TaqPath COVID-19, Flu A/B, RSV Combo Kit

Lab Readiness Checklist

A single test to detect and differentiate SARS-CoV-2, influenza A/B, and respiratory syncytial virus (RSV) A/B

Applied Biosystems™ TaqPath™ COVID-19, Flu A/B, RSV Combo Kit (Cat. No. A49867)

For use with:

This document lists all instruments, consumables, and reagents recommended and required for installing the instrument, training, and running an experiment for the detection of RNA from SARS-CoV-2, Flu A/B, and RSV. Please review this list carefully to ensure all necessary materials are available before installation and training dates. Missing materials can delay your setup process. Intended uses of the products mentioned vary. For specific intended use statements, please refer to the product label.

Note: To avoid contamination, it is highly recommended that you have separate sets of pipettes for samples and extraction, PCR reaction setup, and any post-PCR processing. Ideally these steps should all be performed in separate laboratory spaces as well. Always follow necessary precautions when handling patient samples.

Ordering Information

TaqPath COVID-19, Flu A/B, RSV Combo Kit

ProductSupplierStorageCat. No.
TaqPath COVID-19, Flu A/B, RSV Combo KitThermo Fisher ScientificDetails belowA49867
Includes:
TaqPath RT-PCR COVID-19, Flu A/B, RSV Kit
• Multiplex assay targeting the SARS-CoV-2 S and N genes, influenza A/B matrix gene, RSV A/B, N gene/M gene, and bacteriophage MS2
• MS2 phage control
TaqPath COVID-19, Flu A/B, RSV Control
• COVID-19, Flu A/B, RSV Controls
TaqPath Control Dilution Buffer
TaqPath 1-Step Multiplex Master Mix, No ROX
Thermo Fisher Scientific-30°C to -10°C
Below -70°C
-30°C to -10°C
-30°C to -10°C

Required materials not supplied

Real-time PCR

Ordering Information

Data analysis and reporting software
ProductSupplierStorageCat. No.
Pathogen Interpretive Software CE-IVD Edition v1.0.1 and SAE Administrator Console Dx
Compatible with:
• 7500 Fast Real-Time PCR Instrument (used with SDS Software v1.5.1 or 7500 Software v2.3)
Thermo Fisher ScientificN/AContact us at 800-955-6288, option 3, option 1; or email at instrumentservices@thermofisher.com
Separate computer for the Pathogen Interpretive Software with at least 4 GB of RAM, at least 60 GB of available disk space, and one of the following operating systems:
• Windows 10 (Professional), 64-bit
• Windows 10 (Enterprise), 64-bit
• Windows 7 (Professional), Service Pack 1, 64-bit
VariousN/AVarious
Real-time PCR instrument
ProductSupplierStorageCat. No.
7500 Fast Real-Time PCR Instrument (used with SDS Software v1.5.1 or 7500 Software v2.3)Thermo Fisher ScientificRT4351106 (with laptop computer)
4351107 (with desktop computer)
Calibration plates (7500 Fast Real-Time PCR Instrument)
ProductSupplierStorageCat. No.
ABY Dye Spectral Calibration Plate for Multiplex qPCR, Fast 96-well, 0.1 mLThermo Fisher Scientific-20°CA24734
JUN Dye Spectral Calibration Plate for Multiplex qPCR, Fast 96-well, 0.1 mLThermo Fisher Scientific-20°CA24735
7500 Fast Real-Time PCR Systems Spectral Calibration Kit I, 0.1 mL (contains background plate, region of interest (ROI) and calibration plates for FAM, JOE, NED, ROX, SYBR Green, TAMRA, and VIC dyes)Thermo Fisher Scientific-20°C4360788 (if recalibration is required)

Nucleic acid extraction

Ordering Information

Kits and reagents
ProductSupplierStorageCat. No.
MagMAX Viral/Pathogen II Nucleic Acid Isolation KitThermo Fisher ScientificRTRecommended: A48383
Ethanol, absolute (200 proof), ACS reagent-grade or equivalentFisher ScientificRTRecommended: BP2818100, BP2818500, BP28184
Nuclease-Free Water (not DEPC-treated) or equivalentThermo Fisher Scientific or Fisher ScientificRTRecommended: AM9932 or BP2819-100, BP2819-1, BP2819-4, BP2819-10, BP2819-20
Automated processing tools
ProductSupplierStorageCat. No.
KingFisher Flex Purification System with 96 Deep-Well Head and Deep-Well Heating BlockThermo Fisher ScientificRT5400630
KingFisher Flex 96 Deep-Well Heating Block (if currently using standard block)*Thermo Fisher ScientificRT24075430
KingFisher 96 Tip Comb for Deep-Well MagnetsThermo Fisher ScientificRT97002534, A48438, A48414
KingFisher Deep-Well 96 PlateThermo Fisher ScientificRT95040450, A48305, A48424, 95040455
96-Well MicroplateThermo Fisher ScientificRT97002540, AB0796, AB1127, 136101

