User Guide for ZYXEL models including: PLA6457, G.hn Wave 2 Powerline Pass-Through Gigabit Ethernet Adapter, PLA6457 G.hn Wave 2 Powerline Pass-Through Gigabit Ethernet Adapter

PLA6457 - Geizhals Static Content

8 ore fa — The PLA6457 in this user's guide may be referred to as the “PLA” in this guide. ... This field displays the Ethernet adapter MAC (Media Access Control) ...


File Info : application/pdf, 50 Pages, 947.88KB

PDF preview unavailable. Download the PDF instead.

abbd4b77be8f51c81c3975bedfa3522f3d78
User's Guide
PLA6457
G.hn Wave 2 Powerline Pass-through Gigabit Ethernet Adapter

Default Login Details

Default Network Name LAN IP Address
Default Password

G.hn Network http://DHCP-assigned
IP FLYPIG2400

Version 1.0 Ed. 2, 08/2021

Copyright © 2021 Zyxel and/or its affiliates. All Rights Reserved.

IMPO RTANT! READ C AREFULLY BEFO RE USE. KEEP THIS G UIDE FO R FUTURE REFERENC E.
Screenshots and graphics in this book may differ slightly from what you see due to differences in release versions or your computer operating system. Every effort has been made to ensure that the information in this manual is accurate.
Re la te d Do c um e nta tio n
· Quick Start Guide The Quick Start Guide shows how to connect and set up the PLA in your network.
· More Information Go to suppo rt.zyxe l.c o m to find other information on the PLA.
PLA6457 User's Guide
2

Do c um e nt C o nve ntio ns

Wa rning s a nd No te s
These are how warnings and notes are shown in this guide.

Wa rning s te ll yo u a b o ut thing s tha t c o uld ha rm yo u o r yo ur de vic e .
Note: Notes tell you other important information (for example, other things you may need to configure or helpful tips) or recommendations.

Synta x C o nve ntio ns
· The PLA6457 in this user's guide may be referred to as the "PLA" in this guide. · Product labels, screen names, field labels and field choices are all in bo ld font.

Ic o ns Use d in Fig ure s
Figures in this user guide may use the following generic icons. The PLA icon is not an exact representation of your device.

PLA

Router

Laptop Computer

Internet

Fax Printer

Printer

Desktop

Smart TV

Set-top Box

PLA6457 User's Guide
3

Table of Contents
Ta b le o f C o nte nts
Do c um e nt C o nve ntio ns ......................................................................................................................3
Ta b le o f C o nte nts .................................................................................................................................4
Pa rt I: Use r's G uide ............................................................................................ 6
C ha pte r 1 Intro duc ing the PLA .............................................................................................................................7
1.1 Overview ........................................................................................................................................... 7 1.1.1 G.hn Standard ......................................................................................................................... 8
1.2 LEDs .................................................................................................................................................... 8 1.3 Standby Mode .................................................................................................................................. 9 1.4 Ways to Manage the PLA ................................................................................................................ 9 1.5 Expand Your Network with the PLA ................................................................................................ 9 1.6 Security ............................................................................................................................................ 10
1.6.1 Domain Name ....................................................................................................................... 10 1.6.2 Setting Up Encrypted Pairing ............................................................................................... 10 1.7 Multiple Networks ........................................................................................................................... 11
C ha pte r 2 RESETa nd ENC RYPTButto ns...............................................................................................................12
2.1 ENCRYPT Button .............................................................................................................................. 12 2.2 Adding Devices to a G.hn Network ............................................................................................. 12 2.3 Multiple Separate G.hn Networks ................................................................................................. 14 2.4 RESET Button .................................................................................................................................... 15
Pa rt II: Te c hnic a l Re fe re nc e ........................................................................... 16
C ha pte r 3 We b C o nfig ura to r...............................................................................................................................17
3.1 Overview ......................................................................................................................................... 17 3.1.1 G.hn Network Security .......................................................................................................... 18
3.2 System Login .................................................................................................................................... 18 3.3 G.hn Settings ................................................................................................................................... 19 3.4 IP Settings ......................................................................................................................................... 20 3.5 Ethernet Settings ............................................................................................................................. 22
PLA6457 User's Guide
4

Table of Contents 3.6 Device Settings ............................................................................................................................... 23 3.7 Multicast Settings ............................................................................................................................ 25 3.8 Log File Settings ............................................................................................................................... 27 C ha pte r 4 G .hn Ne two rk Se tup Tuto ria l .............................................................................................................29 4.1 Overview ......................................................................................................................................... 29 4.2 Important Terms .............................................................................................................................. 29 4.3 Accessing Your PLA ........................................................................................................................ 29 4.4 Adding a PLA .................................................................................................................................. 30 4.5 Setting Up a New Network with a New PLA ................................................................................ 32 C ha pte r 5 Tro ub le sho o ting ..................................................................................................................................34 5.1 Power and Light Problems ............................................................................................................. 34 5.2 Web Configurator Problems .......................................................................................................... 35 5.3 Powerline Problems ........................................................................................................................ 36 5.4 ENCRYPT Button Problems ............................................................................................................. 36
Appendix A Customer Support ....................................................................................................... 38 Appendix B Legal Information ......................................................................................................... 44
Inde x ...................................................................................................................................................47
PLA6457 User's Guide
5

PA RT I
Use r's G uide
6

C HA PTER 1 Intro duc ing the PLA
1.1 O ve rvie w
This chapter introduces the main applications and features of your Zyxel G.hn Powerline adapter, which is called "PLA" in this guide. The PLA plugs into an ordinary power outlet to easily extend a cable or DSL broadband connection or existing Ethernet (LAN) network to any other electrical outlet in any room of a house, all without the need for any new cabling. The AC power pass-through feature allows you to unplug electrical device from a power socket, plug the PLA into the socket and then plug the electrical device back into the PLA. The power plug varies depending on your region. In the following diagram, the first PLA (PLA1) connects to an Internet gateway such as a modem and plugs into an ordinary power outlet. The second PLA (PLA2) plugs into another power outlet and connects to a computer. PLA1 and PLA2 communicates through ordinary power lines. Fig ure 1 PLA Application

PLA2

PLA1

Refer to your Quick Start Guide for hardware connection information.

In this User's Guide the electrical wiring network is referred to as the "G.hn Network".

Table 1 PLA Features
PO RT/ FEATURE Number of Gigabit Ethernet ports AC Pass-Through Encrypt Button Reset Button Maximum PHY Rate over Powerline

PLA 6 4 5 7 1
YES YES YES 1200 Mbps

PLA6457 User's Guide
7

Chapter 1 Introducing the PLA
1.1.1 G .hn Sta nda rd
G.hn is a specification for home networking devices that operates over power lines. G.hn specifies the point-to-point security inside a domain, which means that each pair of transmitter and receiver uses a unique encryption key which is not shared by other devices in the same domain. Devices can securely communicate with each other at high data transfer rates. The PLA uses 128-bit Advanced Encryption Standard (AES) to ensure safe transfer of information.
1.2 LEDs
The following section describes the lights (LEDs) on the PLA. The following figure is the front panel of the PLA. Use the lights to determine if the PLA is behaving normally or if there are some problems on your G.hn Network. Fig ure 2 PLA Lights

The following table describes the behavior of the lights on the PLA.

Table 2 LEDs

LIG HTS

IC O N

POWER

C O LO R Green

STA TUS On Blinking

POWERLINE

Off

Green

On

Amber

Red

Green/ Amber/ Red

Blinking Off

DESC RIPTIO N
The PLA is on and receiving power.
The power LED blinks when it is in standby mode that allows you to save on power during periods of inactivity. Refer to Section 1.3 on page 9 for details on this feature.
The PLA is not receiving power.
The PLA detects another PLA and can transmit and/or receive data at greater than 80 Mbps.
The PLA detects another PLA and can transmit and/or receive data between 20 ­ 80 Mbps.
The PLA detects another PLA and can transmit and/or receive data between 0 ­ 20 Mbps.
The PLA is communicating with another PLA. Data is being transmitted and/or received.
The PLA does not detect another PLA.

