Nice RGBW-Control

Universal remote control for RGB/RGBW and other LEDs

EN - Instructions and warnings for installation and use

v 1.2

Compatible with Yubii ECOSYSTEM

1 WARNINGS AND GENERAL PRECAUTIONS

2 PRODUCT DESCRIPTION

RGBW-Control is a universal, Z-Wave Plus® compatible RGB/RGBW controller. The device uses PWM output signal, which enables controlling LED, RGB, RGBW strips, halogen lights and other resistive loads. It can also measure active power and energy consumed by the load. Controlled devices can be powered by 12 or 24V DC.

Inputs support momentary/toggle switches, potentiometers, and 0 - 10 V analog sensors, such as temperature sensors, humidity sensors, light sensors.

2.1 - Main features

2.2 - Full compatibility with Z-Wave Plus® devices

This device can be used with all devices accredited with the Z-Wave® Plus certificate and is compatible with such devices produced by other manufacturers. All non-battery operated devices within the network act as repeaters to increase reliability of the network. The device is a Security Enabled Z-Wave® Plus product and a Security Enabled Z-Wave® Controller must be used to fully utilize the product.

3 TECHNICAL SPECIFICATIONS

RGBW-Control is produced by Nice S.p.A. (TV).

Note: All technical specifications stated in this section refer to an ambient temperature of 20 °C (± 5 °C). Nice S.p.A. reserves the right to apply modifications to the product at any time when deemed necessary, while maintaining the same functionalities and intended use.

Table 1 - RGBW-Control - Hardware parameters
Parameter Values / types
Power supply 12V/24V DC ±10%
Rated load current 6 A for channel, 12 A total for all outputs
Power output 144 W combined for 12 V, 288 W combined for 24 V
Inputs 4 inputs, 0 - 10 V (configurable pull-up) or binary
Outputs 4 outputs, PWM
PWM frequency 244Hz
Overvoltage category OVCI
Rated impulse voltage 330 V
Maximum length of wires 2 m
Operating temperature 0-40°C (32 - 104°F)
Shipping and storage temperature -40 – 60°C (-40 – 140°F)
Recommended wire cross-section area 0.2 – 2.0 mm² (24 – 14 AWG), depending on load current
Dimensions (Length x Width x Height) 42.35 x 36.90 x 17.5 mm (1.67" x 1.5" x 0.69")
Device type Type 1.C Action
Pollution degree 2
Software class Class A
Maximum phase to ground voltage of the supply source Supplied by external SELV source up to 24V DC
Protection against electric shock class Class III control
Classification of installation and use Independently, Flush Mounted operating control (lighting control)
Supply Connection Permanent connection
Radio protocol Z-Wave (500 series chip)
Radio frequency band • 868.4 or 869.8 MHz EU
• 908.4 or 916.0 MHz US
• 921.4 or 919.8 MHz ANZ
Max. transmitting power EIRP up to 5 dBm
Range • up to 50 m outdoors,
• up to 40 m indoors

Note: Radio frequency of individual device needs to be the same as your Z-Wave hub. Check information on the box or consult your dealer if you aren't sure.

4 INSTALLATION

Connecting the device in a manner inconsistent with this manual may cause risk to health, life or material damage.

4.1 - Notes for the figures

4.2 - Connection with RGBW/RGB LED strip

We recommend connecting LED strip channels in the same order as in Figure 2 (R - OUT1, G - OUT2, B - OUT3, W - OUT4). If you want to connect RGB strip, use the same figure, but don't connect OUT4 channel.

  1. Disconnect the power.
  2. Connect in accordance with Figure 2.
  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.

Note: The device works in RGBW mode by default. To enable HSB mode change parameter 150 to 1.

4.3 - Connection with one-color LED strips

  1. Disconnect the power.
  2. Connect in accordance with Figure 3.
  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.

4.4 - Connection with halogen lights

  1. Disconnect the power.
  2. Connect in accordance with Figure 4.
  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.

4.5 - Connection with 0-10V analog sensors

The 2-wire analog sensor requires pull-up resistor. You can connect up to 4 analog sensors to IN1/IN2/IN3/IN4 terminals.

