User Manual for HUANYA models including: HF5, HF5 Tuya WiFi Fingerprint Access Control and Reader, Tuya WiFi Fingerprint Access Control and Reader, WiFi Fingerprint Access Control and Reader, Fingerprint Access Control and Reader, Access Control and Reader, Reader

WIFI指纹机英文说明书 OTA功能 100X70mm

admin

User Manual

Huanya Intelligent Technology Shenzhen Co., LTD TF108 Tuya wifi Fingerprint Access Control 2BPAN-TF108 2BPANTF108 tf108

Huanya Intelligent Technology Shenzhen Co., LTD HF5 Tuya wifi Fingerprint Access Control 2BPAN-HF5 2BPANHF5 hf5


File Info : application/pdf, 2 Pages, 186.03KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8345064
Fingerprint Access Control & Reader

Fingerprint

Wifi
CARD
Card/ PIN Smart phone open

copy

Open door by multi-user Visitor users unlock Copy user date

Waterproof

12 34 56 78 90 *#
Anti-vandal

Wiegand Wiegand data

User Manual

INTRODUCTION
This device is a new generation metal waterproof fingerprint & RFID card standalone access control. It has the zinc alloy housing which is anti-explosion and anti-vandal. Conforms to waterproof IP66 which is suitable for outdoor use. Support 100 or 500 fingerprint users and 10000 card/code users. Support fingerprint/card/code/multi-users/temporary visitor users opening the door. And can be set as the card reader. Support upload and download the data of card & PIN code users. It has the door contact detection and anti-tamper functions.
Supports OTA online upgrade ( The users can upgrade their devices by themselves if there is better functional applications)

Specifications
Fingerprint User Card User/ PIN User Operating Voltage Idle Current Active Current Card Type Card Frequency Read Range Operating Temperature Operating Humidity

100 or 500 10000
DC10-24V 50mA 120mA EM/ Mifare card 125KHz/ 13.56MHz 60mm -20+60 10%99%

Carton Inventory

Advantages and Features Smart phone management, Smart phone open (WiFi has this feature)
Supports OTA online upgrade (WiFi has this feature)
Smart phone door status check (WiFi has this feature)
Set the temporary PIN code with APP Access Mode: fingerprint, card, PIN, multi users Wiegand 26-44 bits, 56 bits, 58 bits Input/output
PIN Wiegand output formats: 4 bits, 8 bits(ASCII), 10 digits virtual card number. Pulse Mode and Toggle Mode
01

12 34 56 78 90 *#

L129xW44xH20 L130xW46xH16

(mm)

(mm)

L115xW76xH25(mm)

L115xW70xH19(mm)

Admin Card Admin Cards

Self Tapping Screws Wall Anchors 02

Screw Driver Diode 1N4004

INSTALLATION
1. Draw the location of the hole and drill the hole on the installation position according to the hole of the back cover.
2. Fix the back cover on the wall with the wall anchors in the accessories bag.
3. Thread the cable through cable hole, connect related cable. For the un-used cable please separate with insulating tape.
4. Cover the front cover and fix the front and back cover together with screwdriver and screws.

12 34 56 78 90 *#

12 34 56 78 90 *#

Wires Definition

NO. Function Colour Notes

1 NC

Orange Relay NC

2 COM

Purple Relay COM

3 NO

Blue Relay NO

4 GND

Black Negative Pole

5 DC+

Red 10-24V DC Power Input

6 OPEN Yellow Exit Button

7 D_IN

Brown Door Contact

8 ALARM- Grey Connect to external alarm negative pole

9 D0

Green Wiegand Output/Input Data 0

10 D1

White Wiegand Output/ input Data 1

11 BELL Pink External doorbell

12 BELL Pink External doorbell

03

Sound and Light Indication

Operation Status

LED

Standby Mode

Red light bright

Enter program Mode Red light shines

In the Program Mode Orange light bright

Open lock

Green light bright

Operation failed

----

Buzzer ---- ---- ----
One beep Three beeps

Administrator's Code, Fingerprint and Card

Name

Function

Admin Code

Enter into Program Mode

Admin Fingerprint/Card

Add User Rapidly Delete User Rapidly

Modify Admin Code

Programming Step Keystroke Combination

LED

* Enter Program Mode Admin Code # 0# (New Admin Code) # Modify Admin Code (Repeat New Admin Code) #
(Factory Default is 123456)

Red shines
Orange bright

* Exit Program Mode

Red bright

Note: The Admin Code can be any 6 digits and the admin must keep

it in mind.

