THE RIGHT CHOICE We thank you for your purchase. Our products are 100% tested but should you have any questions, please contact us by phone or on our web site.
ST-2459
WARNING: Vitreous china can chip or break if the bolts or nuts are over-tightened or if mishandled.
· Check all local plumbing and building codes. · Check for any damage to the new water closet
before installation.
WHAT YOU WILL NEED... · Sponge
· Putty knife · Safety glasses · Measuring tape · Spud wrench
· 10" adjustable wrench · Large level · Carrier Mounting
hardware
· Non-wax Gasket
NOTE: Plumbing System Requirements Minimum Flowing Pressure: 25 PSI Minimum Flow Rate: 18 GPM Maximum Static Pressure: 80 PSI
NOTE: All vitreous china dimensions shown in these drawings are nominal. Dimensions can vary within the tolerances established in the governing ASME A112.19.2/CSA B45.1 standard. Please take this into consideration when planning rough-in and plumbing layouts.
RETROFIT INSTALLATIONS
1. REMOVAL OF EXISTING WATER CLOSET
· Turn off the water supply. · Disconnect the flush valve. · Sponge out all remaining water from bowl. · Cut caulk all around existing bowl using utility knife
to release bowl from wall surface. · Remove the existing water closet. · Using sharp scraper or putty knife, completely
remove all remaining caulk from wall surface. · Dispose of old gasket.
2. CHECK ROUGH-IN DIMENSIONS
· Check rough-in dimensions and install or relocate flush valve and outlet as indicated.
· A carrier unit is recommended to properly install and support the wall hung water closet. Install carrier unit (not included) per instructions provided by the carrier manufacturer.
· Verify carrier studs are level.
3. CLEAN DRAIN
· Clean out waste pipe using hand or power cleaner to be sure pipe is clear.
· Proceed to NEW INSTALLATIONS.
1-1/2" (38 mm) Spud
WARNING: Hazardous gases can escape through the waste pipe if new water closet is not installed quickly. A temporary fix: place a large rag in the waste pipe.
5.5" (140 mm)
NEW INSTALLATIONS 1. INSTALLING GASKET · Remove the temporary rag (if used) from the waste
pipe hole. · Lay water closet down on padded surface to help
protect the vitreous china. · Apply gasket to bowl outlet. Refer to the gasket
manufacturer's instructions for installation. (Note: wax gaskets of any kind are NOT recommended.)
Non-wax Gasket
2. INSTALLING WATER CLOSET
Finished Wall Bearing Nuts and Washers
Distance of washer from wall approx. 1/16"
Front Nut
Washer
· Loosely attach washers and front nuts on threaded carrier studs.
· Verify water closet is level. · Hand tighten the (3) nuts that have the bearing nuts
behind the water closet. · Tighten the top nut then bottom nuts alternately
while judging the flex of the bowl at the front lip due to the compression of the gasket. Bowl is secure and has adequate seal when no noticeable flex occurs. · Hand-tighten the last nut and washer, then tighten 1/4-turn using a wrench.
IMPORTANT! Do not overtighten the nuts, breakage and chipping of vitreous china can occur.
LIMITED WARRANTY
Sloan Valve Company warrants its vitreous china products to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer's cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company's products directly from Sloan Valve Company for purpose of resale.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER. NOTE: IN NO EVENT SHALL THE SLOAN VALVE COMPANY BE LIABLE FOR INCIDENTAL DAMAGES, RESULTING FROM IMPROPER INSTALLATION, OR FOR DAMAGES CAUSED BY NEGLECT, ABUSE OR ALTERATION.
TO MAXIMIZE THE PERFORMANCE OF YOUR SLOAN® WATER CLOSET, USE ONLY SLOAN® FLUSHOMETERS
26-3/4" (680 mm) 2-3/4" (70 mm)
1.65" (42 mm)
13 1/4" (336 mm)
15" (381 mm)
1/2" (13 mm)
15" (381 mm)
7.5" 16"-18" (406-457 mm) (190 mm)
9" (230 mm)
3-3/8" (86 mm)
5 1/8" (130 mm) 6 1/8"-8 1/8"(155-206 mm)
Carrier Adjustable Studs Coupling
· Determine proper length for carrier studs per carrier's manufacturer.