  1. Disconnect power.
  2. Connect with the diagram on the right.
  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.
  6. Change values of parameters:
    • Connected to IN1:
      » Doesn't require pull-up: change parameter 20 to 0
      » Requires pull-up: change parameter 20 to 1
    • Connected to IN2:
      » Doesn't require pull-up: change parameter 21 to 0
      » Requires pull-up: change parameter 21 to 1
    • Connected to IN3:
      » Doesn't require pull-up: change parameter 22 to 0
      » Requires pull-up: change parameter 22 to 1
    • Connected to IN4:
      » Doesn't require pull-up: change parameter 23 to 0
      » Requires pull-up: change parameter 23 to 1

5 ADDING DEVICE TO Z-WAVE NETWORK

Adding (Inclusion) - Z-Wave device learning mode, enabling you to add the device to the existing Z-Wave network.

5.1 - Adding manually

To add the device to the Z-Wave network manually:

  1. Power the device.
  2. Set the main hub in the (Security/non-Security Mode) add mode. For more information, see the hub manual.
  3. Quickly, three times click the service button.
  4. If you are adding in Security S2 Authenticated, input the underlined part of the DSK, which is labelled on the box.
  5. LED starts blinking yellow, wait for the adding process to end.
  6. Adding result is confirmed with the Z-Wave hub message and the LED color:
    • Green - successful (non-secure, SO, S2 Unauthenticated)
    • Magenta - successful (Security S2 Authenticated)
    • Red - not successful
5.2 - Adding using SmartStart

With the SmartStart solution products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a hub providing SmartStart inclusion. The SmartStart product is added automatically within 10 minutes after being switched on in the network range.

Note: To use SmartStart your hub needs to support Security S2. For more information, see the hub manual.

To add the device to the Z-Wave network using SmartStart:

  1. Enter the full DSK string code to your hub. If your hub is capable of QR scanning, scan the QR code placed on the label on the box.
  2. Power the device.
  3. Wait for the adding process to start (up to a few minutes), which is signalled with yellow LED blinking.
  4. Adding result is confirmed with the Z-Wave hub message and the LED color:
    • Green - successful (non-secure, SO, S2 Unauthenticated)
    • Magenta - successful (Security S2 Authenticated)
    • Red - not successful

6 REMOVING DEVICE FROM Z-WAVE NETWORK

Removing (Exclusion) - Z-Wave device learning mode, enabling you to remove the device from existing Z-Wave network.

To remove the device from the Z-Wave network:

  1. Power the device.
  2. Set the main hub into the remove mode. For more information, see the hub manual.
  3. Quickly, three times click the service button.
  4. LED starts blinking yellow, wait for the removing process to end.

Successful removing is confirmed with the Z-Wave hub message and red LED color.

Note: Removing RGBW-Control from the Z-Wave network restores all the default parameters of the device, but doesn't reset power metering data.

7 OPERATING THE DEVICE

7.1 - Controlling connected loads in RGBW mode (default)

Input can control output with the same number. For example, switch connected to IN1 controls load connected to output OUT1. Perform actions on inputs listed in the table below to change state of the connected load:

Dimm/brighten color
Table 2 - RGBW-Control - Responses to button actions
Action Response
1 click Change to the opposite one (ON/OFF)
2 clicks Set color to 100%
Hold/release

Note: A single click switches between the OFF state and the last non-OFF state. It means it can set the colour back, but the light can't light up as it doesn't change the brightness.

7.2 - Controlling connected loads in HSB mode

HSB mode is enabled by setting parameter 150 to 1. Inputs correspond to different components in HSB color space: IN1 – Hue, IN2 – Saturation, IN3 - Brightness and IN4 input controls OUT4 output. Perform actions listed in the table below on inputs to change values of the components:

Table 3 - RGBW-Control - HSB mode
Action Response
1 click when value is 0 Restore last set value
1 click when value isn't 0 Set value to 0
2 clicks Set value to max
Hold/release Increase/decrease value:
• When you hold the button connected to IN1, you revolve around the cone on the H (Hue) axis.
Note: If the saturation is too low, you may not notice any changes while holding IN1.
• When you hold the button connected to IN2, you change the saturation (S).
• When you hold the button connected to the IN3, you change the brightness (B).
Other actions: 1, 2, 3 x click/hold/release Activate scene in the hub for a specific action, requires prior configuration

7.3 - Visual indications

The built-in LED light shows current device status.

