3. INSTALLATION AND MAINTENANCE. 3-1. AC Output Side (Front Panel) Introduction 3-1-1. Main Switch 3-1-2. LED Indicator 3-1-3. Function Switch Introduction 3-1-4. TRC Port (for optional kits...
3. INSTALLATION AND MAINTENANCE. 3-1. AC Output Side (Front Panel) Introduction 3-1-1. Main Switch 3-1-2. LED Indicator 3-1-3. Function Switch Introduction 3-1-4. TRC Port.. View
SP Series User's Manual SP-700/1000/1500/2000/3000/4000 PURE SINE WAVE INVERTER Table of Content 1. SAFETY INSTRUCTIONS 1 1-1. General Safety Precautions 1 1-2. Other Safety Notes 2 2. FUNCTIONAL CHARACTERISTICS INTRODUCTION 3 2-1. System 3 2-2. Block Diagram 3 2-3. Electrical Specification 4 2-3-1. SP-700 Specification 4 2-3-2. SP-1000 Specification 6 2-3-3. SP-1500 Specification 8 2-3-4. SP-2000 Specification 10 2-3-5. SP-3000 Specification 12 2-3-6. SP-4000 Specification 14 2-3-7. Voltage & temperature performance 16 2-4. Mechanical Drawings 17 3. INSTALLATION AND MAINTENANCE 18 3-1. AC Output Side (Front Panel) Introduction 18 3-1-1. Main Switch 19 3-1-2. LED Indicator 19 3-1-3. Function Switch Introduction 20 3-1-4. TRC Port (for optional kits TR-40, RJ-45) 21 3-1-5. AC output Interface 22 3-2. DC Input Side (Rear Panel) Introduction 24 3-2-1. Remote Port (RJ-11) 25 3-2-2. Remote Control Green Terminal 25 3-2-3. General instruction before DC Input 26 3-2-4. Chassis Ground 27 3-3. Maintenance 27 4. OPERATION 28 4-1. Connection the DC cable 28 4-2. Connecting the input power 29 4-3. Connecting the loads 29 4-4. Switch ON Inverter 29 4-5. Protection Mechanism 30 5. RS-232 COMMUNICATION AND OPERATION 30 5-1. RS-232 Port 30 5-2. RS-232 Port Operating 31 5-3. Example of RS-232 Port Operating 31 5-3-1. RS-232 command format 31 5-3-2. Command format 31 6. INFORMATION 36 6-1. Warning 36 6-2. Warranty 36 1. Safety Instructions 1-1. General Safety Precautions Warning! Before using the Inverter, read the safety instructions. z Do not expose the inverter to rain, snow, spray or dust. To reduce the risk of fire hazard, do not cover or obstruct the ventilation openings and do not install the inverter in a zero-clearance compartment. z To avoid the risk of fire and electric shock, make sure that the existing wiring is in good electrical condition, and the wire size is not undersized. z This equipment contains components which can produce arcs or sparks. To prevent fire or explosion do not install in compartment containing batteries or flammable materials or in location which require ignition protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, or joints, fittings, or other connection between components of the fuel system. z Depending on the user scenario, the AC output of the inverter may require user installed breaker or fuse. In AC output hardwire application, AC socket will not been provided. The inverter incorporates standard AC short circuit protection. z An over current protection at the time of installation shall be provided by others for the AC output circuit. z Additional breakers suitable for 20 A branch circuit protection shall be provided for the GFCI receptacles. z The following precautions should be taken when working on the inverter: Step 1 Remove watches, rings, or other metal objects Step 2 Use tools with insulated handles Step 3 Wear rubber gloves and boots 1 1-2. Other Safety Notes z Upon receipt, examine the carton box for damage. If you have found any damage on the carton box please notify the company you purchased this unit from. z Do not operate near water or in excessive humidity. z Do not open or disassemble the inverter, and warranty may be voided. z The DC side connections should be firm and tight. z Grounding: Reliable grounding should be maintained. z Do not drop a metal tool on the battery. The resulting spark or short-circuit on the battery or on the other electrical part may cause an explosion. z Install the inverter in a well-ventilated area. Do not block the front air vents, or the rear air exhausts of the unit. z Wiring: Adequate input power must be supplied to the inverter for proper use; correct wiring sizes must be ensured. z Mount the inverter such that the fan axis is horizontal. z Do not operate the inverter close to combustible gas or open fire. z Do not operate appliances that may feed power back into the inverter. z Temperature: The inverter should be operated in an ambient temperature range of -20 to 40 otherwise the output efficiency may be affected. Air flow to the inverter must not be blocked. 