PA5Z 13.4 SEER2 Single-Packaged Air Conditioner System

Single Phase, 2 to 5 Nominal Tons (Sizes 024-060)

Owner's Information Manual

This manual provides essential information for the owner of the Carrier PA5Z Single-Packaged Air Conditioner System.

Unit Overview

The PA5Z is a 13.4 SEER2 rated single-packaged air conditioner system designed for single-phase power. It is available in sizes ranging from 2 to 5 nominal tons, corresponding to model sizes 024 through 060.

Figure 1 shows two views of the PA5Z unit. The unit on the left is representative of sizes 024-048, and the unit on the right is representative of size 060.

Diagram Description: Two illustrations of rectangular outdoor air conditioning units are shown. The left unit is labeled '024-048' and the right unit is labeled '060'. Both units feature top-mounted fan grilles and side louvers.

For the Equipment Owner

For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.

UNIT INFORMATION

Model #: _________________________

Serial #: _________________________

ACCESSORIES (List type of model #): _________________________

INSTALLATION INFORMATION

Date Installed: _________________________

DEALERSHIP CONTACT INFORMATION

Company Name: _________________________

Address: _________________________

Phone Number: _________________________

Technician Name: _________________________

NOTE TO INSTALLER: This manual must be left with the equipment owner.

Disclaimer: Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.

Safety Considerations

This unit is equipped with electrically powered safety measures. For the safety measures to be effective, the unit must be electrically powered at all times after installation, other than when servicing.

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Auxiliary devices which may be a POTENTIAL IGNITION SOURCE shall not be installed in the duct work. Examples of such POTENTIAL IGNITION SOURCES are hot surfaces with a temperature exceeding 1292°F (700°C) and electric switching devices.

Electrostatic air purifiers installed in the ductwork are permitted, if the purifier has an airflow sensor.

False ceilings or drop ceilings must not be used as a return air duct/plenum.

Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit.

Consult local building codes, the current editions of the National Electrical Code (NEC) NFPA 70 and NFPA 90B-Installation Warm Air Heating and A/C Systems (Residential).

In Canada, refer to the current editions of the Canadian Electrical Code CSA C22.1.

Recognize safety information. This is the safety-alert symbol ⚠️. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

⚠️ WARNING: FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury, death, and/or property damage. Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service this equipment.

⚠️ WARNING: FIRE, EXPLOSION HAZARD

Failure to follow this warning could result in personal injury, death, and/or property damage. Do not store or use combustible materials, gasoline, or other flammable vapors and liquids in the vicinity of this or any other appliance.

⚠️ WARNING: ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury and/or death. Before performing recommended maintenance, be sure the main power switch to the unit is turned off and a lock-out tag is installed.

⚠️ WARNING: ELECTRICAL SHOCK AND OPERATION HAZARD

Failure to follow this warning could result in personal injury, death or property damage. Do not use this unit if any part has been underwater. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system which has been under water.

⚠️ WARNING: ELECTRICAL SHOCK AND CUT HAZARD

Failure to follow this warning could result in personal injury, death or property damage. When removing access panels or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely careful and wear protective clothing, safety glasses, and gloves when handling parts or reaching into the unit.

To Start Unit:

  1. Turn on the electrical power supply to the unit.
  2. Select temperature and set system switch to desired mode.

To Shut Off Unit:

NOTE: If the unit is being shut down because of a malfunction, call your dealer as soon as possible.

  1. Set the temperature switch to OFF.
  2. Turn off the electrical power supply to the unit.

Cooling Mode

With the SYSTEM or MODE control set to COOL, your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected. On extremely hot days, your unit will run for longer periods at a time and have shorter "off" periods than on moderate days.

Supplemental Heat

Your system may also be equipped with a supplemental heating source such as electric heat. On cold days and nights, your system will automatically turn on the supplemental heat, as needed, in order to maintain the level of comfort you have selected. When the thermostat calls for supplemental heat, you may notice the indoor fan increase its speed.

Routine Maintenance

All routine maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish a standard procedure.

For your safety, keep the unit area clear and free of combustible materials, gasoline, and other flammable liquids and vapors.

To assure proper functioning of the unit, flow of condenser air must not be obstructed from reaching the unit. Clearance from the top of the unit is 48 in. (1219 mm). Clearance of at least 36 in. (914 mm) is required on sides except the power entry side (42 in. [1067 mm] clearance).

Maintenance and Care for the Equipment Owner

Before performing maintenance yourself, please carefully consider the following:

⚠️ WARNING: FIRE, EXPLOSION, ELECTRICAL SHOCK AND CUT HAZARD

Failure to follow this warning could result in personal injury, death or property damage.