General laboratory equipment and consumables

Ordering Information

ProductSupplierStorageCat. No.
MicroAmp Fast Optical 96-Well Reaction Plate, 0.1 mLThermo Fisher ScientificRT4346907
MicroAmp Fast Optical 96-Well Reaction Plate with Barcode, 0.1 mLThermo Fisher ScientificRT4346906, 4366932
MicroAmp Optical Adhesive FilmThermo Fisher ScientificRT4360954, 4311971
MicroAmp Adhesive Film ApplicatorThermo Fisher ScientificRT4333183
Sterile Aerosol Barrier (Filtered) Pipette TipsThermo Fisher ScientificRTthermofisher.com/pipettetips

NOTE: To avoid contamination, it is highly recommended that you have separate sets of pipettes for samples and extraction, PCR reaction setup, and any post-PCR processing. Ideally these steps should all be performed in separate laboratory spaces as well. Always follow necessary precautions when handling patient samples.

General laboratory equipment and consumables, cont.

Ordering Information

ProductSupplierRecommended productCat. No.
1-10 µL single channel adjustable volume pipetteThermo Fisher ScientificF1-ClipTip Variable Volume Single Channel Pipette (1-10 µL)4641320N
10–100 µL single channel adjustable volume pipetteThermo Fisher ScientificF1-ClipTip Variable Volume Single Channel Pipette (10–100 µL)4641200N
100–1,000 µL single channel adjustable volume pipetteThermo Fisher ScientificF1-ClipTip Variable Volume Single Channel Pipette (100–1,000 µL)4641230N
Multichannel pipette in 5–20 µL volume rangeThermo Fisher ScientificE1-ClipTip Equalizer 384 8-Channel (2–125 µL) or E1-ClipTip Equalizer 384 12-Channel (2-125 µL)4672060BT or 4672070BT
Multichannel pipette in 50–1,000 µL volume rangeThermo Fisher ScientificE1-ClipTip Equalizer 8-Channel Pipette (15–1,250 µL) (optional)4672100BT
10–300 µL multichannel pipetteThermo Fisher ScientificE1-ClipTip Equalizer 8-Channel (10–300 µL)4672080BT
30–850 µL multichannel adjustable volume pipette, 12-well (optional)Thermo Fisher ScientificE1-ClipTip 12-Channel Pipette (30–850 µL) (optional)4671090BT
15–1,250 µL single or multichannel adjustable volume pipette (optional)Thermo Fisher ScientificE1-ClipTip Electronic 1-Channel Pipette (15–1,250 µL) (optional) or E1-ClipTip Electronic 8-Channel Pipette (15–1,250 µL) (optional)4670040BT or 4671100BT
Aerosol-resistant barrier pipette tips, various sizes (1–1,250 µL)Thermo Fisher ScientificAerosol-resistant barrier tips compatible with F1-ClipTip and E1-ClipTip pipettesRecommended: 94420153, 94420813
Centrifuge with rotor for microplates and deep well platesThermo Fisher ScientificSorvall General Purpose Centrifuges, variousVarious
Laboratory vortex with plate padThermo Fisher ScientificVariousVarious
Biosafety cabinetThermo Fisher ScientificHerasafe 2030i Class 2 A2 Biological Safety Cabinets or 1300 Series Class II, Type A2 Biological Safety Cabinet Packages51032334 or 1336
PCR Workstation (optional)Fisher ScientificCombination PCR workstation36-101-8894 or 36-101-8897
Benchtop microcentrifuge to accommodate 1.5 mL tubesThermo Fisher ScientificmySPIN 6 Mini Centrifuge or Sorvall Legend Micro 21R Microcentrifuge, refrigerated75004061 or 75002447
-20°C freezerThermo Fisher ScientificTSX Series High-Performance -20°C Manual Defrost Freezers or similarTSX2320FA
-80°C freezerThermo Fisher ScientificTDE Series Ultra-Low Temperature Freezers or similarTDE60086FA
4°C refrigeratorThermo Fisher ScientificTSX Series High-Performance Laboratory Refrigerator or similarTSX3005GA
GlovesFisher ScientificVariousVarious
Safety glassesFisher ScientificVariousVarious
Laboratory coatFisher ScientificVariousVarious
General purpose lab tissues/wipersFisher ScientificKimberly-Clark Professional Kimwipes Delicate Task WipersS47299
ProductSupplierRecommended productCat. No.
Microcentrifuge tube rack for 1.5 mL tubesThermo Fisher ScientificFlipper Microtube Rack for 1.5 mL and 2.0 mL Tubes8760, 8770-11, 8780
Cold blocks, or ice and ice buckets (to accomodate reagent tubes and RT-PCR plate)Thermo Fisher ScientificBenchtop coolers and PCR cooler5116-1300 and 05-403-00
1.5 mL RNase-free microcentrifuge tubesFisher Scientific or Thermo Fisher ScientificMicrocentrifuge tubes, nonstick, RNase-free, 1.5 mL (250 tubes) or Snap Cap Low Retention Microcentrifuge Tubes, 1.5 mL, graduated, sterileRecommended: AM12450 or 21-402-903
RNase-free conical tubes, 15 mLThermo Fisher ScientificRNase-Free Conical Tubes, 15 mL (racked) (500 tubes)Recommended: AM12500
RNase-free conical tubes, 50 mLThermo Fisher ScientificRNase-Free Conical Tubes, 50 mL (racked) (200 tubes)Recommended: AM12501
Nalgene bottlesThermo Fisher ScientificNalgene Square PETG Media Bottles (125 mL)342020-0125
Reagent reservoirsThermo Fisher ScientificMatrix Reagent Reservoirs, polystyrene; 100 mL, individually wrapped, with divider95128085
Serological pipettesThermo Fisher ScientificNunc Serological Pipettes, individually wrapped, paper/plastic peel packaging, plugged170357 or 170358
Pipette fillerFisher ScientificS1 Pipet FillerVarious
96-well plate holderThermo Fisher ScientificMicroAmp Splash-Free 96-Well Base4312063
Reagent dispenser (optional)Thermo Fisher ScientificMultidrop Combi Reagent DispenserRecommended: 5840300

