Portable Air Conditioner User Manual

Models: ZCP08SA, ZCP10SA, ZCP12SA

Important Safeguards

Read this user manual carefully before using the appliance. Keep it for future reference.

Disconnect the appliance from its power source during service, when replacing parts, and during cleaning.

The appliance shall not be installed in a laundry area.

Check the nameplate for the type of refrigerant gas used. The appliance contains fluoridated greenhouse gases covered by the Kyoto Protocol. Global Warming Potential (GWP) values are provided: R410A: 2088, R134a: 1430, R290: 3, R32: 675.

Do not pierce or burn the cooling circuit.

At the end of its useful life, deliver the appliance to a special waste collection center for disposal.

Do not use this unit for functions other than those described in this manual.

Ensure the plug is firmly and completely inserted into the outlet to avoid electric shock or fire risk.

Do not plug other appliances into the same outlet.

Do not disassemble or modify the appliance or power cord. Refer all other services to a qualified technician.

Keep the power cord away from heaters, radiators, or other heat sources.

This unit is equipped with a cord with an earthed wire. Plug into a properly installed and earthed socket. Never cut or remove the earth pin.

Use or store the unit protected from moisture (e.g., condensation, splashed water). Unplug immediately if moisture occurs.

Always transport the appliance in a vertical position and place on a stable, level surface during use. If transported on its side, stand it up and leave unplugged for 6 hours.

Always use the control panel or remote control to turn the unit off. Do not start or stop operation by plugging/unplugging the power cord.

Do not touch control panel buttons with wet fingers.

Do not use hazardous chemicals for cleaning. Use only a soft cloth. Do not use wax, thinner, or strong detergents.

Do not use the unit in the presence of flammable substances or vapors (e.g., alcohol, insecticides, gasoline).

If the appliance makes unusual sounds or emits smoke/odor, unplug it immediately.

Do not clean the unit with water, as it can damage insulation and create a shock hazard. If water enters, unplug and contact Customer Service.

Utilize two or more people to lift and install the unit.

Always grasp the plug when plugging/unplugging; never pull the cord.

Install on a sturdy, level floor capable of supporting up to 110 lbs (50 kg).

If the appliance has Wi-Fi, transmission power is < 20 dBm, frequency range is 2412 MHz-2472 MHz. The appliance complies with RE Directive (2014/53/EU).

This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience, unless supervised or instructed by a responsible person.

Minimum Installation Clearance: 45 cm around and 45 cm above the unit.

Children should be supervised to ensure they do not play with the appliance.

If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.

Installation must comply with national wiring regulations.

For appliances with flammable refrigerants (R32):

[Fire Hazard] Do not attempt to accelerate defrosting or cleaning other than as recommended by the manufacturer.

[Fire Hazard] Store in a room without continuously operating ignition sources (open flames, operating gas or electric heaters).

[Fire Hazard] Do not pierce or burn.

Refrigerants may be odorless.

The above warnings are accompanied by a risk of fire symbol [Fire Hazard Symbol].

French Version:

AVERTISSEMENT

Ne pas utiliser de produits permettant d'accélérer le dégel ou de produits de nettoyage autres que ceux recommandés par le fabricant.

L'appareil doit être entreposé dans un endroit sans source d'allumage fonctionnant en continu (par exemple : flamme nue, appareil au gaz en marche ou radiateur électrique en marche).

Ne pas percer ni brûler.

Attention : les frigorigènes peuvent être inodores.

Additional information for units with flammable refrigerant (R32):

  • Maximum refrigerant charge amount (refer to nameplate).
  • Information for handling, installation, cleaning, servicing, and disposal of refrigerant.
  • Keep ventilation openings clear of obstruction.
  • Servicing shall be performed only as recommended by the manufacturer.
  • Store in a well-ventilated area corresponding to the room area specified for operation.
  • Store in a room without continuously operating open flames or ignition sources.
  • Prevent mechanical damage during storage.
  • Specific qualifications required for personnel performing maintenance, service, and repair.

