User Manual for IMIT models including: TA5 Mechanical Thermostat, TA5, Mechanical Thermostat, Thermostat
12 nov 2024 — This is an easy-to-use MECHANICAL THERMOSTAT. It allows an accurate room temperature adjustment in the hosting room, thus meeting any users' needs as far as ...
Imit Termostat sobni TA5-B (ON/OFF, signalna lampica) IMIT - ECoS
File Info : application/pdf, 10 Pages, 625.68KB
DocumentDocument11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. The product model and code (6 digits) are printed on the sticker on the outside or the inside of the battery compartment cover. The manual may not be available in the selected language. TA5 TA5 A TA5 B TA5 C COD. 546770 COD. 546730 COD. 546710 COD. 546750 PRODUCT DESCRIPTION This is an easy-to-use MECHANICAL THERMOSTAT. It allows an accurate room temperature adjustment in the hosting room, thus meeting any users' needs as far as room comfort. CONFORMITY TO THE STANDARDS This product complies with: EN 60730-1 and subsequen revisions EN 60730-2-9 CONFORMITY TO THE GUIDELINES This product complies with: LVD 2014/35/EU We usCelacsosoEkriPesI (t+o1e%n)suEreUt8h1a1t/2w0e1g3ive you the best experience on our website. If you continue to use this site we will assume that you are happy with it. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 1/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. It is recommended to install the appliance strictly in compliance with all safety and law provisions in force. Before connecting the thermostat, make sure that the supply voltage of the UNIT TO BE CONTROLLED (boiler, pump, air-conditioning system, etc.) is NOT CONNECTED and that it matches the indication given inside the appliance (250V~ max). ( g.5) In case of repeated malfunctioning, please call our Technical Service. Do not tamper for any reason with any part of the thermostat. FIG. 5 TECHNICAL SPECIFICATIONS Maximum capacity of the contacts 16(2,5)A/250V~ Type of action 1B Temperature regulation range 5°÷30°C Temperature differential 0,4K÷0,8K Output switching contacts Degree of protection IP 20 Insulation class Double insulation Pollution degree 2 Storage temperature 0°÷50°C WeRuasteecdoimokpieuslsteoweintshusrteanthdavtowlteaggeiv4ekyVou the best experience on our website. If you continue to use this site we Installation to the wall will assume that you are happy with it. Temperature rate of change 1K/15min. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 2/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. THERMOSTAT CONTROL KEYS 1 = Temperature setting knob ( g. 1) 2 = Warning lamp (TA5-A, TA5-B, TA5-C) 3 = ON/OFF switch (TA5-B) or SUMMER/WINTER switch (TA5-C) OPTIONAL ACCESSORIES Sub-base tting = cod. 004095 ( g.3) FIG. 1 FIG. 3 We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we Special ( g.4) tting for temperature rangwe irlel astsrsicutmioensthoartfoyrotuhaerteemhappepraytwuriethloitc. k at a pre-set value. = cod. 000071 https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 3/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. INSTALLATION FIG. 4 PLACEMENT OF THE THERMOSTAT FIG. 6 Install the thermostat away from heat sources (radiators, sunrays, and kitchens) and away from doors/windows, at approx. 1,5 m height from the oor. ( g.6) INSTALLATION AND WIRING CONNECTIONS A) In case the thermostat shall be installed either in a round built-in box (having distance between centres equal to 60mm), or on an uneven wall surface or in other particular locations, it is recommended to use a subbase tting (see paragraph "Optional Accessories "). Fix the tting to the wall through two holes other than the ones marked as B-B, which are exclusively provided for the thermostat installation. ( g.7) We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 4/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. FIG. 7 B) Remove the front cover from the thermostat base by releasing the provided clip ( g.8), then x it to the wall (or to the sub-base tting) through the provided holes ( g.9) and tighten it by means of suitable screws having max of 3,5 mm. FIG. 8 We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 5/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. FIG. 9 C) Thread the power supply wires through the slot in the base and connect them to the terminals as per the wiring diagram sketched inside the appliance. Snap the front cover back. ( g.10) FIG. 10 DESCRIPTION OF CONTROLS AND OPERATION TURNING THE THERMOSTAT ON AND OFF On TA5-B, put the switch onto the "ON" position to start the equipment or onto the "OFF" to turn it off. ( g.12) We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 6/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. FIG. 12 TEMPERATURE SETTING When the appliance is connected and the electric power is switched on, set the desired room temperature simply by turning the temperature-adjusting knob to the corresponding value on the graduated scale. ( g.11) FIG. 11 TEMPERATURE RANGE RESTRICTION AND TEMPERATURE LOCK WARNING: THE TEMPERATURE RANGE RESTRICTION AND TEMPERATURE LOCK OPERATIONS MUST BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY. TEMPERATURE RANGE RESTRICTION WeRuesme ocvoeokthieesfrtoonetncsouvreer tfhroamt wtehegtivheerymooustthaet bbaesset beyxpreelreieansicnegothneopurrowviedbesditceli.pI.f(yogu.8c) ontinue to use this site we will assume that you are happy with it. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 7/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. FIG. 8 Insert the provided tting (see paragraph "Optional Accessories ") in the knob at the desired limit points (min. and max.) according to the corresponding values marked on the knob body. Make sure that the metal retainer remains in its correct position between the min. and max. limit points. ( g.14); Snap the front cover back. FIG. 14 TEMPERATURE LOCK Position the knob to correspond with the desired temperature value, then separate the base from the cover by pressing the appropriate retaining tooth. ( g.8) Insert the two special accessories (see chapter "Accessories upon Request") on the sides of the metal stop in order to prevent the handle from moving ( g.15); put the lid back on the product. We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 8/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. FIG. 15 SUMMER/WINTER SWITCH On TA5-C, put the switch onto the position to set up the "summer" operation mode (air conditioning system), or onto the " " position to set up the "winter" operation mode (heating system). ( g.13 set up the "winter" operation mode (heating system). ( g.13) " position to FIG. 13 PROBLEM SOLVING Problem The system does not start WePuossesciboloekcieasustoe ensure that we give you the best experience on our website. If you continue to use this site we Wrong wiring will assume that you are happy with it. The set room temperature has been already reached Switch on OFF position Wrong setting of summer/winter switch https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 9/10 11/12/24, 8:59 AM TA5 - TA5 A - TA5 B - TA5 C - Manuali - Imit Control System s.r.l. Solution Check if the wiring connections to the thermostat terminals were carried out as per wiring diagram Increase or reduce the set temperature value according to the system application (heating/air-conditioning system) Put switch onto ON position Make sure the switch is on position (heating system) or o position (air conditioning system) Problem The ambient temperature does not correspond to the temperature set on the thermostat Possible cause Incorrect positioning of the thermostat within the room Air draughts coming from the electrical wires conduit Solution Follow the instructions of paragraph "Placement of the thermostat" Seal the conduit to prevent warm or cold air draughts IMIT CONTROL SYSTEM s.r.l. Via Varallo Pombia,19 Castelletto Sopra Ticino (NO) Tel (+39)0331941600 Fax (+39)0331973100 P.IVA IT02223920063 www.imit.it - info@controlsys.it We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. https://man.imit.it/en/ta5-ta5-ta5-b-ta5-c/ 10/10