  1. TURN OFF ELECTRICAL POWER TO YOUR UNIT BEFORE SERVICING OR PERFORMING MAINTENANCE.
  2. When removing access panels or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit. Wear safety glasses, gloves, and appropriate protective clothing.

Air Filters

The air filter(s) should be checked every 3 or 4 weeks and changed or cleaned whenever it becomes dirty. Dirty filters produce excessive stress on the blower motor and can cause the motor to overheat and shut down.

This unit must have air filters in place before it can be operated. These filters can be located in one of at least two places. In many applications, the installer will provide return air filter grilles mounted on the wall or ceiling of the conditioned structure. In the instance of filter grilles, the filters can simply be removed from the grille and replaced.

Table 1: Indoor Air Filter Data

Unit SizeFilter Size
02420x20x1 (508x508x25 mm)
03020x24x1 (508x610x25 mm)
036-04224x30x1 (610x762x25 mm)
048-06024x36x1 (610x914x25 mm)

If you have difficulty locating your air filter(s) or have questions concerning proper filter maintenance, contact your dealer for instructions. When replacing filters, always use the same size and type of filter that was supplied, originally, by the installer.

⚠️ CAUTION: UNIT OPERATION HAZARD

Failure to follow this caution may result in property damage. Never operate your unit without filters in place. An accumulation of dust and lint on internal parts of your unit can cause loss of efficiency and blower motor and/or compressor damage.

Fans and Fan Motors

Periodically check the condition of fan wheels and housings and fan-motor shaft bearings. No lubrication of condenser-or evaporator-fan bearings or motors is required or recommended.

Indoor and Outdoor Coils

Cleaning of the coils should only be done by qualified service personnel. Contact your dealer for the required annual maintenance.

Condensate Drain

The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your dealer.

Compressor

All compressors are hermetically sealed and do not require periodic maintenance.

Condenser Fan

⚠️ WARNING: PERSONAL INJURY AND UNIT DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or property damage. Do not insert sticks, screwdrivers, or any other object into revolving fan blades. The fan must be kept free of all obstructions to ensure proper cooling. Contact your dealer for any required service.

Electrical Controls and Wiring

Electrical controls are difficult to check without proper instrumentation. If there are any discrepancies in the operating cycle, contact your local dealer and request service.

Refrigerant Circuit

The refrigerant circuit is difficult to check for leaks without the proper equipment. If inadequate cooling is suspected, contact your local dealer for service.

⚠️ WARNING: EXPLOSION, BURN AND ENVIRONMENTAL HAZARD

Failure to follow this warning could result in personal injury, death or property damage. System under pressure. Relieve pressure and recover all refrigerant before system repair or final unit disposal. Use all service ports and open all flow-control devices, including solenoid valves.

Unit Panels

After performing any maintenance or service on the unit, be sure all panels are fastened securely in place to prevent rain from entering the unit cabinet and to prevent disruption of the correct unit airflow pattern.

Regular Dealer Maintenance (Also refer to Table 2)

In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (preferably each year) should include the following:

  1. Inspection and, if required, cleaning of the indoor coil condensate drain.
  2. Inspection and, if required, cleaning of the evaporator drain pan.
  3. Inspection and cleaning of blower wheel housing and motor.
  4. Inspection of all supply-air and return-air ducts for leaks, obstructions, and insulation integrity. Any problems found should be resolved at this time.
  5. Inspection of the unit base to ensure that no cracks, gaps, etc., exist which may cause a hazardous condition.
  6. Inspection of the unit casing for signs of deterioration.
  7. Inspection of all electrical wiring and components to ensure proper connection.
  8. Inspection for leaks in the refrigerant circuit. Pressure-check to determine appropriate refrigerant charge.
  9. Operational check of the unit to determine working conditions. Repair or adjustment should be made at this time.

Warranty and Service

Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further details.

Complete service instructions can be found in the unit Installation, Start-up and Service Instructions.

Warranty Certificate

Your unit has a limited warranty. Be sure to read the warranty carefully to determine the coverage for your unit.

Before you call for service...

...check for several easily-solved problems.

If insufficient heating or cooling is suspected:

If your unit is not operating at all, check the following list for easy solutions:

In Case of Trouble

If you perform the steps above and unit performance is still unsatisfactory, shut off the unit and call your dealer.

Dealer's Name:

_________________________

Telephone:

_________________________

Unit Model:

_________________________

Unit Serial Number:

_________________________

Table 2: Maintenance Checklist

Monthly maintenance items and outdoor unit rinsing may be performed by the consumer. All other maintenance items and all service work must be performed by a qualified service technician. Read all Warning labels.

