User Manual for HUANYA models including: HF5, HF5 Tuya WiFi Fingerprint Access Control and Reader, Tuya WiFi Fingerprint Access Control and Reader, WiFi Fingerprint Access Control and Reader, Fingerprint Access Control and Reader, Access Control and Reader, Reader
Huanya Intelligent Technology Shenzhen Co., LTD TF108 Tuya wifi Fingerprint Access Control 2BPAN-TF108 2BPANTF108 tf108
Huanya Intelligent Technology Shenzhen Co., LTD HF5 Tuya wifi Fingerprint Access Control 2BPAN-HF5 2BPANHF5 hf5
File Info : application/pdf, 2 Pages, 186.03KB
DocumentDocumentFingerprint Access Control & Reader Fingerprint Wifi CARD Card/ PIN Smart phone open copy Open door by multi-user Visitor users unlock Copy user date Waterproof 12 34 56 78 90 *# Anti-vandal Wiegand Wiegand data User Manual INTRODUCTION This device is a new generation metal waterproof fingerprint & RFID card standalone access control. It has the zinc alloy housing which is anti-explosion and anti-vandal. Conforms to waterproof IP66 which is suitable for outdoor use. Support 100 or 500 fingerprint users and 10000 card/code users. Support fingerprint/card/code/multi-users/temporary visitor users opening the door. And can be set as the card reader. Support upload and download the data of card & PIN code users. It has the door contact detection and anti-tamper functions. Supports OTA online upgrade ( The users can upgrade their devices by themselves if there is better functional applications) Specifications Fingerprint User Card User/ PIN User Operating Voltage Idle Current Active Current Card Type Card Frequency Read Range Operating Temperature Operating Humidity 100 or 500 10000 DC10-24V 50mA 120mA EM/ Mifare card 125KHz/ 13.56MHz 60mm -20+60 10%99% Carton Inventory Advantages and Features Smart phone management, Smart phone open (WiFi has this feature) Supports OTA online upgrade (WiFi has this feature) Smart phone door status check (WiFi has this feature) Set the temporary PIN code with APP Access Mode: fingerprint, card, PIN, multi users Wiegand 26-44 bits, 56 bits, 58 bits Input/output PIN Wiegand output formats: 4 bits, 8 bits(ASCII), 10 digits virtual card number. Pulse Mode and Toggle Mode 01 12 34 56 78 90 *# L129xW44xH20 L130xW46xH16 (mm) (mm) L115xW76xH25(mm) L115xW70xH19(mm) Admin Card Admin Cards Self Tapping Screws Wall Anchors 02 Screw Driver Diode 1N4004 INSTALLATION 1. Draw the location of the hole and drill the hole on the installation position according to the hole of the back cover. 2. Fix the back cover on the wall with the wall anchors in the accessories bag. 3. Thread the cable through cable hole, connect related cable. For the un-used cable please separate with insulating tape. 4. Cover the front cover and fix the front and back cover together with screwdriver and screws. 12 34 56 78 90 *# 12 34 56 78 90 *# Wires Definition NO. Function Colour Notes 1 NC Orange Relay NC 2 COM Purple Relay COM 3 NO Blue Relay NO 4 GND Black Negative Pole 5 DC+ Red 10-24V DC Power Input 6 OPEN Yellow Exit Button 7 D_IN Brown Door Contact 8 ALARM- Grey Connect to external alarm negative pole 9 D0 Green Wiegand Output/Input Data 0 10 D1 White Wiegand Output/ input Data 1 11 BELL Pink External doorbell 12 BELL Pink External doorbell 03 Sound and Light Indication Operation Status LED Standby Mode Red light bright Enter program Mode Red light shines In the Program Mode Orange light bright Open lock Green light bright Operation failed ---- Buzzer ---- ---- ---- One beep Three beeps Administrator's Code, Fingerprint and Card Name Function Admin Code Enter into Program Mode Admin Fingerprint/Card Add User Rapidly Delete User Rapidly Modify Admin Code Programming Step Keystroke Combination LED * Enter Program Mode Admin Code # 0# (New Admin Code) # Modify Admin Code (Repeat New Admin Code) # (Factory Default is 123456) Red shines Orange bright * Exit Program Mode Red bright Note: The Admin Code can be any 6 digits and the admin must keep it in mind. Set Factory Default and Set Admin Card/ Fingerprint Press and hold the exit button, power on, release it after two beeps. Swipe the admin card, press the admin fingerprint 3 times, the red led on with one beep, the factory default setting done. And the admin card/ admin fingerprint added successfully. The admin card/ admin fingerprint has the function of adding/ deleting users. 