Owner's Manual for MEAN WELL models including: RS-50, RS-50 Series 50W Single Output Switching Power Supply, RS-50 Series, RS-50 Series Output Switching Power Supply, 50W Single Output Switching Power Supply, 50W Power Supply, Single Output Switching Power Supply, Single Output Power Supply, Switching Power Supply, Power Supply
23 feb 2024 — 3.3V. 5V. 12V. 15V. 24V. 48V. 10A. 10A. 4.2A. 3.4A. 2.2A. 1.1A. 0 ~ 10A. 0 ~ 10A. 0 ~ 4.2A. 0 ~ 3.4A. 0 ~ 2.2A. 0 ~ 1.1A. 33W. 50W. 50.4W. 51W. 52.8W. 52.8W.
File Name:RS-50-SPEC 2024-02-23 Mechanical Specification Case No. 905B Unit:mm AMBIENT TEMPERATURE ( )℃-25-25 0 0 10 30 4020 20 40 80 60 100 50 60 70 Output Derating VS Input Voltage
File Info : application/pdf, 2 Pages, 137.75KB
DocumentDocument50W Single Output Switching Power Supply RS-50 series GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION Features : Universal AC input / Full range User's Manual Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test No load power consumption<0.5W High efficiency, long life and high reliability 3 years warranty AS/NZS62368-1 GB4943.1 UL62368-1 Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 IEC62368-1 TPTC004 MODEL RS-50-3.3 RS-50-5 RS-50-12 RS-50-15 RS-50-24 RS-50-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 10A 10A 4.2A 3.4A 2.2A 1.1A CURRENT RANGE 0 ~ 10A 0 ~ 10A 0 ~ 4.2A 0 ~ 3.4A 0 ~ 2.2A 0 ~ 1.1A RATED POWER 33W 50W 50.4W 51W 52.8W 52.8W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE 3V ~ 3.6V VOLTAGE TOLERANCE Note.3 ±3.0% LINE REGULATION Note.4 ±0.5% LOAD REGULATION Note.5 ±2.0% 4.75 ~ 5.5V ±2.0% ±0.5% ±1.0% 10.8 ~ 13.2V ±1.0% ±0.5% ±0.5% 13.5 ~ 16.5V ±1.0% ±0.5% ±0.5% 22 ~ 27.2V ±1.0% ±0.5% ±0.5% 42 ~ 54V ±1.0% ±0.5% ±0.5% SETUP, RISE TIME 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 60ms/230VAC 14ms/115VAC at full load VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY(Typ.) 78% 83% 84.5% 86% 88% 89% AC CURRENT (Typ.) 1.3A/115VAC 0.8A/230VAC INRUSH CURRENT (Typ.) COLD START 33A/230VAC LEAKAGE CURRENT <2mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ±0.03%/ (0 ~ 50) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes 27.6 ~ 32.4V 55.2 ~ 64.8V SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 , EAC TP TC 004, CCC GB4943.1 approved SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE (Note 6) EMC EMISSION I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020 EMC IMMUNITY MTBF Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020 2956.7K hrs min. Telcordia SR-332 (Bellcore) ; 575.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION PACKING 99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.94CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:RS-50-SPEC 2024-02-23 50W Single Output Switching Power Supply Mechanical Specification RS-50 series Case No. 905B Unit:mm 36 2-M3 L=4 51.5 9.5 3.5 1 2 3 5.5 4 5 97 8.2 55.5 7 17.5 28 36 20.5 55 3.5 4.5 89 99 6.5 87 3.5 2-M3 L=4 18 74 3.5 Block Diagram Terminal Pin No. Assignment Pin No. Assignment Pin No. 1 AC/L 4 2 AC/N 5 3 FG Assignment DC OUTPUT -V DC OUTPUT +V fosc : 60KHz I/P EMI FILTER RECTIFIERS & POWER SWITCHING RECTIFIERS & FILTER FILTER +V -V FG DETECTION CIRCUIT O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage 100 80 60 40 20 -25 0 10 20 30 40 50 60 70 (HORIZONTAL) -25 0 AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RS-50-SPEC 2024-02-23 LOAD (%) LOAD (%)