Instruction Manual for eWBM models including: 2ARG9-ELR900H, 2ARG9ELR900H, eLR-900H OEM Integrator LoRa Module, OEM Integrator LoRa Module, LoRa Module, Module

Manual of eLR-900H module-2022.05.27

User Manual

eWBM Co.,Ltd. ELR900H 2ARG9-ELR900H 2ARG9ELR900H elr900h


File Info : application/pdf, 17 Pages, 3.35MB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=6151390
KD/Z/ZD
CONFIDENTIALINFORMATION

LoRa Module eLR-900H
eLR-900H
Product manual
Ver 1.0 2022.05.17
1

PRODUCT : LoRa Module
MODEL NAME : eLR-900H
APPTOVAL

LoRa Module eLR-900H
REMARK

Revision eLR-900H-REV0.1

History Initial release

Date 2022.05.17

Designed

Checked

Approved
eWBM Co., Ltd.

DOCUMENT No. eLR-900H
PAGE
1. Product Introduction The eLR-900H is a low-power LoRa (Long Range Wide-Area Network) module.
2

LoRa Module eLR-900H
The data transfer rate is 980bps~21.0Kbps. This module is applicable to smart tracking, sensor and control solutions of various devices that support security systems. 2. Purpose

This specification applies to "eWBM LoRa module". 3. eLR-920H Mechanical Dimensions

Size Weight Interface

14.90mm(W) x 17.90mm(L) x 2.4mm(T) 1.0g
LQFP-48

3.1 External Appearance

Figure 3-1 eLR-900H Top

Figure 3-2 eLR-900H Bottom

3

3.2 eLR-900H Module Dimension

LoRa Module eLR-900H

(Unit : mm) 3.3 eLR-900H Foot Print
4

LoRa Module eLR-900H
4. Specifications of supported functions 1) LoRa Modulation technology. 2) Use the `STM32WL' MCU with security system. 3) eLR-900H support UART, SPI interface. 4) 902.3MHz ~914.9MHz ISM band operates. 5) Module outline dimension : 14.90 x 17.90 x Max. 2.40 (mm) 6) 32.768kHz and 32MHz crystal embedded. 7) LPUART Data Rate : 9600bps (AT Commend)

5. Electrical Characteristics 1) Recommended Operating Rating

Parameter

Min

Operating Temperature

-30

Supply Voltage (VDD)

3.0

2) Current Consumption

Max

Unit

70

°C

3.6

V

Mode Tx Mode
Rx Mode Sleep Mode Deep Sleep Mode

Description Tx Mode Operating (Tx power = 18.5dBm) Rx Mode Operating CLI Commend (Module Master) CLI Commend (Module Slave)

Total Typ. Current at 3.3V  96.0mA
 4.8mA  11.0uA  1.0uA

5

3) RF Characteristic

LoRa Module eLR-900H

Parameter

Min

Typ

Frequency (MHz)

902.3

-

TX

Frequency Tolerance (KHz) , -20

-

25

Output Power Max (dBm) Pout  18.5 over

RX Receiving Sensitivity Sensitivity  -136

(dBm),Conductive

(F=12 ,BW= 125KHz)

Max 914.9 +20

6. eLR-900H PIN Assignment

6

7. ELR-900H PIN Description

LoRa Module eLR-900H

7.1 I/O Parameter Description

Abbreviation

Definition

S

Supply pin

I

Input only pin

IO

Input / output pin

O

Output only pin

RF

Radio RF pin

Table 7-1 I/O Parameter Descriptions

Remarks

7.2. Pin Description

PIN

PIN Name

Functional Description

Remark

1

NC

-

N.C

NC

2

PA1

I/O

PA1_GPIO

PA1

3

LPUART1_TX

O

PA2/LPUART1_TX_Commend_ download

LPUART1_TX

4

LPUART1_RX

I

PA3/LPUART1_RX_ Commend_ download

LPUART1_RX

5

GND

Supply

Ground connection

GND

6

UART1_TX

I/O

PB6/UART1_TX

UART1_TX

7

UART1_RX

I/O

PB7/UART1_RX

UART1_RX

8

SWCLK

I

SWCLK

SWCLK

9

SWDIO

I

SWDIO

SWDIO

10

GND

Supply

Ground connection

GND

11

SPI1_MOSI

I/O

PA7_SPI1_MOSI

SPI1_MOSI

12

SPI1_SCK

I/O

PA5_SPI1_SCK

SPI1_SCK

13

SPI1_MISO

I/O

PA6_SPI1_MISO

SPI1_MISO

14

SPI1_NSS

I/O

PA4_SPI1_NSS

SPI1_NSS

15

GND

Supply

Ground connection

GND

16

VREF+

Supply

Positive reference voltage

VREF+

17

PH0

-

N.C

PH0

7

LoRa Module eLR-900H

18

VDD

Supply

Supply voltage-3.3V

VDD

19

GND

Supply

Ground connection

19

20

PB4

I/O

PB4_GPIO

20

21

PB5

I/O

PB5_GPIO

21

22

PA8

I/O

PA8_GPIO

22

23

PA9

I/O

PA9_GPIO

23

24

GND

Supply

Ground connection

24

25

GND

Supply

Ground connection

25

26

NRST

I

Reset (Active Low)