04 Note: 1. Reset to factory default, the users' information won't be deleted. 2. If you don't want to add admin card/fingerprint: press and hold the Exit Button for 5 seconds, release it until hear one long beep and the red light bright. Tuya app Smart phone unbinding Wifi Programming Step Keystroke Combination LED Enter Program Mode WiFi unbinding * Admin Code # 90# (Admin Code) # Red shines Orange bright Exit Program Mode * Red bright Note: 1.WiFi unbinding: with this operation, the device will disconnect with all the smart phones, the phone can't control the device at the time. STANDALONE MODE Connection Diagram Special Power Supply NO NC COM DC+ OPEN D_IN ALARMD0 D1 GND Blue Orange Purple Red Exit button Yellow Brown Grey Door contact Green White Black Alarm Access control Magnetic Lock or + Fail-Safe Lock - Fail-secure K- lock K+ PUSH GND +12V NC GND COM NO Door contact Alarm Optional 05 Special Power Supply 1N4004 1N4004 DC Power Supply Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing). NO NC COM DC+ OPEN D_IN ALARMD0 D1 GND Blue Orange Purple Red Yellow Exit button Brown Grey Door contact Green White Black Access control - Magnetic Lock or Fail-Safe + Lock Fail-secure lock + GND 10-24V DC DC Power Supply Alarm Door contact Alarm Optional Usage of Admin Add/Delete Card and Fingerprint Using Admin cards to add and delete users Step 1: Read Admin card or press Admin fingerprint Add users Step 2: Read user card or press the fingerprint 3 times. (Repeat step 1 for additional users) Step 3: Read Admin card or press Admin fingerprint again to end Step 1: Read Admin card or press Admin fingerprint twice at the standby mode Delete users Step 2: Read user cards or press fingerprint (Repeat step 1 for additional users) Step 3: Read Admin card or press Admin fingerprint again to end 06 Simplified Instruction Enter the Programming Mode * - Admin Code-# Then you can do the programming (Factory default is 123456) Modify Admin Code 0# (New Admin Code) # (Repeat New Admin Code)# (The Admin Code can be any 6 digits) Add Users 1# - Read Card/ Press Fingerprint Note: When adding users, each fingerprint should be pressed once (or three) in succession. Delete Users 2# - Read Card/ Press Fingerprint * Exit from the Programming Mode How to release the door Open door by Fingerprint (Fingerprint) Open door by card (Read Card) Open door by User PIN (Users PIN) # Open door by user card + PIN (Read Card) (Users PIN) # Add Users Programming Step Keystroke Combination * Enter Program Mode Admin Code # Add Card/ PIN Users Add Card User: By Card 1# (Read Card)... Add Card User: By Card 1# (Input 8/10 digits card Number number) #... Add PIN Users 1# (4~6 digits PIN) # ... Add Fingerprint Users Add Fingerprint User: 1# (Fingerprint) ... (Press By Fingerprint each fingerprint 3 times) LED Red shines Orange bright Orange bright 4. User Fingerprint ID range: 1-100 or 1-500, User Card or Code ID range: 1-9988, Anti-duress users ID: 99899990, Visitor users ID range: 9991-10000. Add proximity cards sequentially numbered Programming Step Keystroke Combination LED * Enter Program Mode Admin Code # Red shines Add proximity cards 10# (Input the first ID number) # sequentially (card quantity) # (The first card numbered number) # Orange bright * Exit Program Mode Red bright Note: The ID number must be empty and successive. ID Number Add Users Programming Step Keystroke Combination LED * Enter Program Mode Admin Code # Add Card/ PIN Users Red shines Add Card User 10# ID# (Read Card)... Add Card User: By Card 10# ID# (Input 8/10 digits Number card number) #... Orange bright Add PIN Users 10# ID# (4~6 digits PIN) # ... Add Fingerprint Users Add Fingerprint User: 11# ID# (Fingerprint) ... (Press Orange By Fingerprint each fingerprint 3 times) bright Note: 1. The ID number is a number assigned to each user and it is usually useless. But when you want to delete specific user, you should input the ID number or card number. 2. When adding users, the ID number will be assigned automatically from small to big. 3. Add fingerprint users: Every fingerprint should be pressed 3 in times. 