Instruction Manual for TKH Security models including: EX3 PTZ Series 3rd Generation EX PTZ Camera 316L, EX3 PTZ, Series 3rd Generation EX PTZ Camera 316L, Generation EX PTZ Camera 316L, PTZ Camera 316L
» EX3-PTZ series
File Info : application/pdf, 38 Pages, 2.60MB
DocumentDocumentTKH EX3 PTZ Series Installation manual 3rd Generation EX PTZ Camera 316L Copyright © 2024 TKH Security. Version 1.1. TKH Security | Siqura EX-PD24 | Installation manual 1 TKH Security Proposal | RFP Name | RFP Number Note: To ensure proper operation, please read this manual thoroughly before using the product and retain the information for future reference. Nothing from this publication may be copied, translated, reproduced, and/or published by means of printing, photocopying, or by any other means without the prior written permission of TKH Security. TKH Security reserves the right to modify specifications stated in this manual. Brand names Any brand names mentioned in this manual are registered trademarks of their respective owners. Liability TKH Security accepts no liability for claims from third parties arising from improper use other than that stated in this manual. Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant product components, this manual may nonetheless contain errors and inaccuracies. We invite you to offer your suggestions and comments by email via info@tkhsecurity.com. Your feedback will help us to further improve our documentation. How to contact us If you have any comments or queries concerning any aspect related to the product, do not hesitate to contact: TKH Security B.V. Werner von Siemensstraat 7 2712 PN Zoetermeer The Netherlands http://tkhsecurity.com TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 2-38 TKH Contents Contents ............................................................................................................................. 3 Introduction ......................................................................................................................... 4 General information............................................................................................................. 5 Before you continue ............................................................................................................ 7 Certificates .......................................................................................................................... 9 Special conditions for safe use.......................................................................................... 10 Unpacking ......................................................................................................................... 11 Installation......................................................................................................................... 12 Maintain the unit................................................................................................................ 24 Technical Data .................................................................................................................. 26 EX Marking plate............................................................................................................... 28 Sync IR with D/N mode ..................................................................................................... 31 EU Certificates .................................................................................................................. 33 Appendix: Technical drawings........................................................................................... 36 TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 3-38 TKH Introduction Preserve this manual as a reference for future needs. Used electrical, electronic and stainless steel products should not be mixed with general waste. For proper treatment, recovery and recycling of old products, take them to applicable collection points, in accordance with your national legislation and the Directives 2011/65/EU and 2012/19/EU. By disposing of these products correctly, you help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products, contact your local municipality or your waste disposal service. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. The manufacturer declines all liability for any consequence resulting from improper installation practices, tampering or improper uses of the product. The descriptions and illustrations contained in this manual are not binding. The manufacturer reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication. The manufacturer declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documents. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 4-38 TKH General information Description The EX3-PTZ series are AISI 316L Stainless Steel camera housings specifically designed for Hazardous Area applications. Built with belt-drive technology, EX3-PTZ allows PAN and TILT rotations with very low power consumption. The EX3-PTZ can be assembled the latest generation zoom module day/night and/or thermal imaging modules (TX3). Note: This product must only be installed by suitably trained personnel in accordance with the relevant code of practice (e.g., EN60079-14 or ABNT NBR IEC 60079-14).. These instructions are intended for their sole use. Models This manual contains instructions on installation and use of the EX3-PTZ series. It covers the following models: EX3-PTZ(v). Single head optical upright pan, tilt, and zoom camera EX3-PTZ(v)T. Single head thermal upright pan and tilt camera EX3-PTZ(v)D. Dual head optical + thermal upright pan, tilt, and zoom camera EX3-PTZ(v)D-IR34. Dual head optical upright pan, tilt, and zoom camera with IR illuminator (v) determines the power supply voltage. (v) can be 24 for AC 24 V, 120 for AC 120 V or 230 for AC 230 V Symbols used WARNING It indicates a potentially dangerous situation that, if ignored, could lead to physical or mortal injuries and/or damage to the unit. Read the provided instructions carefully. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 5-38 TKH Security Proposal | RFP Name | RFP Number ELECTRICAL HAZARD It indicates a potentially dangerous situation involving electricity risks that could lead to physical or mortal injuries and/or damage to the unit. Read the provided instructions carefully. EXPLOSION RISK It indicates a potentially dangerous situation involving an explosive atmosphere that can be caused by flammable gases, mists, vapours or by combustible dusts. The effects of an explosion can be devastating in terms of lost lives, injuries, significant damage to property and environment, and to the business community. Read the provided instructions carefully. OPTICAL RADIATION It indicates a potentially dangerous situation due to the emission of visible light or infrared that could be harmful for eyes. Read the provided instructions carefully. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 6-38 TKH Before you continue Prior to installation and operation, carefully read all instructions in this manual and heed all warnings. Use the original packaging to transport the unit. Disconnect power supply before moving it. In case of returning the equipment, the original packaging must be used. Any change performed on the unit that is not previously approved by the manufacturer will void both the certification and the warranty. If this equipment is not utilized according to the instructions of this document, the protection of the equipment may be impaired and the certification may be void. Trying to manually force the wiper will result in damaging the device and will void the warranty. When leaving the unit unused for long periods, disconnect supply cables For security reasons, do not install the unit in the proximity of water containers and never push objects or pour liquids into the unit. The unit can be safely used in damp environments or outdoors, as long as the glands are properly sealed. The internal transformer of the unit should never be used to power external devices. Connecting GND/Earth/PE to line or neutral will result in damaging the device and will void the warranty. No ventilation is needed for the unit, as it is completely sealed. Before performing any operation, turn off the power. The installation of the unit can be performed only by qualified personnel in accordance with the relevant code of practice (e.g., EN60079-14, ABNT NBR IEC 60079-14, etc) and with all the relevant local and national standards including but not limited to the use of special pipes, tapes, sealants, cables and glands. All the electrical connections should be realized in a non-explosive atmosphere. Only for EX3-PTZD IR34 with integrated IR LED illuminator: The unit emits high intensity IR light. Wear protective eyewear. Avoid direct eye and skin exposure. Please follow safety precautions given in IEC 60825-1 and IEC 62471. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 7-38 TKH Security Proposal | RFP Name | RFP Number Technical Data General & Mechanical Construction: Finishing: Pan: Tilt: AISI316L Stainless Steel Electro-polished Angle: 360° (continuous rotation); Speed: 0 40°/second Angle: 180° (±90°); Speed: 0 20°/second Electrical Heater: Power consumption: EX3-PTZ(v) EX3-PTZ(v)D EX3-PTZ(v)D-IR34 Supply voltage: (v) = 24 (v)= 120 (v)= 230 T[°C] ON=12±4°C, T[°C] OFF=20±3°C (thermostatically controlled) 130W MAX 170W MAX 155W MAX AC 24V (±10%) AC 120V (±10%) AC 230V (±10%) Certifications Weatherproof standard: IP66/IP67/IP68/IP69 ATEX/UKEX Standards: EN IEC 60079-0:2018; EN 60079-1:2014; EN 60079-31:2014 IECEx Standards: IEC 60079-0:2017; IEC 60079-1:2014-06; IEC 60079-31:2013 INMETRO Standards (TBD) ABNT NBR IEC 60079-0:2020; ABNT NBR IEC 60079-1:2016; ABNT NBR IEC 60079-31:2022 CE compliant TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 8-38 TKH Certificates