PLA6457 User's Guide
8

Chapter 1 Introducing the PLA

Table 2 LEDs (continued)

LIG HTS

IC O N C O LO R

ENCRYPTED PAIRING

Green

STA TUS On

Blinking

ETHERNET

Green

Off On Blinking

Off

DESC RIPTIO N
It indicates the PLA is connected to another device in encrypted pairing mode. The transmitter and receiver uses a unique encryption key for point-to-point security.
It indicates the PLA is trying to connect with another device in encrypted pairing mode.
Encrypted pairing mode is disabled.
The 10/100/1000 Mbps Ethernet connection is up.
The PLA is communicating with a networking device connected to it.
The PLA does not detect any devices connected to its ETHERNET port.

1.3 Sta ndb y Mo de
You can set your PLA to save on power when there is no Ethernet connection or activity. Use the Web Configurator's Ethe rne t screen to set the period of time when the PLA will go into standby mode. Refer to Section 3.5 on page 22 for details on this feature. The PLA's power LED blinks signaling that it is going into standby mode. The Ethernet LED, Encrypted Pairing LED, and Powerline LED are turned off in standby mode.
Note: While in standby mode, you cannot use the RESETand ENC RYPTbuttons. To enable the RESETand ENC RYPTbuttons again, you have to connect the PLA's Ethernet cable to a computer/notebook or modem/router first. The PLA wakes up from standby mode and you can start using the RESETand ENC RYPTbuttons.
1.4 Wa ys to Ma na g e the PLA
Use the ENC RYPTbutton to add PLAs to your G.hn Network. See Chapter 2 on page 12 for instructions on using the ENCRYPT feature.
Use the Web Configurator to manage the PLA. See Chapter 3 on page 17 for instructions on using the Web Configurator.
1.5 Expa nd Yo ur Ne two rk with the PLA
Your network can be further expanded by plugging additional PLAs into other outlets in your home and connecting other computers or network devices (for example, a Smart TV) to them.

PLA6457 User's Guide
9

Chapter 1 Introducing the PLA Fig ure 3 Expand Your Network with the PLA

Connect your first PLA (PLA1) to an Internet gateway such as a modem and plug it into an ordinary power outlet in your home. Plug a second PLA (PLA2) in Room1 into another power outlet and connect a computer to the PLA for Internet access. Plug a third PLA (PLA3) in Room2 into another power outlet and connect a Smart TV to the PLA for streaming video. Plug a fourth PLA (PLA4) in Room3 into another power outlet and connect a Smart TV to the PLA for streaming video.

1.6 Se c urity
Since your G.hn Network may extend outside your premises, it is important to set up security on your PLA.

1.6.1 Do m a in Na m e

You can use the domain name to identify your PLA in the G.hn Network.

Table 3 Domain Name Summary

IDENTITY

DESC RIPTIO N

Domain Name

Your PLA follow the G.hn standard and is shipped with the same domain name "G.hn Network". Change the domain name through the Web Configurator or RESETbutton to create a private network. See Section 3.4 on page 20.

1.6.2 Se tting Up Enc rypte d Pa iring
The ENCRYPT feature automatically sets up encrypted pairing on your G.hn Network using the ENC RYPT button (see Section 2.1 on page 12 for more information). It involves authenticating the identity of the two PLAs to be paired and encrypting the link.
Alternatively, use the Web Configurator to set up encrypted pairing on the PLA. Although the PLA is a "plug-and-play" network expanding solution there are several reasons for enabling security on the G.hn Network in your home.
1 It is easy and only requires you to change a network name.

PLA6457 User's Guide
10

Chapter 1 Introducing the PLA
2 It is a good idea to ensure privacy of your communication. When you use the PLA and other PLAs, the electrical wiring in your home becomes an extension of your Ethernet network. Your network traffic flows freely within the electrical circuit of your home and is bounded in most cases by a power meter. Without encrypted pairing (security) your information is accessible to anyone using a PLA on the same electrical circuit. In some cases, a circuit can be shared by more than one household. To prevent compromising your network security, you can create a private network. A private network uses a Do ma in Na m e to make sure that only permitted PLAs can communicate in your network. See Section 3.4 on page 20 for information on setting up a private network.
3 You may need to change the Do m a in Na m e to create multiple G.hn Network. See the next section for more information on how to set up a multiple network.
1.7 Multiple Ne two rks
Multiple G.hn Networks can coexist on a single electrical circuit. You might want to implement multiple G.hn Networks in a small office environment where you have two independent Ethernet networks. 1 Connect one PLA to a router or switch on the first Ethernet network and assign a Do m a in Na me (for example "Tom's Network") to this PLA (see Section 3.3 on page 19 for more information). Add additional PLAs to your network by plugging them into your Powerline outlets and assigning them "Tom's Network". This completes the configuration of your first G.hn Network. 2 Connect another PLA to a router or switch on the second Ethernet network and assign a different Do ma in Na me (for example "Alice's Network") to this PLA. Again, add additional PLAs and assign them "Alice's Network". You now have two private networks on your Powerline circuit. Information is not shared between the two networks as only PLAs with the same criteria for this Do m a in Na m e can communicate with each other.
PLA6457 User's Guide
11

C HA PTER 2 RESETa nd ENC RYPTButto ns

2.1 ENC RYPTButto n

The ENC RYPTbutton allows you to set up a secure Powerline connection with other G.hn compliant PLAs which also support the ENCRYPT feature. No other Powerline setting changes are required to connect.

The following table summarizes the actions that occur when the ENC RYPTbutton is pressed for specific lengths of time.

Table 4 ENCRYPT

TIME

AC TIO N

2 to 5 seconds

Join an existing G.hn Network by sharing the same network name as other devices on the network.

ENC RYPTED PAIRING LIG HT BEHAVIO R
The Encrypted Pairing ( ) light blinks until the device is connected. This may take a minute.

PO WERLINE LIG HTBEHAVIO R
The Powerline ( ) light turns on if your device is connected to another PLA or a G.hn Network.

Note: The domain name is unknown when you use the ENC RYPTbutton.

2.2 Adding De vic e s to a G .hn Ne two rk

You can connect a number of PLAs on a G.hn Network, but you can use the ENC RYPTbutton on only two PLAs at a time.
Place a PLA close to another PLA so you have time to set up each one. After you set up the first PLA, you have 120 seconds to set up the second PLA.
Note: Your PLA must be connected to a networking equipment for the ENC RYPTbutton to work. Refer to Section 1.3 on page 9 for more details.
Follow the steps below to set up your G.hn Network:

1 Press the ENC RYPTbutton at the side of your PLA for 2 to 5 seconds. The encrypted pairing ( blink as the PLA tries to set up a connection with a new random domain name.

) light will

PLA6457 User's Guide
12

Chapter 2 RESET and ENCRYPT Buttons

Fig ure 4 ENCRYPT Connection Procedure

PLA

PLA

press 2 ­ 5 seconds

press 2 ­ 5 seconds

within 2 minutes
Note: Check the lights on the two PLAs. The encrypted pairing ( ) and Powerline ( ) lights should be on while the devices are connecting. Wait for about 2 minutes while your PLAs connect.
If the encrypted pairing ( ) light does not blink when you press ENCRYPT, you have probably pressed the ENCRYPT button for too long. Try pressing the ENCRYPT button again for 2 to 5 seconds.
If the Powerline ( ) lights on both PLAs do not light up, the PLAs are not connected. Repeat step 1 in this section. If that does not work, see Troubleshooting in Section 5.4 on page 36 for suggestions.
2 To add more PLAs to your network, use any PLA (A or B) you have connected to set up a connection with the PLAs you want to connect (C and D).
3 Press the ENC RYPTbutton on both PLAs (A and C , or B and C ) for 2 to 5 seconds to add PLA C . This must be done within 2 minutes (120 seconds) of pressing the ENC RYPTbutton on the PLA.
4 Press the ENC RYPTbutton on both PLAs (A and D, B and D, or C and D) for 2 to 5 seconds to add PLA D. This must be done within 2 minutes (120 seconds) of pressing the ENC RYPTbutton on the PLA.
5 After pairing them, unplug the PLAs and plug them where you want to extend your network.