Table 4 - RGBW-Control - Responses to button actions
Action Color Meaning
After powering the device: Green Device added to a Z-Wave network (without Security S2 Authenticated)
Magenta Device added to a Z-Wave network (with Security S2 Authenticated)
Red Device not added to a Z-Wave network
Update Blinking cyan Update in progress
Green Update successful
Red Update not successful
Menu Blinking green Entering the menu (added without Security S2 Authenticated)
Blinking magenta Entering the menu (added with Security S2 Authenticated)
Blinking red Entering the menu (not added to a Z-Wave network)
Green Resetting energy consumption memory
Yellow Resetting to factory defaults

7.4 - Menu

Menu enables performing the Z-Wave network actions.

To use the menu:

  1. Press and hold the service button to enter the menu, device blinks to signal adding status. For more information, see 7.3 - Visual indications.
  2. Release the service button when device signals desired position with color:
    • GREEN - reset energy consumption memory
    • YELLOW - reset to factory defaults
  3. Quickly click the service button to select, 2 blinks of the same color confirms the selection.

7.5 Resetting to factory defaults

Reset procedure enables you to restore the device back to its factory settings, which means all information about the Z-Wave hub and user configuration are deleted. Resetting to factory defaults doesn't reset energy consumption memory.

  1. Press and hold the service button to enter the menu.
  2. Release service button when the device glows yellow.
  3. Quickly click the service button to confirm.
  4. After a few seconds the device is restarted, which is signalled with the red color.

Note: Resetting the device isn't a recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary hub is missing or inoperable. Certain device removal can be achieved by the procedure of removing device from Z-Wave network.

8 ACTIVATING SCENES

The device can activate scenes in the Z-Wave hub by sending scene ID and attribute of a specific action using Central Scene Command Class. For this functionality to work, connect momentary or toggle switch to the IN1-IN4 inputs and set parameters 20-23 to 2, 3 or 4 (depending on type of switch).

Table 5 - RGBW-Control - Scene IDs for inputs
Input Scene ID
IN1 1
IN2 2
IN3 3
IN4 4
Table 6 - RGBW-Control - Attributes for actions
Action Attribute
Switch clicked once Key Pressed 1 time
Switch clicked twice Key Pressed 2 times
Switch clicked thrice Key Pressed 3 times
Switch held* Key Held Down
Switch released* Key Released

* Not available for toggle switches.

9 ASSOCIATIONS

Association (linking devices) - direct control of other devices within the Z-Wave system network.

Associations enables:

Note: Commands send to the 2nd – 10th association groups reflect inputs operation according to device configuration. For example, turning the first channel on using input sends frame responsible for the same action.

Table 7 - RGBW-Control - Association groups
Association group Name Description
1st Lifeline Reports the device status and enables assigning a single device, the hub by default. Only one node can be assigned.
2nd RGBW Sync Enables synchronizing the state of other RGBW-Control devices
3rd On/Off (IN1) Used for turning the associated devices on/off reflecting IN1 operation
4th Dimmer (IN1) Used for changing the level of associated devices reflecting IN1 operation
5th On/Off (IN2) Used for turning the associated devices on/off reflecting IN2 operation
6th Dimmer (IN2) Used for changing the level of associated devices reflecting IN2 operation
7th On/Off (IN3) Used for turning the associated devices on/off reflecting IN3 operation
8th Dimmer (IN3) Used for changing the level of associated devices reflecting IN3 operation
9th On/Off (IN4) Used for turning the associated devices on/off reflecting IN4 operation
10th Dimmer (IN4) Used for changing the level of associated devices reflecting IN4 operation

Note:
• Association groups 2 - 10 can be triggered only from buttons connected to IN1-IN4 and don't work for 0 - 10 V sensors.
• The device enables controlling 5 regular or multichannel devices per an association group, with the exception of "Lifeline" that is reserved solely for the hub and hence only 1 node can be assigned.