2 2. Functional Characteristics Introduction 2-1. System The unit is a highly reliable DC-AC inverter system, designed with advanced power electronic and microprocessor technology offering the following features: z Pure sine wave output waveform O/P voltage 1xx THD < 5 %, 2xx THD < 3 % z Optional bypass relay (TR-40) function z Intelligent software for power management z Loading and temperature controlled cooling fan z CR-8/CR-16 remote management and control z RS-232 communication z Dry contact terminal z Advanced Protection Features ¾ Input over/under voltage protection ¾ Internal over temperature protection ¾ Input reverse polarity protection (Fuse) ¾ Output overload protection ¾ Output short circuit protection 2-2. Block Diagram 3 2-3. Electrical Specification 2-3-1. SP-700 Specification Electrical Input Characteristics Output Characteristics Signal and Control Protection Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-700-112 12VDC 16.5 ± 0.3VDC Model No. SP-700-124 24VDC 33 ± 0.5VDC SP-700-148 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5VDC 1.5A @12VDC <0.1A @12VDC 21 ± 0.5VDC 21~33VDC 0.8A @24VDC <0.06A @24VDC 700 VA (± 3%) 42 ± 1.0VDC 42~66VDC 0.5A @48VDC <0.05A @48VDC > 700 VA~810 VA (100%~115%) < 1230 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 100 / 110 / 115 / 120 VAC (± 5%) (Dip Switch Selectable) 91% 93% 93% 1 Sec Shutdown Pure Sine Wave (THD < 5%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified UL 458 (UL only for GFCI receptacles) ---- Certified FCC class B ---- 200mm X 83mm X 330mm 2.6 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Note Table 1. SP-700 for Output 100/110/115/120 VAC Specification. M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 4 Electrical Input Characteristics Output Characteristics Specification Item Voltage Input Over-Voltage Protection M Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Signal and Control Protection Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-700-212 12VDC 16.5 ± 0.3VDC Model No. SP-700-224 24VDC 33 ± 0.5VDC SP-700-248 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5VDC 1.5A @12VDC <0.1A @12VDC 21 ± 0.5VDC 21~33VDC 0.8A @24VDC <0.06A @24VDC 700 VA (± 3%) 42 ± 1.0VDC 42~66VDC 0.5A @48VDC <0.05A @48VDC > 700 VA~810 VA (100%~115%) < 1230 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 200 / 220 / 230 / 240 VAC (± 3%) (Dip Switch Selectable) 91% 93% 94% 1 Sec Shutdown Pure Sine Wave (THD < 3%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified EN 60950-1 Certified EN 55022 class B; EN 55024; EN 61000-3-2, -3-3 EN 61000-4-2, 3, 4, 5, 6, 8, 11 Certified CISPR 25; ISO 7637-2 200mm X 83mm X 330mm 2.6 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Note Table 2. SP-700 for Output 200/220/230/240 VAC Specification. M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 5 2-3-2. SP-1000 Specification Electrical Input Characteristics Output Characteristics Signal and Control Protection Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-1000-112 12VDC 16.5 ± 0.3VDC Model No. SP-1000-124 24VDC 33 ± 0.5VDC SP-1000-148 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 1.5A @12VDC <0.1A @12VDC 21 ± 0.5VDC 21~33 VDC 0.8A @24VDC <0.06A @24VDC 1000 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 0.5A @48VDC <0.05A @48VDC > 1000 VA~1150 VA (100%~115%) < 1750 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 100 / 110 / 115 / 120 VAC (± 5%) (Dip Switch Selectable) 92% 93% 93% 1 Sec Shutdown Pure Sine Wave (THD < 5%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified UL 458 (UL only for GFCI receptacles) ---- Certified FCC class B ---- 200mm X 83mm X 372mm 3.26 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 3. SP-1000 for Output 100/110/115/120 VAC Specification. Note M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 6 Electrical Input Characteristics Output Characteristics Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Signal and Control Protection Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-1000-212 12VDC 16.5 ± 0.3VDC Model No. SP-1000-224 24VDC 33 ± 0.5VDC SP-1000-248 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 1.5A @12VDC < 0.1A @12VDC 21 ± 0.5VDC 21~33 VDC 0.8A @24VDC <0.05A @24VDC 1000 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 0.4A @48VDC <0.05A @48VDC > 1000 VA~1150 VA (100%~115%) < 1750 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 200 / 220 / 230 / 240 VAC (± 3%) (Dip Switch Selectable) 92% 94% 94% 1 Sec Shutdown Pure Sine Wave (THD < 3%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified EN 60950-1 Certified EN 55022 class B; EN 55024; EN 61000-3-2, -3-3 EN 61000-4-2, 3, 4, 5, 6, 8, 11 Certified CISPR 25; ISO 7637-2 200mm X 83mm X 372mm 3.26 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 4. SP-1000 for Output 200/220/230/240 VAC Specification. Note M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 7 2-3-3. SP-1500 Specification Electrical Input Characteristics