Rotenso Aquami Series Product Fiche
Detailed technical specifications and energy efficiency information.
General Information
Supplier's Name or Trademark: Rotenso
Supplier's Model Identifiers: AQS100X10 R14, AQS100X13i R14, AQS100T190X1i R14, AQS100T240X13i R14
Manufacturer: ROTENSO, ul Szyb Walenty 16, 41-700 Ruda Śląska, Poland
Importer: THERMOSILESIA, ul Szyb Walenty 16, 41-700 Ruda Śląska, Poland
Technical Specifications
Parameter | Unit | Value 1 | Value 2 |
---|---|---|---|
Temperature application | °C | 35 | 55 |
Seasonal space heating energy efficiency class | A+++ | A++ | |
Rated heat output (average climate) | kW | 9.2 | 7.7 |
Seasonal space heating energy efficiency (average climate) | % | 204.8 | 135.7 |
Annual energy consumption (average climate) | kWh | 3644 | 4567 |
Sound power level (Indoors) | dB | 40 | 40 |
Sound power level (Outdoors) | dB | 60 | 60 |
Rated heat output (colder climate conditions) | kW | 7.7 | 6.7 |
Rated heat output (warmer climate conditions) | kW | 8.6 | 8.6 |
Seasonal space heating energy efficiency (colder climate conditions) | % | 169.8 | 116.5 |
Seasonal space heating energy efficiency (warmer climate conditions) | % | 280.5 | 181.7 |
Annual energy consumption (colder climate conditions) | kWh | 4423 | 5539 |
Annual energy consumption (warmer climate conditions) | kWh | 1617 | 2496 |
Note: Annual energy consumption refers to the energy consumption required to meet the reference annual heating demand for the designated heating season, in accordance with EU Regulation No. 811/2013.
Please check the information on the appliance matches the model name on the nameplate.
Safety and Environmental Information
Precautions: Before any assembly, installation, or maintenance, read the unit's assembly and operating instructions and follow the information provided.
Refrigerant Information: Refrigerant leakage contributes to climate change. This appliance contains a refrigerant fluid with a GWP of [675]. If 1kg of this fluid leaks into the atmosphere, its impact on global warming is [675] times higher than 1kg of CO2 over 100 years. Never interfere with the refrigerant circuit or disassemble the product yourself; always seek professional assistance.