Instructions for INTERMATIC models including: PE35300, PE35300 Wireless Control System, Wireless Control System, Control System, System
Intermatic Digital control centers, parts, manuals
Index of /pdf
File Info : application/pdf, 1 Pages, 177.46KB
DocumentDocumenthttp://waterheatertimer.org/Digital-control-centers-and-manuals.html#PE35300 MODEL: PE35300 CLASS CTL DISTRIBUTION /CONTROL PANEL RAINPROOF TYPE 3R ENCLOSURE FOR INDOOR/OUTDOOR USE. SUITABLE FOR SWIMMING POOL/SPA APPLICATIONS AND FOR DIRECT CONNECTION TO A WET-NICHE OR NO-NICHE LUMINAIRE. ALL DEVICES IN THIS CONTROL MUST BE SUPPLIED BY BRANCH CIRCUIT PROTECTORS LOCATED WITHIN THIS ENCLOSURE. 80 A 120/240 V or 120/208 V single phase (three wire) AC, 60 Hz The short circuit rating of this panel is 10000 RMS symmetrical amperes. LR3730 UL508 UL1563 NEC680 WARNING Risk of Fire or Electric Shock · Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing. · Installation and/or wiring must be in accordance with National Electrical Code (Article 680)/Canadian Electrical Code (Section 68) and local electrical code requirements and is subject to approval by the local inspection authority. · Use #14 - #6 AWG COPPER conductors ONLY, rated 75° C min., for branch circuit and #14 - #2 AWG for main lugs and neutral main. · For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for fittings for conduit and outlet boxes) are to be used. · Install only LISTED receptacle(s) and/or wiring device(s) inside the enclosure. · The control panel is to be a minimum of 3m (in Canada) or 5ft (in USA) from the inside wall of the pool, spa, or pond, unless separated from the body of water by a fence, wall or other permanent barrier that will make the unit inaccessible to persons in the water. · If this enclosure is used for direct conduit connection to a wet-niche or no-niche luminaire, one of the connection kits listed below in NOTE 6 must be used. · When panel is outdoors, a LISTED rainproof cover must be installed over the wiring device in the side knockout. · This control should not be connected to any equipment which would cause bodily injury or property damage should it be activated unexpectedly. · Follow circuit breaker manufacturer's installation instructions. · Do not connect two or more power supplies in parallel. · Replace front panel covering terminals before powering ON. · KEEP DOOR CLOSED AT ALL TIMES when not servicing. AVERTISSEMENT Risque d'incendie ou d'électrocution · L'installation et le câblage doivent être réalisés conformément au Code national de l'électricité (article 680)/Code canadien de l'électricité (section 68) et aux exigences des normes électriques régionales et sont soumis à l'approbation de l'organisme de contrôle local. · Utiliser UNIQUEMENT des conducteurs en CUIVRE de 14 à 6 AWG, évalués à 75 °C min, pour le circuit de dérivation et de 14 à 2 AWG pour les cosses principales et le fil neutre. · Pour les emplacements extérieurs ou les endroits humides (étanches à la pluie), utiliser des entrées de conduits conformes aux exigences de la norme UL514B pour les pièces de fixation pour conduits et boîtes de sortie. · Le panneau de commande doit se trouver à au moins 3 m (au Canada) ou 5 pi (aux États-Unis) de la paroi interne de la piscine, du spa ou de l'étang, à moins qu'il ne soit séparé du plan d'eau par une clôture, un mur ou toute autre barrière permanente rendant l'unité inaccessible aux personnes se trouvant dans