Set Factory Default and Set Admin Card/ Fingerprint Press and hold the exit button, power on, release it after two beeps. Swipe the admin card, press the admin fingerprint 3 times, the red led on with one beep, the factory default setting done. And the admin card/ admin fingerprint added successfully.
The admin card/ admin fingerprint has the function of adding/ deleting users.

04

Note:
1. Reset to factory default, the users' information won't be deleted.
2. If you don't want to add admin card/fingerprint: press and hold the Exit Button for 5 seconds, release it until hear one long beep and the red light bright.

Tuya app Smart phone unbinding

Wifi

Programming Step Keystroke Combination

LED

Enter Program Mode WiFi unbinding

* Admin Code #
90# (Admin Code) #

Red shines Orange bright

Exit Program Mode

*

Red bright

Note: 1.WiFi unbinding: with this operation, the device will

disconnect with all the smart phones, the phone can't control the

device at the time.

STANDALONE MODE
Connection Diagram Special Power Supply

NO NC COM DC+ OPEN D_IN ALARMD0 D1 GND

Blue Orange Purple
Red Exit button
Yellow Brown Grey Door contact Green White Black

Alarm

Access control

Magnetic

Lock or

+

Fail-Safe Lock

-

Fail-secure K-

lock

K+

PUSH GND +12V NC GND COM NO

Door contact Alarm Optional

05

Special Power Supply 1N4004 1N4004

DC Power Supply
Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing).

NO NC COM DC+ OPEN D_IN ALARMD0 D1 GND

Blue Orange Purple
Red Yellow Exit button Brown Grey Door contact
Green White Black

Access control

- Magnetic Lock or Fail-Safe
+ Lock

Fail-secure lock +
GND
10-24V DC
DC Power Supply

Alarm

Door contact Alarm Optional

Usage of Admin Add/Delete Card and Fingerprint Using Admin cards to add and delete users
Step 1: Read Admin card or press Admin fingerprint

Add users

Step 2: Read user card or press the fingerprint 3 times. (Repeat step 1 for additional users)

Step 3: Read Admin card or press Admin fingerprint again to end

Step 1: Read Admin card or press Admin fingerprint

twice at the standby mode

Delete users

Step 2: Read user cards or press fingerprint (Repeat step 1 for additional users)

Step 3: Read Admin card or press Admin fingerprint again to end

06

Simplified Instruction

Enter the Programming Mode

* - Admin Code-#
Then you can do the programming (Factory default is 123456)

Modify Admin Code

0# (New Admin Code) # (Repeat New Admin Code)# (The Admin Code can be any 6 digits)

Add Users

1# - Read Card/ Press Fingerprint
Note: When adding users, each fingerprint should be pressed once (or three) in succession.

Delete Users

2# - Read Card/ Press Fingerprint

* Exit from the Programming
Mode

How to release the door

Open door by Fingerprint

(Fingerprint)

Open door by card

(Read Card)

Open door by User PIN

(Users PIN) #

Open door by user card + PIN (Read Card) (Users PIN) #

Add Users

Programming Step

Keystroke Combination

* Enter Program Mode

Admin Code #

Add Card/ PIN Users

Add Card User: By Card 1# (Read Card)...

Add Card User: By Card 1# (Input 8/10 digits card

Number

number) #...

Add PIN Users

1# (4~6 digits PIN) # ...

Add Fingerprint Users

Add Fingerprint User: 1# (Fingerprint) ... (Press

By Fingerprint

each fingerprint 3 times)

LED Red shines
Orange bright
Orange bright

4. User Fingerprint ID range: 1-100 or 1-500, User Card or Code ID range: 1-9988, Anti-duress users ID: 99899990, Visitor users ID range: 9991-10000.

Add proximity cards sequentially numbered

Programming Step Keystroke Combination

LED

* Enter Program Mode Admin Code #

Red shines

Add proximity cards 10# (Input the first ID number) #

sequentially

(card quantity) # (The first card

numbered

number) #

Orange bright

* Exit Program Mode

Red bright

Note: The ID number must be empty and successive.

ID Number Add Users

Programming Step Keystroke Combination

LED

* Enter Program Mode

Admin Code #

Add Card/ PIN Users

Red shines

Add Card User

10# ID# (Read Card)...

Add Card User: By Card 10# ID# (Input 8/10 digits

Number

card number) #...

Orange bright

Add PIN Users

10# ID# (4~6 digits PIN) # ...

Add Fingerprint Users

Add Fingerprint User: 11# ID# (Fingerprint) ... (Press Orange

By Fingerprint

each fingerprint 3 times)

bright

Note: 1. The ID number is a number assigned to each user and it is usually useless. But when you want to delete specific user, you should input the ID number or card number.

