Cleveland SteamCraft® Ultra 3 Stacked
TWO COMPARTMENT, TWIN ELECTRIC STEAM GENERATOR, 8 KW EACH
Models
- (2)21-CET-8
Short Form Specifications
Shall be CLEVELAND, Two compartment, SteamCraft® Ultra 3 Stacked, Floor model steamer, Model (2)21-CET-8. Volts, Phase. easyTimer with 99 minute digital readout - timed/manual modes with selector dial. Heavy duty all stainless steel construction. Rear mounted, insulated steam generator with Remote Probe Type Water Level Controls and Automatic Steam Generator. Blowdown with "Water Jet" drain cleaning feature.
Direct Stacked on UNISTAND25 (P/N 111717) with Mounting Kit (P/N 107166)
Standard Features
- Cooking Capacity for up to three 12″ x 20″ x 21/2" deep Cafeteria Pans per compartment.
- Open Base Style unit features a slender 21" wide space saving design. (see options and accessories for cabinet base)
- Innovative Electric Steam Generator: Twin vertical electric atmospheric steam generators operate independently. Two 8.5 KW Fire Bar Heating Elements per generator. Strong 14 Gauge Stainless Steel Construction. Each generator is fully insulated.
- Easy Access Generator Cleaning Port: Two generator cleaning ports located on the outside top of the unit.
- Instant Steam Standby Mode: Holds generator at steaming temperature. Allows unit to start cooking instantly.
- Durable 14 Gauge Stainless Steel Construction: For cavity, front and steam generator.
- Easytimer with 99 minute Digital Readout in minutes and seconds. Selector Dial with LED Light Descale Indicator. Sure Cook load compensating timer. Manual Constant Steam Mode.
- Exclusive Steam Cooking Distribution System: Exclusive Convection Jets produce a high velocity convection steam without fans. Coved Corner design in cooking compartment distributes heat evenly and is easy to keep clean. Creased top & bottom enhance drainage. Cold Water Condenser for each compartment maintains a dry steam. Fully-insulated cooking compartment for thermal efficiency.
- Removable Stainless Steel Slide Racks for easy cleaning.
- Exclusive "Cool to the Touch" Compartment Door Design: Free floating inner door with reversible door gasket provides an air tight seal. Stainless Steel Slam/Latch Door Latch mechanism for reliability.
- Automatic Generator Drain: Contains a "Water Jet" Spray Rinse Cleaning Cycle to keep drain line clear.
- Left-Hand Door Hinging: Compartment Doors hinged left, controls on the right.
- Exclusive Automatic Remote Probe Type Water Level Control: Separate from the generator for easy access.
- Stainless Steel Adjustable Legs: With level adjustment and rear flanged feet for bolting to floor.
- Available in most voltages, single and three phase.
- Compartment Door Steam Shut Off Switch (SCS)
Options & Accessories
- Right-Hand Door Hinging, Controls on the Left (DHR)
- Cafeteria pans in depths of 1", 21/2", 4" and 6"
- Dissolve® Descale Solution, 6 one gallon container w/quart markings (106174)
- Voltages other than standard.
- Water Filters (FLT0040)
Diagrams and Dimensions
The unit has a front view, right side view, and top view. The front view shows a width of 28.13 inches (714mm) and a depth of 30.00 inches (762mm) for the unit and stand. The right side view shows a width of 29.50 inches (749mm) and a depth of 47.50 inches (1207mm) for the unit and stand. The top view shows a width of 21.00 inches (533mm) and a depth of 18.75 inches (476mm).
Electrical connections require two separate connections, with options for 1-phase and 3-phase power, detailing voltage, watts, and amps for each configuration (e.g., 208V, 6,974W/13,948W total, 18.8A/37.6A total for 1-phase).
Water requirements specify a cold water connection with 35 psi minimum and 60 psi maximum pressure, using two 3/4" NH-F connections for the condenser and steam generator. Water quality requirements include TDS (50-250 ppm), Hardness (50-200 mm), pH (7.0-8.5), Chloride (max 50 ppm), free chlorine (max 0.1 ppm), SiO2 (max 13 ppm), NH2CI (max 0.1 ppm), and Total Alkalinity (50-100 ppm).
Drainage requires a 1½" N.P.T. IPS-M connection, noting that the drain line must be vented and should not use PVC pipe. Clearance requirements are 3" on the right, left, and rear, with an additional 12" on the control side if adjoining equipment is over 30" high for service access.