07 Add Visitor Users Programming Step Keystroke Combination LED * Enter Program Mode Admin Code # Red shines Add Visitor Card 10# ID# (1~9)# Read Card Orange Add Visitor PIN 10# ID# (1~9)# (4~6 digits PIN)# bright * Exit Program Mode Red bright Note:Visitor users ID range: 9991~10000, Number of time is 1~9. Delete User Programming Step Keystroke Combination Enter Program Mode * Admin Code # Delete Card User: By Card 2# (Read Card) ... Delete User: By Fingerprint 2# (Fingerprint) ... Delete Card User: By Card 2# (Input 8/10 digits card number number) # ... Delete PIN User 2# (4~6 digits PIN) # ... 08 LED Red Orange bright Delete Card/ PIN User: By ID number 20# (Input ID number) # ... Delete All Card/ PIN User Delete Fingerprint User: By ID number 20# (Admin Code) # 21# (Input ID number) # ... Orange bright Delete All Fingerprint User 21# (Admin Code) # Delete All User 2# (Admin Code) # Exit Program Mode * Red Note: User Fingerprint ID range: 1-100 or 1-500, User Card or Code ID range: 1-9988, Anti-duress users ID: 99899990, Visitor users ID range: 9991-10000. Change the user code Standby mode * ID# old code # new code # new code # Exit the programming mode Automatically exit when change done Pulse Mode and Toggle Mode Setting Programming Step Keystroke Combination LED * Enter Program Mode Admin Code # Red shines Access Time Setting 3# (0~180) # (Factory default is Pulse Mode) Orange bright Set Toggle Mode 3# 9999# * Exit Program Mode Red bright Note: 1. Pulse Mode and Toggle Mode, you only can choose one. 2. Factory default is Pulse Mode, and access time is 5 seconds. 0 seconds=100MS. 3. Pulse Mode: The door will be closed automatically after opening the door for a while. Toggle Mode: Under this mode, after opening the door, the door won't be closed automatically until next valid user input. That's means whether open or close the door, you must swipe valid card or input valid fingerprint. 09 Access Mode Setting Programming Step Keystroke Combination LED Enter Program Mode Open door by card * Admin Code # 4# 0# Red shines Open door by code 4# 1# Open door by Fingerprint Open door by card+ code Open door by multi-user 4# 2# 4# 4# 4# (42~49) # Orange bright Open door by card or code or Fingerprint 4# 3# (Factory Default) Exit Program Mode * Red bright Note: The number of Multi-User access can be set to 2~9. If the user number is set to 9, it should input 9 different valid users continuously to access, and the time interval of inputting two valid user should be less than or equal 10s. If timeout, the device will exit to standby mode automatically. During the operation the red led light shines. Alarm output Time Setting (Factory default is 1 minute) Programming Step Keystroke Combination LED * Enter Program Mode Admin Code # Set alarm time 30# (0~3)# Red shines Orange bright Exit Program Mode * Red bright Note: Alarm time range: 1~3 minutes, 0: Turn off alarm, and it includes door contact alarm, tamper alarm, and the time alarm of safe mode. Door Detection Setting Programming Step Keystroke Combination Enter Program Mode * (Admin Code) # To disable door detection 50# 0# (Factory Default) To enable door detection 50# 1# LED Red shines Orange bright 10 To enable door not closed detection 51# 0# To disable door not closed detection 51# 1# (Factory Default) Orange bright Exit Program Mode * Red bright Note: After enable the door detection function, you must connect the detection switch into the wiring. There will be two detection status: 1. The door is opened by valid user, but not closed in 1 minute, the device will beep. How to stop the warnings: Close the door/valid user/ Automatically stop when the alarm time is up. 2. If the door opened by force, the device and external alarm will activate. How to stop the alarm: Valid user/Automatically stop when the alarm time is up. Safe Mode Setting Programming Step Keystroke Combination LED Enter Program Mode Close safe Mode * Admin Code # 5# 0# (Factory default) Red shines Lockout Mode 5# 1# Orange bright Alarm output Mode 5# 2# Exit Program Mode * Red bright Note: Lockout Mode: If swipe card/input fingerprint with invalid users for 10 times in 10 minute, the device will be lockout for 10 minutes. When in Lockout Mode, press the Exit Button can open the door. Alarm Output: If swipe card/input fingerprint with invalid users for 10 times in 10 minute, the device will beep and external alarm will activate. The valid user can remove the alarm. 