Instruction Manual for V-TAC models including: VT-8618S, VT-8624S, VT-8630S, VT-8618S LED Sensor Dome Light, VT-8618S, LED Sensor Dome Light, Sensor Dome Light, Dome Light, Light
V-Tac 18W LED sensorlampe - Samsung LED chip, Mikrobølgesensor, IP20 innendørs, 230V, inkl. lyskilde
V-Tac 18W LED sensorarmatur - Samsung LED chip, Mikrovågssensor, IP20 inomhus, 230V, inkl. ljuskälla
V-Tac 18W LED sensorlampe med Samsung LED chip og mikrobølge sensor ‒ WATTOO.DK
File Info : application/pdf, 1 Pages, 1.91MB
DocumentDocumentINSTRUCTION MANUAL LED SENSOR DOME LIGHT TECHNICAL DATA MODEL SKU WATTS LUMENS BEAM ANGLE BODY TYPE CRI LIFE SPAN 76591-24 76601-24 VT-8618S 76611-24 76691-24 18W 76721-24 76661-24 1830LM Sphere 360° PP+PMMA >80 20,000 Hours VT-8624S 76621-24 76631-24 76641-24 76701-24 24W 2500LM Sphere 360° PP+PMMA >80 20,000 Hours ON/OFF TOTAL CYCLE CURRENT >15,000 130mA >15,000 170mA SPHERE 360° STAYS BRIGHT INPUT VOLTAGE SHAPE DIMENSION (LxWxH) AC:220-240 50/60Hz ROUND SQUARE 295 x 60 mm 295x295x65mm AC:220-240 50/60Hz ROUND 350 x 61 mm VT-8630S 76651-24 76681-24 76711-24 76741-24 36W 3820LM Sphere 360° PP+PMMA >80 20,000 Hours >15,000 160mA AC:220-240 50/60Hz ROUND SQUARE 420 x 65 mm 420x420x65mm SENSOR TECHNICAL DATA DIMENSION INPUT POWER 20mm*20mm*2.6mm DC: 5V STANDBY POWER 5V @ < 30mA WORKING FREQUENCY OF RADAR MODULE 5.8GHz + 5.87GHz INSTALLATION HEIGHT 3m DETECTION RADIUS 1-5m INITIALIZATION TIME 3 sec HOLDUP TIME Adjustable WORKING TEMPERATURE -20°C ~ 85°C AMBIENT LIGHT THRESHOLD Adjustable 'This product contains a light source of energy efficiency class <F>', where <F> shall be replaced by the energy efficiency class of the contained light source. INTRODUCTION & WARRANTY Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 2 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours Daily operation. Usage of product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only. IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS. V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B WARNING · Please make sure to turn off the power before starting the installation. · Installation must be performed by a certified person. · The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced. · For Indoor use only · If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard. · Method of attachment of the cable or cord such that any replacement can only be made by the manufacturer, his service agent or similar qualifed person. This marking indicates that this product should not be disposed of with other household wastes. Caution, risk of electric shock. LED LED Replaceable (LED Only) light source by a professional MULTI-LANGUAGE MANUAL QR CODE Please scan the QR code to access the manual in multiple languages ATTENTION! Do not look directly at LED light beam. Product can only be supplied by rated voltage or voltage within the range provided. It's forbidden to use the product with damaged protective cover. Product must not be used in unfavorable conditions, e.g. dust, water, moisture, vibrations, explosive air atmosphere, fumes, or chemical fumes, etc. In the area of strong electromagnetic interference, the functioning of the product may be disrupted. USAGE GUIDELINES / MAINTENANCE Any maintenance work must be performed when the power supply is cut off and the product has cooled down. Clean only with so and dry cloths. Do not use chemical detergents. Do not cover the product. Ensure free air access. Product may heat up to a higher temperature. MOUNTING Read the manual before mounting. Mounting should be performed by a qualified electrician. Exercise caution. Product has a protective contact /terminal. Failure to connect the protective lead may lead to electric shock. Mounting diagram: see pictures. Check for proper mechanical fastening and connection to electrical power prior to first use. INSTALLATION INSTRUCTION · Switch Off the Power Before Starting the Installation. · Twist and remove the cover · Drill a hole in the ceiling to fix the light using screws (Ref Image Part 2) · Connect the wires (Ref Image Part 3) before fixing the light using screws on the ceiling. · Twist and lock the cover to the light (Ref Image Part 4) · Switch ON the power and test the light. INSTALLATION DIAGRAM DISASSEMBLY DIAGRAM (For Market surveillance team only) SQUARE DOME LIGHT ROUND DOME LIGHT Note: Light source removal will void the warranty REMOTE CONTROLLER INSTRUCTIONS OFF (WITH MEMORY FUNCTION,SENSOR FUNCTION OFF) ON (MICROWAVE FUNCTION OFF,THE LIGHT REMAINS ON CONTINUOUSLY) REPEATED FLASHING MODE: TURN ON THE LIGHT FOR 500MS, THEN TURN OFF THE LIGHT FOR 500MS, AND