· Install (3) sets of bearing nuts and washers onto carrier studs: two at the bottom and one on top leaving one top stud blank.
· Bearing nuts and washers must be placed to allow a minimum gap of 1/16" between the wall and fixture. The carrier supports the bowl, not the wall.
· Place level vertically across the top and bottom bearing nuts to ensure they are leveled.
· Adjust carrier coupling to compress gasket for a gas and watertight seal per gasket manufacturer's instructions.
3. COMPLETING THE INSTALLATION
· Flush valve should be installed to manufacturer's installation instructions.
· Place water closet unto the carrier studs.
· Turn on water supply valve. · Install water closet seat. · Caulk around water closet. · Flush water closet a few times and check all
connections for water seepage. · Check for leaks for a few days. · Record model number for reference.
The information contained in this document is subject to change without notice.
SLOAN VALVE COMPANY
10500 Seymour Avenue Franklin Park, IL 60131 Phone: 1-800-9-VALVE-9 or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com
Copyright © 2015 Sloan Valve Company
Code: 0816652
Rev. 1 09-15
Instalación Instrucciones de Sanitario Modelo Serie ST-2459
LA ELECCIÓN CORRECTA Le agradecemos su compra. Nuestros productos son probados al 100%, sin embargo, si tiene alguna duda, contáctenos por teléfono o en nuestro sitio web.
ST-2459
ADVERTENCIA: Cualquier porcelana puede astillarse o romperse si los pernos o tuercas se aprietan de más o si son mal manipulados. · Revise todos los códigos locales de plomería y
construcción. · Revise si el nuevo sanitario presenta daños antes
de instalarlo.
LO QUE USTED NECESITA...
· Espátula para masilla
· Lentes de Seguridad · Esponja
· Cinta para medir
· Llave ajustable 10"
· Llave para spud
· Nivel grande
· Empaque sin cera
· Cargador y Herrajes
de montaje
NOTA: Requerimientos del Sistema de Plomería
Presión Mínima de Flujo: 25 PSI
Caudal Mínimo: 18 GPM
Máxima presión estática: 80 PSI
NOTA: Todas las dimensiones mostradas en estos dibujos son nominales. Las dimensiones pueden variar dentro de las tolerancias establecidas en la norma ASME A112.19.2/CSA B45.1. Por favor tenga esto en cuenta al planificar la preparación y diseños de plomería.
1-1/2" (38 mm) Spud 5.5" (140 mm)
INSTALACIONES DE REEQUIPAMIENTO 1. REMOVER EL SANITARIO EXISTENTE · Cierre la alimentación de agua. · Desconecte la válvula de descarga. · Seque toda el agua remanente en la taza. · Corte la masilla con el cuchillo multiusos por todo
alrededor de la taza existente para soltarla de la superficie. · Remueva el sanitario existente. · Usando un raspador afilado o una espátula, remueva completamente la masilla restante de la superficie de la pared. · Elimine el empaque usado.
2. REVISAR LAS DIMENSIONES DE PREPARACIÓN · Revise las dimensiones de preparación e instale
o mueva la válvula de descarga y salida como se indica · Se recomienda una unidad portadora para instalar adecuadamente y soportar el sanitario colgado de pared. Instale la unidad portadora (no incuido) de acuerdo con las instrucciones del fabricante de la misma. · Verifique que los pernos del portador estén nivelados.
3. LIMPIAR EL DESAGÜE · Limpie el tubo de drenaje con un limpiador manual
o eléctrico para asegurarse que quede bien limpio. · Proceda a INSTALACIONES NUEVAS.
ADVERTENCIA: Gases peligrosos pueden escapar por la tubería de desagüe si el nuevo sanitario no se instala rápidamente. Una solución temporal: coloque un trozo grande de tela en la tubería de desagüe. INSTALACIONES NUEVAS
INSTALACIONES NUEVAS 1. INSTALAR EL EMPAQUE · Remueva el trozo de tela temporal (si se utilizó) del
agujero del tubo de drenaje. · Coloque el sanitario sobre una superficie acolchada
para proteger la porcelana. · Coloque el empaque a la salida de la taza. Consulte
su instalación en las instrucciones del fabricante del empaque. (Nota: NO se recomiendan los empaques de cualquier tipo que son totalmente de cera).