Table 8 - RGBW-Control - Assocation groups mapping
Root Endpoint Association group in endpoint
Association Group 1 Endpoint 1 - 9* Association Group 1
Association Group 2 Endpoint 1 Association Group 2
Association Group 3 Endpoint 2 Association Group 2
Association Group 4 Endpoint 2 Association Group 3
Association Group 5 Endpoint 3 Association Group 2
Association Group 6 Endpoint 3 Association Group 3
Association Group 7 Endpoint 4 Association Group 2
Association Group 8 Endpoint 4 Association Group 3
Association Group 9 Endpoint 5 Association Group 2
Association Group 10 Endpoint 5 Association Group 3

* max nodes supported: 0

Table 9 - RGBW-Control - Basic commands mapping
Command Root Endpoints
1 - 5 6 - 9
Basic Set EP1 Switch Multilevel Set
Basic Get = EP1 Switch Multilevel Get
Basic Report = EP1 Switch Multilevel Report
Sensor Multilevel Get
Sensor Multilevel Report

9 ADVANCED PARAMETERS

The device enables customizing its operation to user's needs with configurable parameters. The settings can be adjusted using Z-Wave hub to which the device is added. The way of adjusting them might differ depending on the hub.

Table12 - RGBW-Control - Advanced parameters
Parameter Description Available setting Default setting Length
1. Remember device status before the power failure Determines how the device reacts in case of power supply failure, such as power outage or taking out from the electrical outlet. After the power supply is back on, the device can be restored to previous state or remain switched off. The sequence isn't remembered after the power failure. After power failure, the last color set before the sequence is restored. • 0 - device remains switched off
• 1 - device restores the state from before the power failure
0 1B
20. Input 1 - operating mode Enables choosing mode of the 1st input (IN1). Change it depending on connected device. • 0 - Analog input without internal pull-up (Sensor Multilevel)
• 1 - Analog input with internal pull-up (Sensor Multilevel)
• 2- Momentary switch (Central Scene)
• 3-Toggle switch: switch state on every input change (Central Scene)
• 4- Toggle switch: contact closed – ON, contact opened - OFF (Central Scene)
2 (momentary switch) 1B
21. Input 2 - operating mode Enables choosing mode of the 2nd input (IN2). Change it depending on connected device • 0 - Analog input without internal pull-up (Sensor Multilevel)
• 1 - Analog input with internal pull-up (Sensor Multilevel)
• 2- Momentary switch (Central Scene)
• 3-Toggle switch: switch state on every input change (Central Scene)
• 4- Toggle switch: contact closed – ON, contact opened - OFF (Central Scene)
2 (momentary switch) 1B
22. Input 3 - operating mode Enables choosing mode of the 3rd input (IN3). Change it depending on connected device • 0 - Analog input without internal pull-up (Sensor Multilevel)
• 1 - Analog input with internal pull-up (Sensor Multilevel)
• 2- Momentary switch (Central Scene)
• 3-Toggle switch: switch state on every input change (Central Scene)
• 4- Toggle switch: contact closed – ON, contact opened - OFF (Central Scene)
2 (momentary switch) 1B
23. Input 4 - operating mode Enables choosing mode of the 4th input (IN4). Change it depending on connected device • 0 - Analog input without internal pull-up (Sensor Multilevel)
• 1 - Analog input with internal pull-up (Sensor Multilevel)
• 2- Momentary switch (Central Scene)
• 3-Toggle switch: switch state on every input change (Central Scene)
• 4- Toggle switch: contact closed – ON, contact opened - OFF (Central Scene)
2 (momentary switch) 1B
30. Alarm configuration - 1st slot Determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
X channels summarized: 1/2/3/4 channel are equal to values 1/2/4/8.
Y - sequence number: 1 - 10 (parameter 157)
1B [MSB] - Notification Type
2B-Notification Status
3B-Event/State Parameters
4B [LSB] - action:
0x00 - no reaction, OxOX – turn off selected channel, 0x1X – turn on selected channel, 0x2X - blink selected channel, 0x3Y - activate alarm sequence