KEEP REPEATING THIS STATE AUTOMATIC MODE: 100% SENSING DISTANCE, TURN OFF PHOTOSENSITIVE FUNCTION, HOLD TIME FOR 30 SECONDS SENSOR HOLD TIME: 10S, 30S, 5MIN, 10MIN, 20MIN, 30MIN N/A SET THE SENSING DISTANCE LEVEL TO THE LOWEST: INSTALLATION HEIGHT OF 3M, SENSING RADIUS OF 1-2M ADJUST THE SENSING DISTANCE LEVEL TO MEDIUM: INSTALLATION HEIGHT OF 3M, SENSING RADIUS OF 2-3M ADJUST THE SENSING DISTANCE LEVEL TO HIGHEST: INSTALLATION HEIGHT OF 3M, SENSING RADIUS OF 4-5M TURN OFF PHOTOSENSITIVE FUNCTION ADJUST THE PHOTOSENSITIVE THRESHOLD TO 30LUX ADJUST THE PHOTOSENSITIVE THRESHOLD TO 200LUX ADJUST THE PHOTOSENSITIVE THRESHOLD TO 100LUX ADJUST THE PHOTOSENSITIVE THRESHOLD TO 5LUX NOTE: IN ANY SITUATION WITHOUT MICROWAVE FUNCTION, ALL OTHER BUTTONS CAN TURN ON THE MICROWAVE FUNCTION, EXCEPT FOR OFF, ON, TEST THESE THREE BUTTONS. SENSOR INFORMATION Height 3m 1-5m (Radius) 1-5m (Radius) Height of Installation: 3m SENSOR USAGE 1-5m 1-5m Detection Distance: Max. 10m 1 2 3 4 1. When the ambient light is bright enough, even if a moving object is detected, the lamp will not automatically light up 2. When the ambient light is lower than the preset photosensitive threshold, the light will automatically light up when the sensor detects a moving object 3. When the sensor cannot detect the moving object a er the moving object leaves, it will enter the delay time and keep the light on 4. A er the moving object leaves and a er the preset delay time, the lamp will automatically turn off TEST METHOD Start Up Phase 1. The microwave lamp shall be installed at a height of 3M above the ground to ensure that the front induction antenna is horizontally downward, i.e. in the direction of the ground; 2. Power on; 3. The microwave induction module is connected to the power supply. At this time, the module continuously outputs the high level for self inspection for 4S. A er the self inspection is completed, the module continuously outputs the low level and enters the working state. Intelligent Control Stage: 1. When someone enters the microwave induction coverage range (1-5 meters can be customized), the microwave induction module outputs a high level; 2. If someone is active in the microwave coverage area, the induction module always outputs a high level; 3. When a person leaves the microwave coverage range for 1 minute, the induction module outputs a low level Test precautions and special instructions: 1. During the test (especially when the technician tests the sample, the product must be placed on the table top and the antenna surface must be upward), the person must be at least 1m away from the table top. 2. When the light is off, the radar silence time of 1 second is required to be triggered again; 3. During the test, try to eliminate external interference factors, such as the movement of the machine and people or the movement of the partition wall, and prevent low-frequency resonance, false alarm and misjudgment; 4. The delay time refers to the time interval from the start to the end of the last sensing signal, and the countdown a er the person leaves the sensing area; 5. Traditional products are not suitable for long-distance applications installed in a narrow space 6. The above delay time, distance and photosensitive parameters can be appropriately modified according to customer requirements. Supplementary Note: Warning: If signal output port (IFI / IFQ) is sensitive to ESD (electrostatic damage), contact with high electrostatic area or power area may cause irreversible damage to the radar module Warning: If the lamps have been matched (not limited to brands and models) in the development stage, please do not replace other unmatched equipment (including but not limited to power supply and lamps) during use. If the equipment is replaced without authorization and there is any abnormality, our company will not be responsible. Suggestion: It is recommended to use qualified DC stabilized power supply, i.e. DC stabilized power supply with output voltage, current and ripple coefficient up to standard, otherwise the stability of this product will be affected and some abnormalities may occur, such as false alarm, no induction, circulation and self startup. Matters Needing Attention 1. Avoid installing metal accessories or shells, which will shield the microwave and affect the effect; 2. The antenna surface shall be protected from high current circuit coverage, which may cause interference; 3. The photosensitive position shall be protected from opaque objects, which will change the photosensitive intensity; 4. The recommended installation distance of the sensor is greater than 1.5m.