Empaque sin cera
2. INSTALAR EL SANITARIO
parad terminada
de soporte tuercas y arandelas
distancia de la arandela a la pared 1/16" aprox.
Frente Tuerca
Arandela · Coloque flojas las arandelas y tapones roscados
en los pernos roscados del portador. · Verifique que el sanitario esté nivelado. · Apriete firmemente los (3) tapones roscados
y arandelas en los pernos que contienen las tuercas y arandelas de soporte. Luego instale la última arandela y tapón roscado apretando aproximadamente 1/4 de vuelta.
¡IMPORTANTE!: No apriete de más las tuercas, puede ocurrir ruptura o astillarse la porcelana.
GARANTÍA LIMITADA Sloan Valve Company garantiza que sus productos de porcelana están hechos de materiales de primera clase, libres de defectos en el material o en la fabricación, bajo uso normal y para llevar a cabo el servicio para el cual se han fabricado, en una forma totalmente eficiente y confiable siempre que se instalen adecuadamente y se les dé el servicio adecuado, por un período de tres años a partir de la fecha de compra. Durante este periodo Sloan, a su discreción, reparará o reemplazará cualquier parte o partes que se comprueben que estén defectuosas si se devuelven a Sloan, a costo del cliente, y este será el único recurso correctivo que se ofrece con esta garantía. No se aceptarán reclamos por mano de obra, transporte ú otros costos incidentales. La presente garantía se extiende únicamente a personas u organizaciones que compren los productos de Sloan Valve Company directamente de Sloan Valve Company con fines de reventa. NO EXISTEN MÁS GARANTÍAS QUE SE EXTIENDAN MAS ALLÁ DE LA QUE SE DESCRIBIÓ ANTERIORMENTE. EN NINGÚN CASO SLOAN VALVE COMPANY ES RESPONSABLE POR CUALQUIER DAÑO CONSECUENTE DE CUALQUIER CLASE. NOTA: EN NINGÚN CASO SLOAN VALVE COMPANY SERÁ RESPONSABLE POR DA--OS INCIDENTALES, RESULTADO DE INSTALACIÓN INADECUADA, O POR DA--OS CAUSADOS POR NEGLIGENCIA, ABUSO O ALTERACIÓN.
PARA MAXIMIZAR EL DESEMPEÑO DE SU SANITARIO SLOAN®, USE ÚNICAMENTE FLUXÓMETROS SLOAN®
26-3/4" (680 mm) 2-3/4" (70 mm)
1.65" (42 mm)
13 1/4" (336 mm)
15" (381 mm)
1/2" (13 mm)
15" (381 mm)
7.5" 16"-18" (406-457 mm) (190 mm)
9" (230 mm)
3-3/8" (86 mm)
5 1/8" (130 mm) 6 1/8"-8 1/8"(155-206 mm)
pernos acoplamiento
ajustable
· Determine la longitud necesaria de los pernos de acuerdo a las instrucciones del fabricante del portador.
· Instale (3) juegos de tuercas y arandelas de soporte en los pernos del portador: dos en la parte inferior y en uno de los pernos superiores dejando el otro sin tuerca ni arandela.
· Las tuercas y arandelas de soporte deben ser instaladas garantizando un espacio mínimo de 1.6 mm (1/16") entre el sanitario y la pared. El portador es el que debe soportar el sanitario, no la pared.
· Coloque un nivel sobre las dos tuercas de soporte inferiores y luego sobre la tuerca de soporte superior asegurando que están niveladas.
· Ajuste el acomplamiento del portador para asegurar la adecuada compresión en el empaque para garantizar un buen sello.
3. TERMINAR LA INSTALACIÓN · La válvula de descarga debe instalarse de acuerdo
con las instrucciones de su fabricante.
· Abra la válvula de alimentación de agua. · Instale el asiento del sanitario. · Coloque masilla alrededor del sanitario. · Descargue el sanitario varias veces y revise todas
las conexiones para ver si presentan filtraciones. · Revise si hay fugas por varios días. · Registre el número de modelo como referencia.
