User Manual for Dryflow models including: TFJM, Turboforce Junior MKII Hand Dryer, TFJM Turboforce Junior MKII Hand Dryer
1200MM (47 1/4") 1200MM (39 3/8") It is recommended to avoid installation of dryer near high reflective objects (mirror, stainless steel washbasins, etc.)
1200MM (47 1/4") 1200MM (39 3/8") It is recommended to avoid installation of dryer near high reflective objects (mirror, stainless steel washbasins, etc.)
Intelligenthanddryers.com view install, tips setting › Url: https://www.intelligenthanddryers.com/downloads/1631614989Install and User Manual - Turboforce Junior MKII Hand Dryer (PDF)
File Info : application/pdf, 11 Pages, 2.18MB
DocumentDocumentTurboforce Junior MKII Hand Dryer User Manual Dryflow, 7 Riverside Court, Don Road, Sheffield, S9 2TJ. UK. +44 (0)114 3540047 | info@dryflow.co.uk | www.dryflow.co.uk PLEASE READ CAREFULLY THROUGH THIS MANUAL BEFORE USING THE PRODUCT, OBSERVING ALL SAFETY INFORMATION, WARNINGS. V5 SAFETY WARNINGS Before installing, be sure to read this installation manual and retain for future reference. This product must be installed by qualified personnel in accordance with the instructions given in this manual and installation must comply with all applicable regulations, national security standards and laws in force in the country where the product is installed. Turn off the power at the main switch before installing or servicing the dryer unit The dryer must not be installed on a flammable surface. Do not damage any parts of the electrical connections. Pre-arrange an appropriate power outlet and a system of disconnection in accordance with current local regulations. Make sure the product is properly connected to ground. If there is no ground connection, there is a risk of an electrical shock. Do not install the dryer over a washbasin. If the power cord is damaged, it must be repaired by qualified personnel to avoid any type of risk. This dryer can be used by children aged 8 years and above. People with reduced physical, sensory or mental abilities or lack of experience and knowledge, if they have been given supervision and appropriate training regarding the use of the dryer in a safe manner, can use it with no restriction. Children should not play with the apparatus. Cleaning and maintenance performed by the owner should not be done without children having supervision. During use, temperatures above 158 [70] may develop in the parts near the hot air nozzle. Do not touch or cover the dryer during use or when finished using it. General safety information: WA RWNAI NRGNING This product is intended for installation by a qualified service person. Use AWG NO.12 solid conductor for wiring. WA RDNAI NNGGER Failure to properly ground unit could result in service electrical shock and/or death. WA RWNAI NRGNING Disconnect power at the service breaker before installing or servicing. WA RWNAI NRGNING All units must be supplied with a 3-wire service. The ground wire must be connected to the dryer's backplate. --NOTE: Do not install dryer over washbasin -- PACKING LIST ITEM KEY A B C D E F G ITEM DESCRIPTION Hand Dryer Unit Complete Owner Manual (OM - this booklet) Mounting Template (MT) Wall Anchors, Expansion Self-threading Phillips PH Screws Flat Washer Hex Key (for cover screws) A ITEM QTY 1 1 1 4 4 4 1 NOTES Stainless Steel 304 Cover & Cabinet 8x38MM [ 5/16" Dia.x 1-1/2"], for#10 M5x36MM [ No.10 AB x 1-3/16"] F1 For M5[No.10 AB]Phillips PH Screws For 4MM[ 5/32"] hex socket FH Screws B C D MT E F G 4MM [5/32"] SPECIFICATION Voltage: Stand-by Power: 220V-240V 50/60Hz,6A,1350W Less than 2.0W ONLY to be used on same voltage as product rated label marked. Air Temperature: Air Velocity: Air Flow: Drying Time: Timing Protection: Timing Duration: Sensor Range: Fuse Protection: Protection Level: Electric Isolation: Brush Motor: Noise(at 1M): Weight: 45[113°F](Distance from nozzle=100MM[4"],Room Temp.