PLA6457 User's Guide
13

Chapter 2 RESET and ENCRYPT Buttons Fig ure 5 Adding More PLAs to Your Network

B

A

A OR B

A OR B OR C

C

D

This sets up your G.hn Network between your PLAs.

2.3 Multiple Se pa ra te G .hn Ne two rks

You can use the ENC RYPTbutton to create multiple separate G.hn Networks by using the ENC RYPT button on different pairs of PLAs.

1 Press the ENC RYPTbutton on PLAs E and F for 2 to 5 seconds. This must be done within 2 minutes (120 seconds) of pressing the ENC RYPTbutton on the first PLA.

2 Wait for about one minute while PLAs E and F connect.

3 Now pair two different PLAs. Press the ENC RYPTbutton on PLAs G and H for 2 to 5 seconds and within 2 minutes of each other.

4 Wait for about one minute while PLAs G and H connect.

5 When the encrypted pairing ( connected.

) and Powerline (

) lights shine steadily, the devices are

PLA6457 User's Guide
14

Chapter 2 RESET and ENCRYPT Buttons

Fig ure 6 Two Separate G.hn Networks

E

F

G H

If the Powerline ( ) lights on both PLAs do not light up, the PLAs are not connected. Repeat the connection process, making certain you press the ENC RYPTbuttons for the correct time and within 2 minutes of each other. If that does not work see Section 5.4 on page 36 for suggestions.
See Troubleshooting in Chapter 5 on page 36 for suggestions on problems with the ENC RYPTbutton and the lights.

2.4 RESETButto n

The RESETbutton allows you to reset the PLA to the factory defaults. It also unpairs the PLA from a network.

The following table summarizes the actions that occur when the RESETbutton is pressed for specific lengths of time.

Table 5 RESET

TIME

AC TIO N

10 to 15 seconds

Clear all user-entered configuration information and return the device to its factory defaults.

PO WER LIG HTBEHAVIO R

PO WERLINE LIG HTBEHAVIO R

The power ( ) light blinks and The Powerline ( ) light turns

then shines steadily.

off when it disconnects from the

G.hn Network.

Note: The domain name is unknown when you use the RESETbutton. You can then pair the PLA to a different network.
See Troubleshooting in Chapter 5 on page 36 for suggestions on problems with the ENC RYPTbutton and the lights.

PLA6457 User's Guide
15

PA RT II
Te c hnic a l Re fe re nc e
16

C HA PTER 3
We b C o nfig ura to r
3.1 O ve rvie w
This chapter shows you how to use the Web Configurator to secure and manage on your G.hn network.
The Web Configurator is an HTML-based management interface that allows easy PLA setup and management through Internet browser. Use a browser that supports HTML5, such as:
· Microsoft Edge · Internet Explorer 11 or later · Google Chrome 34.0.1847.131 or later · Mozilla Firefox 29.0.1 or later · Opera 21.0 or later · Safari 5.1.7 or later The recommended minimum screen resolution is 1024 by 768 pixels. In order to use the Web Configurator you need to allow:
· Web browser pop-up windows from your device. Web pop-up blocking is enabled by default in some browsers.
· JavaScript (enabled by default). · Java permissions (enabled by default). The PLA is designed as a plug-and-play network expanding solution. This means that once you complete your hardware connections, the PLAs in your network (without additional configuration) are able to communicate with each other by sending and receiving information over your home's electrical wiring (A).
Fig ure 7 Example Network Setup

A

PLA

PLA

All G.hn compliant PLAs within range can join your network. The range varies depending on the quality of your home's wiring.

PLA6457 User's Guide
17

Chapter 3 Web Configurator
See Section 3.1.1 on page 18 for more information on enhancing your G.hn network security.
3.1.1 G .hn Ne two rk Se c urity
When the PLAs communicate with each other, they use encryption to protect the information that is sent in the G.hn network. Encryption is like a secret code. If you do not know the secret code, you cannot understand the message. The G.hn standard uses 128-bit AES (Advanced Encryption Standard) to safely transmit data between PLAs. For the PLAs to communicate with each other they all need to use the same network name (or Do m a in Na me ). This network name allows the PLAs to understand the encrypted information sent in the G.hn network. By default the PLAs are all configured with the network name G.hn, this allows you to simply plug the devices in and not worry about setting up security. If you want to enhance the security on your G.hn network, you can change the network name on the PLAs you want to allow to communicate in your G.hn network.
3.2 Syste m Lo g in
1 Make sure your PLA hardware is properly connected to a router with DHCP server (refer to the Quick Start Guide). Note down the DHCP-assigned IP address for your PLA.
2 Start your web browser. 3 The PLA is a DHCP client by default. Type "http://DHCP-assigned IP address" in the Lo c a tio n or Addre ss
field. Press [ENTER]. Your computer must be in the same subnet in order to access this website address. 4 The following screen appears.
Fig ure 8 Web Configurator: Login
5 Enter the default password as shown on the cover page. Click O k to log into the Web Configurator to manage the PLA directly.
PLA6457 User's Guide
18

Chapter 3 Web Configurator
3.3 G .hn Se tting s
Your PLA conforms to the G.hn (G.hn) standard for sending data over electrical power wiring in your home. Use the G .hn screen to change the basic settings of the PLA. Click G .hn to access this screen. Fig ure 9 G.hn Screen

The following table describes the labels in this screen.

Table 6 G.hn Screen

LA BEL

DESC RIPTIO N

Basic Settings MAC address
Device ID

This field displays the MAC address of your PLA. The MAC address of your PLA can be found by looking at the label on your device. It consists of six pairs of hexadecimal characters (hexadecimal characters are "0 ­ 9" and "a ­ f"). In the case of the PLA, this label is on the back of the device.
Every PLA acts as the DO MAIN_MASTER by default before connecting to another PLA. The default De vic e ID is 1.

After you press the ENC RYPTbutton to connect your PLA to another PLA, the two PLAs will determine which one acts as the DO MAIN_MASTER. This field displays 1 when your PLA is the DO MAIN_MASTER. It displays 2 when your PLA is the END_PO INT(see the Fo rc e no de Type field in this table for more information).

Note: When none of the PLA works as the DO MAIN_MASTER in the network, you can manually configure your PLA as the END_PO INTby selecting END_PO INTin the Fo rc e no de Type field. The De vic e ID will be set to 0.

PLA6457 User's Guide
19

Chapter 3 Web Configurator

Table 6 G.hn Screen (continued)

LA BEL Domain Name

DESC RIPTIO N
The default domain name of the PLA is "G.hn Network". The PLAs use the same domain name to recognize and communicate with each other over the powerline network. If you change the domain name of one device on the network, it will no longer be recognized as part of that network.

If you change the domain name, make sure you change the domain name for all of the PLAs that you want to be part of your powerline network.

The domain name can be from 8 to 64 characters in length, using "A"­"Z", "a"­"z", "0"­"9"; spaces are not allowed.
Force node Type This field forces the PLA to have a particular role (END_PO INTor DO MAIN_MASTER).

Node type

· Select DO MAIN_MASTER if your PLA connects to a router or AP. · Select END_PO INTif your PLA connects to the end device (for example, computer). · It is recommended to select the default setting AUTO MATIC for automatic role detection of
the PLA.
Shows the current role of the device based on your selection in the previous field.

Note: Node type change can take some time, click O k after making any changes in the Fo rc e no de Type field. You may need to refresh your webpage.

G.hn profile

This field selects the G.hn profile of all PLAs to apply in the G.hn network (PLC 100 MHz MIMO Bo o st, PLC 100 MHz Bo o st).