SLOAN VALVE COMPANY
10500 Seymour Avenue Franklin Park, IL 60131 Tel: 1-800-9-VALVE-9 o 1-847-671-4300 Fax: 1-800-447-8329 o 1-847-671-4380 www.sloanvalve.com
· Coloque el sanitario en los pernos del portador.
La información contenida en este documento está sujeta a cambios sin previo aviso.
Copyright © 2015 Sloan Valve Company No. Codigo: 0816652 Rev.1 09-15
INSTALLATION INSTRUCTIONS FOR EXPOSED REGAL® XL WATER CLOSET AND URINAL FLUSHOMETERS
Code No. 0816312 Rev. 3 (08/23)
Closet Flushometer 1½" (38 mm) Top Spud MODELS 110/111, 113, 115 & 116
Closet Flushometer 1½" (38 mm) Back Spud MODEL 120 & 122
Service Sink Flushometer 1½" (38 mm) Top Spud MODEL 117
Urinal Flushometer 1¼" (32 mm) Top Spud MODEL 180
Urinal Flushometer ¾" (19 mm) Top Spud MODEL 186
Squat Toilet Flushometer 1½" (38 mm) Back Spud MODEL 137
SLOAN® LIMITED WARRANTY SUMMARY
Sloan Valve Company ("Sloan"), warrants its products against defects in materials and workmanship, excluding damage caused by matters beyond Sloan's reasonable control. Instructions for filing claims can be found in the Limited Warranty which can be obtained at www.sloan.com or by requesting a free copy by telephone at 888.756.2614. Sloan will repair or replace your defective product, or provide a refund, as your exclusive remedy. This is only a general summary of Sloan's Limited Warranty so it is important to note that the specific terms, conditions, limitations and exclusions, including the duration of warranty coverage for your particular Sloan product, are contained in the actual Sloan Limited Warranty. The Limited Warranty is subject to applicable laws in your country, state, province or other jurisdiction--and disputes arising under the Limited Warranty are to be resolved by binding arbitration unless you provide Sloan with an opt-out notice no later than 30 days after your purchase date. In case of a conflict with this summary, the terms and conditions set forth in the complete Limited Warranty will prevail.
PRIOR TO INSTALLATION
Before you install the Regal XL flushometer, be sure the items listed below are installed. Also, refer to the rough-in diagrams in the next section. · Closet or urinal fixture · Drain line · Water supply line
IMPORTANT: · INSTALL ALL PLUMBING IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS. · WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN
ADEQUATE VOLUME OF WATER FOR EACH FIXTURE. · FLUSH ALL WATER LINES PRIOR TO MAKING
CONNECTIONS.
Sloan's flushometers are designed to operate with 15 Psi (103 kPa) flowing water pressure to 80 Psi (551 kPa) static water pressure. Static water pressure above 80 Psi (550 kPa) is deemed unsafe and must be reduced. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for minimum pressure requirements. Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum flowing pressure of 25 psi (172 kPa).
TOOLS REQUIRED FOR INSTALLATION · Straight blade screwdriver · Sloan A-50 Super-WrenchTM, Sloan A-109 Plier Wrench or smooth jawed spud
wrench
VALVE ROUGH-INS
MODELS 110/111
MODELS 113, 115 & 116
MODELS 120/122
MODEL 117
NOTE: Water Closet Valves with "-2.4" Model Designation deliver 2.4 gpf (9.0 Lpf).
MODEL 180
MODEL 186
NOTE: Model 180 requires 1" I.P.S. (DN 25 mm) Supply.
IMPORTANT NOTES: · When mounted on an
ADA accessible bowl, the rough-in to the supply inlet should be no higher than 37½" or the handle will exceed maximum height allowances under ADA guidelines. · New ADAAG Guidelines allow for Split or Offset Grab Bars, check with local authorities or reference section 604.5.2 of ADAAG.
1" Control Stop is available with Whitworth Thread.
PRIOR TO INSTALLATION
!!! IMPORTANT !!! WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE
COMPONENT OR COUPLING!
!!! IMPORTANT !!!
PROTECT THE FINISH OF SLOAN'S FLUSHOMETERS -- DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THESE
VALVES. USE A SLOAN A-50 Super-WrenchTM, Sloan A-109 PLIER WRENCH OR SMOOTH JAWED SPUD WRENCH TO SECURE ALL COUPLINGS. SEE "CARE AND CLEANING"
SECTION.