EX3-PTZ, EX3-PTZT and EX3-PTZD The 3rd generation explosion proof camera stations have been designed and certified to the ATEX Directive 2014/34/EU, to the UKSI 2016:1107 (as amended by UKSI 2019:696) to the following: II 2 G Ex db IIC T6/5/4 Gb -60°C Tamb +60/75/80°C II 2 D Ex tb IIIC T85/100/135°C Db -60°C Tamb +60/75/80°C This product is designed for use with flammable gases and vapours covered by apparatus groups IIA, IIB and IIC with temperature classes T1 to T6 (environmental temperature up to 60°C), with temperature classes T1 to T5 (environmental temperature up to 75°C), with temperature classes T1 to T4 (environmental temperature up to 80°C) and with flammable dust covered by apparatus groups IIIA, IIIB and IIIC with temperature T=85°C. EX3-PTZD-IR34 The explosion proof PTZ camera stations with integrated IR LED illuminator has been designed and certified to the ATEX Directive 2014/34/EU, to the UKSI 2016:1107 (as amended by UKSI 2019:696) to the following: II 2 G Ex db IIC T5/4 Gb -60°C Tamb +40/60°C II 2 D Ex tb IIIC T100/135°C Db -60°C Tamb +40/60°C This version of the product is designed for use with flammable gas and vapours covered by apparatus groups IIA, IIB and IIC with temperature classes T1 to T5 (environmental temperature up to 40°C) and with temperature classes T1 to T4 (environmental temperature up to 60°C) and with flammable dust covered by apparatus groups IIIA, IIIB and IIIC with temperature T=100°C. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 9-38 TKH Special conditions for safe use Do not damage, modify or repair the flame-paths. The mechanical and physical properties of the fasteners used for the covers shall be A4-70 according EN-ISO 3506-1 The temperature at the cable entry can reach 25°C higher than the ambient operating temperature. Select suitable cable and glands that meet the requirements for max 105°C ambient temperature. For fixed installation - part of the enclosure may be capable of generating electrostatic charges under certain extreme conditions. The user should ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam) which might cause a build-up of electrostatic charges on nonconducting surfaces. Additionally, cleaning of the equipment should be done only with a damp cloth.. The camera must be installed in an area of low risk of impact. The power dissipated within the camera housing shall not exceed 25 W (or 40 W in case of redundant thermal protection set to open no higher than 35 °C). The motor housing enclosures must be fitted with suitable thermal limiting devices as defined on the associated drawings. When a fibre optical cable is used on the equipment it shall be suitably protected against mechanical damage external to the equipment (wire armoured cable, fitted in conduit, within a cable tray etc) in accordance with IEC/EN 60079-14 The cross-sectional area occupied by the internal equipment within the camera housing shall not exceed 60%. When coin cells are fitted, the equipment must be marked for limited use at -40°C. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 10-38 TKH Unpacking Contents in the box The camera comes in a sturdy carton box with the following contents:: Explosionproof camera station Hard copy of this manual Washing nozzle brackets kit (versions with wiper only) Unpack If the package or the contents appears to be damaged, notify the shipper immediately. Check that all parts listed above are included. Use suitable lifting equipment that complies with all applicable (local) standards.. The unit must be harnessed with a suitable anchor strap (minimum capacity: 500kg, minimum length: 2m) 1. Pass the anchor strap (1) under the unit 2. Pass the strap through the end of loop and tighten (2). 3. Pull the strap to tilt the unit in vertical position while still in the box 4. Lift the PTZ out of the box. Be careful to any sudden movements of the unit while lifting. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 11-38 TKH Installation Before you begin Proper stainless steel tools should be carefully chosen and used during installation and to fasten the unit to the surfaces, in accordance with the local requirements. The unit cannot be installed horizontally. Make sure that the installation surface can support at least four times the weight of the unit in normal operating conditions. Where the equipment may be exposed to excessive external stresses (e.g., vibration, heat, impact), then the equipment must be protected by additional means of protection. Additional protection may be required if the equipment is to be installed in locations where it may be subject to damage. It is not advised to use automatic tools (such as drill drivers) for tightening/loosening the screws, it may result in damaged threads. Use caution when lifting and (dis)assembling the unit. It is recommended that non-slip protective gloves be worn during installation. The unit could bear sharp edges