Instruction Manual for universal douglas models including: 14049300, 14049300 LED Strip Fixture Retrofit Kit, LED Strip Fixture Retrofit Kit, Fixture Retrofit Kit, Retrofit Kit

LED LRA with Controls Installation Instructions

Benjamin Tamayo

LED LRA with Controls Installation Instructions

Resource Library - Universal Douglas

4 Foot & 8 Foot LED Retrofit Strip Assembly with Controls - Universal Douglas

Standardized Systems – LitePak™ 2 - Universal Douglas


File Info : application/pdf, 6 Pages, 996.75KB

PDF preview unavailable. Download the PDF instead.

LED-LRA-with-Controls-Installation-Instructions
SAFETY WARNINGS IMPORTANT SAFETY INFORMATION
Disconnect power before installation.
DANGER- RISQUE DE CHOC- COUPER L'ALIMENTATION AVANT L'INSTALLATION
LED Retrofit Assembly installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local electrical code. If you are not familiar with these codes and requirements, contact a qualified electrician.
ATTENTION- Risque d'incendie ou de choc électrique. L'installation du kit upgrade LED exige Ia connaissance des systèmes électriques pour luminaires. Si non qualifié, ne tentez pas d'installation. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n'êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié.
To prevent wiring damage or abrasion, do not expose wires to the edge of sheet metal or any other sharp objects.
ATTENTION- Pour éviter les dégâts de câblage par l'abrasion, ne pas mettre en contact les fils électriques avec des bords de tôle ou d'autres objets pointus.
Check the existing wiring for damage before Installing upgrade assembly. Do not install if existing wires are damaged.
ATTENTION- Risque d'incendie ou de choc électrique. Vérifier si le câblage existant n'est pas endommagé avant l'installation du kit upgrade LED. Ne pas installer si des fils sont endommagés.
Luminaire wiring and electrical parts may be damaged when drilling for installation of the LED upgrade assembly. Check for enclosed wiring and components.
ATTENTION- Risque d'incendie ou de choc électrique. Câblage électriques peuvent être endommagés Iors du perçage pour l'installation du kit upgrade LED. Vérifier les fils et composants.
UNPACKING THE KIT
For installation in 4ft or 8ft strip-style luminaires, suitable for dry or damp locations, with min. 4 inch width and 1- /11 16 inch depth.

· (1) Preassembled Universal Douglas LED 4' Primary Assembly Panel with: · (1) Universal Douglas LED Lensed Module · (1) Universal Douglas Driver · Associated connectors and wires
· (1) Preassembled Universal Douglas LED 4' Secondary Assembly Panel with: · (1) Universal Douglas LED Lensed Module · (2) End Mounting Brackets · (1) Universal Douglas Mounting Bracket
NOTE: Consult your local authority regarding disposal or recycling procedures of removed ballast and lamps.

www.universaldouglas.com Rev. 3/14/22

Page 1

14049300 Rev B
Install this assembly only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings.
ATTENTION- Risque d'incendie ou de choc électrique. lnstallez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions dans les photographies ou les dessins de Ia page suivante. IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OUVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE COMPOSANTS ÉLECTRIQUES AU COURS DE L'INSTALLATION DU NÉCESSAIRE.
Universal Lighting Technologies

INSTALLATION

USING EXISTING SOCKET BAR PLATES

: Verify the fluorescent fixture is a 4ft or 8ft strip fixture

of appropriate dimensions as shown in

. For

fixtures that are connected together in series on the

same branch circuit, identify the section to be retrofitted.

: Disconnect power to the fixture.

: Remove existing linear fluorescent lamps as shown in . Dispose of lamps per local regulations.

: Locate the ¼-turn fasteners as shown in

and

remove the cover panels on both strip light sections and

discard.

: Remove the socket mounting plate by gently prying

outward on the housing using a large flathead

screwdriver.

and .

For some strip light models the lampholder sockets can be removed without removing the socket mounting plate. See steps - .

www.universaldouglas.com Rev. 3/14/22

Page 2

14049300 Rev B

: Remove the sockets from the mounting plate as shown

in

.