[0x00,
0x00, 0x00,
0x00] (dis- abled)
4B
31. Alarm configuration - 2nd slot Determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
X - channels summarized: 1/2/3/4 channel are equal to values 1/2/4/8. Y sequence number: 1-10 (parameter 157).
1B [MSB] - Notification Type
2B-Notification Status
3B-Event/State Parameters
4B [LSB] - action:
0x00 no reaction, OxOX – turn off selected channel, 0x1X – turn on selected channel, 0x2X - blink selected channel, 0x3Y - activate alarm sequence
[0x05,
0xFF, 0x00,
0x00] (Water Alarm, any notification, no action)
4B
32. Alarm configuration - 3rd slot Determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
X - channels summarized: 1/2/3/4 channel are equal to values 1/2/4/8. Y - sequence number: 1 - 10 (parameter 157).
1B [MSB] - Notification Type
2B - Notification Status
3B - Event/State Parameters
4B [LSB] - action:
0x00 no reaction, OxOX – turn off selected channel, 0x1X – turn on selected channel, 0x2X - blink selected channel, 0x3Y - activate alarm sequence
[0x01, 0xFF, 0x00,
0x00] (Smoke Alarm, any notification, no action)
4B
33. Alarm configuration - 4th slot Determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
X - channels summarized: 1/2/3/4 channel are equal to values 1/2/4/8. Y - sequence number: 1 - 10 (parameter 157).
1B [MSB] - Notification Type
2B - Notification Status
3B - Event/State Parameters
4B [LSB] - action:
0x00 no reaction, OxOX – turn off selected channel, 0x1X – turn on selected channel, 0x2X - blink selected channel, 0x3Y - activate alarm sequence
[0x02, 0xFF,
0x00, 0x00] (CO Alarm, any notification, no action)
4B
34. Alarm configuration - 5th slot Determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
X - channels summarized: 1/2/3/4 channel are equal to values 1/2/4/8. Y - sequence number: 1 - 10 (parameter 157).
1B [MSB] - Notification Type
2B - Notification Status
3B - Event/State Parameters
4B [LSB] - action:
0x00 no reaction, OxOX – turn off selected channel, 0x1X – turn on selected channel, 0x2X - blink selected channel, 0x3Y - activate alarm sequence
[0x04, 0xFF,
0x00, 0x00] (Heat Alarm, any notification, no action)
4B
35. Duration of alarm signalization Determines the duration of alarm signaling (flashing mode and/or alarm sequence). 0 - infinite signalization 600 (10 min) 2B
40. Input 1 - sent scenes Defines which actions result in sending scene ID and attribute assigned to them. This parameter is relevant only if parameter 20 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. 1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key hold down and key released
15 1B
41. Input 2 - sent scenes Defines which actions result in sending scene ID and attribute assigned to them. This parameter is relevant only if parameter 21 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. 1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key hold down and key released
15 1B
42. Input 3 - sent scenes Defines which actions result in sending scene ID and attribute assigned to them. This parameter is relevant only if parameter 22 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. 1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key hold down and key released
15 1B
43. Input 4 - sent scenes Defines which actions result in sending scene ID and attribute assigned to them. This parameter is relevant only if parameter 23 is set to 2, 3 or 4. Actions can be summed up, e.g. 1+2+4+8=15 and entered as a value for the parameter. 1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key hold down and key released
15 1B
62. Power reports periodic Determines in what time intervals the periodic power reports are sent to the main hub. Periodic reports do not depend of power change (parameter 61). 30-32400 (30 - 32400 s) - report interval 3600 (1h) 2B
