MITSUBISHI ELECTRIC EUROPE B.V.
Industrial Automation
Mitsubishi-Electric-Platz 1 40882 Ratingen Deutschland
Telefon +49 (0) 2102 486-0 Fax +49 (0) 2102 486-1120
https://emea.mitsubishielectric.com/fa
MATERIAL FACT SHEET
168448 AE3200-SW 4P F 3200A
General Data
Product Hierarchy | ACB |
Ext. Material Group | AE-SW Body |
ABC Indicator | 10 STANDARD ITEM |
e-shop | https://mitsubishi-electric-eshop.mee.com/mee/FA_IA/EUR/en/p/000000000000588205 |
Series | AE-SW SERIES |
Type | FIXED TYPE |
Frame Size | 3200 |
Rated Voltage (V) | 690 |
Number of Poles | 4 |
Rated Current (A) | 3200 |
Current Type | AC |
Current Range Ir (A) | 1600-3200 |
Breaking Capacity at 500V (kA) | 85 |
Compliant with Standard(s) | EN60947-2 |
Compliant with Standard(s) (2) | IEC60947-2 |
Compliant with Standard(s) (3) | JIS C 8201-2-1 |
Cycles with Rated Current | 1000 |
Cycles without Rated Current | 20000 |
No of Auxiliary Contacts NO | 5 |
No of Auxiliary Contacts NC | 5 |
Internal Power Supply (V) | 100-240 AC 100-125 DC |
Power consumption (W) | 72 |
Automatic Tripping Device | ELECTRONIC |
Product Dimensions & Weight
Width (mm) | 605 |
Height (mm) | 410 |
Depth (mm) | 290 |
Weight (kg) | 75 |
Logistic Dimensions & Gross Weight
Length (cm) | 85.0 |
Width (cm) | 61.0 |
Height (cm) | 62.0 |
Gross Weight (kg) | 90.000 |
Volume (cdm) | 321,470 |
Stock Data
Planned Delivery Time (Days) | 108 |
Life Cycle
Sales Start | 19.03.2006 |
Predecessor | 129247 / AE3200-SS 4P 3200A |
Additional Product Information
Battery included | NO |
Export Data
Commodity Code | 85365080 |
Legal Control (Dual Use List) | Not Listed |
Country of Origin
Country of Origin | Japan (JP) |
Preference Status (Supplier Declaration) | Non EU |
Environmental
REACH Limit Exceeded | YES |
REACH Substance CAS Number | 10141-05-6 |
REACH Substance CAS Number (2) | 108-78-1 |
REACH Substance CAS Number (3) | 140-66-9 |
REACH Substance CAS Number (4) | 540-97-6 |
REACH Substance CAS Number (5) | 541-02-6 |
REACH Substance CAS Number (6) | 556-67-2 |
REACH Substance CAS Number (7) | 71868-10-5 |
REACH Substance CAS Number (8) | 7439-92-1 |
Dangerous Goods Class | NO |
Dangerous Goods Identifier | NO |
RoHS Compliance | COMPLIANT |
WEEE | B2B |
Conformity
CE | COMPLIANT |
UL/cUL | NON-COMPLIANT |
EAC | NON-COMPLIANT |
Shipping Approvals | ABS, BV, CCS, DNV-GL, LR, NK |
UKCA | COMPLIANT |
Documentation & Media Data
Product Packaging
Cardboard (g) | 5000 |
Other paper (g) | 0 |
Aluminum (g) | 0 |
Steel (g) | 348 |
Styrofoam (g) | 0 |
Other plastic (g) | 0 |
Wood (g) | 9800 |
Glass (g) | 0 |
Others (g) | 0 |
Compatible products
Material | Description / Price List Text / Classification |
---|---|
168510 | SST-LOCK-W Shutter lock (for padlock) Class 100100703: FA-ACB: Mechanical Option |
168512 | CL-4-W Cell switch 2C1T1D Class 100100704: FA-ACB: Electrical Option |
168513 | DF-W Door frame Class 100100703: FA-ACB: Mechanical Option |
168514 | MD-AD125-W Motor charging device; AC/DC 100 - 125V Class 100100704: FA-ACB: Electrical Option |
168515 | MD-AD250-W Motor charging device; AC/DC 200 - 250V Class 100100704: FA-ACB: Electrical Option |
168518 | MD-D024-W Motor charging device; DC 24V Class 100100704: FA-ACB: Electrical Option |
168519 | MD-D048-W Motor charging device; DC 48V Class 100100704: FA-ACB: Electrical Option |
168520 | CC-AD250-W Closing coil; AC/DC 100 - 250V Class 100100704: FA-ACB: Electrical Option |
168521 | CC-D048-W Closing coil; DC 24 - 48V Class 100100704: FA-ACB: Electrical Option |
168522 | SHT-AD250-W Shunt release; AC/DC 100 - 250V Class 100100704: FA-ACB: Electrical Option |
168523 | SHT-A500-W Shunt release; AC/DC 380 - 500V Class 100100704: FA-ACB: Electrical Option |