· Select PLC 100 MHz MIMO Bo o st (multiple input multiple output) when the PLA connects to a 3-prong electrical socket in your home. Multiple electrical paths between PLAs in the same G.hn network are available and sending and receiving of data is through all 3 wires (power, neutral, and ground).
· Select PLC 100 MHz Bo o st when the PLA connects to a 2-wire electrical socket. A single electrical path between PLAs in the same G.hn network is available and sending and receiving of data is through the 2 wires (power and neutral).

Encryption Configuration

Encryption is ENABLED

Pairing password Use this password for authentication. Enter a custom password to manually create a secure connection with another PLA. The password can be up to 30 alphanumeric and special characters. Then click C ha ng e .

Automatic configuration

Before connecting, make sure the other PLA is using the same Pa iring pa sswo rd. Then click Pa ir to allow connection with another PLA in the same power circuit. Wait a few minutes for the connection, you may need to refresh your webpage to update the status.

Available Connections

This field list all the available G.hn connection details (remote node De vic e ID, MAC a ddre ss, Phy Tx (Mb ps) transmission and Phy Rx (Mb ps) reception physical speeds. Phy Tx (Mb ps) refers to how fast information is sent from the selected PLA to this PLA. Phy Rx (Mb ps) refers to how fast information is received from the selected PLA to this PLA.

3.4 IP Se tting s
Use the IP screen to enable DHCP, or manually assign an IPv4 or IPv6 address, subnet mask, default gateway, and DNS server to the PLA.

PLA6457 User's Guide
20

Fig ure 10 IP Screen

Chapter 3 Web Configurator

The following table describes the labels in this screen.

Table 7 Configuration Screen

LA BEL

DESC RIPTIO N

IPv4 configuration

DHCP enabled

Select YES if your PLA is connected to a DHCP-enabled router that can assign it an IPv4 address. The IPv4 a ddre ss / ne tm a sk, De fa ult G a te wa y, and DNS fields will be filled automatically when configuration is received from the DHCPv4 server.

IPv4 address / netmask
Default Gateway
DNS

Select NO if you wish to assign an IPv4 Address, Subnet Mask, Default Gateway and DNS to your PLA. Enter the IPv4 address and subnet mask you wish to assign to your PLA.
This field is only available when you select No in the DHC P e na b le d field. Enter the gateway IP address you wish to assign to your PLA.
This field is only available when you select No in the DHC P e na b le d field. Enter the IPv4 DNS server address you configure manually.

This field is only available when you select No in the DHC P e na b le d field. Click O k for the changes to take effect.

Note: All changes except the DNS server will only take effect after a system reboot.

IPv6 configuration

DHCP enabled

Select YES if your PLA is connected to a DHCP-enabled router that can assign it an IPv6 address. The IPv6 a ddre ss / pre fix, De fa ult G a te wa y, and DNS fields will be filled automatically when configuration is received from the DHCPv6 server.

Select NO if you wish to assign an IPv4 Address, Subnet Mask, Default Gateway and DNS to your PLA.

PLA6457 User's Guide
21

Chapter 3 Web Configurator

Table 7 Configuration Screen (continued)

LA BEL
IPv6 address / prefix

DESC RIPTIO N
Enter the IPv6 address you wish to assign to your PLA and the address prefix length to specify how many most significant bits in an IPv6 address compose the network address.

Default Gateway

This field is only available when you select No in the DHC P e na b le d field.
Enter the IP address of the next-hop gateway. The gateway is a router connected to your PLA. The gateway helps forward packets to their destinations.

DNS

This field is only available when you select No in the DHC P e na b le d field. Enter the IPv6 DNS server address you configure manually.

This field is only available when you select No in the DHC P e na b le d field.

IPv6 link-local address

This field displays the IPv6 link-local address and the network prefix that the PLA generates itself for the interface.

IPv6 SLAAC address

This field displays the IPv6 SLAAC (Stateless Address Auto-configuration) IP address and prefix obtained from an IPv6 router in the network.

Click O k for the changes to take effect.

Note: All changes except the DNS server will only take effect after a system reboot.

3.5 Ethe rne t Se tting s
Use the Ethe rne t screen to view information on the PLA's Ethernet port. as well as set the PLA's power saving mode.
Fig ure 11 Ethernet Screen

The following table describes the labels in this screen.

Table 8 Ethernet Screen

LA BEL

DESC RIPTIO N

Ethernet

External Interfaces

Interface

This shows ETHA and ETHB (PLA's Ethernet port).

Speed

This shows a link rate of 100 Mbps for ETHA, and a link rate of 1000 Mbps for ETHB.

PLA6457 User's Guide
22

Chapter 3 Web Configurator

Table 8 Ethernet Screen (continued)

LA BEL Duplex
Interface Type

DESC RIPTIO N
This shows the duplex setting (Full or Half). Half duplex cannot send and receive at the same time. Full duplex can send and receive at the same time.
MII (Media Independent Interface) is the interface between the media access control (MAC) and the PLA.

RG MII (Reduced Gigabit Media Independent Interface) is displayed for the PLA that connects to a device requiring Internet over Powerline, such as a computer.

Mode Internal PHY Link
Powersaving Inactivity detection mode

SG MII (Serial Gigabit Media Independent Interface) is displayed for the PLA that connects to a device for Internet access, such as a router. This shows MAC. This is the Ethernet's internal physical layer and will always show No . This shows YES when the PLA has an active connection with a router or computer. Otherwise, it will show No .
Select ETH link to have the selected PLAs go into standby mode when there is no Ethernet connection.

Select ETH a c tivity to have the selected PLAs go into standby mode when there is no Ethernet activity detected.

Inactivity time(s)

Otherwise, select Disa ble d to have the PLAs never go into standby mode. The default setting is Disa b le d.
Set the period of time (5 to 86,400 seconds) when the PLA will go into standby mode when no Ethernet connection or activity is detected (based on your selection in the Ina c tivity de te c tio n m o de field).

This field is not available if you select Disa b le d in the Ina c tivity de te c tio n m o de field.

3.6 De vic e Se tting s
Use the De vic e screen to view basic system information of the PLA. You can also change the password for accessing the Web Configurator.
This screen also lets you upload new firmware to your PLA. You can download new firmware releases from your nearest Zyxel FTP site (or www.zyxel.com) to upgrade your device's performance. The upload process uses HTTP (Hypertext Transfer Protocol) and may take up to 2 minutes. After a successful upload, the PLA will reset.

PLA6457 User's Guide
23

Chapter 3 Web Configurator Fig ure 12 Device Screen

The following table describes the labels in this screen. After you see the firmware updating screen, wait 2 minutes before logging into the PLA again.

Table 9 Device Screen

LA BEL

DESC RIPTIO N

Hardware information

Device name

This field displays the PLA system name. It is used for identification.

Device description

This field shows that this is a G.hn bridge PLA.

Device manufacturer

This field displays the manufacturer of this PLA.

Serial number

This field displays the manufacturer assigned number of this PLA.

MAC address

This field displays the Ethernet adapter MAC (Media Access Control) address of this PLA.

HW version

This field displays the hardware version number of this PLA.

Software information

FW version

This field displays the current version of the firmware inside this PLA.

System uptime

This field displays how long the PLA has been running since it last started up. The PLA starts up when you plug it in, or when you reset it.

Security

New Configuration password

Type your new Web Configurator password. The password must consist of 6 to 64 characters, including 0 to 9 and a to z (case sensitive). Note that as you type a password, the screen displays a (*) for each character you type. Then click O k. After you change the password, use the new password to access the PLA.

HTTP SW update

PLA6457 User's Guide
24

Chapter 3 Web Configurator

Table 9 Device Screen (continued)

LA BEL

DESC RIPTIO N

Upgrade file

Type the location of the file you want to upload in this field or click Bro wse to find it.

Browse

Note: Only use firmware for your PLA. Do NOT remove power from the PLA while firmware upload is in progress!
Click this to find the .bin file you want to upload. Remember that you must decompress compressed (.zip) files before you can upload them.
Click O k to begin the upload process. This process may take up to 2 minutes. When the Do wnlo a d Pro g re ss bar reaches 100 % , click Ha rdwa re Re se t.