63. Analog inputs reports and output change on input change Defines minimal change (from the last reported) of analog input voltage that results in sending new report and change in the output value. This parameter is relevant only for analog inputs (parameter 20, 21, 22 or 23 set to 0 or 1). 0 - reporting on change disabled
1-100 (0.1-10 V, 0.1 V step)
5 (0.5 V) 2B
64. Analog inputs reports periodic Defines reporting period of analog inputs value. Periodic reports are independent from changes in value (parameter 63). The parameter is relevant only for analog inputs (parameter 20, 21, 22 or 23 set to 0 or 1). 0-periodical reports disabled
30-32400 (30 - 32400 s, 1 s step)
0 2B
65. Energy reports - on change Determines the minimum change in consumed energy that results in sending new energy report to the main hub. Energy reports are sent no often than every 30 seconds. 0 - reports are disabled
1-500 (0.01-5 kWh) - change in energy
10 (0.1 kWh) 2B
66. Energy reports periodic Determines in what time intervals the periodic energy reports are sent to the main hub. Periodic reports don't depend of energy change (parameter 65) 0 - periodic reports are disabled
30-32400 (30 - 32400 s) - report interval
3600 (1h) 2B
150. Inputs LED colour control mode Determines how connected switches control LED strips • 0 RGBW mode (every input controls output with the same number, IN1-OUT1, IN2-OUT2, IN3-OUT3, IN4-OUT4)
• 1 - HSB and White mode (inputs works in HSB color model, IN1-H (Hue), IN2-S (Saturation), IN3-B (Brightness), IN4-White (OUT4)
0 (RGBW mode) 1B
151. Local control - transition time Determines time of smooth transition between 0% and 100% when controlling with connected switches. 0 - instantly
1-127 (1s-127s, 1s step)
128 - 254 (1min - 127 min, 1min step)
3 (3 s) 2B
152. Remote control transition time Determines time needed to change the state between current and target values when controlling through Z-Wave network. 10
Table 10 - RGBW-Control - RGBW mode: commands sent to association groups for parameter 150 set to 0
Input 1 and 2 click Hold Release
Input 1 Basic Set: 3rd, Multilevel Set: 4th,
Switch Color Set: 2nd
Multilevel Start Level Change: 4th Multilevel Stop Level Change: 4th,
Switch Color Set: 2nd
Input 2 Basic Set: 5th, Multilevel Set: 6th,
Switch Color Set: 2nd
Multilevel Start Level Change: 6th Multilevel Stop Level Change: 6th,
Switch Color Set: 2nd
Input 3 Basic Set: 7th, Multilevel Set: 8th,
Switch Color Set: 2nd
Multilevel Start Level Change: 8th Multilevel Stop Level Change: 8th,
Switch Color Set: 2nd
Input 4 Basic Set: 9th, Multilevel Set: 10th,
Switch Color Set: 2nd
Multilevel Start Level Change: 10th Multilevel Stop Level Change: 10th,
Switch Color Set: 2nd
Table 11 - RGBW-Control - HSB mode: commands sent to association groups for parameter 150 set to 1
Input 1 and 2 click Hold Release
Input 1, 2, 3 Switch Color Set: 2nd Switch Color Set: 2nd
Input 4 Basic Set: 9th, Multilevel Set: 10th,
Switch Color Set: 2nd
Multilevel Start Level Change: 10th Multilevel Stop Level Change: 10th,
Switch Color Set: 2nd
Table12 - RGBW-Control - Advanced parameters
Parameter Description Available setting Default setting Length
154. ON frame value for single click Defines value sent to devices in association groups. The parameters consist of 4 bytes, each byte reserved for separate channel, from least significant (IN1) to most significant (IN4). Applicable for Basic Set and Switch Multilevel Set commands. For every byte: 0 - 99, 255 4294967295 (0xFF FF FF FF - 255 for all channels) 4B
155. OFF frame value for single click 0 (0x00 00 00 00 - 0 for all channels) 4B
156. ON frame value for double click 0 (0x63 63 63 63-99 for all channels) 4B
157. Start programmed sequence Setting this parameter starts programmed sequence with selected number. User can define own sequences using hub. While the sequence is active, the menu is unavailable. 0 - sequence inactive
1 - 5 - user-defined sequence
6 - Fireplace sequence
7 - Storm sequence
8 - Rainbow sequence
9 - Aurora sequence
10 - Police siren sequence (red-white-blue)
0 (sequence inactive) 1B