Electrical connections (such as plugs and cords) must be protected from potential hazardous environmental factors (e.g., foot traffic, hitting objects). Earth ground attachment point is a stud M5-0.8 x20 A4-70 ISO 4762 with dual nut and dual serrated washer. During installation it is important to connect the Earth stud to an appropriate grounding location using a (minimum) 6 mm2 / 10 AWG copper stranded wire. Make sure that the unit case is properly earthed, connecting all the earth ground studs. An all-pole mains switch with an opening distance between the contacts at least 3 mm (1/8'') in each pole must be incorporated in the electrical installation. The switch must be equipped with protection against the fault current towards the ground (differential) and the overcurrent (magnetothermal, maximum 15 A). It must be very quickly recognizable and readily accessible Recommended fuse for 115 Vac / 230 Vac: 2 A Delayed Fuse T (Time delay) or equivalent resettable devices. Recommended fuse for 24 Vac: 4 A Delayed Fuse T (Time delay) or equivalent resettable devices. For connection to the main power supply use suitably insulated multipolar cable having minimum 3x1,5 mm2. The yellow/green PE wire must be longer than the others. Connecting GND/Earth/PE to line or neutral will result in damaging the device and will void the warranty. Fasten all the cables inside the housing with cables ties or other fixing means to avoid the electrical contact with surrounding parts in case the wire gets loose. Route all the cables avoiding contact with the wiper shaft and motor. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 12-38 TKH Security Proposal | RFP Name | RFP Number Do not connect the unit to a supply circuit unless the installation is completed. Check before assembling the position of the O-ring seals in their groove. Do not damage, modify or repair the flame-paths. The temperature at the cable entry can get 25°C higher than the ambient operating temperature. Select cable and gland that meets the requirement of the higher temperature. All external cables used shall meet the requirements stated in IEC/EN/ABNT NBR IEC 60079-14. Unprotected optical fiber cable shall be suitably protected using a conduit that meet the requirements stated in IEC/EN/ABNT NBR IEC 60079-14 The mechanical and physical properties of the fasteners used for the covers shall be A4-70 according EN-ISO 3506-1 TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 13-38 TKH Security Proposal | RFP Name | RFP Number Mounting the camera Zero Axis position Upon each start-up, the unit will perform a "zero-axis" calibration. "Zero-axis" position is with side flange on the left (cable entry on the back) and camera(s) facing forward. The unit should be installed with the cable gland facing the opposite direction to the zone to be monitored A I ITI Cable entry Flat surface or pole-top mount* Mount the EX3-PTZ on a flat surface which can support the unit or the top flange of a pole top . Choose the proper fasteners for surface..The screws must be tightened with suitable torque by authorized and qualified personnel only. See appendix for drawings of the mounting pattern and for the camera physical dimensions ,00 mm TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 ,00 mm 14-38 TKH Security Proposal | RFP Name | RFP Number Wall-mount To mount the EX3-PTZ camera to a horizontal wall an EX-PTZ WM01 must be used. Choose the proper fasteners for surface..The screws must be tightened with suitable torque by authorized and qualified personnel only. See appendix for drawings of the camera physical dimensions. To install the PTZ to the bracket, 4x M10 screws, 4x lock Washer and 4x nuts (provided with the EX-PTZ WM01) must be used. Check that all the threads are clean. When fixing the screws use thread locking compound (e.g., Loctite) and allow an appropriate rest period. Screws must be tightened to 38Nm with an adequate torque wrench TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 15-38 TKH Security Proposal | RFP Name | RFP Number Installing the camera Any action performed on the unit which is not described in this manual may damage the camera. Check the supply voltage marked on the label. Incorrect power supply voltage may damage the unit. Do not overload the terminal connection, as it may cause fire or electrical shock hazard. Make sure that the camera is disconnected from the power. An accessible mains switch must be installed to switch-off the power. Wait at least 5 min before opening the camera An all-pole mains switch with an opening distance between the contacts at least 3 mm (1/8'') in each pole must be incorporated in the electrical installation. The switch must be equipped with protection against the fault current towards the ground (differential) and the overcurrent (magnetothermal, maximum 15 A). It must be very quickly recognizable and readily accessible Open only the covers