Note: The PLA will reset and the Web Configurator will refresh to the Lo g in screen upon successful installation. It is recommended that you compare the software version shown on the Web Configurator's De vic e page FW ve rsio n field with the firmware version installed, to confirm if the installation is successful.

3.7 Multic a st Se tting s
Multicast delivers IP packets to members defined by multicast groups. Membership to these multicast groups are established using IGMP/MLD.
Internet Group Multicast Protocol (IGMP) is an IPv4 network-layer protocol used to establish membership in a Multicast group ­ it is not used to carry user data.
Multicast Listener Discovery (MLD) is an IPv6 network-layer protocol that uses ICMPv6 message types, rather than IGMP message types. MLDv1 is equivalent to IGMPv2 and MLDv2 is equivalent to IGMPv3.
Use the Multic a st screen to configure IGMP/MLD settings.

PLA6457 User's Guide
25

Chapter 3 Web Configurator Fig ure 13 Multicast Screen

The following table describes the labels in this screen.

Table 10 Multicast Screen

LA BEL

DESC RIPTIO N

Multicast Configuration

IGMP Snooping Select YES to allow the PLA to learn multicast group. Otherwise, select NO to disable it.

MLD Snooping

Select YES to allow the PLA to discover the presence of MLD (Multicast Listener Discovery)
members who wish to receive multicast packets. Otherwise, select NO to disable it.

IGMP/MLD broadcast report

This field is only available when IG MP Sno o ping is YES.
Select NO to drop IGMP/MLD reports until a multicast member is discovered. Then the reports are sent to the member.

Select YES to have the PLA send IGMP/MLD reports according to the next field.

IGMP/MLD broadcast report mode

This field is only available when IG MP/ MLD b ro a dc a st re po rt is YES.
· Select 0 to allow the PLA to send IGMP/MLD reports even when the video source is
unknown.
· Select 1 to allow the PLA to always send IGMP/MLD reports. · Select 2 to allow the PLA to send IGMPv3 IGMP/MLD reports even when the video source is
unknown.

Filter unknown Select YES to allow the PLA to listen to multicast traffic on networks defined by multicast groups multicast traffic only. Otherwise, select NO to disable it.

IGMP Multicast ranges

Up to 4 multicast IP address ranges can be configured defining the minimum and maximum IP
addresses of each range. Only multicast traffic within these ranges will be processed by the
PLA.

This field is only available when IG MP Sno o ping is NO . Click O k for the changes to take effect.

PLA6457 User's Guide
26

Chapter 3 Web Configurator

Table 10 Multicast Screen (continued)

LA BEL

DESC RIPTIO N

Broadcast suppression

Broadcast xput limit (Mbps)

Broadcast suppression prevents the Ethernet port from being overloaded by a broadcast storm. In Bro a dc a st xput lim it, set the maximum throughput allowed before suppressing broadcast traffic. 0 disables broadcast suppression.

Click O k for the changes to take effect.

Upon clicking O k for Bro a dc a st suppre ssio n, reboot your PLA by clicking Ha rdwa re Re se t to make the changes when the next screen appears.

Fig ure 14 Hardware Reset

Note: Do NOT click O k for Fa c to ry Re se t.
3.8 Lo g File Se tting s
Use the Lo g file screen to allow your PLA to send event logs to an FTP server. You can set the data capture time interval as well as how often it uploads to the FTP server. Fig ure 15 Log File Screen

The following table describes the labels in this screen.

Table 11 Log file Screen

LA BEL

DESC RIPTIO N

Log File Configuration

Enable Log File

Select YES to allow your PLA to send event logs to an FTP server. Otherwise, select NO to disable it.

PLA6457 User's Guide
27

Chapter 3 Web Configurator

Table 11 Log file Screen (continued)

LA BEL

DESC RIPTIO N

Data capture interval(s)

This field allows you to set the time interval (1 ­ 9,999,999 seconds) to capture data.

FTP server URL

This field allows you to set the web address of the remote FTP server where the files (logs) will be uploaded.

FTP server login

This field allows you to set the name for logging in to the FTP server. The login name must contain 1 to 30 characters, including 0 to 9, a to z, and !@#%*()­_+=~,.{}[]\.

FTP server password

This field allows you to set the password for logging in to the FTP server. The login password must contain 1 to 30 characters, including 0 to 9, a to z, and !@#%*()­_+=~,.{}[]\.

Upload to server This field allows you to set the time interval (1 ­ 9,999,999 minutes) to send the captured data to

interval (min)

the remote server. Enter 0 to disable this function.

PLA6457 User's Guide
28

C HA PTER 4 G .hn Ne two rk Se tup Tuto ria l

4.1 O ve rvie w
Use this tutorial to expand your existing G.hn network.
After setting up your first home network (instructions for that are in the Quick Start Guide for your Zyxel PLA) you may want to extend the network or create a new one by adding additional PLAs. This tutorial shows you the following.
· How to start up your new PLA. You need to do this before you can begin the next sections. · How to make your existing G.hn network bigger by adding new PLAs. · How to make a new network separate from your existing network with new PLAs.
The tutorial uses the Web Configurator to set up your PLA.
Note: The PLA in this tutorial is an example only. Your PLA may be different.

4.2 Im po rta nt Te rm s

Domain Name

The domain name allows a PLA to connect with other PLAs that have the same domain name. It provides security for your G.hn network. The domain name uses English letters or numbers, from 8 to 64 characters long, with no spaces allowed. (See Section 3.3 on page 19 for more information.)

4.3 Ac c e ssing Yo ur PLA
1 Plug the PLA you want to add to your network into a power socket and, if needed, switch the power socket on. Fig ure 16 Plug Your PLA into a Power Socket
PLA
1
2 Connect the PLA to your computer. PLA6457 User's Guide
29

Chapter 4 G.hn Network Setup Tutorial 3 Use a LAN or Ethernet cable (shown below) to connect the LAN or Ethernet port on your adapter to the
same kind of port on your computer. Fig ure 17 Connect Your PLA to a Computer
3 2
4 Open the Web Configurator on your computer. See Section 3.2 on page 18 for how to launch the Web Configurator.
5 You are now ready to extend your G.hn network or set up a second network. · See Section 4.4 on page 30 to add a new PLA to your network. · See Section 4.5 on page 32 to set up a second network with your new adapters.
4.4 Adding a PLA
This section shows you how to add a new PLA to expand your existing network. The figure below shows the family computer with Internet access on a G.hn network. Expand the network by adding a new PLA connected to a printer. Fig ure 18 Add a Printer to Your G.hn Network
PLA6457 User's Guide
30

Chapter 4 G.hn Network Setup Tutorial Note: You do not need to know the domain name of the new adapter to add it to your
network. 1 Connect your computer to the PLA you want to add to your network and open the Web Configurator
(see Section 4.3 on page 29). 2 Go to the G .hn screen. On this screen in the De vic e ID field your new PLA should appear as 1 (A). Check
the De vic e ID 1 adapter's MAC address (B). It should match the MAC address listed on the label on the back of your PLA. Fig ure 19 Adding a New Adapter
B A
C D
3 Type the password for your existing network in the Pa iring pa sswo rd field (C ). Then click PAIR (D). 4 Your new adapter will now have the same Do ma in Na me as your existing network and so has now
joined your existing network. 5 Connect the adapter's Ethernet port to the device's LAN port to add the device to the network, for
example, your Internet refrigerator in the kitchen. 6 Plug the adapter into a power outlet. 7 Repeat this procedure for all additional PLAs that you want to add to your existing or new G.hn network.
PLA6457 User's Guide
31

Chapter 4 G.hn Network Setup Tutorial
4.5 Se tting Up a Ne w Ne two rk with a Ne w PLA
This section shows you how to use your new PLAs to set up a new G.hn network separate to your existing network. The figure below shows two G.hn networks in a house. The first network (1) shows the home computer connected to a printer and access to the Internet. The second network (2) has no Internet access but with a media adapter such as the Zyxel DMA-1100P you can use your TV to watch movies and play games which are stored on a computer. Fig ure 20 Add New Adapters to Make a Second Network
1 Connect your new PLA and open the Web Configurator as shown in Section 4.5 on page 32. The screen shown below appears.
2 Type a Do m a in Na m e that is different from the Do m a in Na m e for your existing network. Make sure you use the same new Do m a in Na m e for all new adapters you want to add to your new network.
PLA6457 User's Guide
32