=25[77°F]) 100M/S[328 FT/S] / 360KM/H[224MPH] 130M3/H[76.5CFM) 10-12 Seconds Forced Hold-On 60 Seconds auto shut-off Auto Shut-Off 3 Seconds after last sensor read 5-15CM[2"~ 5-7/8"], Owner Adjustable Main PCB, 5x20, 250V, 10A[230V] IP23 CLASS 25000RPM, 500W[0.67HP] 70dB 3.5KG[7.7lb]/Net Weight, 4.0KG[8.8lb]/Shipping Weight 173MM 152MM [6-13/16"] [5-63/64"] 256MM[10-5/64"] BEFORE INSTALLATION Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electrician. Hand dryer is to be installed with hardwired stub provided in advance of install by others. See MT for complete reference to mounting heights and power KO locations. 42MM[1-21/32"] 71MM[2-51/64"] L Min. = 300MM[11-13/16"] 220-240V: 6A 98MM [3-55/64"] 91MM[3-37/64"] 1200MM (47 1/4") 1200MM (39 3/8") Recommended It is recommended to avoid installation of dryer near high reflective objects (mirror, stainless steel washbasins, etc.) in order to avoid faulty function of the presence sensor. INSTALLATION 1. Make sure power supply breaker is switched off. Installation must adhere to the regulations of the current edition of the local wiring code having jurisdiction. Installation should be performed only by a qualified electrician. 2. Place template against wall at desired height (see mounting height recommendations on MT) and mark locations of four(4) mounting holes and wire service entry at knockout (KO) location. Note: For two(2) or more dryers units, units should be no closer than 610MM[24"] on centers. 3. Remove and retain 2 cover screws and cover. 4. a. For in-wall (concealed) power supply- Provide supply wire to KO location according to local code and attach securely to chassis at KO with appropriate strain relief connector (not supplied). b. For surface Mounted Conduit (exposed) power supply Provide appropriate conduit to entry location accordingly to local code and attach securely to chassis with correct strain relief connector (not supplied). 5. Drill four(4) holes at location A,B,C, and D of 5/16" Diameter(8) x 35MM[1-3/8"] deep if using wall anchors supplied with unit. Install supplied anchors flush with wall face, or install other fastening system suitable for wall conditions (not supplied). Attach dryer to wall. For wood wall/studs use Dia. M6[1/4"] screws at length that will ensure 25MM [1"] min. stud penetration. For masonry walls use expansion bolts or anchors for Dia.M6[1/4"] screws to ensure penetration 6MM[1/4"] deeper than anchor. Shim if necessary to ensure base plate is flat against wall. 6. Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal block where indicated and connect ground wire to base plate with ground screw. Connections: A. Connect the live wire(colored Brown, Red, or Black) to the terminal block marked "L". B. Connect the neutral wire(colored Black, Blue, White or Grey) or connect the second live wire(colored Red or Orange) to the terminal block marked "N". C. Connect the ground wire to the terminal block marked " " or to the green screw marked " "Bare grounding (earth) wires should be sleeved with green and yellow or green tubing. Colors of live and neutral wires depends on voltage of supply service and requirements of Building and Electrical Code having jurisdiction. 7. Replace cover. Do not over-tighten screws. Circuit Breaker (By others) Dia.8[5/16"] 4MM [5/32"] HARD WIRED ONLY HOT AIR ON/OFF (Selection) SENSOR RANGE SETTING Turn CCW Turn CW Sensor VR TURN ON CIRCUIT BREAKER 4MM [5/32"] OPERATION No-touch operation. There is a blue LED light to guide user to the air flow. Shake excess water from hands. Place hands under the outlet to start operation. Rub hands lightly and rapidly under the nozzle outlet. Stops automatically after hands are removed or if maximum time is reached. BASIC USE Operation without touching, place your hands under the exit to activate the device. OWNER ADJUSTMENTS Externally visible service blue LED light guides hands to air flow. After 3 seconds without detecting hands, the device stops automatically. It is possible to turn on/off hot air with a switch (Selection) located inside the unit chassis (See 7 in "INSTALLATION"). It is possible to adjust the sensor range by means of the sensor VR located on program PCB (See section 8 in "INSTALLATION"). DIAGNOSTICS & REMEDIES Hand dryer fails to