Consumer specific:Description of MaintenanceRecommended IntervalMonthlyAnnual
Inspect, clean, or replace air filter if filter is located indoors in return air duct.X
Clear away debris and vegetation near unit.X
Dealer specific:Inspect cabinet and basepan for damage. Replace panels, gaskets, and other components that are damaged or severely rusted. Make sure precipitation has not entered indoor section of unit.X
Inspect electrical disconnect for proper function. Repair or replace as necessary.X
Inspect electrical wiring and connections. Tighten loose connections. Inspect and perform functional test of equipment as needed to ensure proper function. Repair or replace damaged or overheated components and wiring.X
Inspect electric heater, if installed. Check for signs of overheating of elements, controls, and wiring. Make sure heater elements are not broken or electrically shorted.X
Check refrigerant system subcooling and/or superheat (system dependent).X
Inspect inside of unit. Clean if debris is present.X
Inspect condenser coil. Clean if dust, dirt, or debris is present. Rinse unit with fresh water (see Note 2).X
Inspect condenser motor and fan for damage. Make sure fan spins freely.X
Inspect and clean blower assembly (includes blower housing, wheel, and motor).X
Inspect evaporator coil. Clean if dust, dirt, or debris is present (see Note 2).X
If unit is charged with R-454B refrigerant, inspect and test leak dissipation system. See Installation and Service Instructions for details.X
Clean condensate pan and drain lines (more frequent maintenance may be required in humid climates).X
Inspect airflow system (ductwork). Check for leaks and repair as needed.X

Notes:

  1. The above list may not include all maintenance items. Inspection intervals may vary depending on climate and operating hours. Consult your HVAC dealer about a service contract for seasonal inspections.
  2. Do not use harsh chemicals or high pressure water on coils. More frequent rinsing is required for units near a sea coast.
Models: 024-048, A10165, A150067, 060, PA5Z Single Packaged Air Conditioner System, PA5Z, Single Packaged Air Conditioner System, Packaged Air Conditioner System, Air Conditioner System, Conditioner System

File Info : application/pdf, 4 Pages, 375.30KB

PDF preview unavailable. Download the PDF instead.

OG-PA5Z-01 Adobe PDF Library 15.0

Related Documents

Preview Carrier PH5ZNB 13.4 SEER2 Single-Packaged Heat Pump System Owner's Manual
Comprehensive owner's information manual for the Carrier PH5ZNB 13.4 SEER2 single-packaged heat pump system with R-454B refrigerant. Includes safety, operation, maintenance, and troubleshooting guides.
Preview Carrier PAM4 and WJA5 Air Conditioner Owner's Manual
Owner's information manual for the Carrier PAM4 and WJA5 13.4 SEER2 single-packaged air conditioner system with R-454B refrigerant. Includes safety, operation, and maintenance guidelines.
Preview Carrier 50NT-B Heat Pump Installation Instructions
Comprehensive installation guide for the Carrier 50NT-B Comfort™ 13.4 SEER2 Single-Packaged Heat Pump System with Puron Advance™ (R-454B) refrigerant. Covers safety, receiving, installation, start-up, maintenance, troubleshooting, and decommissioning.
Preview Carrier 26SCA5 Comfort™ Series Air Conditioner Product Data
Explore the Carrier 26SCA5 Comfort™ Series Single-Stage Air Conditioner, featuring Puron Advance™ Refrigerant. This document provides detailed product data, features, benefits, specifications, and performance ratings for various models.
Preview PA5SAN5 Single-Stage Air Conditioner Product Data
Product data and specifications for the PA5SAN5 single-stage air conditioner, featuring R-454B refrigerant. Includes features, benefits, reliability, durability, applications, warranty information, technical data, dimensions, and clearances.
Preview Carrier 26SPA6 Performance Series Air Conditioner Product Data
Detailed product data for the Carrier 26SPA6 Performance Series single-stage air conditioner, featuring Puron Advance™ refrigerant, MicroChannel technology, and InteliSense™ technology. Includes specifications, ratings, and features for 1-1/2 to 5 ton models.
Preview R5A5S Single-Stage Air Conditioner Product Specifications
Detailed product specifications for the R5A5S Single-Stage Air Conditioner with R-454B Refrigerant, covering efficiency, comfort, reliability, durability, applications, and warranty information. Includes model nomenclature, ordering numbers, standard features, physical data, refrigerant piping limitations, and cooling capacities.
Preview Carrier 26SCA5 Comfort Series Single-Stage Air Conditioner Product Data
Detailed product data for the Carrier 26SCA5 Comfort Series single-stage air conditioner, featuring Puron Advance™ refrigerant, high efficiency ratings (SEER2/EER2), Microchannel Technology, and WeatherArmor™ Protection. Includes specifications, model numbers, and performance data.