Key Features
- DSP Control
- 1.0 Output Power Factor (PF)
- Wide Input Range 110-275VAC (depending on load)
- Configurable Battery quantity 16 to 20 pcs per string without power derating
- Battery capacity calculation
- Event log via LCD
- No power derating in full operating temperature range
- High Efficiency Inverter mode @95%
- Input THDI < 3%
- Output THDv < 5%
- Frequency Converter Mode
- Variety of Communication Ports: RS232, USB, EPO, Dry In (for remote action), Dry out (for UPS status)
- Maintenance bypass switch
- 3 hours recharging to 90% of battery capacity
- Charger current is adjustable, 1A to 12A through LCD
- N + X Parallel Redundancy
- Over Voltage Cut-Off device (OVCD) for Tough environment
- Emergency Power Off (EPO)
- Short Circuit Clearance with current limit
- Optional SNMP, Relay Cards & MODBUS
- Free Power Management Software for Standalone LAN & WAN
Product Description
The Titan Elite Gen.2 series is built for the most reliability, purity, and power. This UPS is feature-rich, utilizing unique True Online Double Conversion circuitry to detect electricity current and voltage output of the utility power supply. The current is input via high-frequency PWM to maintain a uniform waveform and phase in line with the voltage, achieving a high input power factor over 0.995 and avoiding significant harmonic interference on the power network. With the use of outstanding IGBTs as the power conversion component, it achieves full performance output capacity at PF 1.0. Higher working efficiency of the inverter also improves the overall efficiency of the UPS up to 95%, and a higher inversion frequency reduces the noise of the inverter.
Product Information
Category | Parameter | TE-6k | TE-6kS | TE-10k | TE-10kS |
---|---|---|---|---|---|
INPUT | Voltage Range | 110-275 VAC | |||
Frequency Range | 45-55Hz/54-66Hz (extendable to 40-70Hz when load <60%) | ||||
Phase | Single phase with ground | ||||
Current THDI | <3% | ||||
Power Factor | >=0.995 | ||||
Generator Input | 1.5 x UPS Rating Power | ||||
OUTPUT | Voltage Range | 220VAC/230VAC/240VAC (± 1%) | |||
Phase | Single phase with ground | ||||
Frequency (Synchronized Range) | 45-55Hz/54-66Hz (extendable to 40-70Hz when load <60%) | ||||
Frequency (Battery Mode) | 50/60Hz ± 0.01Hz | ||||
Current Crest Ratio | 3:1 | ||||
Harmonic Distortion | < 1% THD @Linear Load, <5% @non-linear load | ||||
EFFICIENCY | Protection | Short Circuit Protection | |||
Output Waveform | Pure Sinewave | ||||
Outlet | Terminal Block | ||||
BATTERY | Overload Line Mode | 10 min @ 105%~125%; 30 sec @ 125%~150%; 500 msec @ > 150% | |||
Capacity Battery Mode | 1 min @ 105%~125%; 30 sec @ 125%~150%; 500 msec @ > 150% | ||||
AC Mode / Battery Mode Efficiency | > 95% / >95 % | ||||
ECO mode Efficiency | > 98% | ||||
BATTERY | Number of Batteries Per Set | 16/17/18/19/20 | |||
Battery Capacity (Ahr) | 12V/(7/9)Ahr | ||||
Backup Time (depend on load) | >15 min | ||||
Recharge Time (to 90%) | 3 Hours | ||||
Charge Current Adjustable | default 1A(0-4A) default 4.0A (0-12A) | ||||
Rated Battery Voltage | 192-240 Vdc (adjustable) | ||||
Battery Type | Sealed Lead Acid Maintenance Free | ||||
TRANSFER TIME AC to DC | Zero | ||||
TRANSFER TIME | Parallel N+X Parallel Redundancy | Max 3 (Load Sharing) | |||
LED & LCD display | LED: Online mode, Battery mode, Bypass/Standby mode, Fault. LCD: Input/Output Voltage&Frequency, Load level, Load Watt, Load VA, Battery Voltage, Battery status, Converter mode, Battery Remaining Time, Battery running Time, UPS status, Fault indicator, Event Log, etc. | ||||
AUDIBLE ALARM | Battery Mode | Sounding every 4 seconds | |||
Low Battery | Sounding every second | ||||
Overload | Sounding twice every second | ||||
Fault | Continuously Sounding | ||||
DIMENSION | W x H x D mm | 220 x 589 x 492 | 220 x 348 x 492 | 220 x 589 x 492 | 220 x 348 x 492 |
kg | 52.7 | 13 ex.bat | 60.3 | 15.2 ex.bat | |
ENVIRONMENT | Operating Environment | 0-40° C | |||
Relative Humidity | 0-95% (NON-CONDENSING) | ||||
Noise Level | <45dB @ 1 Meter | ||||
INTERFACE | USB & RS-232 | Software supports Windows Family, Linux, Sun Solaris, IBM AIX, Compaq True64, SGI IRIX, FressBSD, HP-UX and MAC | |||
Smart Slot (Option) | SNMP Adapter/ AS400 Relay Card / RS485 / USB | ||||
INTERNATIONAL STANDARDS | CE | Safety (IEC62040-1-1), EMC: IEC/EN 62040-2, IEC 61000-4-2(ESD):level 3, IEC 61000-4-3 (Radiated field): level 3, IEC 61000-4-4(EFT): level 4, IEC61000-4-5 (Fast transients): level 4, IEC 61999-4-6 (Electromagnetic field): level 3, IEC 61000-4-8 (Conducted magnetic field): level 4, Performance: IEC/EN 62040-3 |