Owner's Manual for MEAN WELL models including: MSP-600-3.3, MSP-600-5, MSP-600-7.5, MSP-600-12, MSP-600-15, MSP-600-24, MSP-600-36, MSP-600-48, MSP-600 Series 600W Single Output Medical Type, MSP-600 Series, 600W Single Output Medical Type, Single Output Medical Type, Output Medical Type, Medical Type, Type
Блок живлення що вбудовується 600W 36V MSP-600-36 MeanWell за ціною від 8690.00 грн - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 4 Pages, 638.61KB
DocumentDocument600W Single Output Medical Type MSP-600 series https://www.meanwell.com/serviceGTIN.aspx User's Manual SPECIFICATION MODEL MSP-600-3.3 MSP-600-5 MSP-600-7.5 MSP-600-12 MSP-600-15 MSP-600-24 MSP-600-36 MSP-600-48 DC VOLTAGE RATED CURRENT 3.3V 5V 7.5V 12V 15V 24V 36V 48V 120A 120A 80A 53A 43A 27A 17.5A 13A CURRENT RANGE 0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A RATED POWER 396W 600W 600W 636W 645W 648W 630W 624W OUTPUT RIPPLE & NOISE (max.) Note.2 120mVp-p VOLTAGE ADJ. RANGE 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 ±2.0% LINE REGULATION ±0.5% LOAD REGULATION ±1.0% 150mVp-p 4.3 ~ 5.8V ±2.0% ±0.5% ±1.0% 150mVp-p 6.8 ~ 9V ±2.0% ±0.5% ±1.0% 150mVp-p 10.2 ~ 13.8V ±1.0% ±0.3% ±0.5% 150mVp-p 13.5 ~ 18V ±1.0% ±0.3% ±0.5% 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5% 200mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5% 240mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5% SETUP, RISE TIME HOLD UP TIME (Typ.) 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 120 ~ 370VDC POWER FACTOR (Typ.) PF>0.93/230VAC PF>0.99/115VAC at full load INPUT EFFICIENCY (Typ.) 78.5% 82% 86% 88% 88% 88% 89% 89% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 8.5A/115VAC 5A/230VAC 35A/115VAC 80A/230VAC Earth leakage current < 300A/264VAC , Touch leakage current < 100A/264VAC OVERLOAD 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE 3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V Protection type : Shut down o/p voltage, re-power on to recover 41.4 ~ 48.6V OVER TEMPERATURE 5V STANDBY Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.) DC OK SIGNAL FUNCTION REMOTE CONTROL FAN CONTROL (Typ.) WORKING TEMP. PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off Load 35±15% or RTH250 Fan on -40 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS IEC 60601-1:2005+A1+A2, ANSI/AAMI ES60601-1:2005+A2, CAN/CSA C22.2 No. 60601-1:2014+A2 EAC TP TC 004 approved; Design refer to BS EN/EN60335-1, BS EN/EN 62368-1(by request) SAFETY & EMC (Note 4) ISOLATION LEVEL WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION Primary-Secondary: 2×MOOP, Primary-Earth: 1×MOOP, Secondary-Earth: 1×MOOP I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55011 (CISPR11) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 57.6 ~ 67.2V EMC IMMUNITY MTBF Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN60601-1-2, EAC TP TC 020 138.7K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 218*105*63.5mm (L*W*H) PACKING 1.57Kg;8pcs/13.6Kg/1.34CUFT NOTE FF (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) Downloaded from Arrow.com.https://www.meanwell.com/serviceDisclaimer.aspx File Name:MSP-600-SPEC 2024-10-30 600W Single Output Medical Type Mechanical Specification (Unit: mm , tolerance ± 1mm) 152.4 20.75 10 8.2 Air flow direction I/P 1 2 3 12max. 63.5 4-M4 L=6 218 152.4 8-M4 L=4 (Both Sides) MSP-600 series 32.8 O/P 1 2 3 4 5 6 32.8 18max. 9.2 11 Case No. 977A 19 2 10 105 12.5 38.3 63.5 CN100 LED (Vo ADJ.)SVR1 AC Input Terminal Pin No. Assignment Pin No. Assignment 1 AC/L 2 AC/N 3 FG Block Diagram I/P EMI FILTER FG Derating Curve DC Output Terminal Pin No. Assignment Pin No. Assignment 1~3 -V 4~6 +V ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC O.T.P. PFC CONTROL Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent Pin No. Assignment Pin No. Assignment Mating Housing Terminal 1 AUXG 6,8 GND 2 AUX 7 DC-OK 3 RC+ 9 +S HRS DF11-10DS HRS DF11-**SC or equivalent or equivalent 4 RC- 10 -S 5 CS AUX POWER POWER SWITCHING RECTIFIERS & FILTER RECTIFIERS & FILTER O.L.P. PWM CONTROL DETECTION CIRCUIT O.T.P. O.V.P. REMOTE CONTROL Output Derating VS Input Voltage PWM fosc : 70KHz AUX AUXG +S +V -V -S DC OK CURRENT SHARING CS RC+ RC- LOAD (%) LOAD(%) 125 100 100 90 80 80 70 50 60 50 20 40 -40 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:MSP-600-SPEC 2024-10-30 Downloaded from Arrow.com. 600W Single Output Medical Type MSP-600 series Function Description of CN100 Pin No. Function Description 1 AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). 2 AUX Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The maximum load current is 0.3A. This output is not controlled by the "remote ON/OFF control". 3 RC+ Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON. 4 RC- Remote control ground. 5 CS Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units. 6,8 GND This pin connects to the negative terminal(-V). Return for DC-OK signal output. 7 DC-OK DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND). High when PSU turns on. 9 +S Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 10 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Function Manual 1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. CN100 21 10 9 CN100 2 AUX AUXG 1 RC- RC+ GND CS GND DC-OK 10 -S 9 +S +S (Pin9) +LOAD -S (Pin10) 2.DC-OK Signal DC-OK signal is a TTL level signal. High when PSU turns on. Between DC-OK(pin7) and GND(pin6,8) Output Status 3.3 ~ 5.6V ON 0 ~ 1V OFF CN100 21 10 9 Fig 1.1 Sense lines should be twisted in pairs CN100 2 AUX AUXG 1 RC- RC+ GND CS GND DC-OK 10 -S +S 9 Fig 2.1 Downloaded from Arrow.com. File Name:MSP-600-SPEC 2024-10-30 600W Single Output Medical Type MSP-600 series 3.Remote Control The PSU can be turned ON/OFF by using the "Remote Control" function. Between RC+(pin3) and RC-(pin4) Output Status SW ON (Short) OFF SW OFF (Open) ON CN100 21 10 9 CN100 2 AUX AUXG 1 RC- RC+ GND CS GND DC-OK 10 -S +S 9 SW Fig 3.1 4.Current Sharing with Remote Sensing (Only for 24V, 36V and 48V) MSP-600 has the built-in active current sharing function and can be connected in parallel to provide higher output power : (1)Parallel operation is available by connecting the units shown as below. (+S,-S,CS and GND are connected mutually in parallel). (2)Difference of output voltages among parallel units should be less than 2%. (3)The total output current must not exceed the value determined by the following equation. (output current at parallel operation)=(Rated current per unit)×(Number of unit)×0.9 (4)In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel. (5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load. PSU1 PSU2 PSU3 PSU4 CN100 -V +V CN100 -V +V CN100 -V +V CN100 -V +V PSU1 CN100 1 AUXG RC+ CS DC-OK +S 9 2 AUX RC- GND GND -S 10 PSU2 CN100 1 AUXG RC+ CS DC-OK +S 9 2 AUX RC- GND GND -S 10 PSU3 CN100 1 AUXG RC+ CS DC-OK +S 9 2 AUX RC- GND GND -S 10 PSU4 CN100 1 AUXG RC+ CS DC-OK +S 9 2 AUX RC- GND GND -S 10 +V -V LOAD Sense lines should be twisted in pairs Fig 4.1 Note : 1.In parallel connection, maybe only one unit (master) operate if the total output load is less than 2% of rated load condition. The other PSU (slave) may go into standby mode and its output LED and relay will not turn on. 2.2% min. of dummy load is required. File Name:MSP-600-SPEC 2024-10-30 Downloaded from Arrow.com.