Kendo-45M-INSTALL
Kendo 45-M - Installation Instructions
Model K45M-XX
Please read complete instruction prior to installation and keep for future reference!

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com
Page 1 of 4 www.luminii.com

Kendo 45M

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE

Kendo 45MR
Instruction page index:
Mounting bracket installation 2 Connect to Power 3
Power feed layout guide 4 REV0.1 092582022

Kendo 45-M - Installation Instructions
Model K45M-

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician. 4. Suitable for damp locations

2. Use only with class 2 power unit

5. Surface mount only

3. 24 volts DC

6. Suitable for installation within the closet storage space

Page 2 of 4

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com w w w.luminii.com

1
Kendo 45M, w/round profile

Kendo 45M, w/angular profile

0.75"
0.74" 0.77"

0.75"
0.60" 0.75"

fixture

0.25" 4"

every 30" concealed bracket

4"
lead wires
1.1

1.1 Determine the location of where the fixture(s) will be installed. Lay the fixture(s) on the surface, and make any necessary reference marks for the concealed bracket. Make marks 4" from each end of the fixture(s) and also every 30" in between. Use the fixture profile and mounting bracket detail, for any additional details. NOTE: If mounting next to a wall, leave a 0.25" gap. To later remove if needed.
1.2 Lay the concealed bracket onto the reference mark points and secure using the provided hardware.

2

screw

0.25"

0.25"

concealed bracket

2.1 Align the mounting brackets to the marks, followed by securing each mounting bracket with 1 screws. Snap the extrusion into the mounting brackets. 2.2 To remove the extrusion from the mounting brackets, carefully insert a flat screwdriver to the bottom edge of the extrusion then pull up until the extrusion pops up.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE

REV0.1 092582022

Kendo 45-M - Installation Instructions
Model K45M-

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician. 4. Suitable for damp locations

2. Use only with class 2 power unit

5. Surface mount only

3. 24 volts DC

6. Suitable for installation within the closet storage space

Page 3 of 4

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com w w w.luminii.com

3
0.45" Female quick connect end

0.20"
Lead wire end

lead wires 3.1

0.38"

0.45"

pass through hole for power feed

Male quick connect end

Female/male adapter

3.1 If necessary make any pass through holes for wire lead/connector to the surface, depending on the power feed option. Then snap the fixture into the fixed mounting clip to secure in place. Diagram on the right side illustrates the common way of connecting multiple fixtures to each other, depending on the location of the power feed wires.

4

4.1 Follow one of the two options to connect the fixture to the power supply.

Option 1 - Secure female quick connect to male quick connect. Feed male quick connect wire through conduit to power supply.
3.1

to power supply

Option 2 - Feed wire leads to the power supply.

3.1
male quick OR
connect

to power supply wire leads

fixture

female quick connect

fixture

-24 VDC BLACK -24 VDC BLACK

+24 VDC RED

5
4.1 class II power supply

+24 VDC RED

120 VAC

24 VDC

to fixture

5.1 If necessary make any pass through holes for wire lead/connector to the surface, depending on the power feed option. Then snap the fixture into the fixed mounting clip to secure in place. Diagram on the right side illustrates the common way of connecting multiple fixtures to each other, depending on the location of the power feed wires.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE

REV0.1 092582022

Kendo 45-M - Installation Instructions
Model K45M-

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician. 4. Suitable for damp locations

2. Use only with class 2 power unit

5. Surface mount only

3. 24 volts DC

6. Suitable for installation within the closet storage space

Page 4 of 4

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com w w w.luminii.com

power supplies at the end of the run

power supply

low voltage wires

power supplies in the middle of the run

fixture 1

fixture 2
power supply low voltage wires

consecutive layout, NOT RECOMMENDED

fixture 1

fixture 2

power supply

power supply

low voltage wires fixture 1 *LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE

fixture 2

low voltage wires REV0.1 092582022