Chapter 4 G.hn Network Setup Tutorial Fig ure 21 Making a New Network with the New Adapter
3 After you have set up a new network, you are ready to connect each PLA on your new network to devices, for example, a computer or a games console.
PLA6457 User's Guide
33

C HA PTER 5 Tro ub le sho o ting
This chapter offers some suggestions to solve problems you might encounter.
5.1 Po we r a nd Lig ht Pro b le m s
The PLA does not turn on. None of the lights turn on.
1 Disconnect and re-connect the PLA. 2 Remove the PLA from the outlet. Then connect an electrical device that you know works into the same
power outlet. This checks the status of the power outlet. 3 If the problem continues, contact the vendor.
The ETHERNET light does not turn on.
1 Check the hardware connections. See the Quick Start Guide. 2 Inspect your cables for damage. Contact the vendor to replace any damaged cables. 3 Check the Ethernet adapter on your computer and make sure it is enabled and working properly. 4 If the PLA is connected to an Ethernet switch or router, make sure the device is working correctly, and
that the LAN network is working and configured correctly as well.
The Powerline light does not turn on.
1 Make sure the adapter is plugged in to a power socket and the power socket is turned on. 2 Use the Web Configurator to detect all other PLAs on your G.hn Network. Make sure that the domain
name (sometimes called the network password) is the same on all of your PLAs. See Section 3.4 on page 20 for instructions on changing the network name. 3 Check the MAC address for all PLAs are shown correctly in the Web Configurator. See Section 3.6 on page 23 for instructions on checking the MAC address.
PLA6457 User's Guide
34

Chapter 5 Troubleshooting
4 Make sure that all your PLAs are G.hn compliant. Check the package it came in or ask your vendor. This PLA cannot detect earlier versions of G.hn PLAs such as G.hn 1.0 or 1.0.1. (Although they can coexist on the same electrical wiring without interfering with each other.)
5 Make sure that the PLAs on your network are all on the same electrical wiring. Connect another PLA into an outlet close to your PLA's power outlet. They are probably now on the same electrical wiring. Check the Powerline ( ) light. If it now lights up your PLA was probably previously on separate electrical wiring. Ask an electrician for more information on the electrical wiring in your building.
6 Make sure that you do not have a power meter between PLAs. Powerline signals cannot pass this.
The Power and Powerline light blink at the same time indicating an error in pairing.
You have pressed the ENC RYPTbutton for more than 5 seconds. Try setting up a connection again, this time pressing the ENC RYPTbuttons on both devices for less than 5 seconds.
5.2 We b C o nfig ura to r Pro b le m s
The Web Configurator does not display all or any of my devices.
Inspect the LEDs on your PLA and make sure that the ETHERNET and Powerline LEDs are on or blinking. See Section 1.2 on page 8 for troubleshooting LED related problems.
I don't know the IP address of the PLA.
There is no default fixed management IP address for the PLA. You need to log into your router to see the IP address the router gave to the PLA. Follow this procedure if you cannot log into the router to see the assigned IP address. 1 Connect your PLA to your router's LAN port using an Ethernet cable. 2 Connect the router's LAN port to your computer's LAN port using another Ethernet cable. 3 Download an IP scanner software, such as Advanced IP Scanner, and use it to scan the IP address used. The IP address list should include the IP addresses of the router, the PLA, and the computer connected to the router. If you want to assign a static IP address to your PLA, please follow the instructions below. 1 Type the IP address of the PLA using an Internet browser to log into the PLA's Web Configurator. After logging into the Web Configurator, go to the IP screen.
PLA6457 User's Guide
35

Chapter 5 Troubleshooting
2 Under IPv4 C o nfig ura tio n, disable DHC P e na b le and then assign an IP in the IPv4 a ddre ss field as the static IP. You can now use this IP address as the default IP address to log into the PLA's Web Configurator. Note: The static IP must be in the same subnet of the router.
5.3 Po we rline Pro b le m s
The signal on my G.hn Network is weak.
1 Your PLAs cannot be connected to extension cords. Connect them to standard power outlets. 2 Your PLAs may be located close to large appliances such as refrigerators or air-conditioners that cause
interference with the Powerline signal. Move the adapters further away from such appliances to reduce interference. 3 Your PLAs may be placed close to electrical devices such as electrical insect-killers which produce radio waves. These may interfere with the Powerline signals. Move the adapters further away from such electrical devices. 4 Your wiring may be old and/or low quality or with a long wiring path.
5.4 ENC RYPTButto n Pro b le m s
The Power light does not blink when I press the ENC RYPTbutton.
· Check that the device is on. · Press the ENC RYPTbutton again, making certain you have pressed the button for 2 to 5 seconds. · For PLA, you cannot use the ENC RYPTbutton when it is in standby mode. Connect the PLA to a
computer or router, then try again.
The Power lights on both devices blink when I press the ENCRYPT buttons, but the Powerline light does not turn on.
· Ensure you have pressed the ENC RYPTbuttons on both devices. · Wait for about a minute while the devices set up a connection. · If that does not work, try again with both devices connected to a power strip next to each other. If
they now connect, then the devices were not on the same electrical circuit before.
PLA6457 User's Guide
36

Chapter 5 Troubleshooting The Power lights on both devices blink, then the Powerline light blinks red.
Do not worry, the connection process is proceeding normally. The Power lights on both devices finished blinking, but only one device's Powerline light is on.
One device may have connected to a third PLA. To check if device A is connected to device B and not to device C, disconnect device B from its power source. Device A's Powerline ( ) light will turn off if the connection is with device B and stay on if it is with device C. Disconnect device A from device C by pressing the RESETbutton on device C for 10 ­ 15 seconds. And then reconnect device A to device B by pressing the ENC RYPTbutton for 2 to 5 seconds on both devices within 120 seconds.
PLA6457 User's Guide
37

A PPEN DIX A
C usto m e r Suppo rt

In the event of problems that cannot be solved by using this manual, you should contact your vendor. If you cannot contact your vendor, then contact a Zyxel office for the region in which you bought the device.
See http s://www.zyxe l.c o m/ho me p a g e .shtml and also http s://www.zyxe l.c o m/a b o ut_zyxe l/zyxe l_wo rldwide .shtml for the latest information.
Please have the following information ready when you contact an office.
Re q uire d Info rm a tio n
· Product model and serial number. · Warranty Information. · Date that you received your device. · Brief description of the problem and the steps you took to solve it.

C o rpo ra te He a dq ua rte rs (Wo rldwide )
Ta iwa n
· Zyxel Communications Corporation · https://www.zyxel.com

A sia

C hina
· Zyxel Communications (Shanghai) Corp. Zyxel Communications (Beijing) Corp. Zyxel Communications (Tianjin) Corp.
· https://www.zyxel.com/cn/zh/
Ind ia
· Zyxel Technology India Pvt Ltd. · https://www.zyxel.com/in/en/
Ka za khsta n
· Zyxel Kazakhstan · https://www.zyxel.kz

PLA6457 User's Guide
38

Appendix A Customer Support
Ko re a
· Zyxel Korea Corp. · http://www.zyxel.kr
Ma la ysia
· Zyxel Malaysia Sdn Bhd. · http://www.zyxel.com.my
Pa kista n
· Zyxel Pakistan (Pvt.) Ltd. · http://www.zyxel.com.pk
Philippine s
· Zyxel Philippines · http://www.zyxel.com.ph
Sing a po re
· Zyxel Singapore Pte Ltd. · http://www.zyxel.com.sg
Ta iwa n
· Zyxel Communications Corporation · https://www.zyxel.com/tw/zh/
Tha ila nd
· Zyxel Thailand Co., Ltd. · https://www.zyxel.com/th/th/
Vie tna m
· Zyxel Communications Corporation ­ Vietnam Office · https://www.zyxel.com/vn/vi
Euro pe
Be la rus
· Zyxel BY · https://www.zyxel.by
Be lg ium
· Zyxel Communications B.V. · https://www.zyxel.com/be/nl/
PLA6457 User's Guide
39