!!! IMPORTANT !!!
THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL COMPONENTS THAT ARE SUBJECT TO NORMAL WEAR. THESE COMPONENTS SHOULD BE CHECKED ON A REGULAR BASIS AND REPLACED AS NEEDED TO MAINTAIN THE VALVE'S PERFORMANCE.
!!! IMPORTANT !!! NEVER OPEN CONTROL STOP TO WHERE THE FLOW FROM
THE VALVE EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN THE EVENT OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO ACCOMMODATE A CONTINUOUS FLOW
FROM THE VALVE.
!!! IMPORTANT !!! LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER
FLUSHING VOLUMES THAN LISTED ON FIXTURE OR FLUSHOMETER.
Please take the time to read this manual to ensure proper product installation and longevity. Also, please visit our website to download our most recent documentation for this product.
If you have questions about how to install your Flushometer, consult your local Sloan Representative or call Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614)
1 - INSTALL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)
A Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼" (32
mm) shorter than this measurement. Chamfer O.D. and I.D. of water
supply pipe.
FINISHED WALL
WATER SUPPLY PIPE
1-1/4" (32 mm)
B Slide Threaded Adapter fully onto pipe. C Sweat solder the Adapter to pipe.
SWEAT SOLDER ADAPTER
C/L OF FIXTURE SPUD
2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE AND INSTALL VACUUM BREAKER FLUSH CONNECTION
A Measure from finished wall
to first thread of adapter
or threaded supply pipe
(dimension "X"). Cut cover
tube to this length.
WATER SUPPLY PIPE
X
B Slide cover tube over pipe.
Slide wall flange over cover
tube until against wall.
SWEAT SOLDER ADAPTER
COVER TUBE
C Thread Control Stop onto
pipe. Tighten with a wrench making sure outlet is positioned as required.
SUPPLY FLANGE
SETSCREW
COVER TUBE AND CAST SUPPLY FLANGE WITH SETSCREW ARE AVAILABLE IN "YBYC" SWEAT SOLDER KIT.
H-700 SER
WALL FLANGE
SETSCREW
IRON PIPE NIPPLE OR COPPER PIPE WITH SWEAT SOLDER ADAPTER
COVER TUBE
BAK-CHEK® CONTROL STOP
IES STOP
PLUG
D Tighten setscrew with a 1/16" hex wrench. DO NOT install vandal
resistant plug at this time.
E Slide spud coupling, nylon slip gasket, rubber gasket and spud flange
over vacuum breaker tube.
MODELS 110/111, 113, 115, 116 & 117
MODELS 120 & 122
VACUUM BREAKER
TUBE
VACUUM BREAKER
MODEL 180
MODEL 186
VACUUM BREAKER
TUBE
ELBOW FLUSH CONNECTION
SPUD COUPLING
SPUD COUPLING SPUD FLANGE
SPUD COUPLING
NYLON SLIP GASKET
RUBBER GASKET
SPUD FLANGE
NYLON SLIP GASKET
RUBBER GASKET
NYLON SLIP GASKET
RUBBER GASKET
SPUD FLANGE
F Insert Tube into Fixture Spud.
G Hand tighten Spud Coupling onto Fixture Spud.
2
3 - INSTALL FLUSHOMETER AND HANDLE ASSEMBLY
NOTE For high efficiency urinal flushometers (0.5, 0.25 and 0.125 gpf), it is necessary to first insert the flow control component into the tailpiece assembly. See the H1015A flow control kit and separate
instructions for details on how to install.
A Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece
into Control Stop. Tighten Tailpiece Coupling by hand.
B Align Flushometer directly above the
Vacuum Breaker Flush Connection by sliding the Flushometer Body IN or OUT as needed. Tighten Vacuum Breaker Coupling by hand.
NOTE Maximum adjustment of the Sloan Adjustable Tailpiece is 1/2" (13 mm) IN or OUT from the standard 4-3/4" (121 mm) (centerline of Flushometer to centerline of Control Stop). If roughing-in measurement exceeds 5-1/4" (133 mm), consult
factory for longer tailpiece.