10 Z-WAVE SPECIFICATION

Table 13 - RGBW-Control - Supported Command Classes
Command Class Version Secure
1. COMMAND_CLASS_ZWAVEPLUS_INFO [0x5E] V2 YES
2. COMMAND_CLASS_SWITCH_MULTILEVEL [0x26] V4 YES
3. COMMAND_CLASS_ASSOCIATION [0x85] V2 YES
4. COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION [0x8E] V3 YES
5. COMMAND_CLASS_ASSOCIATION_GRP_INFO [0x59] V2 YES
6. COMMAND_CLASS_VERSION [0x86] V2 YES
7. COMMAND_CLASS_MANUFACTURER_SPECIFIC [0x72] V2 YES
8. COMMAND_CLASS_MULTI_CHANNEL [0x60] V4 YES
9. COMMAND_CLASS_TRANSPORT_SERVICE [0x55] V2
10. COMMAND_CLASS_CRC_16_ENCAP [0x56] V1
11. COMMAND_CLASS_SUPERVISION [0x6C] V1
12. COMMAND_CLASS_SECURITY [0x98] V1 YES
13. COMMAND_CLASS_SECURITY_2 [0x9F] V1 YES
14. COMMAND_CLASS_DEVICE_RESET_LOCALLY [0x5A] V1 YES
15. COMMAND_CLASS_APPLICATION_STATUS [0x22] V1
16. COMMAND_CLASS_POWERLEVEL [0x73] V1 YES
17. COMMAND_CLASS_FIRMWARE_UPDATE_MD [0x7A] V4 YES
18. COMMAND_CLASS_CONFIGURATION [0x70] V1 YES
19. COMMAND_CLASS_PROTECTION [0x75] V2 YES
20. COMMAND_CLASS_NOTIFICATION [0x71] V8 YES
21. COMMAND_CLASS_COLOR_SWITCH [0x33] V3 YES
22. COMMAND_CLASS_METER [0x32] V3 YES
23. COMMAND_CLASS_CENTRAL_SCENE [0x5B] V3 YES
24. COMMAND_CLASS_SENSOR_MULTILEVEL [0x31] V11 YES
25. COMMAND_CLASS_BASIC [0x20] V1 YES
Table 14 - RGBW-Control - Multichannel Command Class
Generic Device Class Specific Device Class Command Classes Description
ROOT (Endpoint 1) GENERIC_TYPE_SWITCH_MULTILEVEL
SPECIFIC_TYPE_COLOR_TUNABLE_MULTILEVEL
COMMAND_CLASS_ZWAVEPLUS_INFO [0x5E] Color Controller
COMMAND_CLASS_SWITCH_MULTILEVEL [0x26]
COMMAND_CLASS_ASSOCIATION [0x85]
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION [0x8E]
COMMAND_CLASS_ASSOCIATION_GRP_INFO [0x59]
COMMAND_CLASS_SUPERVISION [0x6C]
COMMAND_CLASS_SECURITY [0x98]
COMMAND_CLASS_SECURITY_2 [0x9F]
COMMAND_CLASS_APPLICATION_STATUS [0x22]
COMMAND_CLASS_PROTECTION [0x75]
COMMAND_CLASS_NOTIFICATION [0x71]
COMMAND_CLASS_COLOR_CONTROL [0x33]
COMMAND_CLASS_METER [0x32]
Endpoint 2, 3,4 and 5 GENERIC_TYPE_SWITCH_MULTILEVEL
SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL
COMMAND_CLASS_ZWAVEPLUS_INFO [0x5E] EP2 controlls directly Output 1 [Red]
EP3 controlls directly Output 2 [Green]
EP4 controlls directly Output 3 [Blue]
EP5 controlls directly Output 4 [White]
COMMAND_CLASS_SWITCH_MULTILEVEL [0x26]
COMMAND_CLASS_ASSOCIATION [0x85]
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION [0x8E]
COMMAND_CLASS_ASSOCIATION_GRP_INFO [0x59]
COMMAND_CLASS_SUPERVISION [0x6C]
COMMAND_CLASS_SECURITY [0x98]
COMMAND_CLASS_SECURITY_2 [0x9F]
COMMAND_CLASS_APPLICATION_STATUS [0x22]
COMMAND_CLASS_PROTECTION [0x75]
COMMAND_CLASS_NOTIFICATION [0x71]
Endpoint 6, 7, 8 and 9 GENERIC_TYPE_SENSOR_MULTILEVEL
SPECIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL
COMMAND_CLASS_ZWAVEPLUS_INFO [0x5E] EP6 reports the Voltage measured on Input 1
EP7 reports the Voltage measured on Input 2
EP8 reports the Voltage measured on Input 3
EP9 reports the Voltage measured on Input 4
COMMAND_CLASS_ASSOCIATION [0x85]
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION [0x8E]
COMMAND_CLASS_ASSOCIATION_GRP_INFO [0x59]
COMMAND_CLASS_SUPERVISION [0x6C]
COMMAND_CLASS_SECURITY [0x98]
COMMAND_CLASS_SECURITY_2 [0x9F]
COMMAND_CLASS_SENSOR_MULTILEVEL [0x31]
COMMAND_CLASS_APPLICATION_STATUS [0x22]
COMMAND_CLASS_NOTIFICATION [0x71]

11 REGULATIONS

This device complies with Part 15 of the FCC Rules

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
    • Reorient or relocate the receiving antenna.
    • Increase the separation between the equipment and receiver.
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for help.