FCC and IC Warnings

CAUTION: RISK OF FIRE

CAN ICES-3 (B)/NMB-3(B)

Contains FCC ID: 2ANDL-TYWE1S

Contains IC ID: 23243-TYWE1S

FCC Caution: This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If interference occurs, try correcting it by reorienting/relocating the antenna, increasing separation between equipment and receiver, connecting to a different circuit, or consulting a dealer/technician.

The distance between user and device should be no less than 20cm.

IC Warning: This device complies with Industry Canada's license-exempt RSSs. Operation is subject to two conditions: (1) this device may not cause interference; and (2) this device must accept any interference, including interference that may cause undesired operation.

This equipment complies with FCC radiation exposure limits for an uncontrolled environment. Install and operate with a minimum distance of 20cm between the radiator and your body.

French IC Warning: Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes : (1) Ce dispositif ne peut causer d'interférences ; et (2) Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de l'appareil.

Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayon.

Important - Grounding Method

This product has a three-pronged grounded plug. Plug into a mating grounding-type receptacle in accordance with the National Electrical Code and applicable local codes. If the circuit lacks a grounding receptacle, the customer must exchange the existing receptacle. Never cut or remove the ground prong.

Never use the cord, plug, or appliance if damaged. Do not use with an extension cord unless tested by a qualified supplier. Improper grounding can result in fire, electric shock, or injury.

Consult a qualified service representative if unsure about grounding.

Electrical Connections

Before plugging in:

  • Verify mains power supply matches the rating plate.
  • Ensure the power socket and circuit are adequate.
  • Check that the mains socket matches the plug. Replace plug if necessary.
  • Ensure the mains socket is adequately earthed.

Failure to follow these instructions absolves the manufacturer of liability.

Description

The appliance includes a control panel, deflector, display screen, handles, castors, intake grilles, remote controller holder, power cable, air outlet grille, condenser drain, plug fixer, and middle drainage port.

Accessories:

  • Exhaust hose (1 set)
  • Hose outlet (1 set)
  • Hose inlet (1 set)
  • Window slider kit (1 set)
  • Window slider without hole (1 set)
  • Screw (1 set)
  • Remote Control (1 set)
  • Batteries (Two AAA 1.5V) (1 set)
  • Drain Hose (1 pc)
  • Window Sealing Sponge Assembly (1 set)

Illustrations are for explanatory purposes; your appliance may differ slightly. Ensure all accessories are removed from packing before use.

Installation Instructions

Place the unit close to a window or opening for the exhaust hose. Ensure at least 18" (45cm) clearance around the unit and proximity to a single circuit outlet.

  1. Extend the exhaust hose and screw the hose inlet to one end (refer to Fig. 1 & 2).
  2. Extend the other side of the hose and screw it to the hose outlet (refer to Fig. 3).
  3. Install the hose inlet into the unit (refer to Fig. 4A/4B).
  4. Affix the hose outlet into the window slider kit and seal (refer to Fig. 5 & 6).

The window slider kit fits most standard windows. If the window opening is smaller than the kit, cut the end *without* the hole. Never cut the end *with* the hole.

Window Slider Kit Installation:

  1. Parts: Panel (A), Panel with one hole (B), Panel without hole (C, may not be supplied), Screw (D).
  2. Assembly: Slide Panels B and C into Panel A, adjusting to window width. Ensure no gaps or air pockets.
  3. Lock the screw into the corresponding holes to secure the kit and eliminate gaps.

Window Sealing:

  1. Cut and attach foam seal to the window sash.
  2. Attach the window slider kit to the sash, adjusting length and cutting if necessary.
  3. Cut and attach foam seal to the top of the window.
  4. Close the window securely against the slider kit.
  5. Secure the kit to the window sash.
  6. Seal the gap between the top window frame and outer frame with foam seal.

Location:

Place the unit on a firm, smooth, level floor to minimize noise and vibration. Use casters on smooth surfaces; protect wood floors. Do not roll over objects.

Ensure proximity to a grounded socket. Keep air inlet/outlet clear of obstacles.

Allow at least 18" (45cm) space from walls for efficient cooling.

Keep the exhaust hose as short as possible with no sharp bends or sags.