11 Sound and Light mode Setting Programming Step Keystroke Combination LED Enter Program Mode Control Sounds: OFF ON * Admin Code # 6# 0# 6# 1# (Factory Default) Red shines Control Red LED: OFF ON Control Keypad LED: OFF ON Intelligent keyboard light 60# 0# 60# 1# (Factory Default) 61# 0# 61# 1# (Factory Default) 61# 2# Orange bright Anti-tamper Alarm: OFF ON 52# 0# (Factory Default) 52# 1# Exit Program Mode * Red bright Data transmission of user card & user code Programming Step Keystroke Combination LED Enter Program Mode Enter the menu * Admin Code # 9# 1# Red shines Orange bright Exit Program Mode * Red bright Note: (Only support copy user of card and code) 1. The two devices must be the device produced by us and support this function. 2. The two devices have the same admin code 3. Connect the Wiegand cable of the two devices and power on For example: For device A and B, they have the same admin code. Add a new card & code user to the device A. Device B has no user. Connect the Wiegand cable of device A and B, then power on. Do the operation of * admin code # 9# 1# on device A. The green led of the two devices flash. The device A is sending the user data to device B. 12 WIEGAND READER MODE Connection Diagram 12 34 Red Black DC+ GND 56 78 Green D0 90 White D1 *# Brown GREEN LED Yellow BUZZER Reader Controller Set standalone / Wiegand reader mode Programming Step Keystroke Combination LED Enter Program Mode Standalone Mode * Admin Code # 8# 0# (Factory Default) Wiegand reader Mode 8# 1# Red shines Orange bright Exit Program Mode * Red bright Note: In wiegand reader mode, brown wire control the Green LED, Yellow wire control the buzzer, only active with low voltage. Wiegand Format Setting (Factory Default: EM 26 bit, Mifare 34 bit, Password 4 bit) Programming Step Keystroke Combination LED Enter Program Mode * Admin Code # Red Wiegand check code: OFF 7# 0# ON 7# 1# (Factory Default) Password Wiegand Format 70# (0# or 4# or 8#) EM Wiegand format 71# (26# ~ 44#) Mifare Wiegand format 72# (26#~44#, 56#, 58#) Orange bright Exit Program Mode * Red Note: (1) 10 Digits Virtual Card Number: Input 4~6 digits PIN, press "#", output a 10-bit decimal card number. For example, input password 999999, the output card number is 0000999999. 13 (2) Each key press sends 4 bits data, the corresponding relationship is: 1 (0001) 2 (0010) 3 (0011) 4 (0100) 5 (0101) 6 (0110) * 7 (0111) 8 (1000) 9 (1001) (1010) 0 (0000) # (1011) (3) Each key press sends 8 bits data, the corresponding relationship is: 1 (1110 0001) 2 (1101 0010) 3 (1100 0011) 4 (1011 0100) 5 (1010 0101) 6 (1001 0110) 7 (1000 0111) 8 (0111 1000) * 9 (0110 1001) (0101 1010) 0 (1111 0000) # (0100 1011) INTERLOCK MODE Interlock for two doors, this function usually apply in the places with high safety. For example, there are two doors name A and B in the passage. You access door A with card, and then you cannot access door B with the card until door A closed. That is to say: both of the doors should be closed, then you can swipe your card on one of them. Programming Step Keystroke Combination LED * Enter Program Mode Admin Code # Close Interlock Mode 80# 0# (Factory Default) Enable Interlock Mode 80# 1# Red shines Orange bright Exit Program Mode * Red bright Note: The Door Contact must be installed, or this function cannot be enable. Wiring diagram of Interlock 1n4004 1n4004 1n4004 1n4004 NO NC COM DC+ OPEN ALARMD0 D1 GND D_IN Blue Orange Purple Magnetic Lock or Fail-Safe Lock + K- Fail-secure lock K+ - Fail-secure lock + K- Magnetic Lock or Fail-Safe Lock K+ Red Exit button Yellow Grey Green White Black Brown Power Supply GND +12V Door contact Door contact Passageway A Gold B Warehouse A Control Blue Orange Purple Red Exit button Yellow Grey Green White Black Brown NO NC COM DC+ OPEN ALARMD0 D1 GND D_IN B Control 14 FCC Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC's RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.Corel PDF Engine Version 14.0.0.701 CorelDRAW