Output Characteristics Signal and Control Protection Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-1500-112 12VDC 16.5 ± 0.3VDC Model No. SP-1500-124 24VDC 33 ± 0.5VDC SP-1500-148 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 1.8A @12VDC <0.1A @12VDC 21 ± 0.5VDC 21~33 VDC 1.0A @24VDC <0.05A @24VDC 1500 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 0.5A @48VDC <0.05A @48VDC > 1500 VA~1730VA (100%~115%) <2650 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 100 / 110 / 115 / 120 VAC (± 5%) (Dip Switch Selectable) 91% 92% 93% 1 Sec Shutdown Pure Sine Wave (THD < 5%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified UL 458 (UL only for GFCI receptacles) ---- Certified FCC class B ---- 248mm X 83mm X 421mm 4.14 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 5. SP-1500 for Output 100/110/115/120 VAC Specification. Note M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=100/110/115/120VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 8 Electrical Input Characteristics Output Characteristics Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Signal and Control Protection Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-1500-212 12VDC 16.5 ± 0.3VDC Model No. SP-1500-224 24VDC 33 ± 0.5VDC SP-1500-248 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 1.8A @12VDC <0.1A @12VDC 21 ± 0.5VDC 21~33 VDC 1.0A @24VDC <0.05A @24VDC 1500 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 0.5A @48VDC <0.05A @48VDC > 1500 VA~1730VA (100%~115%) <2650 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 200 / 220 / 230 / 240 VAC (± 3%) (Dip Switch Selectable) 93% 94% 94% 1 Sec Shutdown Pure Sine Wave (THD < 3%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified EN 60950-1 Certified EN 55022 class B; EN 55024; EN 61000-3-2, -3-3 EN 61000-4-2, 3, 4, 5, 6, 8, 11 Certified CISPR 25; ISO 7637-2 248mm X 83mm X 421mm 4.14 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 6. SP-1500 for Output 200/220/230/240 VAC Specification. Note M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 9 2-3-4. SP-2000 Specification Electrical Input Characteristics Output Characteristics Signal and Control Protection Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-2000-112 12VDC 16.5 ± 0.3VDC Model No. SP-2000-124 24VDC 33 ± 0.5VDC SP-2000-148 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 1.8A @12VDC <0.1A @12VDC 21 ± 0.5VDC 21~33 VDC 1.0A @24VDC <0.05A @24VDC 2000 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 0.5A @48VDC <0.05A @48VDC > 2000 VA~2300 VA (100%~115%) < 3500 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 100 / 110 / 115 / 120 VAC (± 5%) (Dip Switch Selectable) 92% 93% 94% 1 Sec Shutdown Pure Sine Wave (THD < 5%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified UL 458 (UL only for GFCI receptacles) ---- Certified FCC class A ---- 248mm X 83mm X 443mm 5.24 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 7. SP-2000 for Output 100/110/115/120 VAC Specification. Note M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 P Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 10 Electrical Input Characteristics Output Characteristics Signal and Control Protection Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-2000-212 12VDC 16.5 ± 0.3VDC Model No. SP-2000-224 24VDC 33 ± 0.5VDC SP-2000-248 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 1.8A @12VDC <0.1A @12VDC 21 ± 0.5VDC 21~33 VDC 1.0A @24VDC <0.05A @24VDC 2000 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 0.5A @48VDC <0.05A @48VDC > 2000 VA~2300 VA (100%~115%) < 3500 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 200 / 220 / 230 / 240 VAC (± 3%) (Dip Switch Selectable) 94% 94% 95% 1 Sec Shutdown Pure Sine Wave (THD < 3%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified EN 60950-1 Certified EN 55022 class A; EN 55024; EN 61000-3-2, -3-3 EN 61000-4-2, 3, 4, 5, 6, 8, 11 Certified CISPR 25; ISO 7637-2 248mm X 83mm X 443mm 5.24 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 8. SP-2000 for Output 200/220/230/240 VAC Specification. Note M Voltage range Please refer to Figure 1 N Normal load Condition Vin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 2 P Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 11 2-3-5. SP-3000 Specification Electrical Input Characteristics Output Characteristics Signal and Control Protection Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Operating Temp. Environment Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-3000-112 12VDC 16.5 ± 0.3VDC Model No. SP-3000-124 24VDC 33 ± 0.5VDC SP-3000-148 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 3.8A @12VDC <0.4A @12VDC 21 ± 0.5VDC 21~33 VDC 2.0A @24VDC <0.2A @24VDC 3000 