Instruction Manual for BEKA models including: BA334G Externally Powered Rate Totaliser, BA334G, Externally Powered Rate Totaliser, Powered Rate Totaliser, Totaliser
Abbreviated Instruction manuals
File Info : application/pdf, 2 Pages, 802.44KB
DocumentDocument1. DESCRIPTION The BA334G is a field mounting intrinsically safe, one input Rate Totaliser which will function with a wide variety of sensors. The instrument can display rate of flow and total flow in the same or different engineering units. This abbreviated instruction sheet is intended to assist with installation, a comprehensive instruction manual describing safety certification, system design and configuration may be downloaded from the BEKA website or may be requested from the BEKA sales office. The BA334G Rate Totaliser has IECEx, ATEX, UKEX, ETL and cETL intrinsic safety certification for use in flammable gas and dust atmospheres. The certification information label, which is located on the top of the instrument assembly, shows the certification numbers and codes. Other certifications may be shown. Copies of certificates may be downloaded from the BEKA website. Typical certification information label 2. INSTALLATION The BA334G Rate Totaliser has a robust IP66 glass reinforced polyester (GRP) carbon loaded enclosure incorporating an armoured glass window & stainless steel fittings. It is suitable for exterior surface mounting in most industrial environments, or pipe mounting using an accessory kit. If the enclosure is not bolted to an earthed post or structure, the earth terminal on the cable entry bonding plate, which may be assembled on the inside or outside of the enclosure, should be connected to local earthed metalwork or to the plant's potential equalising conductor. Terminals A1, A2, A3 and A4 are only fitted when the Rate Totaliser includes optional alarms. Similarly terminals C1, C2, C3 and C4 are only fitted when the instrument has an optional 4/20mA output. See full manual for details. A A DISPLAY A A Step A Unscrew the four captive 'A' screws and separate the indicator assembly and the back-box. B B Insulated stud for joining cable screens Earth B stud B Step B Secure the enclosure back-box to a flat surface with M6 screws through the four 'B' holes. Alternatively use a pipe mounting kit. Step C Remove the temporary hole plug and install an appropriate IP rated cable gland or conduit fitting. Feed the field wiring through the cable entry. A A Step D Terminate field wiring on the instrument assembly. Replace the assembly on the enclosure back-box and tighten the four A A 'A' screws. Fig 1 BA334G installation procedure Abbreviated Instruction for BA334G intrinsically safe field mounting Rate Totaliser P E Issue 2 24th November 2022 BEKA associates Ltd. Old Charlton Rd, Hitchin, Hertfordshire, SG5 2DA, UK Tel: +44(0)1462 438301 e-mail: sales@beka.co.uk web: www.beka.co.uk 122 Optional 84 stainless 25 steel legend plate. 120 DISPLAY 90 19 Four M6 clearance holes for 106 surface mounting. To remove the scale card carefully pull the tab perpendicularly away from the instrument assembly. See Fig 2 for the location of the scale card tab. Two M20 x 1.5 tapped cable 90 entries. Supplied with an IP66 stopping plug and one temporary hole plug. pulse input + Add link to energise pulse input Optional A1 + 6 A2 5 4 A3 + 3 A4 Alarm 1 1 2 Alarm 2 RS1 RS2 4/20mA output P1 C4 P2 C3 + C2 C1 Optional + Power supply External reset + Pulse output Scale Card tab E P Fig 4 Inserting scale card into instrument assembly To replace the scale card carefully insert it into the slot shown in Fig 2. Force should be applied evenly to both sides of the scale card to prevent it twisting. The card should be inserted until about 2mm of the transparent tab remains protruding. Fig 2 Dimensions and terminal connections EMC For specified immunity all wiring should be in screened twisted pairs with screens earthed at one point within the safe area. Hazardous area Safe area DISPLAY RS2 RS1 Proximity detector 65 43 + 21 ++ Switch contact/ open collector OR Voltage pulse N S Magnetic pick-off 65 43 + No link External reset Single channel positive polarity 28V: 93mA Zener Barrier + Power supply Single channel positive polarity 28V: 93mA Zener Barrier Remote reset in safe area Fig 3 Typical measurement loop Scale card The instrument's units of measurement and tag information are shown above the display on a slide-in scale card. New instruments are fitted with a scale card showing the information specified when the instrument was ordered, if this was not provided a blank scale card will be fitted which can easily be marked on-site. Custom printed scale cards are available from BEKA associates. 3. OPERATION The BA334G is controlled and configured via four front panel push buttons. In the display mode i.e. when the instrument is displaying flow the push button functions are: ) + & Grand total - shows Lo followed by least significant 8 digits of the 16 digit grand total. ) + * Grand total - shows Hi followed by the most significant 8 digits of the 16 digit grand total. If Local Grand Total Reset CLr Gtot in the instrument configuration menu has been activated, operating the ) and * buttons for ten seconds will result in Clr. no being displayed with the no flashing. Operating the & or * button will change the display to CLr . YE5, the ) button will then reset the grand total to zero which will be confirmed by a brief display of Gt Clrd. & + * If Local Total Reset CLr tot in the instrument configuration menu has been activated, operating the & and * buttons for