Inner Range IR-D-P3E/UK Flexible Range Indoor Detector Installation Instructions
Introduction
This document provides installation instructions for the Inner Range IR-D-P3E and IR-D-P3E-UK flexible range indoor detectors. It covers the 'Advanced Models' and details the installation, settings, checking, and other relevant specifications.
Contents
The document is organized into the following sections:
- Before Installation (Page 2)
- Installation (Pages 4-8)
- Settings (Pages 9-12)
- Checking (Page 13)
- Other (Pages 14-17)
Before Installation
Manufacturer's Statement
Symbols and Meanings:
- Warning Symbol (Triangle with exclamation mark): Indicates that failure to follow instructions or improper handling may cause death or serious injury.
- Caution Symbol (Triangle with exclamation mark): Indicates that failure to follow instructions or improper handling may cause injury and/or property damage.
- Note Symbol: Indicates that special attention is required to the section of this symbol.
- Check Mark Symbol: Indicates a recommendation.
- 'X' Symbol (Nix sign): Indicates a prohibition.
Installation Precautions
Warnings:
- Do not destroy or modify the unit.
- Avoid outdoor installation.
- Do not expose the unit to wetting with water.
- Do not install where detection is through glass.
- Avoid partial or complete obscuration of the detection area.
- Prevent face-to-face or back interference between units.
Cautions:
- For IR-D-P3E only: Maintain a distance of less than 1 meter from the unit.
- Mounting Height: Recommended height is 2.0 to 3.0 meters (6'7" to 9'8"), with 2.4 meters (8') being ideal.
- Follow relevant regulations for installation.
Parts Identification
Components
- Base
- Main unit
- Cover
- Lens
- Sponge
Accessories
- Mounting screws (x2)
- Wall tamper screw (x1)
- PEU **: Plug-in EOL Unit
Options
- IR-D-CW-G3 *: Bracket for wall/ceiling mount with tamper switch
- Mounting screws (x2)
- Joint screws (x3)
- Fixing screws (x2)
* Not certified to EN 50131-2-4
** Not evaluated by UL
Important Note: Do not touch the PIR and MW units.
Anti-masking
The anti-masking feature will trigger an alarm and trouble output if the front of the lens is covered with obstacles for over 20 seconds. The sensitivity can be adjusted via DIP switch settings (refer to section 2-3). Options include 'Low', 'Middle' (default), and 'High'. 'Low' may be less effective with certain materials or colors.
Installation
1-1. Disassemble
- Unlock the cover: Turn the locking screw 180 degrees.
- Open the cover: Gently open the detector cover.
- Remove the terminal block: Pull the two stoppers alternately to detach the terminal block. Note: The terminal block does not need to be removed if it does not interfere with base mounting.
1-2. Wall Mount Without Bracket
Wiring
- Wire through the base: Use wiring knockouts for wall/corner mounting.
- Surface wiring: Route wires through the upper or lower knockouts.
- Hidden wiring: Route wires discreetly.
Breaking Knockouts
Refer to the diagrams for instructions on how to break the knockouts for wiring.
Mounting the Base
- Wall Mount: Use the designated mounting holes.
- Corner Mount: Use the designated mounting holes.
- Tamper Protection: Additional holes are provided for tamper protection. If the device is removed from its mounting position, a brown colored part will remain on the wall, activating the tamper switch.
1-3. Wall Mount With Bracket
Wiring and Mounting
- Punch out 3 knockout guides to create a wiring hole.
- Route wires through the knockout hole. Note: Refer to page 5 for instructions on breaking knockouts.
- Caution: Ensure the mounting surface is even to guarantee proper tamper function.
Joining and Fixing the Base
- Join the base onto the bracket using 3 joint screws.
- Fix the base to the bracket using 2 fixing screws. Additional fixing holes are available for stronger fixation.
- Note: Adjust the detection direction during jointing. A walk test is required.
- Note: 2 fixing screws are required for Grade 2 and higher installations.
1-4. Ceiling Mount With Bracket
Changing Bracket for Ceiling Mounting
- Remove the fixing screw and anchor.
- Rotate the body.