Note: Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission's rules.

Industry Canada (IC) Compliance Notice

This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Cet appareil est conforme aux normes d'exemption de licence RSS d'Industry Canada. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer d'interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement.

12 PRODUCT DISPOSAL

This product is an integral part of the automation and therefore must be disposed of together with the latter. At the end of the product lifetime, the disassembly and scrapping operations must be performed by qualified personnel.

This product is made of various types of material, some of which can be recycled while others must be scrapped. Seek information on the recycling and disposal systems envisaged by the local regulations in your area for this product category.

As indicated by the symbol alongside, disposal of this product in domestic waste is strictly prohibited. Separate the waste into categories for disposal, according to the methods envisaged by current legislation in your area, or return the product to the retailer when purchasing a new version.

A CAUTION!

13 DECLARATION OF CONFORMITY

Hereby, Nice S.p.A., declares that the radio equipment type RGBW-Control (FGRGBW-442-US) is in compliance with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at: http://www.niceforyou.com/en/support.

Models: FGRGBW-442 Universal Remote Control, FGRGBW-442, Universal Remote Control, Remote Control, Control, Remote

File Info : application/pdf, 15 Pages, 349.45KB

PDF preview unavailable. Download the PDF instead.

IS0845A00

References

Adobe PDF Library 17.0 Adobe InDesign 20.3 (Windows)

Related Documents

Preview Nice RGBW-Control: Universal Z-Wave Plus LED Controller Manual
Comprehensive user manual for the Nice RGBW-Control, a universal Z-Wave Plus compatible controller for RGB, RGBW, and single-color LED strips, halogen lights, and other resistive loads. Includes installation, operation, advanced parameters, and technical specifications.
Preview Nice DoubleDimmer-Control: 2-Channel Lighting Dimming Manual
Comprehensive guide to the Nice DoubleDimmer-Control, a 2-channel lighting dimmer compatible with the Yubii Ecosystem. Learn about its features, installation, operation, advanced parameters, and Z-Wave specifications.
Preview Nice On/Off-Control: Remote Electrical Device Control with Z-Wave Plus
Comprehensive operating instructions for the Nice On/Off-Control, a Z-Wave Plus device for remotely switching electrical devices on and off, featuring power and energy monitoring.
Preview Nice SingleSwitch-Control: Remote Electrical Device Control and Energy Monitoring
Comprehensive guide to the Nice SingleSwitch-Control, detailing its features for remotely turning electrical devices on or off, Z-Wave Plus compatibility, installation, advanced parameters, and energy consumption monitoring.
Preview Nice SingleSwitch-Control: Remote Electrical Device Control Guide
This manual provides comprehensive instructions for the Nice SingleSwitch-Control, covering installation, operation, Z-Wave compatibility, advanced settings, and safety precautions for remotely managing electrical devices.
Preview Nice On/Off-Control2: Remote Electrical Device Control
Comprehensive guide to the Nice On/Off-Control2, a Z-Wave Plus enabled device for remotely turning electrical devices on and off. Learn about its features, installation, operation, and technical specifications.
Preview Nice Push-Control Universal Wireless Button - User Manual
Comprehensive instructions and technical specifications for the Nice Push-Control universal wireless button. Learn about its features, installation, operation, advanced parameters, and Z-Wave network integration.
Preview Nice IBT4ZWAVE BiDi-ZWave: Installation, Operation, and Technical Guide
Comprehensive guide for the Nice IBT4ZWAVE BiDi-ZWave accessory, covering installation, Z-Wave network integration, operation, technical specifications, and disposal. Enhance your Nice automation system with Z-Wave connectivity.