount bracket for 19" rack wide | |
Liebert® GXT5 up to 3kVA | Bracket | 2POSTRMKIT | Front flush/ center-mount bracket - 4-piece design | |
Wall Mount | Liebert® GXT5 up to 3kVA | Bracket | WMBKT2U | Wall mount bracket holds (1) GXT5 2U or (1) PSI5 2U product, steel painted black |
Bracket | WMBKT2USS | Wall mount bracket holds (1) GXT5 2U or (1) PSI5 2U product, stainless steel | ||
4 Post rack | Entire Liebert® GXT5 UPS family (500VA to 10kVA) | Bracket | RMKIT18-32 | Cabinet/racks with 18" - 32" deep support rails - Telescopic rail |
Note: RS600 and RS800 kits include adapter brackets for installation of up to (2) Liebert® GXT5 2U models.