26

27

VDD_RF

RF_Supply

RF Supply voltage-3.3V

27

28

GND

Supply

Ground connection

28

29

PC13

I/O

PC13_GPIO

29

30

WKUP1

I/O

PB12_WAKE_UP1: Rising Edge, Payload data bit2

30

ADC_IN2_VBATT
31

I/O

PB3_ADC_IN2_VBATT

31

32

PB8

I/O

PB8_GPIO

32

33

PA15

I/O

PA15_ADC11

33

I2C1_SCL
34

I/O

PA12_I2C2_SCL

34

12C_SDA
35

I/O

PA11_I2C2_SDA

35

WKUP2
36

I/O

PB2/WAKE_UP2

36

BOOT0
37

-

BOOT0(NC)

37

38

GND

Supply

Ground connection

38

39

GND

Supply

Ground connection

39

NC
40

-

N.C

40

41

GND

Supply

Ground connection

41

NC
42

-

N.C

42

43

GND

Supply

Ground connection

43

NC
44

-

N.C

44

45

GND

Supply

Ground connection

45

46

GND

Supply

Ground connection

46

47

RF

RF I/O

External 50 port for Antenna connection

47

48

GND

Supply

Ground connection

48

8

1) eLR-900H Circuit Module Application Circuit

LoRa Module eLR-900H

9

ANTENNA
Please perform the antenna design that followed the specifications of the antenna About the signal line between an antenna and a module It is a 50-ohm line design. (SMA Reverse) Fine tuning of return loss etc. can be performed using a matching network. However, it is required to check "Class1 change" and "Class2 change" which the authorities define then.
The concrete contents of a check are the following three points. 1) It is the same type as the antenna type of antenna specifications. 2) An antenna gain is lower than a gain given in antenna specifications. 3) The emission level is not getting worse.

Antenna gain
Electrical Data Frequency Range Impedance
V.S.W.R Gain (Peak) Radiation Pattern Polarization

Specifications 902.3 ~ 914.9MHz 50 Normal Less Than 1:2.5 0.91dBi Omni-Directional Linear
Antenna Specification

Antenna Reference Trace Design
RF traces from eLR-900H module pads pin 47 and ANT1 pin 1 to the antenna must be made using micro-strip traces. This micro-strip trace must respect the design of the Gerber file associated with the following figures in order to obtain a uniform transmission line with a characteristic impedance of 50 ohms. The reference trace design is shown as the pink trace along with the side copper filled with vias on the left side. of Figure where components C8, C9 are not installed; they were options on the reference board for future uses; these uses are not FCC authorized yet. As preliminary information the traces width of all sections are all 0.5mm and the length of eLR-900H pad to ANT1 connector are 50mm; However, refer to associated Gerber files for more details on dimensions and refer to eWBM Inc for more details on the Gerber files. Table 1 shows the parts used in the reference trace design.
Antenna Reference Trace Design

Part Number WR04X0000FTL
SMA-4R-PCB(1.8T) N/A

Reference L1
ANT1 C8, C9

Description 0 ohm, 1% SMA, Subminiature Coaxial Connector 50 ohm Not Installed

Antenna Micro-strip Trace Parts

Manufacture WALSIN
Sungjin N/A

Contetns PCB Stack-Up and Trace
PCB Stack up for the reference board:
PCB Stack-Up

Contetns
PCB Trace
Test Procedure for ensuring compliance
The below test is to be performed both at design verification stage and in production for ensuring compliance. Verify RF power through conducted measurement at junction ANT1 The measured Tx power should be within the datasheet specification for Transmit output power.

FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. The antenna(s) must be installed such that a minimum separation distance of at least 20 cm is maintained between the radiator (antenna) and all persons at all times.

NTEGRATION INSTRUCTIONS The module complies with Part15.247/RSS-247. The modular transmitter is only FCC authorized for the specific rule part(i.e, FCC transmitter rules) listed on the grant. The host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. The final host / module combination may also need to be evaluated against the FCC Part 15B criteria for unintentional radiators in order to be properly authorized for operation as a Part 15 digital device. The module is authorized with trace antenna design type. And the module is designed to operate with a Helicalantenna. (Connector: SMA - R / peak gain: 0.91dBi) The trace antenna design must be performed as specified in the manual. The use of any other antenna or any changes to the reference trace design are subject to additional testing and authorization through a Class II permissive change. The module is a limited single-modular transmitter that complies with the § 15.212(a) modular rules which requires the host operating condition as ; The host product should supply the regulated power of 3.3V DC to module. The power design should be performed as specified in the manual. The module is limited to installation in mobile or fixed applications. At least 20 cm of separation distance between the transmitting antenna device and the user's body must be maintained at all times. The transmitter module must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. The OEM integrator will be responsible to satisfy SAR/ RF Exposure requirements, when the module integrated into the host device. The module is labeled with its own FCC ID certification. If the FCC ID Certification Number are not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. In that case, the final end product must be labeled in a visible area with the following: "Contains FCC ID: 2ARG9-eLR900H
Host User Manual
The host manual shall include the following regulatory statement; Part 15.19: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Part 15.21: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. The antenna(s) must be installed such that a minimum separation distance of at least 20 cm is maintained between the radiator (antenna) and all persons at all times.

Host Product labeling The module is labeled with its own FCC ID certification. If the FCC ID Certification Number are not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. In that case, the final end product must be labeled in a visible area with the following: "Contains FCC ID: 2ARG9-eLR900H

