Blauberg Auto Fan User's Manual

BLAUBERG Company is happy to offer your attention a new generation product, the BLAUBERG Auto fan. The solid team of high-qualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class.

Introduction

The present service instruction contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan BLAUBERG Auto.

Use

The BLAUBERG Auto fan is designed for exhaust ventilation of residential and public premises heated during winter season. The fan is designed for wall or ceiling mounting (fig. 3-5). The fan is equipped with automatic shutters to prevent air back drafting during the fan standby.

Complete Set

The fan design is regularly improved, so some models can slightly differ from those ones described in this service instruction.

Basic Characteristics

The fan designations, parameters, outer view, overall and connecting dimensions are shown in tables 1, 2, 3 and in fig. 1 and 2.

Table 1

Model Max. air flow [m³/h] Power [W] RPM [min⁻¹] Noise level, 3 m [dBA]
Auto 100 98 18 2300 34
Auto 125 185 22 2400 35
Auto 150 295 26 2400 39

Table 2

Model Switch Timer Humidity sensor Motion sensor
Auto
Auto S
Auto T
Auto ST
Auto H
Auto SH
Auto IR

Switch (S) - built-in pull cord switch;

Timer (T) - turn-off time range from 2 to 30 min;

Humidity sensor (H) - humidity level range from 60% to 90%;

Motion sensor (IR) - reach distance from 1 to 4 m and sensor viewing angle up to 100°.

The fan does not cause interference with radio-, TV- or video-equipment.

Service life is not less than 5 years.

Figure 1: Fan Components

1 - cover; 2 - casing; 3 - motor; 4 - impeller.

[Diagram showing the disassembled parts of the fan with labels 1, 2, 3, and 4]

Table 3: Dimensions and Weight

Model Dimensions [mm] Weight [kg]
a b1 b2 b3 c d e
Auto 100 166 150 150 150 90 100 30 0,56
Auto 125 186 128 173 174 98 125 33 0,73
Auto 150 210 150 195 196 115 150 34 0,9

Figure 2: Fan Dimensions

[Diagram showing the front and side views of the fan with dimensions labeled a, b1, b2, b3, c, d, and e]

Operation Rules

The fan is rated for connection to 220...240 V / 50 Hz power mains and is designed for continuous operation always connected to power mains. The air motion direction in the system must match the pointer on the fan casing. The fan is rated for operation at ambient temperature from +1 °C up to +45 °C. The unit is rated as a Class II electrical appliance.

Safety Rules

All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. The single-phase power grid must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic switch that is used for connection of the fan to power mains with gap on all poles at least 3 mm.

Make sure the impeller and the casing are not damaged before starting installation. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the product or any unauthorized modification are not allowed.

The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the product. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. The maximum permitted pressure difference per living units is 4 Pa. Operating medium must not contain any dust or other solid impurities, sticky substances or fibrous materials. The fan is not rated for operation in a media that contains hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or exhaust vent not to disturb the natural air passage. Do not sit on the fan and do not put objects on the fan. Follow the guidelines of this service instructions to ensure durable operation of the product.

Mounting and Setup

The fan is designed for ceiling or wall mounting to extract air into a ventilation shaft or matching air duct of respective diameter (fig. 3-7). The fan mounting sequence is shown in fig. 8-9. The fan wiring diagrams are shown in fig. 10-16.

[Diagrams showing various mounting and setup configurations of the fan]

Wiring Diagrams and Fan Operating Logic

Figure 10: Auto Fan Wiring and Logic

[Diagram showing wiring for the basic Auto fan model and a flowchart illustrating its operation: Fan does not run -> Switch is closed -> Fan runs -> Switch is opened]

S - external switch

QF - automatic circuit breaker

Figure 11: Auto S Fan Wiring and Logic

[Diagram showing wiring for the Auto S fan model with a pull cord switch and a flowchart illustrating its operation: Fan does not run -> Pull the cord switch -> Fan runs -> Pull the cord switch]

QF - automatic circuit breaker

Figure 12: Auto T Fan Wiring and Logic

[Diagram showing wiring for the Auto T fan model with a timer and a flowchart illustrating its operation: Fan does not run -> Switch is closed -> Fan runs -> Switch is opened -> Turn-off delay timer starts (2 to 30 min)]

S - external switch

QF - automatic circuit breaker

Figure 13: Auto ST Fan Wiring and Logic

[Diagram showing wiring for the Auto ST fan model with a pull cord switch and timer, and a flowchart illustrating its operation: Fan does not run -> Pull the cord switch -> Fan runs -> Pull the cord switch -> Turn-off delay timer starts (2 to 30 min)]

QF - automatic circuit breaker

Figure 14: Auto H Fan Wiring and Logic

[Diagram showing wiring for the Auto H fan model with humidity sensor and timer, and a flowchart illustrating its operation based on humidity levels and switch status]

S - external switch

QF - automatic circuit breaker

Figure 15: Auto SH Fan Wiring and Logic

[Diagram showing wiring for the Auto SH fan model with pull cord switch, humidity sensor, and timer, and a flowchart illustrating its operation based on humidity levels and switch status]

QF - automatic circuit breaker

Figure 16: Auto IR Fan Wiring and Logic

[Diagram showing wiring for the Auto IR fan model with motion sensor and timer, and a flowchart illustrating its operation: Fan does not run -> Motion is detected -> Fun runs -> No motion detected -> Turn-off delay timer starts (2 to 30 min)]

QF - automatic circuit breaker

Warning and Adjustments

Warning! The timer circuit is under mains voltage! Disconnect the fan from power mains prior to any adjustment operations. The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. Use the screwdriver to alter the turn-off delay time threshold.