: Replace mounting plate making sure that the holes are in the

same orientation as when removed. Insert the tab on the

mounting plate into the slot in the housing as shown in

.

Gently pry the housing outward with a large flat head screw

driver as shown in

and insert the tab of the mounting

plate into the slot in the housing.

Note the correct orientation of the holes in the mounting plates

in

.

: Repeat steps 5, 6, and 7 for the remaining 3 socket mount plates.

: Place your finger behind the lampholder socket as shown in Figure 8a and push the lampholder socket towards the center of the light fixture until the lampholder pops out of the socket mounting plate.
: Push the lampholder socket up and over the lampholder socket mounting plate. See Figures 8b and 8c.
Universal Lighting Technologies

INSTALLATION

: Repeat steps and for all lampholders.

www.universaldouglas.com Rev. 3/14/22

: Cut the branch circuit wires at the connection to the

fluorescent ballast leads in both strip light housings (if

ballasts exist in both housings) as shown in

.

: Remove the ballast(s) by removing the mounting screw and dispose of properly per local regulations. See
.

: Remove the Linear Retrofit Assembly from the packaging. There are one of two panel assemblies: one with a driver and module and one (LRA28 only) with a module only.

For 4' retrofits, skip to

.

For 8' retrofits locate the panel with the module only.

Mount and position this assembly to the fixture section

furthest from the branch circuit splice connections with

the blue and red leads facing the center of the fixture -

See

.

For LRA14 kits go straight to

.

: Insert the ends of the lanyards at each end of the panel assembly into the indicated holes as shown in
and .

Allow the assembly to hang by the lanyards as shown in .

For LRA14 kits skip to

.

Page 3

14049300 Rev B

: Route blue and red leads through the center of the

fuxture as shown in

.

: Lift the panel such that the lanyards at each end feed

through the holes in which they were inserted, as shown

in

.

: To use the 1/4 - turn fasteners, first remove the knockout.

Secure the panel assembly in place onto the strip light

housing, and fasten to the lampholder mounting plates

with the ¼-turn fasteners located at each end of the

assembly as shown in

and .

For alternate mounting using the drill-point screws provided, see Step 21A.

Universal Lighting Technologies

INSTALLATION
www.universaldouglas.com Rev. 3/14/22

: Locate the remaining panel assembly with the driver. Position the panel assembly for ease of connection to the branch circuit wiring in the fixture as shown in .
: Insert the ends of the lanyards at each end of the panel assembly into the indicated holes as shown in as done with the previous panel assembly. Allow the assembly to hang by the lanyards.

: Locate the red and blue lead wires with the orange 3position push-in connectors attached and locate the red and blue lead wires from the other tandem LRA panel assembly previously installed.

Push the blue wire into the connector with the other blue

wires and the red wire into the connector with the other

red wires as shown in

and .

Blue Tooth Wireless Dimming Interface (BTLWE)

· A Blue tooth wireless dimming interface is connected to the end of one of the light bars.
· This is powered by the driver and connects to the driver's 0-10V dimming leads
· Blue Tooth commands are received from a wireless dimming control.

LED MODULE

SERRATED HEAD SCREW GRO U N D S DRIVER TO HOUSING

WHITE

RED

BLACK

LED DRIVER BLUE

VIOLET GREY AUX 1 AUX 2

BT-LWE

LED MODULE

Page 4

14049300 Rev B

: Locate the Luminaire Disconnect with the ground wire

connected. Secure the ground wire to the equipment

grounding conductor in the luminaire or to the luminaire

housing in accordance with the National Electrical Code

(NFPA 70). See

. A ground screw is provided

with the kit if needed.

: From the branch circuit wires strip about 0.40 inches of

insulation. Insert the white branch circuit wire into the

white hole of the Luminaire Disconnect and the black

wire into the black hole. See

.

: Lift the panel such that the lanyards at each end feed

through the holes in which they were inserted as

performed with the previous panel assembly as shown

in

.

Secure the panel in place using the ¼-turn fasteners at each end of the panel.