2. When adding users, the ID number will be assigned automatically from small to big.

3. Add fingerprint users: Every fingerprint should be pressed 3 in times.

07

Add Visitor Users

Programming Step Keystroke Combination

LED

* Enter Program Mode Admin Code #

Red shines

Add Visitor Card

10# ID# (1~9)# Read Card

Orange

Add Visitor PIN

10# ID# (1~9)# (4~6 digits PIN)# bright

* Exit Program Mode

Red bright

Note:Visitor users ID range: 9991~10000, Number of time is 1~9.

Delete User

Programming Step

Keystroke Combination

Enter Program Mode

* Admin Code #

Delete Card User: By Card 2# (Read Card) ...

Delete User: By Fingerprint 2# (Fingerprint) ...

Delete Card User: By Card 2# (Input 8/10 digits card

number

number) # ...

Delete PIN User

2# (4~6 digits PIN) # ...

08

LED Red
Orange bright

Delete Card/ PIN User: By ID number

20# (Input ID number) # ...

Delete All Card/ PIN User
Delete Fingerprint User: By ID number

20# (Admin Code) # 21# (Input ID number) # ...

Orange bright

Delete All Fingerprint User 21# (Admin Code) #

Delete All User

2# (Admin Code) #

Exit Program Mode

*

Red

Note: User Fingerprint ID range: 1-100 or 1-500, User Card or Code ID range: 1-9988, Anti-duress users ID: 99899990, Visitor users

ID range: 9991-10000.

Change the user code

Standby mode

* ID# old code # new code # new code #

Exit the programming mode

Automatically exit when change done

Pulse Mode and Toggle Mode Setting

Programming Step Keystroke Combination

LED

* Enter Program Mode Admin Code #

Red shines

Access Time Setting 3# (0~180) # (Factory default is Pulse Mode)

Orange bright

Set Toggle Mode

3# 9999#

* Exit Program Mode

Red bright

Note: 1. Pulse Mode and Toggle Mode, you only can choose one.

2. Factory default is Pulse Mode, and access time is 5

seconds. 0 seconds=100MS.

3. Pulse Mode: The door will be closed automatically after opening the door for a while.

Toggle Mode: Under this mode, after opening the door, the door won't be closed automatically until next valid user input. That's means whether open or close the door, you must swipe valid card or input valid fingerprint.

09

Access Mode Setting

Programming Step

Keystroke Combination LED

Enter Program Mode Open door by card

* Admin Code #
4# 0#

Red shines

Open door by code

4# 1#

Open door by Fingerprint Open door by card+ code Open door by multi-user

4# 2# 4# 4# 4# (42~49) #

Orange bright

Open door by card or code or Fingerprint

4# 3# (Factory Default)

Exit Program Mode

*

Red bright

Note: The number of Multi-User access can be set to 2~9. If the

user number is set to 9, it should input 9 different valid users

continuously to access, and the time interval of inputting two

valid user should be less than or equal 10s. If timeout, the

device will exit to standby mode automatically. During the

operation the red led light shines.

Alarm output Time Setting (Factory default is 1 minute)

Programming Step Keystroke Combination

LED

* Enter Program Mode

Admin Code #

Set alarm time

30# (0~3)#

Red shines Orange bright

Exit Program Mode

*

Red bright

Note: Alarm time range: 1~3 minutes, 0: Turn off alarm, and it

includes door contact alarm, tamper alarm, and the time alarm of

safe mode.

Door Detection Setting

Programming Step

Keystroke Combination

Enter Program Mode

* (Admin Code) #

To disable door detection 50# 0# (Factory Default)

To enable door detection 50# 1#

LED Red shines
Orange bright

10

To enable door not closed detection

51# 0#

To disable door not closed detection

51# 1# (Factory Default)

Orange bright

Exit Program Mode

*

Red bright

Note: After enable the door detection function, you must connect

the detection switch into the wiring. There will be two

detection status:

1. The door is opened by valid user, but not closed in 1 minute, the device will beep.
How to stop the warnings: Close the door/valid user/ Automatically stop when the alarm time is up.

2. If the door opened by force, the device and external alarm will activate.
How to stop the alarm: Valid user/Automatically stop when the alarm time is up.

Safe Mode Setting

Programming Step Keystroke Combination

LED

Enter Program Mode Close safe Mode

* Admin Code #
5# 0# (Factory default)

Red shines

Lockout Mode

5# 1#

Orange bright

Alarm output Mode

5# 2#

Exit Program Mode

*

Red bright

Note: Lockout Mode: If swipe card/input fingerprint with invalid

users for 10 times in 10 minute, the device will be lockout for

10 minutes. When in Lockout Mode, press the Exit Button

can open the door.

Alarm Output: If swipe card/input fingerprint with invalid users for 10 times in 10 minute, the device will beep and external alarm will activate. The valid user can remove the alarm.

