User Manual for ANOLiS models including: Ambiane AP Ceiling Light, Ambiane AP, Ceiling Light, Light
2 2. Installation 1. Prepare a circular opening in the lower ceiling (1) as shown in the picture below. 2. Insert the Ambiane AP unit into the opening.
File Info : application/pdf, 10 Pages, 2.65MB
DocumentDocumentUser manual Ambiane AP (RGBW, RGBA, TD, PW, TW) The unit generates light by means of high power LEDs. The unit was designed for indoor use only. 1. Attention The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. The unit was designed for indoor use only. Avoid looking directly into the LED light beam at close range! Do not install the unit near highly inflammable liquids or materials. Do not allow anything to rest on the unit. Do not install the unit near an open flame. Do not install the unit in dirty,dusty or badly ventilated location. Sufficient air accessing to the housing of the unit has to be ensured, there must not be any heat or anti-noise insulation within a 0.6m x 0.6m area around the unit (non-IC rated fixture). Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity. The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment. Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B. Suitable for fastening on non-flammable surfaces only Unsuitable for covering by heat insulation material Always switch off power supply of the unit before connecting or disconnecting the unit 1 2. Installation 1. Prepare a circular opening in the lower ceiling (1) as shown in the picture below. 2. Insert the Ambiane AP unit into the opening. Fasten the Ambiane AP by means of two spring fasteners (2) to the opening. 3. Connect needed cables to the Ambiane AP. Connection blocks (4) are placed on the PCB RB 3727 (3). The PCB is under plastic cover (5) which is fastened by means of two screws (6). The primary power input serves for a standard power (e.g. Power Supply for Ambiane AP). The secondary power input serves for a backup power( in case that primary power failed). If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled. In case of primary power loss, the secondary power is enabled. If the Ambiane AP is supplied via the secondary power, the light intensity can be set by the trimmer (9). The Ambiane AP can be controlled by one of the following methods: DMX 512 DALI 0 - 10V (Ambiane PW, Ambiane TD only) The Ambiane AP is equipped with two DMX and DALI connection blocks for easy connection to DMX or DALI chain (In/Out method). 2 DMX connection PCB Function 0V - Shield D+ Signal (+) D- Signal (-) 0-10V connection PCB Function 0V 0V D+ +10V Power connection PCB Function + Power + - Power - Recommended diameters of conductors with respect to distance between Ambiane AP and power supply unit (Ambiane Power AP). Distance/cable length 50 m 100 m Diameters of conductors 0.5 mm2 1 mm2 3. DMX and DALI address setting and control The DIP switch (7), located next to the connection blocks, allows you to run a test light and switch the Ambiane AP to the update mode in case of software update. . DIP 10 - if switched to ON=test light (3200K for RGBW and TW version) DIP 11 - selection of fixture control: OFF=DMX 512 or DALI, ON=0-10V DIP 12 - change from OFF to ON position switches the Ambiane AP to the update mode (switching to the update mode is not necessary if the Robe Uploader is used for Ambiane AP update). DMX control The DMX start address, is the first channel used to receive instructions from the DMX controller. The address may be any channel from 1 to 509. DMX address can be set either by DIP switch or by RDM. DMX address set by RDM overwrites address set by DIP switch and vice versa. The green LED (8) on the PCB signals way of DMX address setting: LED lights-DMX address is set by means of the DIP switch. LED does not light- DMX address is set by means of RDM. DIP 