168524 | SHT-D048-W Shunt release; DC 24 - 48V Class 100100704: FA-ACB: Electrical Option |
168526 | UCONLABEL-W Label for Under voltage trip controller Class 100100704: FA-ACB: Electrical Option |
168535 | TCA-AL-W Trip coil (Auto reset type) with OCR alarm Class 100100704: FA-ACB: Electrical Option |
168536 | TCM-AL-W Trip coil (Manual reset type) with OCR alarm Class 100100704: FA-ACB: Electrical Option |
168537 | BCL-W Push button cover Class 100100703: FA-ACB: Mechanical Option |
168538 | CNT-W Counter Class 100100704: FA-ACB: Electrical Option |
168539 | CYL-WK-W Cylinder lock with key No. (#R0220) - Standard Class 100100703: FA-ACB: Mechanical Option |
168540 | CYL-WK1-W Cylinder lock with key No. (#R501) Class 100100703: FA-ACB: Mechanical Option |
168541 | CYL-WK2-W Cylinder lock with key No. (#R502) Class 100100703: FA-ACB: Mechanical Option |
168542 | CYL-WK3-W Cylinder lock with key No. (#R503) Class 100100703: FA-ACB: Mechanical Option |
168543 | CYL-WK4-W Cylinder lock with key No. (#R504) Class 100100703: FA-ACB: Mechanical Option |
168544 | CYL-NK-W Castell lock without key Class 100100703: FA-ACB: Mechanical Option |
168545 | DI-F-W Door interlock for fixed type Class 100100703: FA-ACB: Mechanical Option |
168547 | MIP-W Mis insertion preventer (up to AE4000-SWA frame) Class 100100703: FA-ACB: Mechanical Option |
168548 | SBC-1-W Shorting b-contact for 1 NC Auxiliary switch (mountable at cradle) Class 100100704: FA-ACB: Electrical Option |
168552 | WS1-W Main setting module for general protection use Class 100100704: FA-ACB: Electrical Option |
168554 | WM1-W Main setting module for generator protection use Class 100100704: FA-ACB: Electrical Option |
168558 | G1-W Optional setting module for ground fault protection Class 100100704: FA-ACB: Electrical Option |
168559 | E1-W Optional setting module for earth leakage protection Class 100100704: FA-ACB: Electrical Option |
168560 | AP-W Optional setting module for 2nd Additional Pre-alarm Class 100100704: FA-ACB: Electrical Option |
168561 | N5-W Optional setting module for Neutral pole 50% protection Class 100100704: FA-ACB: Electrical Option |
168562 | PW4-W Power supply DC 24 - 60V with output contact Class 100100704: FA-ACB: Electrical Option |
168563 | PW5-W Power supply DC 100 - 240V with output contact Class 100100704: FA-ACB: Electrical Option |
168564 | EX1-W Extension module for display and interface function Class 100100704: FA-ACB: Electrical Option |
168565 | DP1-W Display module Class 100100704: FA-ACB: Electrical Option |
168566 | DP2-W Display module onto panel board Class 100100704: FA-ACB: Electrical Option |
168567 | VT-W VT unit enable to measures Class 100100704: FA-ACB: Electrical Option |
168570 | MCS-W MCR Switch for MCR function Class 100100704: FA-ACB: Electrical Option |
168573 | BIF-MD-W Interface Unit - Modbus Class 100100704: FA-ACB: Electrical Option |
168574 | BIF-CON-W I / O Unit for breaker remote control Class 100100704: FA-ACB: Electrical Option |
168575 | BIF-CL-W Drawout position switch for network Class 100100704: FA-ACB: Electrical Option |
168960 | DUC-W Dust cover IP54 Class 100100703: FA-ACB: Mechanical Option |
168961 | HAX-10-W Auxiliary switch; 5a5b for high DC capacity Class 100100704: FA-ACB: Electrical Option |
168962 | AX-10-W Auxiliary; switch 5a5b Class 100100704: FA-ACB: Electrical Option |
168966 | MI-404F-W Mech.I interlock for 4-pole fixed breakers AE2000-SW - AE3200-SW, AE4000-SWA Class 100100703: FA-ACB: Mechanical Option |
168971 | MI-IW-W Wire set for among 3 breakers Class 100100703: FA-ACB: Mechanical Option |
168972 | TTC-F-W Terminalcover - transparent for control terminal Class 100100703: FA-ACB: Mechanical Option |
