Instruction Manual for FAAC models including: C720, C721, C720-C721 Residential Low Voltage Slide Gate Opener, C720-C721, Residential Low Voltage Slide Gate Opener, Voltage Slide Gate Opener, Slide Gate Opener, Gate Opener

Manual

FAAC C720 Residential Low Voltage Slide Gate Opener (49ft / 900 lbs.) - FAAC 109322.1 | Fast Gate Openers

C720-C721 - Fast Gate Openers

C720-C721 3 732568 - Rev.E Fig. 1 ENGLISH Translation of the original instructions C720 - C721 We thank you for choosing our products. We are certain that they will fully meet your needs with respect to the performance that

FAAC C721 Low Voltage Commercial Slide Gate Opener (49ft / 1800 lbs.) - FAAC 109321 | Fast Gate Openers


File Info : application/pdf, 12 Pages, 1.79MB

PDF preview unavailable. Download the PDF instead.

C720 C721 Manual 5-24
C720-C721
www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

1) ATTENTION! To ensure the safety of people, it is 14) Make sure that the earthing system is perfectly

important that you read all the following instruc- constructed and connect metal parts of the

tions. Incorrect installation or incorrect use of the closure to it.

product could cause serious harm to people.

15) The automated system is supplied with an intrinsic

2) Carefully read the instructions before beginning anti-crushing safety device consisting of a torque

to install the product.

control. Nevertheless, its tripping threshold must be

3) Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such

checked as specified in the Standards indicated at point 10.

materials are potential sources of danger.

16) The safety devices (EN 12978 standard) protect

4) Store these instructions for future reference.
5) This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the good condition/operation of the product and/ or be a source of danger.
6) FAAC declines all liability caused by improper use or use other than that for which the automated system was intended.
7) Do not install the equipment in an explosive atmosphere: the presence of inflammable gas or fumes is a serious danger to safety.
8) The mechanical parts must conform to the provisions of Standards EN 12604 and EN 12605.
For non-EU countries, to obtain an adequate level of safety, the Standards mentioned above must be observed, in addition to national legal regulations.
9) FAAC is not responsible for failure to observe Good Technique in the construction of the closing elements to be motorised, or for any deformation that may occur during use.

any danger areas against mechanical movement Risks, such as crushing, dragging, and shearing.
17) Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended for every system, as well as a warning sign adequately secured to the frame structure, in addition to the devices mentioned at point "16".
18) FAAC declines all liability as concerns safety and efficient operation of the automated system, if system components not produced by FAAC are used.
19) For maintenance, strictly use original parts by FAAC.
20) Do not in any way modify the components of the automated system.
21) The installer shall supply all information concerning manual operation of the system in case of an emergency and shall hand over to the user the warnings handbook supplied with the product.
22) Do not allow children or adults to stay near the product while it is operating.

10) The installation must conform to Standards EN 12453 23) Keep remote controls or other pulse generators

and EN 12445.

away from children, to prevent the automated

For non-EU countries, to obtain an adequate level

system from being activated involuntarily.

of safety, the Standards mentioned above must be 24) Transit is permitted only when the automated

observed, in addition to national legal regulations.

system is idle.

11) Before attempting any job on the system, cut out electrical power.
12) The mains power supply of the automated system must be fitted with an all-pole switch with contact opening distance of 3 mm or greater. Use of a 6A thermal breaker with all-pole circuit break is recommended.

25) The user must not attempt any kind of repair or direct action whatever and contact qualified personnel only.
26) Check at least every 6 months the efficiency of the system, particularly the efficiency of the safety devices (including, where foreseen, the operator thrust force) and of the release devices.

13) Make sure that a differential switch with threshold 27) Anything not expressly specified in these instruc-

of 0.03 A is fitted upstream of the system.

tions is not permitted.

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

ENGLISH

CE DECLARATION OF CONFORMITY FOR MACHINES
(DIRECTIVE 2006/42/EC)

Manufacturer: FAAC S.p.A.

Address:

Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY

Declares that: Operator mod. C720 - C721

is built to be integrated into a machine or to be assembled with other machinery to create a machine under the provisions of Directive 98/37/EC;

conforms to the essential safety requirements of the following EEC directives:

2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility Directive

and also declares that it is prohibited to put into service the machinery until the machine in which it will be integrated or of which it will become a component has been identified and declared as conforming to the conditions of Directive 2006/42/EEC and subsequent amendments.