11 has to be set in OFF position. Example of DMX addresses: DALI control Addressing of the Ambiane AP is made by means of an external DALI controller. The external DALI controller has to send activating command (8=ON) if you need to start the permanent control of the Ambiane AP (Ambiane 3 AP will not respond to DMX commands) and deactivating command (0=OFF) to stop control of the Ambiane AP. DIP 11 has to be set in OFF position. Note: If DIP 11=OFF (Ambiane AP is controlled by DMX or DALI), the first coming command switches the Ambiane AP to the corresponding operation mode (DMX operation by a DMX command, DALI operation by a DALI command). E.g. the Ambiane AP stays in a DALI operation and coming DMX command switches the Ambiane AP to DMX operation. Next command is a DALI command and switches the Ambiane AP to the DALI operation etc. If you need the permanent DALI operation, you have to send a DALI command 8 to the Ambiane AP. 0-10V control DIP 11 has to be set in ON position. 0-10V operation has priority to DALI commands. The option is applicable for Ambiane PW and Ambiane TD only. 4. RDM This Ambiane AP supports RDM operation. RDM (Remote Device Management) is a bi-directional communication protocol for use in DM X512 control systems, it is the new open standard for DMX512 device configuration and status monitoring. RDM allows you to set some options as DMX address, select DMX mode and readout software version of the Ambiane AP etc. Via RDM you can also set behaviour of the fixture in case of loss of DMX signal. For this purpose serve the following two options: DMX hold Value On (0) - the fixture keeps last received DMX values in case of DMX loss (default setting). Value Off (1) - it activates the option " DMX lost". To set the option "DMX hold" to Off, you have to send a value 1 via RDM. DMX lost The option is active only if the option "DMX hold" is set Off. Value On (0) - the fixture lights at max. light output in case of DMX loss (default setting). Value Off (1) - The light output of the fixture is closed in case of DMX loss. To set the option "DMX lost" to Off, you have to send a value 1 at RDM. RDM model ID for the Ambiane AP is 0x0114. Parameter ID Discovery command SET command DISC_UNIQUE_BRANCH * DISC_MUTE * DISC_UN_MUTE * DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_VERSION_LABEL DMX_START_ADDRESS * IDENTIFY_DEVICE * DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL * SENSOR_DEFINITION SENSOR_VALUE RESET_DEVICE * DMX_PERSONALITY * DMX_PERSONALITY_DESCRIPTION SENSOR_VALUE * SENSOR DEFINITION GET command * * * * * * * * * * * * * * 4 5. Anti-glare ring installation Insert the anti-glare ring (1) into the Ambiane AP until three locks (2) snap into slots (3). 6. Adapter ring installation 1.Remove both spring fasteners (2) by unscrewing the four screws M4x10 (1). 2. Slide the adapter ring (4) onto the housing of the Ambiane AP. Screw the new fasteners (3) on the housing. Use original screws M4x10 (1). 5 7. DMX protocols Ambiane RGBW , Ambiane RGBA Version 1.2 Mode 1 Mode 2 Channel Channe 1 1 - - 2 2 - - 3 3 - - 4 - - - - - - - - - - - Mode 3 Channe 1 2 3 4 5 6 7 8 9 10 11 12 Mode 4 Mode 5 Channe Channe Value Function - 1 Red 0-255 Red LEDs saturation control 0% -->100% - - Red Fine 0-255 Red LEDs saturation control from min. -->max. - 2 Green 0-255 Green LEDs saturation control 0% -->100% - - Green Fine 0-255 Green LEDs saturation control from min. -->max. - 3 Blue 0-255 Blue LEDs saturation control 0% -->100% - - Blue Fine 0-255 Blue LEDs saturation control from min. -->max. - 4 White/Amber 0-255 White (Amber) LEDs saturation control 0% -->100% - - White/Amber Fine 0-255 White(Amber) LEDs saturation control min. -->max. Green White Fine 0 Uncorrected white 1 - 1-127 Minus green --> uncorrected white 128 Uncorrected white (128=default) 