Aibo Standard Technology (Shenzhen) Co., Ltd.
101, Building B, Tuori New Energy Industrial Park, High-tech Park, Tianliao Community, Yutang Street, Guangming District, Shenzhen City, Guangdong Province, China
Tel.: +(86) 0755 85250797 | E-mail: Aibonorm@aibonorm.com | Website: www.Aibonorm.com
FCC TEST REPORT
Report No.: AB25060094CW02
FCC ID: 2AC59-0E926
IC ID: 32474-0E926
Applicant and Manufacturer Information
Applicant: SHENZHEN LOFREE CULTURE CO., LTD
Address: 201-F4,F518 Idea Land, 1065 Bao Yuan Road, Shenzhen
Manufacturer: SHENZHEN LOFREE CULTURE CO., LTD
Address: 201-F4,F518 Idea Land, 1065 Bao Yuan Road, Shenzhen
Product Details
Product Name: FLOW 2-68 Triple Mode Low-Profile Mechanical Keyboard
Trade Mark: Lofree
Test Model: OE926
Additional Model(s): N/A
Test Specifications
Standard(s):
- FCC 47 CFR §1.1310 - Radio frequency radiation exposure limits.
- FCC 47 CFR §2.1093 - Radio frequency radiation exposure evaluation: portable devices
- FCC KDB 447498 D01 General RF Exposure Guidance v06 - Mobile and Portable Device, RF Exposure, Equipment Authorization Procedures.
Test Dates and Result
Date of Receipt: 2025.07.03
Date of Issue: 2025.07.19
Test Result: Pass
Testing Laboratory Personnel
Compiled by: | Huaijie Li |
Supervised by: | Jay Liu |
Approved by: | Mic Cheng |
Testing Laboratory Information
Testing Laboratory Name: Aibo Standard Technology (Shenzhen) Co., Ltd.
Address: 101, Building B, Tuori New Energy Industrial Park, High-tech Park, Tianliao Community, Yutang Street, Guangming District, Shenzhen City, Guangdong Province, China
Tel: +(86) 0755 85250797
E-mail: Aibonorm@aibonorm.com
Website: www.Aibonorm.com
The test facility is recognized, certified, or accredited by the following organizations:
- A2LA-Lab Certificate No.: 7514.01
- Aibo Standard Technology (Shenzhen) Co., Ltd. has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing.
- FCC Accredited Lab.
- Designation Number: CN1411
- Test Firm Registration Number: 567066
- ISED Wireless Device Testing Laboratories
- CAB identifier: CN0185
Report Version
Version No. | Issue Date | Description |
---|---|---|
01 | 2025.07.19 | Initial Issue |
1. GENERAL INFORMATION
1.1. GENERAL DESCRIPTION OF EUT
Product Name: FLOW 2-68 Triple Mode Low-Profile Mechanical Keyboard
Trade Mark: Lofree
Test Model: OE926
Additional Model(s): /
Model Difference: /
Hardware Version: OE926-VIA-V1
Software Version: 1
Power Supply: DC 3.7V by battery(2000mAh) or DC 5V 1A from AC/DC adapter
EUT Supports Function: 2.4GHz ISM Bands: Bluetooth V5. 1
Test Sample(s) Number: AB25060094-01 (Engineer Sample), AB25060094-02 (Normal Sample)
Radio Specification Subject to this Report
Bluetooth Version: Bluetooth LE
Frequency Range: 2402MHz~2480MHz
Modulation Type: GFSK
Channel Spacing: 2MHz
Channel Number(s): 40
Antenna Type: PIFA Antenna
Antenna Gain: -0.58dBi(Max.)
1.2. DESCRIPTION OF SUPPORT EQUIPMENT
Description | Manufacturer | Model | Serial Number | Supplied by |
---|---|---|---|---|
AC/DC Adapter | Xiaomi | MDY-11-EX | SA62212LA04358J | Applicant |
1.3. DESCRIPTION OF EXTERNAL I/O
I/O Port Description | Quantity | Cable |
---|---|---|
N/A | N/A | N/A |
1.4. GENERAL DESCRIPTION OF APPLIED STANDARDS
The tests were performed according to following standards:
- FCC CFR 47 part1 1.1310 - Radio frequency radiation exposure limits.
- FCC CFR 47 part2 2.1093 - Radio frequency radiation exposure evaluation: portable devices
- FCC KDB 447498 D01 General RF Exposure Guidance v06 - Mobile and Portable Device, RF Exposure, Equipment Authorization Procedures.
1.5. DESCRIPTION OF TEST FACILITY
Test Lab: Aibo Standard Technology (Shenzhen) Co., Ltd.
Address: 101, Building B, Tuori New Energy Industrial Park, High-tech Park, Tianliao Community, Yutang Street, Guangming District, Shenzhen City, Guangdong Province, China
Tel: +(86) 0755 85250797
E-mail: Aibonorm@aibonorm.com
Website: www.Aibonorm.com
The test facility is recognized, certified, or accredited by the following organizations:
- A2LA-Lab Certificate No.: 7514.01
- Aibo Standard Technology (Shenzhen) Co., Ltd. has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing.
- FCC Accredited Lab.
- Designation Number: CN1411
- Test Firm Registration Number: 567066
- ISED Wireless Device Testing Laboratories
- CAB identifier: CN0185
2. RF EXPOSURE EVALUATION
2.1 Limit
According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: "Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 "
The formula for SAR test exclusion is:
[(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] ∙ [f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where:
- f (GHz) is the RF channel transmit frequency in GHz
- Power and distance are rounded to the nearest mW and mm before calculation
- The result is rounded to one decimal place for comparison
- 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.
2.2 Evaluation Result
Band/ Mode | f (GHz) | Evaluation Distance (mm) | RF Output Power (dBm) | Tolerance (dBm) | Max Tune-up | Calc. thresholds | SAR Test Exclusion Threshold | |
---|---|---|---|---|---|---|---|---|
Power(dBm) | Power(mW) | |||||||
BLE | 2440 | 5 | 3.04 | 3(±1) | 4 | 2.51 | 0.7847384 | 3.0 |
Mode | Frequency (MHz) | Power (dBuV/m) | Power (dBm) | Power (mW) | Calc. thresholds | SAR Test Exclusion Threshold |
---|---|---|---|---|---|---|
2.4G | 2438 | 85.91 | -9.29 | 0.117760597 | 0.0367745 | 3.0 |
Notes: 86.91dBuV/m-95.2=-9.29dBm
2.3 Conclusion
The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 D01 v06. No SAR test is required.