Bologna, 01-12-2011

The Managing Director A. Marcellan

Translation of the original instructions

CONTENTS

1 GENERAL REMARKS ........................................................................................................................................ 3 2 DESCRIPTION AND TECHNICAL SPECIFICATIONS ............................................................................................ 3 3 DIMENSIONS .................................................................................................................................................. 4 4 ELECTRIC EQUIPMENT (standard system)....................................................................................................... 4 5 INSTALLATION OF AUTOMATED SYSTEM ......................................................................................................... 4
5.1 PRELIMINARY CHECKS...................................................................................................................................... 4 5.2 MASONRY FOR FOUNDATION PLATE ............................................................................................................... 5 5.3 MECHANICAL INSTALLATION ........................................................................................................................... 6 5.4 INSTALLING THE RACK...................................................................................................................................... 7
5.4.1 STEEL RACK TO WELD (Fig.11) ........................................................................................................................... 7 5.4.3 NYLON RACK TO SCREW (Fig. 13) .................................................................................................................... 7 5.4.2 STEEL RACK TO SCREW (Fig. 12) ....................................................................................................................... 7 6 OPERATIONAL START-UP ................................................................................................................................. 8 6.1 ELECTRONIC BOARD CONNECTION ................................................................................................................. 8 6.1.1 EARTHING ......................................................................................................................................................... 8 6.1.2 ELECTRONIC EQUIPMENT ................................................................................................................................. 8 6.2 POSITIONING OF LIMIT SWITCHES ................................................................................................................... 9 7 TESTING THE AUTOMATED SYSTEM ................................................................................................................. 9 8 OPERATOR RELEASE/LOCK ............................................................................................................................. 9 9 MAINTENANCE ............................................................................................................................................ 10 10 REPAIR ....................................................................................................................................................... 10 11 ACCESSORIES ............................................................................................................................................ 10 11.1 BATTERY KIT .................................................................................................................................................. 10 11.2 RADIO MODULE ............................................................................................................................................ 10

C720-C721

2

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

C720 - C721
We thank you for choosing our products. We are certain that they will fully meet your needs with respect to the performance that have been designed for. These products have been designed and built to control vehicle access. AVOID ANY DIFFERENT USE.
Read this manual provided with the product carefully because it provides important information on safety, installation, use and maintenance.
1 GENERAL REMARKS These instructions apply to the following models:
C720 - C721 The above-mentioned models are electromechanical operators designed for sliding gates with different features and technical specifications. A practical and functional mechanical lock that acts directly on the motor ensures the gate is locked when the operator is not working and, therefore, no electric lock needs to be installed. A convenient manual release device allows the gate to be manoeuvred in the event of a power cut, if emergency batteries are not installed or if the operator is not in service.
These operators, in addition to having different features and technical specifications, also differ as to the following components: motor (larger in the C721), transformer (larger in the C721), pinion (different materials), release lever (different colours). These assembly instructions apply to both models, unless otherwise specified.
2 DESCRIPTION AND TECHNICAL SPECIFICATIONS

ENGLISH

Translation of the original instructions

 



  
 

1. Cover casing 2. Motor lock 3. Link cover 4. Motor release handle 5. Transformer 6. Foundation plate 7. Cable passage holes 8. Pinion and pinion cover 9. Electronic board
Fig. 1

MODEL

C720

C721

Power supply

230 V VERSION : 230 V~ 50 Hz 115V VERSION : 115 V~ 60 Hz

230 V~ 50 Hz

Max. Absorbed power (W)

170

290

Thrust on pinion (N)

320

530

Max. Torque (Nm)

18

30

Type of pinion

Z28 module 4

Z28 module 4

Gate max. recommended length (m)

15

15

Max. leaf weight (Kg)

400

800

Gate speed (m/min)

min 8 max 18

min 8 max 18

Limit switch type

Magnetic

Magnetic

Clutch

Electronic

Electronic

Operating temperature (°C)

-20 +55

-20 +55

Gearmotor weight (kg)

6

10

Protection class

IP44

IP44

Gearmotor dimensions

See Fig.2

See Fig.2

Use frequency

RESIDENTIAL

RESIDENTIAL

C720-C721

3

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

3 DIMENSIONS Dimensions in mm

ENGLISH

Translation of the original instructions

Fig. 2
4 ELECTRIC EQUIPMENT (standard system)

1. Operator

·

¿

2. Flashing lamp 3. 2easy-BUS Photocells

» 4. Conventional photo-

´

cells

³

5. Key-operated control

¿

»

Fig. 3

The dimensions and electrical preparations (standard system) are the same for operator C720 and for operator C721