129-255 Uncorrected white --> plus green Colour temperature correction (CTC) 0 No function (default) 1-10 Tungsten dimming 3200K 2 - 11-20 Tungsten dimming (3200K) 21-255 Colour temperature changing 2700K-6500K (21=2700K, 64-3200K, 128=4200K, 192-5600K, 255=6500K) 3 5 Dimmer 0-255 Light intensity coarse 0% -->100% - 6 Dimmer Fine 0-255 Light intensity from min. -->max. Type of control proportional proportional proportional proportional proportional proportional proportional proportional step proportional step proportional step step step proportional proportional proportional Ambiane PW, Ambiane TD Version 1.1 Mode 1 Channel 1 - Mode 2 Channel 1 2 Value Function 0-255 0-255 Dimmer Light intensity coarse 0% -->100% Dimmer Fine Light intensity from min. -->max. Type of control proportional proportional Ambiane TW Version 1.3 Mode 1 Channel 1 - - 2 - Mode 2 Channel - 1 2 3 - Mode 2 Mode 2 Channel Channel 1 - - 1 - 2 2 3 3 4 Value 0-255 0-255 0-255 0-255 0-255 Function White colour selection White from 2700K-->4000K Warm White Warm White LEDs saturation control 0% -->100% Cool White Cool White LEDs saturation control 0% -->100% Dimmer coarse Light intensity coarse 0% -->100% Dimmer Fine Light intensity from min. -->max. 6 Type of control proportional proportional proportional proportional proportional 8. Technical specifications Input voltage: Protection class : Max. power consumption: Beam angle: Colour temperature: Ambiane PW Ambiane TW Ambiane TD Control: Ambiane RGBW, Ambiane TW Ambiane PW, Ambiane TD DMX channels: Ambiane RGBW Ambiane PW, Ambiane TD Ambiane TW Typical Lumen maintenance: Led life expectancy: Operating ambient temp. range: Operating temperature: Total heat dissipation: Cooling : Housing: Weight: Installation method: IC rating: Power/DMX/DALI connection: Protection factor: Ambiane AP without Diffuser Glass 48V DC CE: (Class III ) ETL: Class 2 or LVLE 50W 67°, 80° with anti-glare ring 2700K, 4000K 2700K - 4000K 3200K DMX, DALI, RDM compatible DMX, DALI, 0-10V, RDM compatible 4 (Mode 1), 3 (Mode 2), 12 (Mode 3), 3 (Mode 4), 6 (Mode 5) 1 (Mode 1), 2 (Mode 2) 2 (Mode 1), 3 (Mode 2) 70%@ 50,000 hours minimum 50,000 hours -20°C/+45°C (-4F/+113F) 75°C @ Ambient +35°C (167°F @ Ambient +95°F) 136 BTU/h (calculated) convection alluminium 1.9 kg| (4.19 lbs) via two spring fasteners non-IC rated terminal blocks IP 20 (without diffuser glass), IP20/IP54 (with Diffuser Glass) Ambiane AP with Diffuser Glass 9.Included items 1 x Ambiane AP 1x Anti-Glare Ring (P/N 10980386) 1 x Set of cable connectors 1 x User manual 10. Optional Accessories Ambiane Power AP (P/N 10063994) Anti-Glare Ring (P/N 10980386) Adapter Ring (235-255mm ) (P/N 10980388) 7 11. Dimensions mm [inch] 12. Maintenance Keep the Ambiane AP clean, especially light source and the ribbed housing. 8 13. Software update Software update of the fixture can be done by means of the ROBE Uploader. It is a software for automatized software update of Robe and Anolis fixtures. It takes advantage of RDM support. The fixtures have to be connected in a daisy-chain (max. 32 fixtures) and via the Robe Universal Interface/ Robe Universal Interface WTX and a USB cable connected to the control PC with the Robe Uploader running. The control PC should be connected to the Internet. Note: If you do the software update by means of the Robe Uploader, switching fixtures to the update mode (and from the update mode) is made automatically, without need to switch the DIP 12 to ON position (update mode). The Robe Uploader software cannot be used if fixtures are connected by means of DALI connection. 9 The Robe Uploader software and user manual is available at : https://www.robe.cz/robe-uploader/ Version 1.8 November 22, 2021 Specifications are subject to change without notice. Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici 10