User Guide for UBIQUITI models including: UF-LOCO, Fiber Gigabit Passive Optical Network Unit, UF-LOCO Fiber Gigabit Passive Optical Network Unit, Gigabit Passive Optical Network Unit, Optical Network Unit, Network Unit
UBIQUITI UFLOCO- Unidad de Red Optica UFIBER ONU/ 1 Pto WAN
File Info : application/pdf, 16 Pages, 899.08KB
DocumentDocumentMachine Translated by Google UF-LOCO Quick Start Guide Package content UFiber loco wall mount bracket Screws (qty: 4) Screw plugs (qty: 4) power adapter Micro-USB* (5 V, 1 A) * Included only in the single package of the UF-LOCO. System Requirements Linux, Mac OS X o Microsoft Windows 7/8/10 Web browser: Google Chrome (other browsers may have limited functionality) Before starting Designing your first deployment of a GPON network requires specific planning and knowledge. For more information on designing and installing a GPON network, including important considerations and best practices, see: ubnt.link/UFiber-GPON-Getting-Started ubnt.link/Designing-a-GPON-Network To learn more about how to configure UFiber devices for the first time to allow the Optical Network Unit (ONU) LAN ports to provide Machine Translated by Google connectivity, see: ubnt.link/UFiber-Initial-Configuration UF-LOCO Quick Start Guide hardware description Reset button The Reset button has two functions for the UF-LOCO: Reset Quickly press and release the Reset button. All three signal LEDs will flash amber. Restore Factory Default Settings: Press and hold the Reset button for more than five seconds. Puerto PON The GPON SC/APC port supports 2.488 Gbps downstream and 1.244 Gbps upstream WAN connections. power port Machine Translated by Google Micro-USB power adaUptFe-rLcOoCnOneQctusictok tShtiasrpt oGrut itdoesTuhpeply power. ethernet power The RJ45 Ethernet LAN port supports 10/100/1000 Mbps connections and 24V passive PoE to power the device. LED the Ethernet disabled No ethernet connection White With ethernet connection LED signal indicators disabled Start Signal strength: low ÿ -28 dBm Signal strength: good ÿ -25 dBm Signal strength: strong ÿ -11 dBm Signal strength: too low < -28 dBm Check the quality of the fiber connection and calculate the total optical loss of the optical splitters. Signal strength: too strong ÿ -8 dBm Add an optical splitter or a 5 or 10 dB optical attenuator. No signal Machine Translated by Google UF-LOCO QuwCicohkrekScinktagtrhtpeGrofuipbiedererlycm.aabkleessaunred tchoenOneLcTtoisrs and no authority The UF-LOCO has not been authorized or it cannot communicate with the OLT. Check passwords and OLT settings. Power LEDs disabled White Off Switched on hardware installation wall mount 1. Machine Translated by Google UF-LOCO Quick Start Guide 2. Machine Translated by Google UF-LOCO Quick Start Guide 3. Machine Translated by Google UF-LOCO Quick Start Guide 4. Machine Translated by Google UF-LOCO Quick Start Guide fiber connection WARNING: Never look directly into the ends of the fiber or modules. The light they emit can cause eye damage. WARNING: Until ready to use, keep fiber patch cables and modules covered with the included protective caps to ensure connections remain clean. WARNING: DO NOT connect the device directly to a UFiber GPON module (UF-GP-B+ or UF-GP-C+). Doing so will damage the optics of the device. Make sure that the signal level received by the device never exceeds -8 dBm. Use a UFiber PLC splitter to add attenuation as needed. Machine Translated by Google UF-LOCO Quick Start Guide LAN connection Power connection Machine Translated by Google UF-LOCO Quick Start Guide O Note: The airCube provides Wi-Fi connectivity with a PoE gateway, making it the ideal complement to the UF-LOCO in CPE installations. O WARNING: The port switch must meet the power specifications listed in this quick start guide. Machine Translated by Google UF-LOCO Quick Start Guide Access to the configuration interface 1. Make sure your computer (or other host system) is connected to the device. 2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet. 3. Launch the web browser. Type http://192.168.1.1 in the address field. Press Enter (PC) or Return (Mac). 