Uplink Interlogix NX-4 Wiring Programming
Interlogix NX-4
Wiring Uplink's Cellular Communicators and Programming the Panel
CAUTION: · It is advised that an experienced alarm installer programs the panel as further programming may
be required to ensure proper performance and use of the full functionality. · Do not route any wiring over circuit board. · Full panel testing, and signal confirmation, must be completed by the installer. NEW FEATURE: For Uplink 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional. IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.
Wiring the 5530M communicators to Interlogix NX-4
1 of 4

Wiring and Programming Uplink Communicators to Interlogix NX-4
Wiring the 5530M with UDM to Interlogix NX-4 for remote
upload/download

Programming the Interlogix NX-4 Alarm Panel via the Keypad

Enable Contact ID reporting:

LED LEDSs of Ready, Power Steady ON Service LED blinks Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON

Keypad Entry *8 9713 0# 0#
15*1*2*3*4*5*6*#
1#
1*2*3*4*#

Action description To enter programming mode To go to main panel programming menu
To enter phone number menu
15* (to choose phone dialing), followed by your desired phone number (123456 is just an example) each figure is followed by *, # to save and go back
To go to account number menu
Enter the desired account number (1234 is an example), # to save and go back

2 of 4

Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON All Zone LEDs are ON All Zone LEDs are ON All Zone LEDs are ON Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON Ready Led steady ON Service LED blinks, Armed LED steady ON

Wiring and Programming Uplink Communicators to Interlogix NX-4

2#

To go to communication format

13*

To choose Contact ID, * to save

4#

To go to events reported to phone 1

*

To confirm all events reporting and go to next section

*

To confirm all events reporting and go back

23#

To go to feature report section

** 1* Exit, Exit

To go to section 3 of the toggle options menu To enable Open/Close reporting Press "Exit" two times to exit programming mode

Programming the GE Interlogix NX-4 Alarm Panel via the Keypad for remote Upload/Download

Program the Panel for Upload/Download:

Display System ready Enter device address Enter location
Loc#19 Seg#
Enter location Loc#20 Seg# Enter location Loc#21 Seg# Enter location

Keypad Entry *89713

Action Description Enter programming mode.

00#

To go to main edit menu.

19#
8, 4, 8, 0, 0, 0, 0, 0, # 20# 1# 21#
1, 2, 3, 8, # Exit, Exit

Start configuring "Download access code". By default, it is "84800000". Set download access code to its default value. Press # to save and go back. IMORTANT - This code should match the one set in the "DL900" software. To go to "Number of rings to answer" menu. Set number of rings to answer to 1. Press # to save and go back. Go to "Download control" toggle menu. All of these (1,2,3,8) should be OFF in order to disable "AMD" and "Call back". Press "Exit" twice to exit programming mode.

3 of 4

Wiring and Programming Uplink Communicators to Interlogix NX-4
4 of 4