three seconds will reset the total display to zero and clear any pulses stored in the optional pulse output. The Grand Total is not reset. ( + & Shows in succession, firmware version number, instrument function totali5e and any output accessories that are fitted: -A Dual alarm outputs -P Pulse output (always fitted) -c 4/20mA output ( + * Provides direct access to the alarm setpoints when the Rate Totaliser is fitted with optional alarms and the AC5P setpoints function has been enabled. ( + ) Access to configuration menu Display mode DISPLAY ( ) ) code ( 0000 Security Code Enter code by pressing & or * & ( to move to next digit. Code 0000 allows direct access to the menu 4. CONFIGURATION Rate Totalisers are supplied configured as requested at time of ordering, if not specified default configuration will be supplied but can easily be changed on-site. Fig 5 shows the location of each function within the configuration menu with a brief summary of the function. Please refer to the full instruction manual for detailed configuration information and for description of optional outputs. Access to the configuration menu is obtained by pressing the ( and ) buttons simultaneously. If the Rate Totaliser's security code is set to default 0000 the first parameter function will be displayed. If the instrument is protected by a security code, code will be displayed. The four digit code must be entered to gain access to the menu. Unless otherwise specified menu functions are shown on the upper display Alarms functions appear here 4/20mA output functions appear here () ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) & function * & input * & update * & di5p-1 * & di5p-2 * & dp * & factor * & 5cale-t * & 5cale-r * & t-ba5e * & filter * & clp off * & loc clr * & pul5e op * & clrgtot * & code * * & r5et def () () ) () () () () () () () () () () () ) ( () () () 5td inp. type * & debounce 0 . 5 total on 00000000 001 . 00 001 . 00 001 . 00 tb-01 24 000 . 0 clr tot * & clr gtot clr. no 0000 0000 () () () () () op. col default off off 0000 Function & or * to select Function of rate totaliser 5td Linear lin 16 segment lineariser Input Debounce & or * to select Input type op. col Open Collector. volt5 l Pulse <1V >3V volt5 h Pulse <3V >10V coil Magnetic pick-off. pr. det Proximity detector. contact Switch contact. & or * to select level of debounce. default heavy light Update & or * to select interval between display updates, may be set to 0.5, 1, 2, 3, 4 or 5 seconds Upper Display & or * to select whether rate or total is shown on the upper display Lower Display & or * to turn lower display on or off Decimal point & or * to select position of decimal point and ( to toggle between rate and total displays K-factor & or * to select value and ( to move to next digit or decimal point Note: When lin is selected 16 values for factor may be entered Total scale factor Divides factor to produce total display Press & or * to adjust value and ( to move to next digit or decimal point Rate scale factor Divides factor to produce rate display Press & or * to adjust value and ( to move to next digit or decimal point Timebase & or * to select rate display timebase tb-01 for flow/sec tb-60 for flow/min tb-3600 for flow/hour Filter & or * to adjust value of each digit and ( to transfer control to other digit First digit: filter magnitude second digit: step response Note: While making adjustments the filtered rate display is shown on lower display so stability can be assessed Clip off Rate display below which totalisation is inhibited Press & or * to adjust value of each digit and ( to move to next digit Local total reset & or * to turn the local total reset function on or off. When on, total display is reset to zero when & and * are operated simultaneously in display mode for more than 3 seconds Local grand total reset & or * to turn the local grand total reset function on or off. When on, grand total display may be reset to zero when ) and * are operated simultaneously in display mode for more than 10 seconds & Clear grand total Press & or * to select ye5 to reset grand total to zero Confirm instruction by entering 5ure. Press & or * to adjust each digit and ( to move to next digit Define Security Code Enter by pressing & or * and ( to move to next digit Reset configuration to factory defaults Confirm instruction by entering 5ure. Press & or * to adjust each digit and ( to move to next digit ) ) ) ) enbl * & 5ource * & divide * & duration * () () () () Fig 5 Configuration menu The BA334G is CE marked to show compliance with the European Explosive Atmospheres Directive 2014/34/EU and the European EMC Directive 2014/30/EU. It is also UKCA marked to show compliance with UK statutory requirements Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations UKSI 2016:1107 (as amended) and with the Electromagnetic Compatibility Regulations UKSI 2016:1091 (as amended). Manuals and datasheets can be downloaded from http://www.beka.co.uk/ba334g Fig 5 Configuration menu off 5caled 1000 0 .1 Pulse Enable * or & to toggle between on and oFF Source or Divides scaled output pulse output pulse Duration of each pulse * or & to select pulse source. 5CALEd Input pulse frequency may be divided and duration extended. OR dirECt Synchronous retransmission of input pulse without scaling * or & to select frequency dividing factor for scaled output pulse 1 10 100 1000 10000 * or & to select duration of scaled output pulse in ms 0 . 1 0 . 5 1 2 . 5 5 10 25 50 100 250 500 These functions only appear in sub-menu when pulse 5ourCE is configured as 5CALEd