Owner's Manual for MEAN WELL models including: SE-600-5 Single Output Power Supply, SE-600-5, Single Output Power Supply, Output Power Supply, Power Supply, Supply
Mechanical Specification Derating Curve Static Characteristics Case No. 926A Unit:mm AMBIENT TEMPERATURE (℃) L O A D (%) L O A D (%) 20 40 60 80 100 INPUT VOLTAGE (VAC) 60Hz
File Info : application/pdf, 2 Pages, 814.39KB
DocumentDocument600W Single Output Power Supply SE-600 series User's Manual IS 15885(Part 2/Sec13) THOMAS SAMUEL THOMAS SAMUEL SPECIFICATION R-41027766 (except for 48V) K60950-1 IEC62368-1 (for 12V,24V only) (Note.5) MODEL SE-600-5 SE-600-12 SE-600-15 SE-600-24 SE-600-27 SE-600-36 SE-600-48 OUTPUT DC VOLTAGE 5V 12V 15V 24V RATED CURRENT 100A 50A 40A 25A CURRENT RANGE 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 25A RATED POWER 500W 600W 600W 600W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 10 ~ 13.5V 13.5 ~ 16.5V 22 ~ 26.4V VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±2.0% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load 27V 22.2A 0 ~ 22.2A 599.4W 150mVp-p 24 ~ 30V ±1.0% ±0.5% ±0.5% 36V 16.6A 0 ~ 16.6A 597.6W 200mVp-p 32 ~ 40V ±1.0% ±0.5% ±0.5% 48V 12.5A 0 ~ 12.5A 600W 200mVp-p 43 ~ 56V ±1.0% ±0.5% ±0.5% HOLD UP TIME (Typ.) 20ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) 78% 83% 84% 12A/115VAC 7.5A/230VAC 87% 87% 87% 88% INRUSH CURRENT (Typ.) 30A/115VAC 60A/230VAC LEAKAGE CURRENT <2.0mA / 240VAC OVERLOAD 105 ~ 125% rated output power Protection type : Shut down o/p voltage, re-power on to recover PROTECTION OVER VOLTAGE OVER TEMPERATURE 5.75 ~ 6.3V 13.8 ~ 16.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 42 ~ 50V Protection type : Shut down o/p voltage, re-power on to recover 85±5 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 57.6 ~ 67.2V WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ±0.05%/ (0 ~ 50) SAFETY & EMC OTHERS NOTE VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS CB IEC62368-1, UL60950-1,UL62368-1, EAC TP TC 004, BSMI CNS14336-1, KC K60950-1(for 12V,24V only), IS13252(Part1)/IEC60950-1(except for 48V) approved; Design refer to BS EN/EN62368-1 WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC MTBF 1529.1K hrs min. Telcordia TR/SR-332 (Bellcore) ; 204.2K hrs min. MIL-HDBK-217F (25) DIMENSION 247*127*63.5mm (L*W*H) PACKING 2.1Kg; 6pcs/13.4Kg/1.03CUFT . https://www.meanwell.com/serviceDisclaimer.aspx 600W Single Output Power Supply Mechanical Specification 14 max. 4-M3 L=4 11 220 247 230/115VAC 10 8.2 Air flow direction 1 2 I/P 3 220 4-M3 L=4 SE-600 series 17 max. Case No. 926A Unit:mm 30 20 63.5 1 10 13 127 2 3 O/P 4 5 6 CN4 RS + +Adj. R S +- 16 20 30 AC input terminal : Pin No. Assignment 1 AC/L 2 AC/N 3 FG Block Diagram EMI I/P FILTER FG Derating Curve DC Output terminal : Pin No. Assignment 1~3 +V 4~6 -V RS Connector (CN4) : JST B-XH or equivalent Pin No. Assignment Mating Housing Terminal 1 +S JST XHP JST SXH-001T 2 -S or equivalent or equivalent RECTIFIERS & FILTER O.T.P. POWER SWITCHING RECTIFIERS & FILTER O.L.P. DETECTION CIRCUIT PWM CONTROL O.V.P. Static Characteristics fosc : 68KHz +V -V 100 80 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 100 Other 90 5V 80 70 60 50 40 90 95 100 115 180 190 200 230 INPUT VOLTAGE (VAC) 60Hz 130 260 Made in China LOAD (%) LOAD (%)