5 INSTALLATION OF AUTOMATED SYSTEM
5.1 PRELIMINARY CHECKS To ensure safety and an efficiently operating automated system, make sure the following conditions are observed: · The gate structure must be suitable for automation. The following are necessary in particular: wheel diameter must be in
proportion to the weight of the gate to be automated, an upper guide must be provided, plus mechanical limit switches to prevent the gate derailing. · The gate slide track must be linear and horizontal. · Manual movement of the gate must be easy throughout its travel. · The soil must permit sufficient stability for the foundation plinth. · There must be no pipes or electric cables in the plinth excavation area. · If the gearmotor is exposed to passing vehicles, install, if possible, adequate means of protection against accidental impact. · Check if an efficient earthing is available for connection to the gearmotor. If the elements checked do not meet the above requirements, arrange to ensure their compliance.

C720-C721

4

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

ENGLISH

Translation of the original instructions

5.2 MASONRY FOR FOUNDATION PLATE 1. Assemble the foundation plate as shown in Fig. 4.
2. The foundation plate must be located as shown in Fig. 5 (right closing) or Fig. 6 (left closing) to ensure the rack and pinion mesh correctly.

Dimensions in mm

Positioning of plate with GALVANISED STEEL rack
NYLON rack right closure

Dimensions in mm

Fig. 4

Fig. 5

This symbol must always face towards the gate

Positioning of plate with GALVANISED STEEL rack
NYLON rack left closure
3. Prepare a foundation plinth as shown in Fig. 7 and wall in the foundation plate, supplying one or more sheaths for routing electric cables through the hole in the foundation plate. Using a spirit level, check if the plate is perfectly level. Wait for the cement to set.
4. Lay the electric cables for connection to the accessories and power supply as shown in Fig. 3. To facilitate the connections in the control unit, pull out the leads by at least 30 cm from the hole on the plate.

Dimensions in mm
Fig. 6

300

Dimensions in mm Fig. 7

C720-C721

5

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

ENGLISH

5.3 MECHANICAL INSTALLATION 1. Remove the cover casing by loosening the two suitable side bolts and lifting it (Fig. 8). 2. Position the operator on the foundation plate using the nuts and washers provided as shown in Fig. 9. During this operation,
pass the cables though openings in the motor casing (see Fig. 9 re. ).
Fig. 8 and Fig. 9 refer to operator C720





Fig. 8

Fig. 9

3. Adjust the height of the gearmotor and the distance from the gate with reference to the dimensions in Fig. 10.

Operation required for correct fastening of the rack and to keep open the option of new adjustments.

Dimensions in mm with rack in REINFORCED NYLON

Dimensions in mm with rack in GALVANISED STEEL

Translation of the original instructions

4. Secure the gearmotor to the plate by tightening the fastening nuts.
5. Prepare the gearmotor for manual operating mode as described in paragraph 8.

Make sure that the gate, or parts of it, doesn't touch the pinion support during the whole movement.

Fig. 10

C720-C721

6

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

ENGLISH

5.4 INSTALLING THE RACK

5.4.1 STEEL RACK TO WELD (Fig.11)

5.4.2 STEEL RACK TO SCREW (Fig. 12)

1. Place the three threaded pawls on the rack element, posi- 1. Manually take the leaf into its closing position.

tioning them at the top of the slot. In this way, the slot play 2. Lay the first piece of rack level on the pinion and place the

will enable any adjustments to be made.

spacer between the rack and the gate, positioning it at

2. Manually take the leaf into its closing position.

the top of the slot. In this way, the slot play will enable any

3. Lay the first piece of rack level on the pinion and weld the

adjustments to be made.

threaded pawl on the gate as shown in Fig. 14.

3. Mark the drilling point on the gate. Drill a Ø 6.5 mm hole and

4. Move the gate manually, checking if the rack is resting on

apply thread with a Ø 8 mm male tap. Screw the bolt.

the pinion, and weld the second and third pawls.

4. Move the gate manually, checking if the rack is resting on

5. Bring another rack element near to the previous one, using a

the pinion, and repeat the operations at point 3.

piece of rack (as shown in Fig. 15), to synchronise the teeth 5. Bring another rack element near to the previous one, using

of the two elements.

a piece of rack (as shown in figure 15) to synchronise the

6. Move the gate manually and weld the three threaded pawls,

teeth of the two elements.

thus proceeding until the gate is fully covered.

6. Move the gate manually and carry out the securing opera-

tions as for the first element, thus proceeding until the gate

is fully covered.