Appendix A Customer Support
· https://www.zyxel.com/be/fr/
Bulg a ria
· Zyxel  · https://www.zyxel.com/bg/bg/
C ze c h Re pub lic
· Zyxel Communications Czech s.r.o · https://www.zyxel.com/cz/cs/
De nm a rk
· Zyxel Communications A/S · https://www.zyxel.com/dk/da/
Esto nia
· Zyxel Estonia · https://www.zyxel.com/ee/et/
Finla nd
· Zyxel Communications · https://www.zyxel.com/fi/fi/
Fra nc e
· Zyxel France · https://www.zyxel.fr
G e rm a ny
· Zyxel Deutschland GmbH · https://www.zyxel.com/de/de/
Hung a ry
· Zyxel Hungary & SEE · https://www.zyxel.com/hu/hu/
Ita ly
· Zyxel Communications Italy · https://www.zyxel.com/it/it/
La tvia
· Zyxel Latvia · https://www.zyxel.com/lv/lv/
PLA6457 User's Guide
40

Appendix A Customer Support
Lithua nia
· Zyxel Lithuania · https://www.zyxel.com/lt/lt/
Ne the rla nds
· Zyxel Benelux · https://www.zyxel.com/nl/nl/
No rwa y
· Zyxel Communications · https://www.zyxel.com/no/no/
Po la nd
· Zyxel Communications Poland · https://www.zyxel.com/pl/pl/
Ro m a nia
· Zyxel Romania · https://www.zyxel.com/ro/ro
Russia
· Zyxel Russia · https://www.zyxel.com/ru/ru/
Slo va kia
· Zyxel Communications Czech s.r.o. organizacna zlozka · https://www.zyxel.com/sk/sk/
Spa in
· Zyxel Communications ES Ltd. · https://www.zyxel.com/es/es/
Swe de n
· Zyxel Communications · https://www.zyxel.com/se/sv/
Switze rla nd
· Studerus AG · https://www.zyxel.ch/de · https://www.zyxel.ch/fr
PLA6457 User's Guide
41

Appendix A Customer Support
Turke y
· Zyxel Turkey A.S. · https://www.zyxel.com/tr/tr/
UK
· Zyxel Communications UK Ltd. · https://www.zyxel.com/uk/en/
Ukra ine
· Zyxel Ukraine · http://www.ua.zyxel.com
So uth Am e ric a
Arg e ntina
· Zyxel Communications Corporation · https://www.zyxel.com/co/es/
Bra zil
· Zyxel Communications Brasil Ltda. · https://www.zyxel.com/br/pt/
C o lo m b ia
· Zyxel Communications Corporation · https://www.zyxel.com/co/es/
Ec ua do r
· Zyxel Communications Corporation · https://www.zyxel.com/co/es/
So uth Am e ric a
· Zyxel Communications Corporation · https://www.zyxel.com/co/es/
Middle Ea st
Isra e l
· Zyxel Communications Corporation · http://il.zyxel.com/
PLA6457 User's Guide
42

Appendix A Customer Support
Middle Ea st
· Zyxel Communications Corporation · https://www.zyxel.com/me/en/
No rth Am e ric a USA
· Zyxel Communications, Inc. ­ North America Headquarters · https://www.zyxel.com/us/en/
O c e a nia Austra lia
· Zyxel Communications Corporation · https://www.zyxel.com/au/en/
Afric a So uth Afric a
· Nology (Pty) Ltd. · https://www.zyxel.com/za/en/
PLA6457 User's Guide
43

A PPEN DIX B
Le g a l Info rm a tio n
C o pyrig ht
Copyright © 2021 by Zyxel and/or its affiliates. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of Zyxel and/or its affiliates. Published by Zyxel and/or its affiliates. All rights reserved.
Disc la im e r
Zyxel does not assume any liability arising out of the application or use of any products, or software described herein. Neither does it convey any license under its patent rights nor the patent rights of others. Zyxel further reserves the right to make changes in any products described herein without notice. This publication is subject to change without notice.
Re g ula to ry No tic e a nd Sta te m e nt
EURO PEA N UNIO N

The following information applies if you use the product within the European Union.
List o f na tio na l c o de s

COUNTRY Austria Belgium Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Iceland Ireland Italy Latvia

ISO 3166 2 LETTER CODE AT BE BG HR CY CZ DK EE FI FR DE GR HU IS IE IT LV

COUNTRY Liechtenstein Lithuania Luxembourg Malta Netherlands Norway Poland Portugal Romania Serbia Slovakia Slovenia Spain Switzerland Sweden Turkey United Kingdom

ISO 3166 2 LETTER CODE LI LT LU MT NL NO PL PT RO RS SK SI ES CH SE TR GB

Sa fe ty Wa rning s
· Do not use this product near water, for example, in a wet basement or near a swimming pool. · Do not expose your device to dampness, dust or corrosive liquids. · Do not store things on the device.

PLA6457 User's Guide
44

Appendix B Legal Information
· Do not obstruct the device ventilation slots, as insufficient airflow may harm your device. For example, do not place the device in an enclosed space such as a box or on a very soft surface such as a bed or sofa.
· Do not install, use, or service this device during a thunderstorm. There is a remote risk of electric shock from lightning. · Connect ONLY suitable accessories to the device. · Do not open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other risks. ONLY qualified
service personnel should service or disassemble this device. Please contact your vendor for further information. · Make sure to connect the cables to the correct ports. · Place connecting cables carefully so that no one will step on them or stumble over them. · Always disconnect all cables from this device before servicing or disassembling. · Do not remove the plug and connect it to a power outlet by itself; always attach the plug to the power adaptor first before connecting it to
a power outlet. · Do not allow anything to rest on the power adaptor or cord and do NOT place the product where anyone can walk on the power adaptor
or cord. · Please use the provided or designated connection cables/power cables/ adaptors. Connect it to the right supply voltage (for example, 110
V AC in North America or 230 V AC in Europe). If the power adaptor or cord is damaged, it might cause electrocution. Remove it from the device and the power source, repairing the power adapter or cord is prohibited. Contact your local vendor to order a new one. · Do not use the device outside, and make sure all the connections are indoors. There is a remote risk of electric shock from lightning. · CAUTION: Risk of explosion if battery is replaced by an incorrect type, dispose of used batteries according to the instruction. Dispose them at the applicable collection point for the recycling of electrical and electronic devices. For detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the store where you purchased the product. · The following warning statements apply, where the disconnect device is not incorporated in the device or where the plug on the power supply cord is intended to serve as the disconnect device, ­ For permanently connected devices, a readily accessible disconnect device shall be incorporated external to the device; ­ For pluggable devices, the socket-outlet shall be installed near the device and shall be easily accessible.
Enviro nm e nt Sta te m e nt
Dispo sa l a nd Re c yc ling Info rm a tio n
The symbol below means that according to local regulations your product and/or its battery shall be disposed of separately from domestic waste. If this product is end of life, take it to a recycling station designated by local authorities. At the time of disposal, the separate collection of your product and/or its battery will help save natural resources and ensure that the environment is sustainable development.
Die folgende Symbol bedeutet, dass Ihr Produkt und/oder seine Batterie gemäß den örtlichen Bestimmungen getrennt vom Hausmüll entsorgt werden muss. Wenden Sie sich an eine Recyclingstation, wenn dieses Produkt das Ende seiner Lebensdauer erreicht hat. Zum Zeitpunkt der Entsorgung wird die getrennte Sammlung von Produkt und/oder seiner Batterie dazu beitragen, natürliche Ressourcen zu sparen und die Umwelt und die menschliche Gesundheit zu schützen.
El símbolo de abajo indica que según las regulaciones locales, su producto y/o su batería deberán depositarse como basura separada de la doméstica. Cuando este producto alcance el final de su vida útil, llévelo a un punto limpio. Cuando llegue el momento de desechar el producto, la recogida por separado éste y/o su batería ayudará a salvar los recursos naturales y a proteger la salud humana y medioambiental.
Le symbole ci-dessous signifie que selon les réglementations locales votre produit et/ou sa batterie doivent être éliminés séparément des ordures ménagères. Lorsque ce produit atteint sa fin de vie, amenez-le à un centre de recyclage. Au moment de la mise au rebut, la collecte séparée de votre produit et/ou de sa batterie aidera à économiser les ressources naturelles et protéger l'environnement et la santé humaine.
Il simbolo sotto significa che secondo i regolamenti locali il vostro prodotto e/o batteria deve essere smaltito separatamente dai rifiuti domestici. Quando questo prodotto raggiunge la fine della vita di servizio portarlo a una stazione di riciclaggio. Al momento dello smaltimento, la raccolta separata del vostro prodotto e/o della sua batteria aiuta a risparmiare risorse naturali e a proteggere l'ambiente e la salute umana.
Symbolen innebär att enligt lokal lagstiftning ska produkten och/eller dess batteri kastas separat från hushållsavfallet. När den här produkten når slutet av sin livslängd ska du ta den till en återvinningsstation. Vid tiden för kasseringen bidrar du till en bättre miljö och mänsklig hälsa genom att göra dig av med den på ett återvinningsställe.
Ab o ut the Sym b o ls
Various symbols are used in this product to ensure correct usage, to prevent danger to the user and others, and to prevent property damage. The meaning of these symbols are described below. It is important that you read these descriptions thoroughly and fully understand the contents.
PLA6457 User's Guide
45