l'eau. · Si ce boîtier est utilisé pour le raccordement direct d'un conduit à un luminaire avec niche immergée ou sans niche, l'une des trousses de raccordement indiquées ci-dessous à la REMARQUE 6 doit être utilisée. SUITABLE LISTED BREAKERS WIRING INFORMATION - COPPER CONDUCTORS ONLY MANUFACTURER CUTLER-HAMMER MURRAY SIEMENS SQUARE D GE (up to 40 A) SINGLE BR MP-T QP HOM THQL DOUBLE BR MP-T QP HOM THQL CIRCUIT BREAKER TWIN QUAD GFCB BRD BRD GFCB MH-T MH-T MP-GT QT QT QPF HOMT HOMT HOM -- -- THQL-GF, GF1 FILLER PLATE BRFP WIRE SIZE LX100FP 75°C MIN QF3 INSULATION HOMFP AWG THFILLER 14 12 TERMINAL TORQUEa MAX MOTOR SUPPLY LINE AND LOAD CIRCUIT NEUTRAL NEUTRAL (CONTINUOUS BREAKER MAIN AND DUTY) RATING LUGS GROUND 120 V 240 V AMP LB-IN LB-IN HP HP 15 35 20 1/2 1 20 35 20 1 2 GENERAL PURPOSE BRANCH CIRCUIT MAX BREAKER CURRENT RATING CAPACITY AMP AMP 15 12 20 16 NOTES: 10 1. Any Intermatic T100M or ET100CM Series Time Switch, PF1000M Series Freeze Protection or 8 RC2000M Series Air Switch mechanisms, P1353ME mechanism, P4243ME mechanism, or P4043ME mechanism may be installed in the bracket(s) provided or in the event an existing mechanism(s) is replaced. The P5043ME can also be used in this panel in conjunction with a MultiWave Control 6 4 30 35 20 1 1/2 3 30 24 50b 40 25 2 5 40 32 65 45 35 --- --- 60 44 80 45 35 --- --- --- --- System. If a filler plate is needed, contact factory. 2. An additional ground bar may be installed in this control panel (order 130T1318A). aTORQUE CIRCUIT BREAKER LUGS TO VALUES SPECIFIED ON CIRCUIT BREAKERS b45 A FOR CANADA 3. If this control panel requires bonding, attach a LISTED bonding terminal of a suitable size using the mounting hole(s) provided on the bottom of the enclosure. SEE NOTE 7 4. When a circuit breaker is back-fed, 22T904A breaker hold-down kit must be used. 5. A wiring device may be installed in this control panel (order 21T156A (4) standoffs for mounting). 6. The following kits are available to connect underwater luminaires to this enclosure: 1/2" non-metallic - order 156PA13713A 3/4" non-metallic - order 156PA13714A PE35300 1" non-metallic - order 156PA13715A 1/2" metallic - order 156PA14336A 6. Voici les trousses disponibles pour raccorder des luminaires sous-marins à ce boîtier : Non métallique de 12,7 mm (1/2 po) - Réf. 156PA13713A Non métallique de 19 mm (3/4 po) - Réf. 156PA13714A Non métallique de 2,54 mm (1 po) - Réf. 156PA13715A Métallique de 12,7 mm (1/2 po) - Réf. 156PA14336A 7. This KO is for installing an optional PE653RC MultiWave wireless receiver and remote control system, which can be used with the P5043ME in NOTE 1 above. CONTACT RATINGS - EACH CIRCUIT, (P1353ME) 3-CIRCUIT DIGITAL CONTROL RATINGS: 17 A Resistive, 120/240 VAC, 60 Hz CLOCK SOURCE VOLTAGE: 120/240 VAC, 60 Hz 17 FLA, 80 LRA, 120/240 VAC, 60 Hz POWER CONSUMPTION: 6.0 W Max 5 A Tungsten, 120/240 VAC, 60 Hz CONTACT CONFIGURATION: SPST - each circuit Aux. Switch, 2 A, 24 VDC EVENTS PER CIRCUIT: 3 ON/OFF Events Per Circuit MEMORY RETENTION: 40-year retention for all programmed settings. 8-hour time retention. P1353ME OPERATING INSTRUCTIONS 1. Press PROG Key to cycle through menu options. 2. Press UP and DOWN arrow keys to change program settings. 3. Press ENTER key to save changes and exit programming mode. 4. Press ON/OFF keys to manually turn devices ON or OFF. VALVE ACTUATOR SUPPLY: 24 V - 40 VA MAX. 154--02353 INTERMATIC INCORPORATED SPRING GROVE, ILLINOIS 60081-9698