SubstiTUBE® T8 Connected

Please take the time to read this user instruction. The instruction contains important information and notes regarding the installation and operation.

Important: To operate connected system, LEDVANCE Connected SENSOR is required:

Please visit our website www.ledvance.com/substitube-connected for detailed installation instructions.

SubstiTUBE® T8 Connected is suitable to certain T8 G13 bi-pin base / EM (CCG) / Mains.

Key Information and Symbols

Symbol Meaning Remark
SubstiTUBE® Connected Compatible with EM / Mains
EM Electromagnetic = Conventional Control Gear Go to 1. installation
Mains Remove ballast connect directly on 230V Go to 2. installation
Lamp not suitable for emergency operation EM / Mains
Lamps suitable for 50/60Hz operation EM / Mains
Lamps to be used in dry conditions or in a luminaire that provides protection EM / Mains
Dimming not allowed Only possible with LEDVANCE Connected Sensor
LED replacement starter EM
Lamp not suitable for high frequency operation (ECG) HF

Technical Specifications

Replacement of T8 FL Storage temperature (Ts) Ambient temperature (Ta)
0.6m, 1.2m, 1.5m -20° ... 80°C -20° ... 50°C

Hereby, LEDVANCE GmbH declares that the radio equipment is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: smartplus.ledvance.com/declaration-of-conformity.

Wireless radio used in Zigbee lamps/luminaires/components 2400 – 2483.5 MHz, max. RF output power 9.5dBm.

1. Installations on Electromagnetic ballast

Please ensure that for Electro Magnetic (EM) application existing fluorescent starter is replaced with SubstiTUBE® LED starter (included in each packaging).

Steps:

  1. EM (CCG) Installation:
    1. Remove existing starter.
    2. Insert new SubstiTUBE® LED starter.
    3. Install SubstiTUBE® T8 Connected lamp.
    4. Rotate lamp 90 degrees.

Important Notes for EM Installation:

2. Installations on Mains (without ballast)

Steps:

  1. Cut wires and remove ballast.
  2. Follow below instructions for Mains connection.

Mains Installation:

  1. Installation guide
  2. Connect LED Tube to Mains (L and N).
  3. For single lamp fixtures, connect 1x LED Tube.
  4. For multi-lamp fixtures, connect ≥2x LED Tube.
  5. Rotate lamp 90 degrees.

Warning! The fixture has been modified and can no longer operate the originally specified T8 Fluorescent lamp. Please use only OSRAM SubstiTUBE® LED.

Company Information

LEDVANCE GmbH
Steinerne Furt 62
86167 Augsburg, Germany
www.ledvance.com

LEDVANCE Ltd
Aquila House
22 Delta Crescent, Westbrook, Warrington
WA5 7NR, United Kingdom

Recycling information: Lamps and their accessories are recycled. Dispose of at collection points or recycling centers.

Models: SubstiTUBE T8 Connected EM Mains Ultra Output 24W, SubstiTUBE T8 Connected, SubstiTUBE EM Mains Ultra Output 24W, SubstiTUBE 24W EM Mains Ultra Output T8 Connected, SubstiTUBE

File Info : application/pdf, 4 Pages, 3.03MB

PDF preview unavailable. Download the PDF instead.

asset-13057501 substitube t8 connected

References

Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Macintosh)

Related Documents

Preview LEDVANCE LED TUBE T8 EM Connected P: User Manual and Installation Guide
Comprehensive user manual and installation guide for the LEDVANCE LED TUBE T8 EM Connected P. This document provides essential information on installation, operation, specifications, safety warnings, and compliance for the LED lighting product.
Preview LED Lamps from LEDVANCE: Advancing Light Catalog
Discover the comprehensive range of LED lamps from LEDVANCE, featuring high-quality, energy-efficient, and future-proof lighting solutions for professional and commercial applications. Explore LED tubes, luminaires, and specialized lamps designed to advance lighting technology.
Preview LED Tube T8 EM Ultra Output S Installation and Operation Guide
This document provides installation and operation instructions for the LEDVANCE LED Tube T8 EM Ultra Output S. It covers retrofitting and conversion for luminaires with electromagnetic control gear or direct AC mains connection, along with important safety and usage information.
Preview LED TUBE T8 EM V & EN ULTRA OUTPUT V: Installation and Operation Guide
Detailed installation and operation instructions for the LEDVANCE LED TUBE T8 EM V and T8 EN ULTRA OUTPUT V, providing guidance on retrofitting and conversion for T8 fluorescent lamp replacements.
Preview LED Tube T8 EM Ultra Output S Installation and Operation Guide
Comprehensive guide for the installation and operation of the LEDVANCE LED Tube T8 EM Ultra Output S, covering retrofit and conversion installations, technical specifications, and safety information.
Preview LEDVANCE SubstiTUBE T8 UNIVERSAL LED Tube Installation and Operation Guide
This guide provides essential information and instructions for the installation and operation of the LEDVANCE SubstiTUBE T8 UNIVERSAL LED tube. It details compatibility with electronic control gears (ECGs), installation procedures for different ballast types (HF, EM, Mains), and important operational considerations like temperature limits and light distribution. The guide is available in multiple languages.
Preview SubstiTUBE T8 HF LED Tube: Installation Guide and Specifications
This document provides essential information and instructions for installing and operating the OSRAM SubstiTUBE T8 HF LED tube. It details compatibility requirements with electronic control gear (ECGs), operating temperature limits, and important safety precautions, along with product specifications and multilingual compatibility information.
Preview LEDVANCE LED Tube Conversion Kit: Rewiring Instruction for 1-Lamp Luminaires
A comprehensive guide for rewiring 1-lamp luminaires to operate with LEDVANCE LED TUBE T8 EM, UNIVERSAL, T5 AC, or DULUX LED lamps directly on AC mains. This document provides step-by-step instructions, wiring diagrams, and safety considerations for qualified electricians.