C Align Flushometer Body. Using a wrench, securely tighten couplings
in the order given: (1) Tailpiece Coupling, (2) Vacuum Breaker Coupling and (3) Spud Coupling.
D Install the red A-31 Handle Gasket on the Handle Assembly. Insert
the ADA Handle Assembly (B-73-A) into the Handle opening in the
Flushometer Body. Securely tighten the Handle coupling with a wrench.
FLUSHOMETER BODY
A-31 GASKET
HANDLE COUPLING
HANDLE ASSEMBLY
VACUUM BREAKER COUPLING
2
VACUUM BREAKER
FLUSH CONNECTION
TAILPIECE COUPLING
1
CONTROL STOP
C/L SUPPLY
G-44 FRICTION
RING
VACUUM
O-RING
BREAKER
REPAIR KIT ADJUSTABLE
TAILPIECE 4-3/4"
(121 mm)
±1/2"
(13 mm)
SPUD COUPLING
3
C/L FIXTURE
4 - FLUSH OUT SUPPLY LINE
A Make sure Control Stop is CLOSED and
remove Flushometer Outer Cover.
B Remove Inside Cover and lift out Inside
Parts Assembly.
C Reinstall Outside and Inside Cover
wrench tight. Open Control Stop to flush supply line. Close Control Stop and remove Outside and Inside Cover.
D Reinstall Inside Parts Assembly, Inside
Cover and Outside Cover wrench tight.
5 - ADJUST CONTROL STOP AND INSTALL PLUG
A Open control stop COUNTERCLOCKWISE one FULL turn from closed position.
B Activate flushometer.
C Adjust control stop after
each flush until the rate of flow delivered properly cleanses the fixture.
!!! IMPORTANT !!!
Sloan's flushometers are engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy
the needs of the fixture. Proper adjustment is made when the plumbing fixture is cleansed after each flush without splashing water
out from the lip AND a quiet flushing cycle is achieved.
Never open Control Stop to where the flow from the valve exceeds the flow capability of the fixture. In the event of a valve failure, the fixture
must be able to accommodate a continuous flow from the valve.
D Install plug into the control
stop by pressing into bonnet.
BAK CHEK® CONTROL STOP
BONNET
IES STOP
PLUG
H-700 SER
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean Flushometers that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the Flushometer from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating.
3
TROUBLESHOOTING
I. Flushometer does not function (no flush). A. Control stop or main valve is closed. Open control stop or main valve. B. Handle assembly is damaged. Replace handle (B-32-A or B-73-A) or install handle repair kit (B-50-A). C. Relief valve is damaged. Replace inside parts kit. D. Static water pressure above 80 Psi (551 kPa). Reduce static water pressure.
2. Volume of water is not sufficient to siphon fixture. A. Control stop is not open wide enough. Adjust control stop for desired delivery of water volume. B. Urinal flushometer parts inside a closet flushometer. Replace inside urinal parts with proper closet flushometer parts. C. Low consumption flushometer installed on a non-low consumption fixture. Replace A-41-A inside parts kit with A-38-A water saver kit. D. Water saver kit installed in old, non-water saver bowl. Position refill head A-170 so that SIDE 1 is in the UP position. E. Inadequate volume or pressure at supply. · If no gauges are available to properly measure supply pressure or volume of water at the flushometer, then remove the relief valve from the inside parts kit, reassemble the flushometer and open the control stop. If the fixture siphons, more water volume is required. If a 3.5 gpf inside parts kit is installed in the flushometer, then first flip the refill head (under the diaphragm) to obtain a 4.5 gpf volume. If this volume is still inadequate, remove the flow ring from the guide to obtain a 6.5 gpf kit. If additional flow is still required, try a low pressure guide kit A-175-A (#0301104). IMPORTANT -- LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON FIXTURE OR FLUSHOMETER. · If fixture does not siphon or if a low consumption fixture is installed, or if the above steps do not prove satisfactory, steps must be taken to increase the pressure and/or supply.
3. Flushometer closes off immediately. A. Damaged diaphragm. Replace inside parts kit to correct problem. B. Enlarged by-pass orifice from corrosion or damage. Install inside parts kit to correct problem and update flushometer.