Universal Lighting Technologies

INSTALLATION

USING ADJUSTABLE MOUNTING BRACKETS

: Verify the fluorescent fixture is 8 ft strip fixture of

appropriate dimensions as shown in

.

: Disconnect power to the fixture.

: Remove fluorescent components including:

a. Lamps b. Ballast cover

Lamp holders & brackets Ballast

Examine all parts that are not intended to be replaced by the retrofit assembly for damage and replace any damaged parts prior to installation of retrofit assembly.

: Attach center bracket Locate large bracket at center of 8 foot fixture .

Note: Be sure all existing wiring is above bracket.

Center bracket and use fixture as guide to bend to

correct width

.

Once bracket us bent to size secure with #8 drill point screw (supplied separately) on either side of
fixture.

www.universaldouglas.com Rev. 3/14/22

Page 5

14049300 Rev B

: Attach end brackets.

Locate bracket align with end of fixture Ensure tether hook features point inboard .

Center bracket width and use fixture as guide to

bend to correct width

.

Once bracket us bent to size secure with #8 drill

point screw (supplied separately) on either side of

fixture

.

Repeat at outer end of fixture.

: Suspended panels from tethers by inserting "T" end of captive tether into hook features in brackets
at both ends of panel .

: Repeat steps 4-6 for secondary panel.

: While panels are suspended make the following connections:

Connect primary module ground lead to existing

fixture ground screw

.

Ground lead position may be moved to alternate

location

.

Universal Lighting Technologies

INSTALLATION

USING ADJUSTABLE MOUNTING BRACKETS

: Before making connection route all wire over

brackets to ensure panel seats properly (

).

Connect red and blue leads from secondary panel to orange push in connectors from driver) and .

: Connect incoming power with luminaire disconnect plug on driver input (black and white) ( ).

DRIVER PROGRAMMING

14049300 Rev B

Driver output currents can be programmed at different levels to change the system's light output and input power. The driver currents must be programmed within the ranges shown
in the table below:

LRAyC14-HL8xx-U-70LC LRAyC14-ML8xx-U-42LC LRAyC28-HL8xx-U-12KC LRAyC28-HL8xx-U-85LC LRAyC28-ML8xx-U-65LC
x= 35, 40, 50 y= 4 or 5

D15CC55UNVPW-C D10CC30UNVPW-C D21CC80UNVPW-C D21CC80UNVPW-C D15CC55UNVPW-C

900mA 1050mA 1500mA 750mA 1500mA

Contact your local ULT sales representative for driver programming tools and support.

: Lift panel into place and secure with captive ¼ turn panel fasteners.
Repeat for second panel

BT-LWE EMERGENCY OPERATION
The BT-LWE can be configured to act as an Emergency mode controller turning on its connected fixture at full brightness when failure of normal power is detected. See the Douglas Lighting Controls BTCC App Field Manual for details.
The BT-LWE Emergency operation can be tested using the iOS mobile device (e.g. iPod Touch) that was used to commission the BT-LWE with the Douglas Lighting Controls BTCC App (BTCC).
To test Emergency operation, perform the following steps: 1. Ensure the emergency circuit is connected to the fixture controlled by the BT-LWE and
is energized. 2. Use a Douglas Lighting Controls Bluetooth switch to turn OFF the BT-LWE, or use the
BTCC "Room Setup" tab on the commissioning mobile device to access control of the device and turn it OFF. 3. Use the BTCC "System Setup" tab on the commissioning mobile device to navigate to the commissioned devices list and select the settings cogwheel for the BT-LWE to test. 4. In the settings page for the BT-LWE, select the "Test Emergency Mode" button on the bottom of the setting page. The BT-LWE will turn on to 100% brightness for approximately 30 seconds. Following the 30 second test, the fixture will remain ON and return to its previous dimming state. The device will resume normal operation, e.g. responding to occupancy and switch control. 5. Use the "Cancel" button in the upper left corner to exit the BT-LWE Settings page WITHOUT writing the configuration parameters.

www.universaldouglas.com Rev. 3/14/22

Page 6

Universal Lighting Technologies



References

Microsoft PowerPoint for Microsoft 365