System Overview
These instructions review how to install Sona suspended fixtures. 4ft and 8ft modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphics below show the components required to install a typical run of Sona suspended fixtures.
IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation.

Sona Endcap Kits · Endcap · Sling cable assembly · #8-32 x 1/2" screws (x2)
Module Lengths
Sona suspended fixtures come in 4ft and 8ft modules. Overall module lengths are shown below. Add 4-15/16" for each sculpted endcap or 7/16" for each flat endcap.
4FT Module w/o endcaps

Sona Joint Kit(s) · Sling cable assembly (X1) · Joiner aligner pair (X1) · #10-24 x 9/16" bolts (x2) · #10-24 nuts (x2) Note: 1 kit required for each in-row joint

Tools Required:
· Medium Phillips Screwdriver
· 3/8" Wrench, 1/4" ratchet with 3/8" socket, or 3/8" GearWrench.

Mount Spacing:
Sona fixture modules are designed for exact on-grid mounting.

8FT Module w/o endcaps
! ATTENTION: Install in accordance with national and local building and electrical codes.

Page 1

1 Arrange boxed fixture on floor in specified mounting location, remove fixtures from boxes. Install all ceiling mounting components and vertical aircraft cables using separate installation instruction for Aircraft Cable Mounting (supplied).

2a Install cable gripper

2b Suspend fixture

3 Power Cord Installation

Diffuser

Power cord
1/2" bushing
1/2" electrical knockout Strain relief

Wire nuts

Insert sling cable gripper into cross plate holes as shown. Pivot the cable gripper up. Repeat at other end of light fixture.* For variable mount option, see page 4, steps 9a to 10.
4a
JOINING FIXTURE

With 2 people, raise the fixture up to the suspension cables and feed through grippers. Set fixture to desired height. Slide diffuser back from cross plate if needed.
4b

NOTE:

Insert supplied 1/2" bushing into 1/2" electrical knockout on wire cover reflector. Crimp supplied strain relief onto power cord insulation (recommend Heyco Tool PN0019(R12)). Ensure power cord does not have excess slack or is too tight. Complete necessary electrical connections (by others) in compliance with local codes. Tuck wires into wiring cavity.
5

NON-POWER

POWER

Wago quick connects (supplied)

Wire nuts (by others)

Orientation of joiners

Joining fixture not yet suspended.

SUSPENDED FIXTURE

JOINING FIXTURE

On joining fixture, break apart joiner pair by twisting them apart. Insert joiner brackets into cross plate (brackets should lock into place). With two people, raise second fixture to ceiling.

At joint, rest joiner aligners in suspended fixture at other end (opposite joint), insert aircraft cable through adjuster

IMPORTANT: Do not attempt to join fixtures on floor. Instead hang one fixture at a time and join modules at ceiling level.

Complete in-row electrical connections.
NON-POWER LOCATIONS: Use supplied quick-wire connectors. Tuck wires into wire cavity.
POWER LOCATIONS: Remove installed quick-wire connectors and complete electrical connections using wire nuts (supplied by others). Tuck wires into wiring cavity.

! ATTENTION: Install in accordance with national and local building and electrical codes.

Page 2

6 Secure joints

7 Level all fixtures / rows

8 Install endcaps

Cross plate tab

Slide fixtures together and secure joint using supplied nut and bolt hardware (requires 3/8" wrench, 1/4" ratchet with 3/8" socket, or 3/8" GearWrench).
Slide diffuser back under tab after securing hardware.

LEVEL HORIZONTALLY: Loosen horizontal leveling screw located on bottom of adjuster and level as required. Tighten screw once mount is in level position.
ADJUST VERTICALLY: Support fixture from below and

Attach endcap to first and last module in each row using supplied hardware.
Slide diffuser back under tab on cross plate after securing hardware.

press down on vertical adjustment pin to make fine height adjustments (review instruction A for details)

IMPROTANT: Do not over-tighten endcap screws. Ledalite recommends tightening screws by hand.

A Aircraft cable adjustment

IMPORTANT: Do not force cable into adjuster. Insert cable into adjuster following the steps below.
1. CUT

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environ-

If required, cut cable ends cleanly prior to inserting into adjuster. Recommended cutters: K.K. Porter cable cutter cat. No. 0690TN or Klein all purpose shears cat. No. 1104.

ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Op-

2. INSERT

eration of this equipment in a residential area is likely to cause harmful

Carefully insert cable into tapered end. Press down on vertical adjustment pin to make fine height adjustments. Trim end, as required, leaving minimum 1" exposed.

interference in which case the user will be required to correct the interference at his own expense.

3. TEST

Once cable is inserted, apply a 25lb point load to each mount bracket to ensure all connections are secure.

! ATTENTION: Install in accordance with national and local building and electrical codes.

Page 3

9a Cable gripper Installation
1. Pendant 2. Push Pin 3. Pendant

9b Cable gripper Installation

Edge facing inside of housing

Push Pin
Insert locking plate on sling cable gripper as shown above. All components are located in the End Cap Kit or Joining Kit.

Locking plate will rest on the ball pendant.

9e Cable gripper Installation

9f Cable gripper Installation

9c Cable gripper Installation

9d Cable gripper Installation
Slot 3 chosen for reference

Slide the sling cable gripper and the locking plate through the opening to the desired slot location.

Align sling cable gripper to the opening of the slot.

9g Cable gripper Installation

10 Cable gripper Installation

Slide sling cable gripper into the opening of the chosen slot. Ensure locking plate is installed under housing flange.

Slide the sling cable gripper to the inside opening. Align the 2nd hole on the locking plate to the adjacent hole where the sling cable gripper is coming out of.

Pull the sling cable gripper upwards. Ensure locking plate is flush to the housing flange. Secure the locking plate with the push pin provided.

Follow steps 9a to 9g to install the other side of the sling cable gripper.

! ATTENTION: Install in accordance with national and local building and electrical codes.

Page 4

Sensor in Rows
Single Sensor Controlling Whole Row 1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures. Note : - A maximum of 8 drivers can be wired to 8 sensors; confirm fixture driver count with factory.
Multiple Sensors Controlling Separates Zones in a Row 2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones. Notes : - A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory. - Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).
Sensor Spacing - For correct operation, sensor should be placed a minimum distance of 8ft apart. - Wireless sensor should be placed no further than 40ft apart for good wireless signal connection.

Important Consideration When Using Sensor in a Row
· For fixtures with wireless sensors (CS, SB or RA options):
DO NOT connect fixture purple and brown (or purple & grey/ pink) control wires to an external dimming switch. Fixture mains wiring should not be connected to a circuit with an external on/off switch.
· For best aesthetic condition, place sensors at ends of row only
so as not to break the continuous lens.
· For better occupancy coverage in longer rows, sensors may be
placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.

! ATTENTION: Install in accordance with national and local building and electrical codes.

Page 5

Occupancy Sensor Coverage:
Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.

Daylight Sensor
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:
· Minimum distance from the window  2ft (0.6m).
· Prevent light reflections from outside entering the sensor (for example sunlight re-
flection on a car hood) as this will lead to incorrect light regulation.
As a guideline the formula 0.72 X H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

The detection area for the movement sensor can be roughly divided into two parts;
· Minor movements (person moving  3ft/s or 0.9m/s). · Major movements (person moving  3ft/s or 0.9m/s).
Photosensor spatial response

! ATTENTION: Install in accordance with national and local building and electrical codes.