11

Sound and Light mode Setting

Programming Step

Keystroke Combination LED

Enter Program Mode
Control Sounds: OFF ON

* Admin Code #
6# 0# 6# 1# (Factory Default)

Red shines

Control Red LED: OFF ON
Control Keypad LED: OFF ON
Intelligent keyboard light

60# 0# 60# 1# (Factory Default)
61# 0# 61# 1# (Factory Default) 61# 2#

Orange bright

Anti-tamper Alarm: OFF ON

52# 0# (Factory Default) 52# 1#

Exit Program Mode

*

Red bright

Data transmission of user card & user code

Programming Step

Keystroke Combination

LED

Enter Program Mode Enter the menu

* Admin Code #
9# 1#

Red shines Orange bright

Exit Program Mode

*

Red bright

Note: (Only support copy user of card and code)

1. The two devices must be the device produced by us and support

this function.

2. The two devices have the same admin code

3. Connect the Wiegand cable of the two devices and power on

For example: For device A and B, they have the same admin code. Add a new card & code user to the device A. Device B has no user. Connect
the Wiegand cable of device A and B, then power on. Do the operation of * admin code # 9# 1# on device A. The green led of the two devices flash. The device A is sending the user data to device B.

12

WIEGAND READER MODE
Connection Diagram

12 34

Red Black

DC+ GND

56 78

Green

D0

90

White

D1

*#

Brown

GREEN LED

Yellow

BUZZER

Reader

Controller

Set standalone / Wiegand reader mode

Programming Step Keystroke Combination

LED

Enter Program Mode Standalone Mode

* Admin Code #
8# 0# (Factory Default)

Wiegand reader Mode 8# 1#

Red shines
Orange bright

Exit Program Mode

*

Red bright

Note: In wiegand reader mode, brown wire control the Green LED,

Yellow wire control the buzzer, only active with low voltage.

Wiegand Format Setting (Factory Default: EM 26 bit, Mifare 34 bit, Password 4 bit)

Programming Step

Keystroke Combination

LED

Enter Program Mode

* Admin Code #

Red

Wiegand check code: OFF 7# 0#

ON 7# 1# (Factory Default)

Password Wiegand Format 70# (0# or 4# or 8#)

EM Wiegand format

71# (26# ~ 44#)

Mifare Wiegand format

72# (26#~44#, 56#, 58#)

Orange bright

Exit Program Mode

*

Red

Note: (1) 10 Digits Virtual Card Number: Input 4~6 digits PIN, press "#", output a 10-bit decimal card number. For example, input password 999999, the output card number is 0000999999.

13

(2) Each key press sends 4 bits data, the corresponding relationship is: 1 (0001) 2 (0010) 3 (0011) 4 (0100) 5 (0101) 6 (0110)
* 7 (0111) 8 (1000) 9 (1001) (1010) 0 (0000) # (1011)
(3) Each key press sends 8 bits data, the corresponding relationship is:
1 (1110 0001) 2 (1101 0010) 3 (1100 0011) 4 (1011 0100) 5 (1010 0101) 6 (1001 0110) 7 (1000 0111) 8 (0111 1000)
* 9 (0110 1001) (0101 1010) 0 (1111 0000) # (0100 1011)

INTERLOCK MODE
Interlock for two doors, this function usually apply in the places

with high safety. For example, there are two doors name A and B in the passage. You access door A with card, and then you cannot

access door B with the card until door A closed. That is to say: both of the doors should be closed, then you can swipe your card on one of them.

Programming Step Keystroke Combination

LED

* Enter Program Mode

Admin Code #

Close Interlock Mode 80# 0# (Factory Default)

Enable Interlock Mode 80# 1#

Red shines
Orange bright

Exit Program Mode

*

Red bright

Note: The Door Contact must be installed, or this function cannot be

enable.

Wiring diagram of Interlock

1n4004 1n4004 1n4004 1n4004

NO NC COM DC+ OPEN ALARMD0 D1 GND D_IN

Blue Orange Purple

Magnetic Lock or Fail-Safe Lock
+

K-
Fail-secure lock
K+

-
Fail-secure lock
+

K-
Magnetic Lock or Fail-Safe Lock
K+

Red Exit button
Yellow Grey
Green White
Black
Brown

Power Supply GND +12V

Door contact

Door contact

Passageway A

Gold

B

Warehouse

A Control

Blue Orange Purple
Red Exit button
Yellow Grey
Green White Black Brown

NO NC COM DC+ OPEN ALARMD0 D1 GND D_IN

B Control

14

FCC Caution:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC's RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.


Corel PDF Engine Version 14.0.0.701 CorelDRAW