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 1.0A @48VDC <0.1A @48VDC > 3000 VA~3450 VA (100%~115%) < 6000 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 100 / 110 / 115 / 120 VAC (± 5%) (Dip Switch Selectable) 90% 91% 92% 1 Sec Shutdown Pure Sine Wave (THD < 5%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified UL 458 ---- Certified FCC class A ---- 255mm X 158mm X 442mm 8.2 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Note Table 9. SP-3000 for Output 100/110/115/120 VAC Specification. M Voltage range Please refer to Figure 3 N Normal load Condition Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 4 P Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 12 Electrical Input Characteristics Output Characteristics Signal and Control Protection Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Environment Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories SP-3000-212 12VDC 16.5 ± 0.3VDC Model No. SP-3000-224 24VDC 33 ± 0.5VDC SP-3000-248 48VDC 66 ± 1.0VDC 10.5 ± 0.3VDC 10.5~16.5 VDC 3.8A @12VDC <0.4A @12VDC 21 ± 0.5VDC 21~33 VDC 2.0A @24VDC <0.2A @24VDC 3000 VA (± 3%) 42 ± 1.0VDC 42~66 VDC 1.0A @48VDC <0.1A @48VDC > 3000 VA~3450 VA (100%~115%) < 6000 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 200 / 220 / 230 / 240 VAC (± 3%) (Dip Switch Selectable) 90% 93% 94% 1 Sec Shutdown Pure Sine Wave (THD < 3%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified EN 60950-1 Certified EN 55022 class A; EN 55024; EN 61000-3-2, -3-3 EN 61000-4-2, 3, 4, 5, 6, 8, 11 Certified CISPR 25; ISO 7637-2 255mm X 158mm X 442mm 8.2 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 10. SP-3000 for Output 200/220/230/240 VAC Specification. Note M Voltage range Please refer to Figure 3 N Normal load Condition Vin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 4 P Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 13 2-3-6. SP-4000 Specification Electrical Input Characteristics Output Characteristics Signal and Control Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Protection Input Protection AC Output Protection Others Operating Temp. Environment Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories Model No. SP-4000-124 SP-4000-148 24VDC 48VDC 33 ± 0.5VDC 66 ± 1.0VDC 21 ± 0.5VDC 42 ± 1.0VDC 21~33 VDC 42~66 VDC 2.0A @24VDC 1.0A @48VDC <0.2A @24VDC <0.1A @48VDC 4000 VA (± 3%) > 4000 VA~4600 VA (100%~115%) < 8000 VA 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 100 / 110 / 115 / 120 VAC (± 5%) (Dip Switch Selectable) 91% 91% 1 Sec Shutdown Pure Sine Wave (THD < 5%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified UL 458 ---- Certified FCC class A ---- 255mm X 158mm X 462mm 10 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 11. SP-4000 for Output 100/110/115/120 VAC Specification. Note M Voltage range Please refer to Figure 3 N Normal load Condition Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 4 P Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 14 Electrical Input Characteristics Specification Item Voltage Input Over-Voltage ProtectionM Input Under-Voltage Protection Voltage Range No Load Current Power Saving Mode Continuous Output Power Maximum output Power (1Min) Surge Power (1Sec) Model No. SP-4000-224 SP-4000-248 24VDC 48VDC 33 ± 0.5VDC 66 ± 1.0VDC 21 ± 0.5VDC 42 ± 1.0VDC 21~33 VDC 42~66 VDC 2.0A @24VDC 1.0A @48VDC <0.2A @24VDC <0.1A @48VDC 4000 VA (± 3%) > 4000 VA~4600 VA (100%~115%) < 8000 VA Output Characteristics Signal and Control Protection Environment Frequency Output Voltage Efficiency max. Short-Circuit Protection Output Waveform Remote Controller Panel Unit LED Indicator Dry Contact Terminal Remote Control Terminal Input Protection AC Output Protection Others Operating Temp. Storage Temp. Storage Temp. & Humidity Safety Standards Safety & EMC EMC standards E-mark Dimension(WxHxD) Weight Cooling AC Transfer Function Accessories 50 / 60 Hz ± 0.5% (Dip Switch Selectable) 200 / 220 / 230 / 240 VAC (± 3%) (Dip Switch Selectable) 90% 91% 1 Sec Shutdown Pure Sine Wave (THD < 3%@ Normal Load)N CR-8 / CR-16 (optional) Red / Orange / Green LED By a relay 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity (Internal Fuse) Short-Circuit, Overload Over / Under Temperature Protection (by Heat sink Temperature +80 /-20 ) -20 ~40 O -30 ~70 10 ~95% RH Certified EN 60950-1 Certified EN 55022 class A; EN 55024; EN 61000-3-2, -3-3; EN 61000-4-2, 3, 4, 5, 6, 8, 11 Certified CISPR 25; ISO 7637-2 255mm X 158mm X 462mm 10 KG Temperature & Load Controlled cooling Fan TR-40 (optional) Table 12. SP-4000 for Output 100/110/115/120 VAC Specification. Note M Voltage range Please refer to Figure 3 N Normal load Condition Vin =25V/50V, Vo=200/220/230/240 VAC 80% Full load (PF=1.0) O Operating