Appendix B Legal Information

Expla na tio n o f the Sym b o ls

SYMBOL

EXPLANATION Alternating current (AC): AC is an electric current in which the flow of electric charge periodically reverses direction.

Direct current (DC): DC if the unidirectional flow or movement of electric charge carriers.
Earth; ground: A wiring terminal intended for connection of a Protective Earthing Conductor.

Class II equipment:
The method of protection against electric shock in the case of class II equipment is either double insulation or reinforced insulation.

Vie wing C e rtific a tio ns
Go to http://www.zyxel.com to view this product's documentation and certifications.
Zyxe l Lim ite d Wa rra nty
Zyxel warrants to the original end user (purchaser) that this product is free from any defects in material or workmanship for a specific period (the Warranty Period) from the date of purchase. The Warranty Period varies by region. Check with your vendor and/or the authorized Zyxel local distributor for details about the Warranty Period of this product. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, Zyxel will, at its discretion, repair or replace the defective products or components without charge for either parts or labor, and to whatever extent it shall deem necessary to restore the product or components to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal or higher value, and will be solely at the discretion of Zyxel. This warranty shall not apply if the product has been modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions.
No te
Repair or replacement, as provided under this warranty, is the exclusive remedy of the purchaser. This warranty is in lieu of all other warranties, express or implied, including any implied warranty of merchantability or fitness for a particular use or purpose. Zyxel shall in no event be held liable for indirect or consequential damages of any kind to the purchaser. To obtain the services of this warranty, contact your vendor. You may also refer to the warranty policy for the region in which you bought the device at http://www.zyxel.com/web/support_warranty_info.php.
Re g istra tio n
Register your product online at www.zyxel.com to receive email notices of firmware upgrades and related information.
O pe n So urc e Lic e nse s
This product may contain in part some free software distributed under GPL license terms and/or GPL-like licenses. To request the source code covered under these licenses, please go to: https://www.zyxel.com/form/gpl_oss_software_notice.shtml

PLA6457 User's Guide
46

Index
Inde x

A
AC pass-through 7 accessing the PLA 29 add
new adapter 31 PLA 30 Advanced Encryption Standard, see AES 8 AES 17 AES (Advanced Encryption Standard) 8

disclaimer 44
DNS 21
Domain Name 31 security 11
domain name 10, 31 criteria 29 default 20 HomeGrid 10 unknown 12, 15
duplex setting 23

B
broadcast suppression 27
maximum amount allowed 27
C
certifications 44 viewing 46
configuration screen 23, 25 connect to computer 29 connections overview 10 contact information 38 copyright 44 customer support 38
D
data capture interval 28 device ID 19 device name 24 Device screen 23 DHCP client 18 DHCP-enabled router 21

E
electrical circuit boundaries 17 ENCRYPT button 7, 9, 10, 14
manage 9 overview 12 problem 36 working requirement 12 ENCRYPT connection procedure 13 ENCRYPT feature 10, 12 encrypted pairing setting up 10 encrypted pairing LED behavior 12 encryption 8, 17 Encryption configuration 20 Ethernet activity no detection 23 Ethernet connection
inactivity 23 Ethernet port
number of 7 Ethernet screen 22 expand the network 9
PLA6457 User's Guide
47

F
firmware upgrade 25 firmware version 24 FTP server 28 FTP server password 28 Full duplex 23
G
G.hn 7 G.hn network 7
join 12 setup 12 G.hn profile 20 G.hn screen 19 G.hn standard 10 gateway IP address PLA 21
H
Half duplex 23 hardware information
PLA 24 hardware reset 27

Index
introduction 7 IP packets 25 IP screen 20 IPv4 address 21 IPv6 address 22 IPv6 configuration 21
J
Java permission 17 JavaScript 17
L
LED 34 ENCRYPTED PAIRING 9 ETHERNET 9 POWER 8 POWERLINE 8
LEDs 8 legal information 44 limited warranty 46 local vs. remote adapter 22, 26, 27 Log File screen 27 login
Web Configurator 18

I

M

IGMP 25 IGMP Multicast range 26 IGMP snooping 26 IGMP/MLD 25 IGMP/MLD broadcast report 26
mode 26 IGMPv2 25 IGMPv3 25 inactivity detection mode 23 inactivity time
detection 23 Internet Group Multicast Protocol (IGMP) 25

MAC address 22, 24, 26, 27 Ethernet adapter 24 PLA 19
manage the PLA 9 management
multiple networks 11 overview 17 managing the device
MIMO (multiple input multiple output) channel 20 MLD 25 MLD snooping 26 MLDv2 25

PLA6457 User's Guide
48

Index

Multicast configuration 26 multicast group 25 Multicast Listener Discovery (MLD) 25 Multicast screen 25 Multicast settings 25 multiple Powerline networks 11
N
network add more PLAs 14
network example 17 network information 19 network name
change 10 HomeGrid 18 network security prevent compromising 11 network setup example 17 new network setup 32
P
pass-through 7 password 24
for pairing 31 FTP server 28 Web Configurator 24 passwords 22, 26, 27 PHY internal 23 PHY rate maximum 7 PLA add to network 13 plug-and-play 17 power and light problem 34 power LED behavior 15 power pass-through 7 power saving 23 power saving mode 9

setup 22 Powerline
problem 36 Powerline circuit 11 Powerline LED behavior 12, 15 Powerline network
add devices 12 create multiple networks 14 priority settings 25, 27 private network 10 problem ENCRYPT button 36 power and light 34 Powerline 36 Web Configurator 35 problems and solutions 34
R
receive rate 19 Regulatory Notice and Statement 44 reset
PLA 25 RESET button 7, 9, 10
overview 15 reset PLA 27
S
safety warnings 44 security 10, 11, 18
passwords 10 serial number
PLA 24 software information 24 standby mode 9 subnet mask
PLA 21
T
time interval
PLA6457 User's Guide
49

data capture 28 upload to server 28 transfer rates 8 transmit rate 19 troubleshooting 34 tutorial expand existing Powerline network 29
U
upload to server interval 28 uptime
PLA 24
W
warranty 46 note 46
web browser pop-up window 17 Web Configurator 17, 24
password 24 problem 35 recommended screen resolution 17 supported web browsers 17

Index

PLA6457 User's Guide
50


Acrobat Distiller 11.0 (Windows)