pointed out in this installation manual. Other covers should be open only by the manufacturer. Make sure the threads of the unit are free of dirt and debris. A minimum of 10mm depth and 5 threads of engagement must be maintained for all threaded holes Make sure the camera is tightly closed when operating or energized. Do not connect the unit to a supply circuit unless the installation is completed. Check before assembling the position of the O-ring seals in their groove. Installation of armored composite cable (INT3) The armored composite cables from TKH Security are pre-fitted with the proper Ex d barrier gland on each side for ease of installation. The following tails are available: INT3-RJ5, 5 meter armored composite cable for Fast ethernet INT3-RJ10, 10 meter armored composite cable for Fast ethernet INT3-SM5, 5 meter armored composite cable with SM fiber INT3-SM10, 10 meter armored composite cable with SM fiber INT3-MM5, 5 meter armored composite cable with MM fiber INT3-MM10, 10 meter armored composite cable with MM fiber If the composite cable tail isn't provided by TKH Security, please check the correct cable gland thread dimension. To maintain the certification requirements and the IP rating of the unit, use only cables, cable glands, blind-stops, adapters that are suitably certified and rated for associated ambient range. Plastic caps are used to close cable entries during shipment, remove them and close off any unused cable entries with a appropriate certified blind-stop. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 16-38 TKH Security Proposal | RFP Name | RFP Number Remove plastic cover (1. Remove screws (2) and lower flange (3) Loosening the back-nut (4) and the middlenut (5) Insert plastic washer (6) and tighten the nut Tighten the middle-nut (5) to 50Nm (7). Tighten the back-nut (4). TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 17-38 TKH Security Proposal | RFP Name | RFP Number Electrical wiring If necessary, remove locking screw (1) and slide out the PCB to have a better access to the other terminal blocks. M1 and M7 terminal blocks can be removed from PCB to perform electrical connections. Telemetry board Interface board ID DIS1 Name RS485 settings S1 Reset button Notes Do not change settings. Used for setting the unit address and baud rate of camera station. PIN 1-6: PTZ Address ID (Default on address 1) PIN 7-8: DIS1-7 DIS1-8 Baud rate OFF OFF 2400 (Default) OFF ON 9600 ON OFF 19200 ON ON 57600 Push 15 seconds to reset to default settings. CAUTION: this operation will reset all the existing presets and the PAN/TILT axis limits. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 18-38 TKH Security Proposal | RFP Name | RFP Number Each plug-in connector is different in shape and/or colour to avoid any wrong connection. The connections should be performed according to the table below. ID M1 M4 M7 CN2 Name Supply voltage Data input (RS485) Washer control RJ45 Fast Ethernet Notes Depending on model. Please refer to marking plate supply voltage information. Not applicable AC 24 V output. Designed to activate washer systems. The activation lasts 5 seconds.. Signal out for camera. Use shielded or unshielded cable according to the needs. Fuse name F1 F2 Fuse value 8 A HT 250 VAC 5x20 10 A HT 250 VAC 5x20 TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 19-38 TKH Security Proposal | RFP Name | RFP Number For fiber optic versions only (INT3-SM, INT3-MM) The direct to fiber versions of the EX3-PTZ cameras are fitted with a media converter in the base of the unit. Connect both optical fiber pigtails from the armored to the media converter. The converter is fitted with two SC connectors. Telemetry board Interface board Closing the camera base Check if the O-Ring gasket (4) is in its grove before proceeding. Assemble the rear flange (5) in the PTZ and tight the screws (6) to 11Nm TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 20-38 TKH Security Proposal | RFP Name | RFP Number Opening and closing camera house To access the IP camera or IR illuminator follow these instructions to open the camera house. A. Opening: Remove screws (1) from the window flange of the camera housing (2). Rotate the flange 45 clockwise while sliding it out. In case of an IRilluminator, the camera flange has to be rotated 45 counterclockwise B. Closing: Slide the camera assembly (2) in the camera housing while rotating it 45° clockwise. Tight the screws (1) to 11Nm. In case of an IR-illuminator rotate 45 counter clockwise Check if the O-Ring gasket (3) is inside its grove before proceeding A: Access the IP-camera A: Access the IR-Illuminator B: Closing the camera house B: Closing the Illuminator house TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 21-38 TKH Security Proposal | RFP Name | RFP Number IR LED illuminator (PTZ D-IR only) Connector Name M1 AC/DC Power supply Input M6 Inputs S1 Test LED Color DL1 Green DL2 Yellow DL3 