Description of the Display Screen

The display screen shows:

  • [Cool Mode] symbol
  • [Heat Mode] symbol (for heat pump models)
  • Fan Speed Indicator
  • [Timer] symbol
  • Temperature symbol
  • Temperature indicator
  • [Wi-Fi] symbol (for Wi-Fi models)

When connected to a phone, the [Wi-Fi] symbol illuminates. Refer to the Wi-Fi manual for connection instructions.

Operating from the Control Panel:

The control panel allows basic functions without the remote.

Power ON/Standby:

Plug in the unit; it enters standby mode. Press the [Power Button] to turn it on. It resumes the last used function.

Never turn off by unplugging. Always use the [Power Button], wait a few minutes, then unplug.

COOL Mode:

Ideal for cooling and dehumidifying. Press the [Cool Mode] button. Select target temperature (64-90°F / 18-32°C) using [Up]/[Down] buttons. Select fan speed (High, Med, Low, Auto) using the [Fan Speed] button.

Recommended summer temperature: 75-81°F (24-27°C). Set temperature not too far below outdoor temperature.

HEAT Mode (Heat Pump Models Only):

Press the [Heat Mode] button. Select target temperature (55-81°F / 13-27°C). Select fan speed (High, Med, Low, Auto).

Water is collected in the tank. When full, the unit shuts down and displays "[Full Tank]". Empty the tank as described in "Water Drainage Method".

During defrosting (indicated by a symbol), noise may change. Hot air may take minutes to appear. Fan may run briefly after reaching temperature.

FAN Mode:

Air hose is not required. Press the [Fan Mode] button. Select fan speed (High, Med, Low).

DRY Mode:

Ideal for reducing humidity. Attach the exhaust hose to discharge moisture outside. Press the [Dry Mode] button. Fan speed is automatic and cannot be set manually.

Switch Temperature Unit:

Hold the [Up] and [Down] buttons together for 3 seconds to switch between Celsius and Fahrenheit.

Self-Diagnosis:

The unit has a self-diagnosis system. Error messages appear on the display:

  • LOW TEMPERATURE (Frost Prevention): Unit has frost protection. It restarts automatically after defrosting.
  • PROBE FAILURE (Sensor Damaged): Contact authorized service center.
  • FULL TANK (Safety Tank Full): Empty the internal safety tank (see "End of Season Operations").

Manual of Remote Control

Buttons include: On/Off, Increase, Decrease, Timer, Unit Switch, Fan Speed, Mode, Swing, Sleep, Turbo (if available), Child Lock.

Display shows: [Cool Mode], [Dry Mode], [Fan Mode], [Heat Mode] symbols, Fan Speed, Timer ON/OFF, Turbo, Sleep, Child Lock symbols.

Operation: Point remote at the appliance receiver, within 7 yards, without obstacles. Handle with care. Replace batteries if not working.

Inserting/Replacing Batteries: Remove rear cover, insert two "AAA" 1.5V batteries correctly, replace cover.

Dispose of batteries according to legislation. Do not mix battery types. Do not dispose of in fire. Remove batteries if not used for a long time.

Remote Control Modes:

  • COOL Mode: Select [Cool Mode] symbol. Set temperature (64-90°F / 18-32°C) and fan speed (High/Medium/Low/Auto).
  • HEAT Mode: Select [Heat Mode] symbol. Set temperature (55-81°F / 13-27°C) and fan speed (High/Medium/Low/Auto). (Note on defrosting and heat delivery applies as per control panel section).
  • FAN Mode: Select [Fan Mode] symbol. Set fan speed (High/Medium/Low).
  • DRY Mode: Select [Dry Mode] symbol. Exhaust hose must be attached. Fan speed is automatic.
  • SMART Mode: This model does not have SMART mode; it defaults to FAN mode.
  • Turbo Function: This model does not offer this function.
  • SWING Function: Press the [Swing] button to start/stop the deflector's up/down swing.
  • SLEEP Function: Select COOL or HEAT mode. Press the [Sleep] button. Screen brightness reduces, fan speed becomes Low. In COOL mode, temperature increases by 1° per hour for 2 hours, then maintains for 6 hours before shutting down. In HEAT mode, it maintains optimum temperature with gradual variations for comfort. Cannot be set in FAN or DRY mode. Cancel by pressing Sleep, Mode, or Fan Speed buttons.