temperature Please refer to Figure 4 P Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 15 Power (W) Power (W) 2-3-7. Voltage & temperature performance 175% 115% 100% 1 Sec 1 Min Continue 1 Sec 0% 10.5V 21V 42V 16V 16.5V 32V 33V 64V 66V Voltage (V) SP-700~2000 Power / Voltage Curve Figure 1. SP-700~2000 Output power vs. input voltage 175% 1 Sec 115% 100% 40% 1 Min Continue Output Power 0% -20oC 0oC 40oC 60oC Temperature (oC) SP700-2000 Power / Temperature Curve Figure 2. SP-700~2000 Output power vs. temperature 200% 115% 100% 1 Sec 1 Min Continue 1 Sec 0% 10.5V 21V 42V 16V 16.5V 32V 33V 64V 66V Voltage (V) SP-3000/4000 Power / Voltage Curve Figure 3. SP-3000/4000 Output power vs. input voltage 200% 1 Sec 115% 100% 40% 1 Min Continue Output Power 0% -20oC 0oC 40oC 60oC Temperature (oC) SP3000-4000 Power / Temperature Curve Figure 4. SP-3000/4000 Output power vs. temperature Power (W) Power (W) 16 2-4. Mechanical Drawings AC Output Side AC Output Side B B E E C A C A DC Input Side D SP-700/1000 Figure 5. SP series drawing (Top View) DC Input Side D SP-1500/2000/3000/4000 F F Figure 6. SP series drawing (AC output/Front View) Model SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 A (mm) 330 372 421 443 442 462 B (mm) 80 69 92 103 103 113 C (mm) 132 196 196 196 196 196 D (mm) 200 200 248 248 255 255 Table 13. SP Series Dimension E (mm) 7.0 7.0 7.0 7.0 7.0 7.0 F (mm) 83 83 83 83 158 158 17 3. Installation and Maintenance 3-1. AC Output Side (Front Panel) Introduction A B E C D F Figure 7. SP-700/1000 AC output panel view A B E C D F Figure 8. SP-1500/2000 AC output panel view A B C E D F Model A B C D E F Figure 9. SP-3000/4000 AC output panel view SP-700 SP-1000 SP-1500 Saving power adjustment Function switch Function LED TRC port (RJ-45) Main switch AC output socket SP-2000 SP-3000 SP-4000 AC output terminal Table 14. SP Series AC output side introduction 18 3-1-1. Main Switch The 3-stage switch remote mode. is for turning on, turning off and 3-1-2. LED Indicator 3-1-2-1. Input voltage level: to display Input Voltages LED status DC 12V DC 24V DC 48V Red Orange < 11.0V 11.0 ~ 11.5V < 22.0V 22.0 ~ 23.0V < 44.0V 44.0~46.0V Green Orange Red 11.5 ~ 15.0V 15.0 ~ 15.5V >15.5V 23.0 ~ 30.0V 30.0 ~ 31.0V >31.0V 46.0~60.0V 60.0~62.0V >62.0V Table 15. Input Voltage Level LED Indicator 3-1-2-2. Output Load Level to display AC Loads (PF=1) LED status SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Green 0 ~ 700 VA 0 ~ 1000 VA 0 ~ 1500 VA 0 ~ 2000 VA 0 ~ 3000 VA 0 ~ 4000 VA Orange 700 ~ 805 VA 1000 ~ 1150 VA 1500 ~ 1725 VA 2000 ~ 2300 VA 3000 ~ 3450 VA 4000 ~ 4600 VA Red > 805 VA > 1150 VA > 1725 VA > 2300 VA > 3450 VA > 4600 VA Table 16. Output Load Level LED Indicator 3-1-2-3. Inverter Status to display Fault condition LED status Green Red Red Blink Red Fast Blink Status Normal Over Current Protection / Over Load Protection (AC output short-circuit and over load) Under Voltage Protection (Input DC voltage under spec) Over Voltage Protection (Input DC voltage over spec) Recovery point 12.5V @ DC12V system 25V @ DC24V system 50V @ DC48V system 14.5V @ DC12V system 29V @ DC24V system 58V @ DC48V system 19 LED status Orange Orange Fast Blink Orange Slow Blink Status Device startup process abnormal Under Temperature Protection (Heat sink temp. under -20 ) Over Temperature Protection (Heat sink temp. over 80 ) Recovery point -- >0 < 60 (heat sink temperature) Table 17. Inverter LED Status Indicator 3-1-3. Function Switch Introduction Figure 10. DIP switch ON/OFF position 3-1-3-1. Function Switch Definition Dip Switch S1 S2 S3 S4 Function Voltage select Voltage select Frequency Select Power saving ON/OFF Table 18. Function Switch Definition 3-1-3-2. Output voltage selection (S1&S2) Output voltage S1 S2 100V/200V OFF OFF 110V/220V ON OFF 115V/230V OFF ON 120V/240V ON ON Table 19. Function Switch definition: output voltage selection Note! 100V series can be selected between 100/110/115/120VAC, and 200V series can be selected between 200/220/230/240VAC. 20 3-1-3-3. Output Frequency Selection (S3) Frequency S3 50Hz OFF 60Hz ON Table 20. Function Switch definition: Output Frequency selection 3-1-3-4. Power Saving Selection (S4) Saving function S4 Power Saving OFF OFF Power Saving ON ON Table 21. Function Switch definition: Power Saving selection 3-1-3-5. Power Saving Load Adjustment User can use variable resistor (VR) to set the input and wake up power saving threshold according to the load condition, and the setting range shows below: SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Input Saving Power (Min) <20 VA <20 VA <20 VA <20 VA <40 VA <40 VA Saving Wake up Power (Min) >40 VA >40 VA >40 VA >40 VA >60 VA >60 VA SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Table 22. Power saving setting range (Min) Input Saving Power (Max) <110 VA <110 VA Saving Wake up Power (Max) >160 VA >160 VA <110 VA <110 VA >160 VA >160 VA <240 VA <240 VA >280 VA >280 VA Table 23. Power saving setting range (Max) 3-1-4. TRC Port (for optional kits TR-40, RJ-45) Pin Number 1 2 3 Signal Description Reserved -- PH-L Zero-Crossing Signal PH-N Zero-Crossing Signal 21 Pin Number 4 5 6 7 8 Signal Description D Bypass Transfer Relay Driver Signal 12V Internal power for TR40 controller 5V Internal power for TR40 controller GND The same polarity as the battery negative side Reserved -- Table 24. SP Series TRC Port : RJ-45. TR-40 SP Series TRC Inverter Input Output Breaker AC Input Load TRC AC Output Figure 11. Wiring between SP series and TR-40 Note! The detail information please refer to TR-40 user manual 3-1-5. AC output Interface 3-1-5-1. SP-700/1000/1500/2000 AC output interface Socket Type Applicable Model North America (GFCI) NEMA 5-15R SP-700/1000-112/124/148 North America (GFCI) NEMA 5-15R SP-1500/2000-112/124/148 22 Socket Type F Applicable Model SP-700/1000/1500/2000/3000- Australia / New Zealand Continental European UK 212/224/248 Universal SP-700/1000/1500/2000-112/124/148 SP-700/1000/1500/2000/3000- 212/224/248 Hard Wire SP-3000-112/124/148/212/224/248 SP-4000-124/148/224/248 France Connector SP-700/1000/1500/2000/3000212/224/248 Table 25. SP Series AC Socket vs. Model 3-1-5-2. SP-3000/4000 AC output interface Terminal F Line (L) AC terminal Neutral (N) FG (Ground) Wire color Black White Green / Yellow or Bare copper Wire length / gauge Within 6 feet / AWG# 200-240VAC: AWG10 100-120VAC: AWG8 26~32 feet / AWG# 10 ~ 8 Table 26. SP-3000/4000 Series AC output wiring 3-1-5-3. GFCI connector Recommend GFCI connector HUBBELL INC WIRING DEVICE DIV, Type GF20 and GFRST20. Rated 125V, 20A COOPER WIRING DEVICES, Type VGF20 and SGF20. Rated 125V, 20A LEVITON MFG CO INC, Type 7899-W and GFNT2. Rated 125V, 20A PASS & SEYMOUR INC, Type 2097. Rated 125V, 20A 23 3-2. DC Input Side (Rear Panel) Introduction 1 2 4 3 Figure 12. SP-700/1000 1 4 23 4 Figure 13. SP-1500/2000 1 2 3 Model 4 4 Figure 14. SP-3000/4000 SP-700 SP-1000 SP-1500 Remote port (RJ-11) Remote control green terminal Chassis ground DC input connector SP-2000 SP-3000 Table 27. SP Series DC input side introduction SP-4000 24 3-2-1. Remote Port (RJ-11) The SP Series Inverter can be compatible with CR-8, and CR-16 remote control via RS-232 Communication. Before using the remote control, make sure the main switch on inverter must be at " REMOTE" position. Pin Number 1 2 3 4 5 6 Signal Description Reserved -- GND The same polarity as the battery negative side RXD RS-232 RXD TXD RS-232 TXD RMT Remote controller panel (positive) VCC Internal power for remote controller Table 28. SP Series Remote Port : RJ-11 3-2-2. Remote Control Green Terminal Remote control green terminal may be connected to a Form C relay for "FAULT" indication. When "FAULT" occurs, the relay switches. Item 1 2 3 Figure 15. Remote control terminal Description Item Description Dry contact (Normal Open) 4 Enable+ (ENB) Common 5 Enable- ( ) Dry contact (Normal Closed) 6 Ground Table 29. Dry contact terminal definition Note! Pin-6 is the same polarity with battery negative electrode. 25 Note! Fault conditions include Input under / over voltage, output short circuit / over load, over / under temperature. Caution! Please follow the following steps for the installation z Before installing the inverter, make sure the main switch is at "OFF" position. z Before using the remote function, make sure the main switch pressed toward "REMOTE" z Use 20 ~ 24 #AWG wire to connect the remote control terminals Figure 16. Wiring for control 3-2-3. General instruction before DC Input 3-2-3-1 Before installation: The DC cables should be as short as possible (less than 6 feet / 1.8 meters ideally) The size of the cable should be thick enough to limit the voltage drop to less than 2% when carrying the maximum input current to prevent frequent low-input voltage warnings, and shutdown. The following sizes of cables and fuses are recommended distance (<6 ft.) between the batteries and the inverter. 26 Model SP-700-112 / 212 SP-700-124 / 224 SP-700-148 / 248 SP-1000-112 / 212 SP-1000-124 / 224 SP-1000-148 / 248 SP-1500-112 / 212 SP-1500-124 / 224 SP-1500-148 / 248 SP-2000-112 / 212 SP-2000-124 / 224 SP-2000-148 / 248 SP-3000-112 / 212 SP-3000-124 / 224 SP-3000-148 / 248 SP-4000-124 / 224 SP-4000-148 / 248 Wire AWG #6 #10 #16 #4 #8 #14 #1 #6 #10 #1/0 #4 #8 #4/0 #1 #6 #1/0 #4 Inline fuse 150A 80 A 50 A 225A 125A 80A 350A 175A 90A 500A 225A 150A 700A 350A 175A 500A 275A Table 30. SP Series Wiring Cable diameter and Inline Fuse Note! Batteries are capable of providing very large currents in case of short circuit. The fuse should be as close to the positive battery terminal as possible. Use Bussmann ANN series fuses (will also require Fuse Block 4164) or equivalent. 