Key Features
Seasonal Coefficient of Performance (SCOP): 4.0
Operating Temperature: -15°C for cooling, -22°C for heating
Technology: Digital DC Inverter SKYR
Functionality: Auto restart memory
Durability: Anti-corrosive gold fins
Cold Climate Features: Drip tray heater, Compressor crankcase heater
Low Temperature Operation: Cooling down to -15°C, Heating down to -22°C
Diagnostics: Self-diagnostics system
System Compatibility: Supports 1:X Multi Split systems
The outdoor unit is designed for multi-split air conditioning systems, offering efficient heating and cooling performance across a wide range of outdoor temperatures.
Technical Specifications
Specification | Details | Unit |
---|---|---|
Model | Hiro S 5,3 kW (Outdoor Unit H50Xm2 R15) | |
EAN Product Code | 5905567601637 | |
Refrigerant Type | R32 | |
Compressor Type | Rotary DC | |
Cooling Capacity (Nominal) | 5275 (970-6520) | W |
Cooling Rated Input (Nominal) | 1630 (125-2000) | W |
Cooling Operating Current (Nominal) | 7,1 (0,5-8,7) | A |
Heating Capacity (Nominal) | 5568 (1030-7000) | W |
Heating Rated Input (Nominal) | 1500 (250-1670) | W |
Heating Operating Current (Nominal) | 6,5 (1,1-7,3) | A |
Design Load in Cooling Mode | 5,3 | kW |
SEER (Energy Efficiency Class, Cooling) | 6,3 (A++) | W/W |
Annual Electric Energy Consumption (Cooling) | 294 | kWh/a |
Design Load in Heating Mode (Tbiv -7°C) | 4,3 | kW |
SCOP (Energy Efficiency Class, Heating) | 4,0 (A+) | W/W |
Annual Electric Energy Consumption (Heating) | 1575 | kWh/a |
Maximum Energy Consumption | 3050 | W |
Maximum Operating Current | 13,3 | A |
Fan Speed (H/M/L) | 850 / 800 / 750 | rpm |
Maximum Air Flow | 2200 | m³/h |
Sound Pressure Level | 54 | dB(A) |
Sound Power Level | 65 | dB(A) |
Net Dimensions (W×D×H) | 805 × 330 × 554 | mm |
Gross Dimensions (W×D×H) | 920 × 380 × 615 | mm |
Bracket Spacing (W×D) | 511 × 317 | mm |
Net Weight / Gross Weight | 35,5 / 38,5 | kg |
Refrigerant Charge (Designed) | 1,25 (up to 15 meters) | kg |
Refrigerant Charge (Extra) | 0,84 (over 15 meters) | |
TCO₂eq | 12 | |
Pipe Connections (Liquid/Gas) | 2 × 6,35 / 9,52 (2 × 1/4" / 3/8") | mm (inches) |
Max. Possible Indoor Unit Connections | 2 | pcs. |
Max. Installation Length (All Units) | 40 | m |
Max. Installation Length (Per Unit) | 25 | m |
Max. Height Difference (Outdoor Higher) | 10 | m |
Max. Height Difference (Outdoor Lower) | 15 | m |
Max. Height Difference (Between Indoor Units) | 10 | m |
Outdoor Unit Power Supply | 220-240~50, 1f | V-Hz, Ø |
Electrical Protection | B16 | A |
Power Cables (Outdoor Unit) | 3 × 2,5 | pcs × mm² |
Control/Power Cables (Indoor-Outdoor) | 4 × 1,5 | pcs × mm² |
Indoor Operating Range (Cooling / Heating) | -15~50 / -22~24 | °C |
Outdoor Operating Range (Cooling / Heating) | -15~50 / -22~24 | °C |
Note: Rotenso reserves the right to make changes to its products without prior notice.