- Insert the anchor and tighten the fixing screw.
Wiring and Mounting on Ceiling
- Punch out 3 knockout guides to create a wiring hole.
- Route wires through the knockout hole. Note: Refer to page 5 for instructions on breaking knockouts.
- Caution: Ensure the mounting surface is even to guarantee proper tamper function.
Joining and Fixing the Base
- Join the base onto the bracket using 3 joint screws.
- Fix the base to the bracket using 2 fixing screws. Additional fixing holes are available for stronger fixation.
- Note: Adjust the detection direction during jointing. A walk test is required.
- Note: 2 fixing screws are required for Grade 2 and higher installations.
Wiring to Terminal Block
- Connect wires to the terminal block: SP (Spare), TR (Trouble), COM (Common), AL (Alarm), TP (Tamper), TP (Tamper), LED (Remote LED).
- Attach the terminal block to the base by inserting its protrusions into the corresponding holes.
Power Cable Length
The power cable length should be limited according to the wire gauge and voltage:
Wire Gauge | 12 V DC | 14 V DC |
---|---|---|
AWG 22 (0.33 mm²) | 270 m (890 ft.) | 590 m (1,940 ft.) |
AWG 20 (0.52 mm²) | 430 m (1,410 ft.) | 940 m (3,080 ft.) |
AWG 18 (0.83 mm²) | 690 m (2,260 ft.) | 1,490 m (4,890 ft.) |
Wiring to Tamper Switch (IR-D-CW-G3)
Follow the diagram to wire to the tamper switch, twisting and swaging the wires.
Settings
2-1. Wide/Narrow Setting
- Remove the main unit: Open the hooked part as indicated by red arrows.
- Change Flip Lens: Replace the lens from 'Wide' to 'Narrow'.
Note: Install the lens ensuring letters on the cover and lens match. Changing the lens automatically switches the internal circuit between Narrow and Wide.
How to Remove/Install Lens
- To remove, get over the rib and pull up the lens. A flat head screwdriver may be used if difficult. Caution: Be careful not to damage the lens.
- To install, push the lens firmly at 3 points in numerical order.
Note: When the lens is set to 'Narrow', MW detection is automatically disabled.
2-3. EOL Settings
Select between using the EOL (End Of Line) resistor socket for the PEU or processing lead wires of resistors.
- [1] PEU: Plug-in End of line resistor Unit: Connect the PEU to the socket. Align triangle marks.
- [2] Processing lead wires of the resistors: Strip wires to 20-22 mm. Push and bend the lead wire so resistors fit in the case.
2-3. DIP Switch Settings
- LED: Switch 1 controls LED activation. 'ON' activates always. 'OFF' allows control via the Remote LED terminal (certified to EN when set to 'OFF').
- PIR Sensitivity: Settings include Low, Middle*, High*, Super High*. (*Certified to EN).
- Anti-masking Sensitivity: Settings include OFF, Low, Middle, High*. (*Certified to EN).
- PIR MW LED: Switch 6 controls PIR and MW LED indications. 'OFF' disables them (IR-D-P3E complies EN50131-2-4 when set to 'OFF').
2-4. Volume Setting
Adjusts Microwave sensitivity with settings for Low, Middle, and High.
2-5. Down Zone ON/OFF
This setting controls the 'Down zone'. It is set to 'OFF' by default. It must be set to 'ON' for Grade 3.
Checking
3-1. Walk Test
- Confirm the LED switch is 'ON' and close the cover.
- Walk within the detection area to check performance via LED indication.
- Return the LED switch to 'OFF' after the walk test, if necessary.
- Lock the cover securely.
Note: Conduct a walk test at least once a year.