3-2-4. Chassis Ground Must be connected to earth ground prior to making any other connections to the equipment. 3-3. Maintenance Make sure that the fan vents are not blocked. Use a vacuum cleaner to remove any dust from the fan area When cleaning the case or front panel, use a soft, dry cloth, only. If the case or front panel is very dirty, use a neutral, non-abrasive detergent. Do not use alcohol or ammonia based solutions. Regular service, and relocation of the inverter, should be performed by a qualified service technician. Avoid spilling liquid on the inverter. 27 4. Operation 4-1. Connection the DC cable Connect DC input terminals to 12V / 24V /48V battery or other DC power source [ + ] is positive, [ - ] is negative. Reverse polarity connection can blow the internal fuse and may damage the inverter permanently. Figure 17. DC cable connection Warning! Make sure that all the DC connections are tight (torque to 9 10 ft-lbs, 11.7 13 Nm). Loose connections could result in overheating and can be a potential hazard. Warning! The recommended inline fuse should be installed as close to the battery positive terminal as possible failure to use a fuse on the "+" cable running between the inverter and battery may cause damage to the cable / inverter and will void warranty. Also, only use high quality copper wire and keep the cable length short which is a maximum of 3 - 6 feet. 28 Figure 18. Battery cabling 4-2. Connecting the input power Before making the DC input side connections , the main switch must be at "OFF". 4-3. Connecting the loads Calculate the total power consumption of the output load. Make sure that the total power consumption does not exceed the rated power. If the total power consumption over the rated power of the inverter, remove the non-critical: loads until the total power consumption is below the rated power. 4-4. Switch ON Inverter Set the power switch to the "ON" position . The inverter will carry out self-diagnosis and, the LED's will also appear various colors. Set the power switch to the "OFF" position . The inverter stops and all the lights that are on will go off. 29 4-5. Protection Mechanism Model 12V 24V 48V Over Voltage (DC) Under Voltage Shutdown Restart Alarm 16.5V ± 0.3V 14.5V± 0.3V 10.5V ± 0.3V 33V ± 0.5V 29V ± 0.5V 21V± 0.5V 66 ± 1V 58V ± 1V 42V± 1V Under Voltage Shutdown Restart 10.5V ± 0.3V 12.5V± 0.3V 21V ± 0.5V 25V ± 0.5V 42V ± 1V 50 ± 1V Model 12V 24V 48V Table 31. Protection Mechanism Over temperature protection Shutdown Restart 80 60 Table 32. Over Temperature Protection Mechanism 5. RS-232 Communication and Operation 5-1. RS-232 Port RS-232 Port : Serial port monitoring and control through computer Figure 19. RS-232 cable SP Series PIN Number Description 1 Not used 2 GND 3 RXD 4 TXD 5 Remo Control 6 VCC Computer PIN Number Description Not used 1 RXD 2 TXD 3 Not used 4 GND 5 Not used 6 Not used 7 Not used 8 Not used 9 Table 33. RS-232 interface definition 30 5-2. RS-232 Port Operating The following steps show the connection among inverter and computer. Step 1 Connect the RS-232 port to the SP series unit on the front panel Step 2 Run the computer communication program Step 3 Set the transmission protocol Byte structure: START-BIP 8 BIT DATA-STOP BIT Baud rate: 4800 Step 4 Select the COM port and start the operation 5-3. Example of RS-232 Port Operating 5-3-1. RS-232 command format This unit uses high-level language commands starts with CR (0DH) and LF(0AH) as the end of the command, The system would interpret and execute the command only after these two characters are received. After the unit executes the command, it would send a response string to the computer The response string is as follows: => CR LF: Command executed successfully ?> CR LF: Command error, not accepted ! > CR LF: Command correct but execution error (e.g. parameters out of range) 5-3-2. Command format The following table shows the useful command to operate SP series. Function Turn ON / OFF SP series Query the SP series output frequency Query the SP series output voltage Command and description Format : Power <value> <value> can be one of the following. "0" : Power OFF "1" : Power ON Format: FRQ? Format: VINV? 31 Function Query the SP series output current Query the SP series status Command and description Format: IINV? Format: ERR? (SP-700~2000) Bit Description BIT0 0: No OLPL Protection 1: OLPL Protection BIT1 0:No Sof Fail Protection 1:SofFail Protection BIT2 0:No Poff Protection 