Fig. 11
5.4.3 NYLON RACK TO SCREW (Fig. 13) 1. Manually take the leaf into its closing position. 2. Lay the first piece of the rack level on the pinion and mark
the drilling point on the gate; drill Ø 5.2 mm and screw in the self-tapping screw provided with its reinforcing plate. 3. Move the gate manually, checking if the rack is resting on the pinion, and repeat the operations at point 2. 4. Couple another rack element and fit to the previous element. 5. Move the gate manually and carry out the securing operations as for the first element, thus proceeding until the gate is fully covered.

Fig. 12 Fig. 13

Translation of the original instructions

Fig. 14

Fig. 15

C720-C721

7

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

Important notes on rack installation:
Make sure that, during the gate travel, all the rack elements do not exit the pinion.
Do not, on any account, weld the rack elements either to the spacers or to each other.
When the rack has been installed, to ensure it meshes correctly with the pinion, we advise you to lower the gearmotor position by about 1.5 - 2 mm by adjusting the nuts (Fig.16 re. ).
Do not use grease or other lubricants between rack and pinion (Fig. 16)
Manually check if the gate regularly reaches the mechanical limit switches and make sure there is no friction during gate travel.

6 OPERATIONAL START-UP
6.1 ELECTRONIC BOARD CONNECTION
Before attempting any work on the control board (connections, programming, maintenance), always turn off power.
· Observe points 10, 11, 12, 13, 14 of the GENERAL

SAFETY OBLIGATIONS.

OFF

· Follow the instructions in Fig. 3 to arrange the cables

in the ducts and make the electrical connections

with the selected accessories.

· Always separate power cables from control and safety ca-

bles (push-button, receiver, photocells, etc.).

· Use separate sheaths in order to avoid any electrical inter-

ference.

6.1.1 EARTHING Connect the earth cable as described in Fig.17.
Fig. 17

ENGLISH

Translation of the original instructions


Dimensions in mm

Fig. 17 refers to operator C720
6.1.2 ELECTRONIC EQUIPMENT The electronic control equipment in the gearmotors is fastened to a mount (Fig. 18 re. ) with a clear cover (Fig. 18 re. ). The board programming buttons are positioned on the cover (Fig.18 re. ) and this makes it possible to programme the board without having to remove the cover.
To connect and program the control unit correctly, observe the specific instructions.
Fig. 16
 


Fig. 18

C720-C721

8

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

6.2 POSITIONING OF LIMIT SWITCHES To ensure correct positioning of the limit switch magnets, the control unit must be installed and correctly connected with all control and safety accessories .
The operator is equipped with a magnetic limit switch sensor built directly into the electronic control board. The gate is stopped, during opening or closure, at the moment when the polarised magnet secured to the upper part of the rack activates the sensor. Assemble both magnets as shown in Fig. 19. Prepare the operator for manual operating mode as described in chapter 8 and power the system.
Fig. 19

ENGLISH

Translation of the original instructions

To position the limit switch on the rack, refer to the electronic equipment instructions.
To avoid damage to the operator and/or interruptions in the operation of the automated system, approximately 40 mm must be left from the mechanical limit switches.

7 TESTING THE AUTOMATED SYSTEM

Once the operator has been installed, carry out a thorough

operational check of all accessories and connected safety

devices.



Press-fit the plastic covers of the operator fastening bolts, ensuring

that the arrow is facing the gate (Fig. 20 re. ), insert the cover

casing (Fig. 20 re. ) and fasten it by the two suitable side bolts

(Fig. 20 re. ).

Give the Customer the "User Guide" and explain the correct op-

eration and use of the gearmotor, highlighting potential high-risk

areas of the automated system.

8 OPERATOR RELEASE/LOCK



During the release/lock manoeuvre, take care to prevent an involuntary pulse from operating the gate.

Proceed as follows to release the gearmotor:

1. Turn the release clockwise as shown in Fig. 21 re. . The

release lever will move slightly away from the operator body

(Fig. 21 re. )

2. Fully lower the release lever to the mechanical stop Fig. 21



re. .

3. Carry out the opening or closing manoeuvre manually.







Fig. 20

Fig. 21

C720-C721

9

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

Proceed as follows to lock the gearmotor: 1. Fully raise the release lever to the mechanical stop, Fig. 22
re. . 2. Turn the release anticlockwise as shown in Fig. 22 re. .
To maintain the operator intact, avoid pulsing the gate to operate before resetting the lock system.