Red DL4 Yellow Notes AC 24V Dry contact/Open collector (NPN) input for IR LEDs activation (Example: external camera output) Used for manual IR LEDs activation test. Indication is ON when the board is correctly powered is ON when the IR LEDs are interrupted (open-led) is ON when the IR LEDs are not activated or when they are in short-circuit. is ON when the IR LEDs are in the activation phase during its hysteresis delay TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 22-38 TKH Security Proposal | RFP Name | RFP Number Grounding Connect earth cable to the PTZ base, under the nuts and screws (1), with M5 eyelet terminal. Installing the washer nozzle Fix the nozzle bracket on the PTZ with the provided nuts and washers (1). Connect earth cable to the PTZ base, between nozzle bracket and screws (1), with M5 eyelet terminal. Adjust horizontal position of the nozzle, use the screwdriver slot (3) on the nozzle to adjust the tilt position TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 23-38 TKH Maintain the unit Please read and be familiar with the following instructions before servicing the unit. Ensure proper operating condition of the unit performing safety checks upon completion of maintenance. Disconnect the unit from the supply circuit before cleaning. Do not use caustic or abrasive cleaning products. Use only original replacement parts from TKH Security. Inspection and maintenance of the equipment must be carried out in accordance with the applicable standards (i.e. EN 60079-17). Repair of the equipment must be carried out in accordance with the applicable standards (i.e. EN 60079-19) Disconnect the unit from the supply circuit and report to qualified service personnel whenever any damage or deformation to the equipment has been detected. Do not use equipment that looks worn or old. Inspections This equipment has been designed to fit in harsh environments requiring little or no maintenance. Suggested inspection interval is six months, but extremely harsh environments may require more frequent inspection and maintenance checks. On each inspection, check the O-ring seals and the window wiper blade integrity. Replace them when necessary. Routine activities Regularly perform the following routine activities: Clean the glass Use water or a liquid detergent that will not generate a hazardous situation. Clean the germanium window Remove the protective guard, unscrewing the screws using a no-sparking hex wrench. Use water or a liquid detergent that will not generate a hazardous situation. Be careful not to scratch the carbon coating. Do not use ethyl alcohol, solvents, hydrogenated hydrocarbons, strong acids or alkalis. This will irreparably damage the germanium window. Once completed the cleaning, properly reassemble the protective guard. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 24-38 TKH Security Proposal | RFP Name | RFP Number Clean the unit The layer of filth upon the unit should never exceed 5 mm thickness. Use a dry or damp cloth. Do not use compressed air to clean the unit. Check electrical connections Check cables and electrical connections for integrity and tightness. Replace worn cable(s) or tighten loose connections. Check mounting accessories Check mounting bolts and screws for integrity and tightness. Replace or tighten any damaged/loose mounting hardware. Extraordinary maintenance Any intervention which is not listed in the Routine activities list must be done in absence of potentially explosive atmosphere. Any repair or part replacement must be done by, or under supervision of TKH Security. Use only original spare parts. The manufacturer declines all liability for any damage resulting from tampering, use of non-original spare parts and service carried out without following the directives of the present manual. If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. Aggressive substances: acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. Suitable precautions: regular checks as part of routine inspections or establishing from the material's datasheet that it is resistant to specific chemicals. Fuse replacement If necessary, replace the fuses F1 or F2 on the interface board (see section "Electrical wiring") The following fuse values are used: Fuse name F1 F2 Fuse value 8 A HT 250 VAC 5x20 10 A HT 250 VAC 5x20 All the fuses must be ceramic T type (time lag) with a breaking capacity of 1500 A. Different supply voltage can be supplied and may require different fuse values. In such cases, please contact TKH Security. TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 25-38 TKH Technical Data Mechanical Construction Finish Pan Tilt Maximum load Cable entries AISI316L Stainless Steel Electro-polished Angle: 350° (+/- 175° or continuous rotation); Speed: up to 40°/second peak; Torque: 80 Nm Angle: 180° (+/- 90°); Speed: up to 20°/second peak; Torque: 107 Nm 25 kg M25x1.5 Electrical Thermostatically controlled