1:Poff Protection BIT3 0:No UVP Protection 1:UVP Protection BIT4 0:No OVP Protection 1:OVP Protection BIT5 0:No OLPM Protection 1: OLPM Protection BIT6 0:No OLPH Protection 1: OLPH Protection BIT7 0:No OTP Protection 1: OTP Protection BIT8 0:No UTP Protection 1: UTP Protection BIT9 0:No OOCP Protection 1: OOCP Protection * Status definition refer to Table 35. Status definition Format: ERR? (SP-3000~4000) Bit BIT0 Description 0: No ID Fail 1: ID Fail BIT1 BIT2 BIT3 BIT4 BIT5 BIT6 BIT7 0:No Sof Fail Protection 1:SofFail Protection 0:No PLL Fail 1:PLL Fail 0:No Poff Protection 1:Poff Protection 0:No Short Protection 1:Short Protection 0:No OOCP Protection 1: OOCP Protection 0:NoOVP Protection 1:OVP Protection 0:No UVP Protection 1:UVP Protection 32 Function Command and description BIT8 0:No OTP Protection 1: OTP Protection BIT9 0:No UTP Protection 1: UTP Protection BIT10 0:No OLPH Protection 1: OLPH Protection BIT11 0:No OLPL Protection 1: OLPL Protection * Status definition refer to Table 36. Status definition Query the SP series DC input voltage of the battery Query the SP series output power Reset default Format: VBAT? Format: PINV? Format:*RST Select the Setup Menus with the help of Function Codes Format : FUNC <Function Code> Function code Setting Menu 0 OVP setting 1 OVP Recovery 2 UVP Setting 3 UVP Recovery 5 RS-232 Baud-rate 6 Retry Time Query the functions No Query the setting value of the function Set or adjust the value of the function Format: FUNC? Format: SETT? Format: SETT <value> Table 34. RS-232 interface command SP-700 ~ SP-2000 Status Definition Description OLPL Protection Sof Fail Protection Poff Protection UVP Protection OVP Protection OLPM Protection OLPH Protection OTP Protection UTP Protection OOCP Protection Definition OLPL: Over Load Protection Low (101~115%) Sof Fail: Soft Start Fail Poff: Power off UVP: Under Voltage Protection OVP: Over Voltage Protection OLPM: Over Load Protection Middle (116~200%) OLPH: Over Load Protection High (>200%) OTP: Over Temperature Protection UTP: Under Temperature Protection OOCP: Output Over Current Protection Table 35. SP-700 ~ SP-2000 Status Definition 33 SP-3000 ~ SP-4000 Status Definition Description ID Sof Fail Protection PLL Poff Protection OOCP Protection OVP Protection UVP Protection OTP Protection UTP Protection OLPH Protection OLPL Protection Definition ID: ID Connection Error Sof Fail: Soft Start Fail PLL: Phase lock loop Poff: Power off OOCP: Output Over Current Protection (Over Load > 200%) OVP: Over Voltage Protection UVP: Under Voltage Protection OTP: Over Temperature Protection UTP: Under Temperature Protection OLPH: Over Load Protection High (116~200%) OLPL: Over Load Protection Low (101~115%) Table 36. SP-3000 ~ SP-4000 Status Definition The following data shows the function code detail setting value. Note: Below setting value will go back to default value by switching on / off the inverter. 5-3-2-1. FUNC 0 : OVP setting SETT <value> 15.0 ~ 16.5 30.0 ~ 33.0 60.0 ~ 66.0 Default 16.5V <16.5> 33.0V <33.0> 66.0V <66.0> Model SP series-112 / 212 SP series-124 / 224 SP series-148 / 248 Table 37. OVP setting 5-3-2-2. FUNC 1 : OVP Recovery SETT <value> 13.5 ~ 14.5 27.0 ~ 29.0 54.0 ~ 58.0 Default 14.5V <14.5> 29.0V <29.0> 58.0V <58.0> Model SP series-112 / 212 SP series-124 / 224 SP series-148 / 248 Table 38. OVP recovery 5-3-2-3. FUNC 2 : UVP setting SETT <value> 10.5 ~ 11.5 21.0 ~ 23.0 42.0 ~ 46.0 Default 10.5V <10.5> 21.0V <21.0> 42.0V <42.0> Model SP series-112 / 212 SP series-124 / 224 SP series-148 / 248 Table 39. UVP setting 34 5-3-2-4. FUNC 3 : UVP Recovery SETT <value> 12.5 ~ 13.5 25.0 ~ 27.0 50.0 ~ 54.0 Default 12.5V <12.5> 25.0V <25.0> 50.0V <50.0> Table 40. UVP recovery 5-3-2-5. FUNC 5 : RS-232 Baud rate SETT <value> 0 1 2 3 Default 2 Table 41. RS-232 baud rate 5-3-2-6. FUNC 6 : Retry time SETT <value> 0 1 2 3 Table 42. retry time Model SP series-112 / 212 SP series-124 / 224 SP series-148 / 248 Model 1200 2400 4800 9600 Default 3 35 6. Information 6-1. Warning Warning! Do not open or disassemble the Inverter. Attempting to do so may cause risk of electrical shock or fire. 6-2. Warranty We guarantee this product against defects in materials and workmanship for a period of 24 months from the date of purchase. In case you need to repair or replace any defective power inverters, please contact COTEK local distributor. This warranty will be considered void if the unit has been misused, altered, or accidentally damaged. COTEK is not liable for anything that occurs as a result of the user's fault. 36 No.33, Sec. 2, Renhe Rd., Daxi Dist., Taoyuan City 33548, Taiwan Phone +886-3-3891999 FAX +886-3-3802333 http // www.cotek.com.tw 2016.05._A0Acrobat Distiller 8.1.0 (Windows)