4. Length of flush is too short (short flush). A. Diaphragm assembly and guide assembly are not hand-tight. Screw the two assemblies hand-tight. B. Enlarged by-pass orifice from corrosion or damage. Install NEW Inside parts kit to correct problem and update flushometer. C. A-19-AU (Black) urinal relief valve in closet flushometer. Replace relief valve with A-19-AC (White) closet relief valve. D. A-41-A low consumption kit installed in non-low consumption fixture. Replace with proper Inside Parts Kit. E. Handle assembly is damaged. Replace handle (B-32-A or B-73-A) or install handle repair kit (B-50-A).
5. Length of flush is too long (long flush) or fails to close off. A. Relief valve (A-19-A) is not seating properly or by-pass orifice is clogged because of foreign material, or by-pass orifice is closed by an invisible gelatinous film from "over-treated" water. Disassemble the working parts and wash thoroughly. NOTE: SIZE OF THE ORIFICE IN THE BY-PASS IS OF UTMOST IMPORTANCE FOR THE PROPER METERING OF WATER INTO THE UPPER CHAMBER OF THE FLUSHOMETER. DO NOT ENLARGE OR DAMAGE THIS ORIFICE. REPLACE INSIDE KIT IF CLEANING DOES NOT CORRECT PROBLEM. B. Line pressure has dropped and is not sufficient to force Relief Valve to seat. Shut off all control stops until pressure has been restored, then open them again. C. A-19-AC (White) closet Relief Valve has been used in a 1 or 1½ gpf Urinal. Replace with A-19-AU (Black) Relief Valve. D. Inside cover is cracked or damaged. Replace the Inside Cover (A-71).
6. Chattering noise is heard during flush. A. Inside Cover is damaged. Replace Inside Cover (A-71). B. A-156-A Segment diaphragm has been installed upside-down. Reposition the Segment diaphragm properly (see markings on the Diaphragm).
7. Handle Leaks. A. B-39 Handle Seal is worn or damaged. Install new B-39 Seal. NOTE: The B-39 Seal will easily slide onto the B-40 Bushing when wet. B. Handle gasket has been omitted. Install Handle gasket (A-31) or Sloan handle repair kit (B-50-A). C. Valve handle bushing is worn. Replace handle repair kit (B-50-A).
PARTS LIST
7 1 2B 2A
8
3A
IES STOP
3B
H-700 SER
4A
4D
5
6A
4B
4C
6A
6B
6C
Item No.
Part No.
Description
1
Valve Assembly
2A B-73-A ADA Compliant Handle Assembly
2B A-31
Handle Gasket
3A H-790-A Bak-Chek® Control Stop
3B H-528 Control Stop Bonnet Plug
4A V-500-AA 1½" (38 mm) x 9" (229 mm) Vacuum Breaker Assembly
4B V-500-AA 1¼" (32 mm) x 9" (229 mm) Vacuum Breaker Assembly
4C V-500-AA ¾" (19 mm) x 9" (229 mm) Vacuum Breaker Assembly
4D V-500-A Vacuum Breaker Assembly
5 F-109
1½" (38 mm) Elbow Flush Connection
6A F-56-A 1½" (38 mm) Spud Coupling Assembly
6B F-57-A 1¼" (32 mm) Spud Coupling Assembly
6C F-58-A ¾" (19 mm) Spud Coupling Assembly
7 F-7
Supply Flange (Supplied when Valve is Not Ordered with
Sweat Solder Kit)
8 H-633-AA 1" (25 mm) Sweat Solder Kit and Cast Wall Flange
with Setscrew
H-636-AA ¾" (19 mm) Sweat Solder Kit and Cast Wall Flange
with Setscrew
Part number varies with valve model variation; consult factory Length varies with valve model variation; consult factory
When assistance is required, please contact Sloan Technical Support: 1-888-SLOAN-14 (1-888-756-2614)
The information contained in this document is subject to change without notice.
SLOAN · 10500 SEYMOUR AVENUE · FRANKLIN PARK, IL 60131
Phone: 1-800-982-5839 or 1-847-671-4300 · Fax: 1-800-447-8329 or 1-847-671-4380 · www.sloan.com
© 2023 SLOAN VALVE COMPANY
Code No: 0816312 Rev. 3 (08/23)