Owner's Manual for NOTIFIER models including: PF24V ExitPoint Directional Sounder, PF24V, ExitPoint Directional Sounder, Directional Sounder, Sounder
Notifier PF24V(A) ExitPointTM Directional Sounder with Voice Messaging - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 2 Pages, 708.03KB
DocumentDocumentPF24V(A) ExitPointTM Directional Sounder with Voice Messaging DN-60245:B General The ExitPointTM Directional Sounder has an integral audio amplifier that produces a pulsating sound consisting of broadband low, mid, and high range sounds. The broadband noise makes it possible to determine the location of the sound. There are four pulse patterns that can be used to create an egress pathway out of a building and to mark perimeter exits. In addition to the broadband noise, the sounder is capable of playing an alert message in the form of a recorded voice message or other audible signals. These messages will instruct the occupants of what action to take as they approach the directional sounder, and will allow them to react quickly and confidently when the sounder is activated. Fifteen different language combinations are available to instruct occupants that they are nearing an exit, a stairway up, a stairway down, or an area of refuge. The directional sounder also incorporates an optional disable feature for use in conjunction with a control module or heat sensor. The directional sounder features a number of field selectable power settings including high, medium-high, medium-low, and low. Installation ease and pleasing aesthetics are achieved by a low profile compact design, and by the ability to flush mount in a 4" x 4" x 2¼" back-box. ExitPoint directional sounders, fitted in addition to normal building evacuation sounders, draw people to evacuation routes in both good and poor visibility. The directional sounder can be used in a wide range of building applications. Trials consistently have shown an improvement of up to 75 percent in evacuation times in smoke and up to 35 percent without smoke. The 2007 Edition of NFPA 72 now provides installation and maintenance guidelines on directional sounders. Features · Listed to UL 464 (indoor applications only) · Five field-selectable power settings · Four field-selectable routing evacuation patterns · Constructed to be effective in unfamiliar surroundings or poor visibility · Designed to work in open areas, corridors, or stairs · Fifteen different language selections available · Reduces evacuation times by as much as 75 percent · Optional disable feature for use in conjunction with a control module or heat sensor · Low profile, compact design Specifications ELECTRICAL SPECIFICATIONS Voltage Input: Regulated 24 Volts Operating Voltage Range: 16 to 33 Volts Operating Temperature: 32°F to 120°F (0°C to 49°C) Power Setting: High, medium-high, medium, medium-low, low MECHANICAL SPECIFICATIONS Input Terminals: 12-24 AWG Speaker Size: 4" (101 mm) Grille Size: 4 7/8" (127 mm) Audio/Visual Devices 7044pho1.jpg Additional Tone Selection Switch Position Switch Position 5 Setting 6 Setting Sound Output On On Area of Refuge On Off Upstairs Off On Downstairs Off Off Exit Here Enable/Disable Selection Switch Position 4 Setting Terminals 3 & 4 Sound Output On Open Disabled On Closed Enabled Off Open Enabled Off Closed Disabled Power Setting Guide DIP Switch DIP Switch DIP Switch Position 1 Position 2 Position 3 Setting Setting Setting Power Setting Off Off Off High On Off Off Med-High Off On Off Med Off Off On Med-Low On On On Low firealarmresources.com DN-60245:B · 06/17/2010 -- Page 1 of 2 Current Draw Measurements and Sound Output Guide Speed DIP Switch Selection Power Setting Max DC Operating Current (mA RMS) Audibility Audibility (dBA) (dBA) Note 1 Note 2 Fast (Exit) 10 High 185 84 75 Fast (Exit) 10 Med-High 131 81 72 Fast (Exit) 10 Med 78 78 69 Fast (Exit) 10 Med-Low 76 75 66 Fast (Exit) 10 Low 64 72 63 Med-Fast 9 High 170 83 74 Med-Fast 9 Med-High 124 80 71 Med-Fast 9 Med 75 77 68 Med-Fast 9 Med-Low 73 74 65 Med-Fast 9 Low 62 71 62 Med-Slow 8 High 135 82 73 Med-Slow 8 Med-High 104 79 70 Med-Slow 8 Med 67 76 67 Med-Slow 8 Med-Low 65 73 64 Med-Slow 8 Low 57 70 61 Slow 7 High 120 82 72 Slow 7 Med-High 92 79 69 Slow 7 Med 62 76 66 Slow 7 Med-Low 61 73 63 Slow 7 Low 54 70 60 Note 1: Sound output measured in anechoic room at 10 feet. Note 2: Sound output measured in a reverberant room at 10 feet. Language/Audible Tone Selection Guide Rotary Switch Tone/Language Selection 0 Audible tone/sweep 1 English 2 Spanish 3 French 4 English/Spanish 5 English/French 6 Korean 7 Cantonese 8 Mandarin 9 English/Cantonese 10 English/Mandarin 11 Cantonese/Mandarin 12 English/Korean 13 English/Portuguese 14 English/Russian 15 English/Polish Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. · UL Listed: S4011 · ULC Listed: S8971 · FM Approved · CSFM: 7135-1653:175 · MEA Approved: 492-04-E Vol. 2 Ordering Information PF24V: ExitPoint Directional Sounder with Voice Messaging PF24VA: Same as PF24V, but with ULC (Canada) BBS-SP201W: Surface mount backbox skirt for PF24V NOTIFIER® and System Sensor® are registered trademarks and ExitPointTMis a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 -- DN-60245:B · 06/17/2010 firealarmresources.com Made in the U.S. A.