Find out more at thermofisher.com/covid19flursv

For In Vitro Diagnostic Use. Intended use of the products mentioned vary. For specific intended use statements, please refer to the product label. © 2020 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Windows is a trademark of Microsoft Corporation. Kimwipes is a trademark of Kimberly-Clark Worldwide, Inc. TaqMan is a registered trademark of Roche Molecular Systems, Inc., used under permission and license. Cy is a trademark of GE Healthcare. COL113197 1220

PDF preview unavailable. Download the PDF instead.

covid-19-flu-ab-rsv-checklist Adobe PDF Library 15.0 Adobe InDesign 16.0 (Macintosh)

Related Documents

Preview Urinary Tract Microbiota Profiling Experiments Application Guide
This application guide from Thermo Fisher Scientific details a high-throughput workflow for urinary tract microbiota profiling using TaqMan Assays on OpenArray Plates, MagMAX DNA isolation, and the QuantStudio 12K Flex instrument. It covers sample preparation, assay selection, data analysis, and troubleshooting for researchers studying the urinary tract microbiome.
Preview Thermo Fisher Scientific NEXT Magazine - March 2022
Explore the latest in life sciences research with Thermo Fisher Scientific's NEXT magazine (Issue 61, March 2022). This issue features an interview on SARS-CoV-2 antibodies, user voices on various research applications, and highlights of cutting-edge instruments and reagents, including cell sorters, gene editing tools, NGS solutions, and cell culture products.
Preview QuantStudio™ 3D Digital PCR System User Guide
User guide for the QuantStudio™ 3D Digital PCR System, detailing its use with compatible instruments, chips, and software for quantitative and qualitative detection of nucleic acid sequences. Includes setup, operation, troubleshooting, and safety information.
Preview Sensitivity and Specificity of BVDV Detection Technologies in Cattle
A study evaluating the sensitivity and specificity of various diagnostic technologies for detecting Bovine Viral Diarrhea Virus (BVDV) persistently infected (PI) cattle, including SNAP, ELISA, and RT-PCR methods.
Preview QuantStudio 6 Pro and 7 Pro Real-Time PCR System User Guide
Comprehensive user guide for the QuantStudio 6 Pro and QuantStudio 7 Pro Real-Time PCR Systems, covering installation, operation, maintenance, and troubleshooting.
Preview Thermo Fisher Scientific 802.11ac/a/b/g/n USB Dongle - Model 100097489
Technical specifications and identification details for the Thermo Fisher Scientific 802.11ac/a/b/g/n USB Dongle, model number 100097489. Includes FCC ID and IC information.
Preview RNA Reference Guide: Sample Preparation and Purification Solutions | Thermo Fisher Scientific
This comprehensive guide from Thermo Fisher Scientific details advanced solutions for RNA isolation and purification. It covers various technologies including organic extraction, spin columns, and magnetic beads, alongside instruments like KingFisher, Qubit, and NanoDrop. Discover TRIzol, PureLink, MagMAX, Dynabeads, and Cells-to-CT kits for efficient sample preparation in molecular biology research.
Preview QuantStudio™ Design and Analysis Software v2 Command-Line Application User Guide
This user guide provides comprehensive instructions for the QuantStudio™ Design and Analysis Software v2 Command-Line Application. It covers essential topics such as setting up the application on Windows and Macintosh systems, running commands for experiment file creation and data export, understanding command syntax and arguments, and managing supporting files.