User Manual for LightCloud models including: BLET8WT, 2AXDB-BLET8WT, 2AXDBBLET8WT, Linear T8 Tube Ballast Bypass, Linear T8, Tube Ballast Bypass
Shenzhen Qianhai Intellidata Technology Co., Ltd BLET8WT LED tube 2AXDB-BLET8WT 2AXDBBLET8WT blet8wt
Suzhou EICCOMM Technology CO., Ltd. BLET8WT 2AXD8-BLET8WT 2AXD8BLET8WT blet8wt
YNNYNNN H SBCMPHP Hello Lightcloud Blue is a Bluetooth mesh wireless lighting control system that allows you to control RAB's various compatible devices. With RAB's patent-pending Rapid Provisioning technology, devices can be quickly and easily commissioned for residential and large commercial applications using the Lightcloud Blue mobile app. Each device in a system can communicate with any other device, eliminating the need for a Gateway or Hub and maximizing the control system's reach. Product Features Direct Connect LED, No Gateway or Hub required Wire directly to Line Voltage, bypass the ballast Wireless control from your mobile device Tunable White 2700K-6500K Wireless remote control Create custom scenes Activity Mode Sensor compatible Schedules and automations SmartShiftTM automated circadian schedule Catalog Number: LCBT8-18-48P-8TW-SD-BYP-SS Model Number: LCBT8-18-48P-8TW-SD-BYP-SS Electrical: 18W, 2200lm 120-277Vac 50/60Hz Construction: Lamp Base: G13 Retrofit application includes these items: Installation Instructions, LED Lamps, Luminaire Marking Labels. Safety Information installation requires knowledge of luminaires electrical in luminaires that have the construction features and dimensions shown in the photographs and/or drawings exceed the input rating of the luminaire. · WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. lampholders. Note: Shunted lamp holders are found only "Instant Start" or "I.S." marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, contact the · Not suitable for use with dimmers and sensors unless · This device is not intended for use with emergency exits. Safety Information (cont'd) instructions to control this lamp. This lamp will not operate properly when connected to a standard (Incandescent) dimmer or dimming control. · Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. · Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors. where the suitability of the combination shall be determined by authorities having jurisdiction. Product with the applicable and appropriate electrical codes. The installation guide does not supersede local or national regulations for electrical installations. · Installers should examine all parts that are not intended to · Only dimmed by wireless control. Instructions, LED Lamps (Max. 4), Luminaire Marking Labels. Method 3: Rapid Reset Tool The rapid reset process must be done by professional electricians qualified by RAB. Reach out to your RAB sales manager to request a Rapid Reset Tool. The tool simply needs to be placed directly on the small Lightcloud Blue logo for 2 seconds. The lamp will flash 3 times, then reset to 100% brightness at default CCT. Functionality tcloud Blue products may be performed using the Lightcloud Blue app. Emergency default lamps on. WE'RE HERE TO HELP: 1 (844) LIGHTCLOUD 1 (844) 544-4825 support@lightcloud.com FCC Information: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Note: This device has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential environ ment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that inter ference will not occur in a particular installation. If th-is equipment does cause harmful interference to radio or television reception, or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Consult the dealer or an experienced radio/TV technician for help. To comply with the FCC's RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. to operate this equipment. 810x180mm C M Y 180° 10N/M K 3"# 80g ±1MM ±2% 1 2022-06-22macOS Version 12.5.1 (Build 21G83) Quartz PDFContext Adobe Illustrator 25.2 (Macintosh)