4. Enter ubnt in the Username and Password fields. Click Login. Machine Translated by Google UF-LOCO Quick Start Guide Customize the settings as needed. For more information, see UFiber's resources, which are available at: http://ubnt.link/UFiber-Support OLT Compatibility Profiles The device is compatible with most major OLT (Optical Line Terminal) brands and offers four compatibility profiles. By default, the device is set to Profile 1 UFiber OLT from Ubiquiti. For other brands, manually select Profile 2, 3 or 4. 1. Log in to the UFiber configuration interface. 2. Go to Settings . Machine Translated by Google 3. On the Network screeUn,Fcl-iLckOthCeOSyQstuemicktabS.tart Guide 4. Select the appropriate profile from the OLT Profile dropdown menu: Profile 1 (Profile 1) OLT UFiber from Ubiquiti Profile 2 (Profile 2) Other brands Profile 3 (Profile 3) Other brands Profile 4 (Profile 4) Other brands Note: For more information, visit: https://ubnt.link/Supported-3rd PartyOLTs 5. Click Save Changes. Machine Translated by Google The device will automaticUaFlly-LreOboCoOt wQithutihceknSewtaprrtoGfileu.ide specs Dimensions Weight Interfaces de red Network interface speeds control interface Normal Optical Power Range feeding method Power supply maximum power consumption Supported voltage range processor specifications memory information Button Operating temperature operating humidity Certifications UF-LOCO 76,5 x 76,5 x 26,4 mm (3,01 x 3,01 x 1,04") 77 g (2,72 oz) (1) WAN GPON SC/APC (1) LAN Ethernet RJ45 (1) GPON WAN, ITU G.984, 2.488 Gbps down, 1.244 Gbps up (1) GbE LAN, 10/100/1000 Mbps Ethernet and bandwidth POUNDS TX (Clase B+): 1,5 a 5 dBm RX: -28 a -8 dBm Micro-USB: 5 V; 1 A 24V passive PoE (outlets: +4.5; -7.8) Micro-USB power adapter*: 5V; 1A 3,5W 4.7 and 5.3 V MIPS 32, 240 MHz 128 MB DDR3 (1) Reset -10° C to 45° C (14° F to 113° F) 10 to 90% non-condensing CE, FCC, IC * Included only in the single package of the UF-LOCO. safety instructions 1. Read, follow and save these instructions. 2. Pay attention to all warnings. 3. Only use the devices or accessories indicated by the manufacturer. WARNING: To reduce the risk of fire or electric shock, do not expose the Machine Translated by Google product to rain or moisture. UF-LOCO Quick Start Guide WARNING: Do not use this product in a location where it may be submerged in water. WARNING: Avoid using this product during a lightning storm. There is a remote possibility of an electrical discharge caused by lightning. WARNING: CLASS 1 LASER PRODUCT: Do not look at the ends of the fiber optic cable or SFP modules when the converters are powered on. electrical safety information 1. It is mandatory to comply with the current, frequency and voltage requirements indicated on the manufacturer's label. Connection to a power source other than those specified may result in malfunction, equipment damage, or fire hazard if limitations are not followed. 2. This equipment contains no operator-serviceable parts. Only a qualified service technician should provide services. limited warranty ui.com/support/warranty The limited warranty requires arbitration to resolve disputes on a case-by-case basis and, where appropriate, specifying arbitration instead of jury trials or class actions. Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference, including interference that may may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to protect the equipment, to the extent possible, from harmful interference when it is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Machine Translated by Google ISED from Canada UF-LOCO Quick Start Guide CAN ICES-3(A)/NMB-3(A) Australia and New Zealand Warning: This equipment complies with Class A of CISPR 32. In a residential environment, it may cause radio interference. CE marked The CE marking of this product indicates that the product complies with all applicable directives. WEEE Compliance Statement Declaration of conformity online resources © 2021 Ubiquiti Inc. All rights reserved.