Programming Start-up/Shut Down:

Start-up: Turn appliance on, select desired mode/settings. Turn off. Press [Timer] button twice. Display shows 0.5-24 hours and timer symbols. Use [Up]/[Down] to set time. Press [Timer] again to activate. Timer symbol appears. Press [Timer] or [Up]/[Down] to cancel.

Shut Down: Appliance running. Press [Timer] button. Display shows 0.5-24 hours and timer symbols. Use [Up]/[Down] to set time. Press [Timer] again to activate. Timer symbol appears. Press [Timer] or [Up]/[Down] to cancel.

Switch Temperature Unit:

When appliance is running, press the [Unit Switch] button to change between Celsius and Fahrenheit.

CHILD-LOCK Function:

Hold the [Child Lock] and another button (likely Up/Down or Mode) for 3 seconds to activate/deactivate. [Child Lock] symbol appears when active. Prevents accidental changes.

Tips for Correct Use

  • Close windows and doors. For semi-permanent installation, leave a door slightly ajar (1 cm) for ventilation.
  • Protect room from direct sun using curtains/blinds for economy.
  • Do not place objects on the appliance.
  • Do not block air inlet/outlet; reduced airflow impairs performance and can damage the unit.
  • Eliminate heat sources in the room.
  • Do not use in very damp rooms (e.g., laundries).
  • Do not use outdoors.
  • Ensure appliance is on a level surface. Use castor locks if needed.

Water Drainage Method

When the internal water tank is full, the appliance stops and displays "[Full Tank]". Drain the condensation:

Manual Draining:

  1. Unplug the unit.
  2. Place a drain pan under the lower drain plug.
  3. Remove the lower drain plug.
  4. Allow water to drain into the pan.
  5. Replace the lower drain plug firmly.
  6. Turn the unit on.

Continuous Draining:

Recommended for Dry mode. 1. Unplug the unit. 2. Remove the drain plug (some water may spill; use a pan). 3. Connect the drain hose (1/2" or 12.7mm). 4. Drain water into a floor drain or bucket. 5. Turn on the unit.

Ensure the drain hose height is not higher than the drain outlet to prevent drainage issues.

Middle Drainage:

For Dry mode: 1. Unplug the unit. 2. Remove the drain cap (some water may spill; use a pan). 3. Connect the drain hose (1/2" or 12.7mm). 4. Drain water into a floor drain or bucket. 5. Turn on the unit.

Condensate may flow out after removing the drain cap. Prepare a drip tray when removing the hose. Ensure drain hose height is not higher than the drain outlet. For maximum performance in Cool mode, it is recommended to disable continuous drainage by replacing the drain cap.

Cleaning

Turn off the appliance using the [Power Button] or remote, wait a few minutes, then unplug before cleaning.

Cleaning the Cabinet:

Wipe with a slightly damp cloth, then dry. Never wash with water, petrol, alcohol, solvents, or spray insecticides.

Cleaning the Air Filters:

Clean filters weekly for efficiency. The evaporator filter can be removed as shown in Fig. 28. Avoid contact with metal parts to prevent cuts.

The condenser filters are two pieces. Remove them as shown in Fig. 29, 30-31. Avoid contact with metal parts.

Use a vacuum cleaner for dust. If very dirty, immerse in warm water (max 104°F / 40°C), rinse, and dry thoroughly before re-attaching.

Start-End of Season Operations

Start of Season Checks:

Ensure power cable and plug are undamaged and the earth system is efficient. Follow installation instructions.

End of Season Operations:

To empty the internal circuit, remove the cap (fig. 32), drain water into a basin, and replace the cap. Clean and dry filters thoroughly before storing.

Technical Specifications

Mains voltage: See rating label.

Maximum power in cooling mode: See rating label.

Refrigerant: See rating label.

Cooling capacity: See rating label.