heater Supply voltage Power consumption T[°C] ON = 12 ± 4 °C, T[°C] OFF = 20 ± 3 °C 24 V~ 50/60 Hz, 115 V~ 50/60 Hz, 230 V~ 50/60 Hz 95 W Max (120 W Max for EX PTZ D) Certifications EX PTZ and EX PTZ D Weatherproof standard IP66, IP68 (3m, 30min) and IP69, Nema-4x Ex II 2 G Ex db IIC T6/5/4 Gb Rating EX II 2 D Ex tb IIIC T85/100/135°C Db -60°C Tamb +60/75/80°C ATEX Standards EN 60079-0:2018; EN 60079-1:2014; EN 60079-28:2015; EN 60079-31:2014 IECEx Standards IEC 60079-0:2017; IEC 60079-1:2014-06; IEC 60079-31:2013 INMETRO ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 UKEX UKSI 2016:1107 (as amended by UKSI 2019:696) Schedule 3A, Part 1 Compliancy CE, UKCA, (INMETRO is pending) TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 26-38 TKH Security Proposal | RFP Name | RFP Number EX PTZ and EX PTZ D Certifications EX PTZ D-IR Weatherproof standard IP66, IP68 (3m, 30min) and IP69, Nema-4x Rating Ex II 2 G Ex db IIC T5/4 Gb Ex II 2 D Ex tb IIIC T100/135°C Db EN 60079-0:2018; EN 60079-1:2014; ATEX Standards EN 60079-28:2015; EN 60079-31:2014 -60°C Tamb +40/60°C IECEx Standards IEC 60079-0:2017; IEC 60079-1:2014-06; IEC 60079-31:2013 INMETRO (pending) ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 UKEX UKSI 2016:1107 (as amended by UKSI 2019:696) Schedule 3A, Part 1 Compliancy CE, UKCA, (INMETRO pending) TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 27-38 TKH EX Marking plate Every unit must carry a marking plate similar to the one above. 1. Model: Certification model name of the unit. 2. Series: Sales part number of the unit. 3. Serial No.: TKH Security serial number followed by the year of manufacturing. 4. Cable entry: Thread size of the cable entry/entries (optional). See section "Models" below. 5. Marking: see chapter "Certificates" 6. INMETRO certificate is pending TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 28-38 TKH Security Proposal | RFP Name | RFP Number Models PTZ units/camera stations EX3-PTZ(n)(a) EX3-PTZ: Pan & Tilt unit/PTZ camera station (n) Fitted number of brackets/housings (n)= 0: (n)= 1: (n)= 2: (n)= 3: (n)= 4: (a) Cable entries (a)= A: (a)= B: (a)= C: (a)= D: (a)= E: (a)= F: (a)= G: one bracket one camera housing two camera housings one camera housing and one bracket two brackets 2x M20 2x 3/4" 2x M25 1x M20 1x 3/4" 1x M25 1x M20 + 1x M25 Camera stations EX3-FIX(a)(n)(b)(c)(d) EX3-FIX: Camera housing (a) Fitted camera housing (a)= C: P&T camera housing (blank cover) (a)= F: Fixed camera housing (a)= H: P&T camera housing with rear cover (n) Housing version (n)= 0: Camera version (n)= 1: IR spotlight version (n)= 2: WIFI version (b): Window version. (b)= 0: glass window without wiper (b)= 1: glass window with wiper (b)= 2: germanium window (b)= 3: germanium window without protective guard (b)= 4: sapphire window (b)= 5: sapphire window (tilted) (c): cable entries (only for F and H version). (c) = A: 2x M20 (c) = B: 2x 3/4" (c) = C: 2x M25 (c) = D: 1x M20 (c) = E: 1x 3/4" (c) = F: 1x M25 TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 29-38 TKH Security Proposal | RFP Name | RFP Number (c) = G: 1x M20 + 1x M25 (c) = H: 1x M20 + 1x 3/4" (c) = I: 1x M25 + 1x 3/4" (c) = J: 3x M20 (c) = N: 3x 3/4" (c) = O: 3x M25 (c) = P: 4x M20 (c) = Q: 4x 3/4" (c) = R: 4x M25 (c) = T: up to 4 entries with different threads (d) housing length. (d)= S: short (d)= M: medium (d)= L: long TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 30-38 TKH Sync IR with D/N mode 1. Open the web interface; click on the "System" tab and open [Events] > [Application]. Check the boxes as shown below: 1 6 4 2 5 3 2. Click the [Manual Trigger] page and again take over the settings as shown in screenshot below: 9 8 7 TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 31-38 TKH Security Proposal | RFP Name | RFP Number 3. Click to the [Scheduling] page and take over the following settings: 11 12 10 13 With these settings the Alarm contact output is synchronized with the Day/Night mode of the camera. The Alarm output of the optical camera must be connected to M6 of the IR control board to switch on/off the IR illumina TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 32-38 TKH EU Certificates EU Declaration of conformity TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 33-38 TKH Security Proposal | RFP Name | RFP Number TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 34-38 TKH Security Proposal | RFP Name | RFP Number TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 35-38 TKH Appendix: Technical drawings EX3-PTZ and EX3-PTZ T TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 36-38 TKH Security Proposal | RFP Name | RFP Number EX3-PTZD and EX3-PTZD-IR TKH Security | Siqura EX3 PTZ Series | Installation manual v1.1 37-38 TKH Security Proposal | RFP Name | RFP Number tkhsecurity.com Our Brands Our Brands ©© 22002240,, TTKKHH SSeeccuurriittyy.. TKH Security | Siqura EX-PD24 | Installation manual 38