Other Information
Specifications
Category | Details |
---|---|
Models | IR-D-P3E / UK |
Installation Method | Passive Infrared and Microwave UL *** |
Coverage | Wide: 15 m (50 ft.) 85°, Narrow: 24 m (80 ft.) 5° (No MW detection at "Narrow" setting) |
Detection Zones | Wide: 80 zones/ Narrow: 20 zones |
Mounting Height | 2.0 to 3.0 m (6'7" to 9'8") |
Alarm Period | 2.0 ± 0.5 s |
Warm-up Period | Approx. 60 s (LED blinks) |
LED Indicator | Switchable ON/OFF. Multiple: Warm-up (Green: Alarm and Masking), Purple: PIR, Yellow: Microwave/Self-test error, Red: Low voltage. |
Power Input | 9.5 to 16 V DC UL * |
Current Draw | 16 mA (normal), 21 mA (max.) at 12 V DC |
Relay Output | Trouble: N.C. 24 V DC 0.1 A max. (Resistive load) Alarm: N.C. 24 V DC 0.1 A max. (Resistive load) Tamper: N.C. 24 V DC 0.1 A max. (Resistive load) (Open when cover removed) |
Remote LED | Terminal: open = OFF, 0 V = ON |
Operation Temperature | -20°C to +45°C (-4°F to +113°F) |
Temperature Compensation | Digital (SMDA) |
Environmental Humidity | 95% max. |
RF Interference | No alarm 10 V/m |
Dimensions | H: 159.1 x W: 62.2 x D: 55.7 mm (H: 6.26" x W: 2.45" x D: 2.19") |
Weight | Approx. 200 g (7.05 oz) |
Mounting | Wall, Corner (Indoor) (with Bracket: Wall, Corner, Ceiling) |
* UL requires power from a UL listed burglar alarm class 2 output power limited supply with min standby power of 4 hrs.
** DIP Switch 1 off: All LEDs off except Warm-up. DIP Switch 6 off: PIR/MW LEDs off.
*** For UL compliance with Microwave enabled, set to high sensitivity. Lower sensitivity may impact range.
Specifications and designs are subject to change without notice. Inner Range is not responsible for damages resulting from intrusion if the unit is part of an incomplete system.
Events and Responses
Event | Triggered By | Output & Remarks |
---|---|---|
Anti-masking detection | Objects close to lens surface over 20 sec. | Alarm and Trouble signals. |
Local self test | Detector's circuit periodically (PIR & MW tested). | Fail; Trouble signal. (Detector inactive for ~10 sec during test). |
Walk test | Conduct annually. | Keep 1m clear of detector and objects. |
Low voltage detection | Voltage drop. | Trouble signal. |
LED Indications
- Warm-up: Multiple, 60 s
- Masking detection: Green, Repeats
- Alarm: 2 s
- PIR detection: 2 s
- MW detection: 2 s
- Self test error: Yellow, Repeats
- Low voltage: Red, repeats
Dimensions
Overall dimensions without bracket: Height: 159.1 mm (6.26"), Width: 62.2 mm (2.45"), Depth: 55.7 mm (2.19").
Dimensions with bracket: Height: 107.1 mm (4.22"), Width: 124.5 mm (4.90").
Detection Area
- Wide Mode: Top view shows a wide arc coverage. Side view shows coverage up to 14m, with a 'Down zone' indicated.
- Narrow Mode: Top and side views show a narrower, more focused coverage up to 24m. MW detection is disabled in this mode. The 'Down zone' can be disabled via switch setting (See 2-5).
Note: The dotted line at 2.4m indicates recommended mounting height.
Angle Adjustment With Bracket
The bracket allows for angle adjustments. The detector cover can be swung up to +5° if it does not reach the ceiling.
Compliance
- RE Directive 2014/53/EU: The IR-D-P3E and IR-D-P3E-UK comply with this directive. Microwave emission frequencies are 10.525 GHz (IR-D-P3E) and 10.587 GHz (IR-D-P3E-UK).
- EU Radiation Exposure Limits: Complies with limits for uncontrolled environments, requiring a minimum 20 cm distance from the radiator to the body.
- UK Radio Equipment Regulations 2017: IR-D-P3E-UK complies with UK regulations and exposure limits.
- FCC/IC: Complies with FCC Part 15 and Innovation, Science and Economic Development Canada's licence-exempt RSS. Users are cautioned against unauthorized modifications.
- EN 50131-1: Security Grade 3, Environmental Class II. Applied Standards: EN 50131-2-4. Tested and certified by Kiwa.