Strictest operation environment:

  • Cooling mode: 18-35°C (64-95°F), 30%RH~90%RH
  • Heating mode: 10-25°C (50-77°F), 30%RH~90%RH

Troubleshooting

Room Conditions:

  • Cooling: 18-35°C (64-95°F)
  • Heating: 10-25°C (50-77°F)
PROBLEMCAUSESOLUTION
The appliance does not come onNo current / Not plugged in / Internal safety device trippedCheck power supply / Plug in unit / Wait 30 minutes; if persists, contact TCL customer service.
The appliance works for a short time onlyBends in exhaust hose / Obstruction to air discharge / Open windows/doors/curtains / Heat sources in room / Hose detached / Appliance inadequate for room size / Clogged air filterPosition hose correctly (short, no curves) / Check and remove obstacles / Close doors, windows, curtains / Eliminate heat sources / Refit hose / Ensure appliance is suitable for room / Clean filter.
The appliance works, but does not cool the room(See above causes)(See above solutions)
During operation, there is an unpleasant smell in the room(Potential causes not specified, but filter cleaning is recommended)Clean filters as described above.
The appliance does not operate for about three minutes after restarting itInternal compressor safety device prevents restart until three minutes have elapsed.This is normal operation; unit will operate after three minutes.
Error messages on display (e.g., LOW TEMPERATURE, PROBE FAILURE, FULL TANK)Self-diagnosis system identifies malfunctions.Refer to the SELF-DIAGNOSIS section above for specific actions.
Models: ZCP08SA, ZCP10SA, ZCP12SA, Portable Air Conditioner, ZCP Serise Portable Air Conditioner, Air Conditioner, Portable AC, AC

File Info : application/pdf, 32 Pages, 23.71MB

PDF preview unavailable. Download the PDF instead.

ZoneAire Compact Portable Installation and Operations Manual TCL Corel PDF Engine Version 17.1.0.572

Related Documents

Preview Friedrich Go WiFi Setup Guide for Single Hose Portable Air Conditioners
A comprehensive guide to setting up and controlling your Friedrich single hose portable air conditioner using the Friedrich Go WiFi app. Learn how to connect to WiFi, manage device settings, and troubleshoot common issues.
Preview Friedrich Electronic Window Air Conditioner Operating Instructions
Comprehensive operating instructions for Friedrich Electronic Window Air Conditioners, covering safety, installation, operation, maintenance, and troubleshooting for models CCW15B10A, CCW18B30A, CCW24B30A, CEW18B33A, and CEW24B33A.
Preview Friedrich Uni-Fit Through-the-Wall Air Conditioners: Smart, Quiet, Efficient Cooling
Discover the Friedrich Uni-Fit Series of through-the-wall room air conditioners, featuring smart Wi-Fi control, QuietMaster technology for superior quietness, and energy-efficient operation. Explore model specifications and installation benefits.
Preview Friedrich ZoneAire ZCP12DB Portable Air Conditioner Use and Care Manual
Comprehensive guide for the Friedrich ZoneAire ZCP12DB portable air conditioner, covering operation, installation, maintenance, and troubleshooting. Learn how to use your unit safely and efficiently.
Preview Friedrich ZoneAire ZHP14DB Portable Air Conditioner User Manual
Comprehensive user manual for the Friedrich ZoneAire ZHP14DB portable air conditioner, covering safety, operation, maintenance, and troubleshooting to ensure optimal performance and longevity.
Preview Friedrich Air Conditioner Wi-Fi Operation Manual
This manual provides comprehensive instructions for operating Friedrich air conditioners with Wi-Fi functionality, including setup, troubleshooting, and app control for models like Friedrich Connect, Friedrich Go, Kuhl, Kuhl Q, Wallmaster, FA Pro, FA Premier, and Chill Premier/Unifit.
Preview Friedrich Uni-Fit Air Conditioner Installation and Operation Guide
Comprehensive guide for installing and operating Friedrich Uni-Fit air conditioners, including safety precautions, electrical data, operating instructions, care and maintenance, and troubleshooting.
Preview Friedrich KHVS12B33A Room Air Conditioner Specifications | ENERGY STAR Certified
Detailed specifications for the Friedrich KHVS12B33A Room Air Conditioner, an ENERGY STAR certified product. Includes cooling capacity, energy efficiency, dimensions, and more.