168976 | SST-404-W Safety shutter for AE2000-3200-SW, AE4000-SWA 4-poles Class 100100703: FA-ACB: Mechanical Option |
168977 | TJ-W Test jumper Class 100100704: FA-ACB: Electrical Option |
168980 | VTA-32-W Vertical terminal adapter for AE3200-SW (1pcs.) Class 100100704: FA-ACB: Electrical Option |
168985 | PW3-W Power supply AC 100-240V / DC 100-125V with output contact Class 100100704: FA-ACB: Electrical Option |
168992 | NCT-32-W Current transformer for neutral pole; 3200A Class 100100704: FA-ACB: Electrical Option |
168997 | ZT-15B-W Zero phase Current transformer for transformer ground wire 15mm diameter Class 100100704: FA-ACB: Electrical Option |
168998 | ZT-30B-W Zero phase Current transformer for transformer ground wire 30mm diameter Class 100100704: FA-ACB: Electrical Option |
168999 | ZT-40B-W Zero phase Current transformer for transformer ground wire 40mm diameter Class 100100704: FA-ACB: Electrical Option |
169000 | ZT-60B-W Zero phase Current transformer for transformer ground wire 60mm diameter Class 100100704: FA-ACB: Electrical Option |
169001 | ZT-80B-W Zero phase Current transformer for transformer ground wire 80mm diameter Class 100100704: FA-ACB: Electrical Option |
169002 | ZT-100B-W Zero phase Current transformer for transformer ground wire 100mm diameter Class 100100704: FA-ACB: Electrical Option |
169336 | FTA-324F-W Front terminal adapter set for AE3200-SW 4-pole fixed type (8 pcs.) Class 100100703: FA-ACB: Mechanical Option |
169342 | FTA-324D-W Front terminal adapter set for AE3200-SW 4-pole drawout type (8 pcs.) Class 100100703: FA-ACB: Mechanical Option |
170081 | CRD324-W Cradle with horizontal connections for AE3200-SW 4 poles Class 100100703: FA-ACB: Mechanical Option |
202337 | SBC-2-W Shorting b-contact for 2 NC Auxiliary switch (mountable at cradle) Class 100100704: FA-ACB: Electrical Option |
202338 | SBC-3-W Shorting b-contact for 3 NC Auxiliary switch (mountable at cradle) Class 100100704: FA-ACB: Electrical Option |
203340 | SBC-5-W Shorting b-contact for 5 NC Auxiliary switch (mountable at cradle) Class 100100704: FA-ACB: Electrical Option |
203340 | UCON-A240A-W(INST) Controller; AC 200 - 240V Inst. trip (Time delay adj.), a-contact Class 100100704: FA-ACB: Electrical Option |
203341 | UCON-D024B-W(INST) Controller; DC 24V Inst. trip (Time delay adj.), b-contact Class 100100704: FA-ACB: Electrical Option |
203342 | UCON-D048B-W(INST) Controller; DC 48V Inst. trip (Time delay adj.), b-contact Class 100100704: FA-ACB: Electrical Option |
203343 | UCON-D110B-W(INST) Controller; DC 100 - 110V Inst. trip (Time delay adj.), b-contact Class 100100704: FA-ACB: Electrical Option |
203344 | UCON-D125B-W(INST) Controller; DC 120 - 125V Inst. trip (Time delay adj.), b-contact Class 100100704: FA-ACB: Electrical Option |
203345 | UCON-D250B-W(INST) Controller; DC 220 - 250V Inst. trip (Time delay adj.), b-contact Class 100100704: FA-ACB: Electrical Option |
203346 | UCON-A120B-W(INST) Controller; AC 100 - 120V Inst. trip (Time delay adj.), b-contact Class 100100704: FA-ACB: Electrical Option |
203347 | UCON-A240B-W(INST) Undervoltage Trip Device; AC200-240V; Inst. trip (Time delay adj.); b-contact Class 100100704: FA-ACB: Electrical Option |
203348 | UCON-A460B-W(INST) Controller; AC 380 - 460V Inst. trip (Time delay adj.), b-contact Class 100100704: FA-ACB: Electrical Option |
233426 | Y-2005 Portable tester unit to check of tripmechanism and relay adjustment Class 100100704: FA-ACB: Electrical Option |
588205 | UCON-A460A-W(INST) Controller; AC 380 - 460V Inst. trip (Time delay adj.), a-contact Class 100100704: FA-ACB: Electrical Option |