Do not use a screwdriver, knife, etc. for adjustment operations not to damage the circuit board.

[Diagram showing adjustment controls for timer and humidity sensor]

Maintenance

Any servicing and maintenance operations of the fan are allowed after it is disconnected from power mains only. Maintenance means regular cleaning of the fan surfaces from dirt and dust. To clean the fan, wipe its surfaces with a cloth wetted in a mild soap solution, then wipe the surfaces dry. Avoid water dripping on the motor and circuit board!

Storage and Transportation Rules

The unit can be carried in the original packing by any mode of transport provided proper protection against precipitation and mechanical damage.

Store the unit in the manufacturer's original packaging box in a dry closed ventilated premise with temperature range from +5 °C to +40 °C and relative humidity up to 80%. The storage environment must be free of dust, acid or alkali vapours to prevent corrosion.

[Icon of a trash can with a cross over it, indicating separate disposal]

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE IT AS UNSORTED DOMESTIC WASTE.

Manufacturer's Warranty

The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility.

We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council and Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Assessment of compliance of the product with the requirements relating to electromagnetic compatibility was based on the following standards. Protection degree index according to IP rating against access to hazardous parts and water ingress - IP24.

The manufacturer hereby warrants normal operation of the fan over the period of five years from the retail sale date provided observance of the installation and operation regulations. In case of failure due to faulty equipment during the warranty period the consumer has the right to exchange it.

Warning! To replace the unit, the user must provide the user's manual with the purchase date stamp and the payment paperwork certifying the purchase. In case of no confirmation of the sale date, the warranty period shall be calculated from the manufacturing date.

By purchasing this product the customer confirms to have read and agreed to the terms, rules and requirements related to operation, storage, transportation, mounting, adjustment, connection, maintenance and repair as well as warranty obligations with respect to this product as set forth in the manufacturer's accompanying documentation to the product.

Models: Auto, 150 Wall Exhaust Fan, Wall Exhaust Fan, 150 Exhaust Fan, Exhaust Fan, Fan

File Info : application/pdf, 16 Pages, 1.87MB

auto en a6 03 preview Corel PDF Engine Version 17.0.0.491 CorelDRAW X7

Related Documents

Preview BLAUBERG Quatro Axial Fan User Manual and Installation Guide
Comprehensive user manual and installation guide for the BLAUBERG Quatro axial fan series, covering specifications, setup, operation, maintenance, and warranty information.
Preview BLAUBERG Centro-MZ Inline Centrifugal Fans - Technical Specifications and Data
Detailed technical specifications, performance data, and features for the BLAUBERG Centro-MZ series of inline centrifugal fans, designed for efficient industrial and commercial ventilation systems.
Preview Blauberg Centro-MZ EC Inline Centrifugal Fans | Technical Specifications and Performance Data
Detailed technical specifications, dimensions, performance curves, and accessory information for the Blauberg Centro-MZ EC series of inline centrifugal fans, designed for efficient industrial ventilation applications.
Preview Blauberg Turbo Inline Mixed-Flow Fans: Technical Specifications and Features
Explore the Blauberg Turbo series of inline mixed-flow fans. This document details technical specifications, dimensions, performance data, and features for models Turbo 100 through Turbo 315, designed for efficient ventilation in industrial and commercial applications.
Preview BLAUBERG Sileo Axial Fan User Manual - Installation, Operation, and Maintenance
Comprehensive user manual for BLAUBERG Sileo and Sileo Design axial fans. Includes delivery set, technical specifications, installation guide, operation setup, maintenance, troubleshooting, and warranty information.
Preview Blauberg Omega & Omega One Axial Fan User Manual
Comprehensive user manual for Blauberg Omega and Omega One axial fans, detailing installation, operation, electronic system algorithms, maintenance, troubleshooting, and manufacturer's warranty information.
Preview BLAUBERG Jet 100 Series Fan - User Manual and Technical Specifications
Comprehensive user manual and technical guide for the BLAUBERG Jet 100, Jet 100 T, and Jet 100 H exhaust fans. Includes installation, operation, safety, and warranty information.
Preview BLAUBERG Quatro Axial Fan User Manual: Installation, Operation, and Maintenance
This user manual provides detailed information on the BLAUBERG Quatro axial fan series, including delivery set, brief description, operation guidelines, designation key, installation and setup, electronics operation algorithm, fan setup, technical maintenance, storage and transportation regulations, and manufacturer's warranty.