9 MAINTENANCE It is advisable to check the efficiency of the system at least every 6 months, particularly the efficiency of the safety devices (including the motor thrust force, which must comply with current standards) and of the release devices.
10 REPAIR Contact an authorised Repair Centre for repairs.

11 ACCESSORIES



11.1 BATTERY KIT

Install the battery kit as shown in Fig. 24, inserting it in its seat and

securing with screw re. . Connect it to the appropriate con-

nector on the board (see relevant instructions).

Refer to the specific instructions for all information on the bat-

tery kit.





ENGLISH

Translation of the original instructions

Fig. 22
Lowering the release lever, both the motor lock, which is retracted (Fig. 23 re. ), and the safety microswitch forcing the automation to STOP (Fig. 23 re. ) are operated.

11.2 RADIO MODULE Install the radio module as shown in Fig. 25.

Fig. 24

³ ·

Fig. 23

Fig. 25

C720-C721

10

732568 - Rev.E

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com

C720 - C721 USER GUIDE







Fig. 1

Read the instructions carefully before using the 
product and keep for any future needs.



GENERAL SAFETY REGULATIONS The C720 and C721 automated systems, if correctly installed and used, guarantee a high level of safety. Obeying some simple rules can also prevent accidental problems: · Do not allow children or adults to stay near the
automated system, particularly avoid it while it is operating.
· Keep radiocontrols or other pulse generators away from children, to prevent the automated system from being activated involuntarily.
· Do not allow children to play with the automated system.
· Do not forcibly restrain the gate's movement.
· Prevent branches or shrubs from interfering with gate movement.
· Keep the illuminated signalling systems efficient and very visible.
· Do not attempt to operate the gate by hand until it has been released.
· In the event of malfunction, release the gate to allow access and wait for qualified technical personnel to repair it.
· Once manual operating mode has been set, turn off the power supply to the system before restoring normal operation.
· Do not in any way modify the components of the automated system.
· The user must not attempt any kind of repair or direct action whatever and contact qualified personnel only.
· Ensure the efficiency of the automated device, the safety devices and the earth connection are checked at least every six months by qualified personnel.
DESCRIPTION The C720 and C721 automated systems are ideal for controlling vehicle access areas with average transit frequency. The C720 and C721 automated systems for sliding gates are electromechanical operators that transmit the motion to the sliding leaf using a rack and pinion. The operation of the sliding gate is managed by an electronic control device housed inside the operator or in a watertight outdoor container. When the device receives an opening command via a radiocontrol or any other suitable device with the gate closed, it operates the motor until the gate reaches its open position. If automatic operation has been selected, the gate re-closes by itself after the selected pause time. If semi-automatic operating mode has been selected, a second pulse must be sent to re-close the gate. An opening pulse issued during the re-closing stage always causes a reversal of motion. A stop pulse (if applicable) always stops motion. The warning light indicates the current gate movement. For the detailed behaviour of the sliding gate during the various operating modes, consult the installing technician. The automated systems contain obstacle detection and/or safety devices (photocells, edges) that prevent the gate closing when an obstacle is located in the scanned area.

Fig. 2
The system ensures the gate is mechanically locked when the motor is not operating and no lock therefore needs to be installed. Manual opening is therefore only possible if the appropriate release system is operated. The gearmotor is equipped with a device with electronic anticrushing system that offers the necessary safety if the gate should strike an obstacle during its motion by causing it to reverse direction immediately. A handy manual release makes it possible to move the gate in the event of a power cut (if no back-up batteries are installed) or malfunction.
MANUAL OPERATION
During the release/lock manoeuvre, take care to prevent an involuntary pulse from operating the gate.
Proceed as follows to release the gearmotor: 1. Turn the release clockwise as shown in Fig. 1 re. . The
release lever will move slightly away from the operator body (Fig. 1 re. ) 2. Fully lower the release lever to the mechanical stop Fig. 1 re. . 3. Carry out the opening or closing manoeuvre manually.
RESTORING NORMAL OPERATION Proceed as follows to lock the gearmotor: 1. Fully raise the release lever to the mechanical stop, Fig. 2
re. . 2. Turn the release anticlockwise as shown in Fig. 2 re. .
To maintain the operator intact, avoid pulsing the gate to operate before resetting the release system.
MAINTENANCE It is advisable to check the efficiency of the system at least every 6 months, particularly the efficiency of the safety devices (including the motor thrust force, which must comply with current standards) and of the release devices.
REPAIRS Contact an authorised Repair Centre for repairs.
AVAILABLE ACCESSORIES Refer to the catalogue for the available accessories.

www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com



References

iLovePDF