start Hand dryer turns on/off erratically or not sensitive enough Ensure the breaker supplying the dryer is operational. If it is, disconnect the power and remove the hand dryer cover. Check all the wire connection to sure they are well fixed. Turn on power and verify correct power at terminal block. If it does not work then replace circuit board. Ensure that there is no obstruction on or in front of the infrared sensor zone. Clean any dirt off the sensor lens. Try adjusting the sensitivity potentiometer on program board. If it still does not work, replace circuit board and sensor board. Not hot air Hand dryer makes ticking noise Check if the heat element switch is set for power on. Check if the heat element is broken. If yes, replace with a new one. Check the motor brush wear down condition. Replace them if worn out or install a new motor. Disconnect power, remove cover, check to make sure no object is stuck in motor vents. WARRANTY All of our dryers are designed and manufactured to provide years of dependable performance. Component parts are guaranteed to be free of defects in material and workmanship for a period of one (1) year from date of original invoice. This guarantee will be honored provided that the dryer is installed and maintained in accordance with the instructions. Parts damaged during the installation are the purchaser's responsibility. The warranty covers defects exclusively, and only liability for the replacement of defective parts will be accepted. This warranty does not cover wear and tear, or misuse and abuse. Defective parts must be returned, accompanied by the serial number, to the point of purchase. This warranty is granted solely to the original purchaser of the unit and is subject to registration. Periodic cleaning of the unit is recommended. Remove cover and clean dryer dust lint. Stainless steel is highly resistant to rust, but there are some very strict cleaning and maintenance rules to be followed to prevent damage to its appearance. Apply neutral detergents formulated for these purposes (non-ionic surfactants and citric acid). Apply the detergent with soft cloth. Be careful with abrasive cloths. They may scratch the surface. Rinse with water until all the detergent has gone. Residue from hygiene products, liquid soap, shampoos, bath gel, etc, can also damage surfaces. Rinse the surface with plenty of water after use. Limescale stains can be prevented by drying the surface with a soft cloth after use. Limescale from mains water: Apply a solution of one part vinegar and three parts water directly to the stains and leave to work for a few minutes. Then rub with a soft cloth or damp sponge. Then give it a final wash with plenty of water and neutral soap to ensure it is thoroughly rinsed. Unacceptable practices (loss of guarantee) - Do not apply detergents with abrasive products or which contain: Hydrochloric acid Sodium hypochlorite (bleach) Formic acid. - Do not use abrasive utensils like metal sourcing pads or abrasive sponges. - Do not spray the detergent on the surface, because the liquid can get into the openings or cracks in them and cause damage. - Do not use anti-limescale and descaling cleaning products. They are not suitable for cleaning stainless steel. - Do not use silver cleaners, contain chlorides that attack stainless steel. Bleach and descalers are often applied to bathroom equipment and left to work for a time. This leads to the release of gases that contain chloride, which together with the water in the surface cause chlorides to run down the surface of the stainless steel. This rusts both internal and external surfaces. DIAGRAM BY STANDARD CIRCUIT BOARD Sensor Assembly See owner adjustments Main Fuse Program Board Assembly Power Main Board Assembly Motor Heating These two connectors are interchangeable Power Motor Heating LED Light Assembly [ Selection ] Black Power (Hardwired). ONLY be used on same voltage as product rated label marked. Heat Element Grounding Yellow Black HOT/COLD Switch [ Selection ] Terminal Block Blue Brown Motor Compact design for any size washroom