NIBE RMU S40 Room Unit Installer Manual

This document provides essential information for installers regarding the NIBE RMU S40 room unit. It details the installation process, electrical connections, commissioning, and operational features to ensure proper integration with NIBE heating systems.

About the RMU S40

The NIBE RMU S40 is a room unit designed to control and monitor NIBE heat pumps, indoor modules, or control modules from a different room within a property. It offers advanced climate control capabilities, allowing users to manage temperature and other settings remotely.

Key Features and Installation

  • Installation: The RMU S40 can be mounted directly on a wall or using the provided backplate, which allows for installation in a standard appliance box. Proper placement is crucial for accurate temperature sensing.
  • Electrical Connection: All electrical connections must be performed by a qualified electrician, adhering to national regulations. The main product must be de-energized during installation. The unit can be powered via a USB power adapter (5V) connected to the Micro-USB port.
  • Connectivity: The RMU S40 supports both wired and wireless connections to the main NIBE product. For wired connections, specific terminal blocks are used, and for wireless connections, a guided setup process is followed via the main product's menu.
  • Functionality: The room unit can display current room temperature, allow temperature adjustments, refine/stabilize room temperature, and display/control humidity levels.

System Integration

The RMU S40 is compatible with NIBE S series main products. It plays a role in managing climate systems and zones, allowing for individual temperature control in different areas of a building. In cases of weak communication, a repeater (RPP 10) may be necessary.

Operation and Navigation

The RMU S40 features a touchscreen interface for intuitive navigation. Users can select options by tapping the screen, scroll through menus by swiping, and adjust settings using a virtual dial. The status light indicates the operational status, with a red light signifying an alarm.

Important Information

This manual is intended for professional installers and should be left with the customer. NIBE reserves the right to make design changes. For detailed information on EU declarations of conformity, visit nibe.eu. Open-source software information is available at opensource.nibe.eu.

Models: RMU S40 Room Thermostat, RMU S40, Room Thermostat, Thermostat

File Info : application/pdf, 84 Pages, 1.71MB

PDF preview unavailable. Download the PDF instead.

631705-1

References

XEP 4.25.502

Related Documents

Preview NIBE SMO S40 Control Module: Installer Manual
Comprehensive installer manual for the NIBE SMO S40 control module, detailing installation, configuration, operation, and troubleshooting for NIBE heating and hot water systems.
Preview NIBE SMO S40 Installer Manual - Control Module Installation Guide
Comprehensive installer manual for the NIBE SMO S40 control module, covering installation, operation, system solutions, and technical specifications. Includes quick guides for navigation and smart features.
Preview NIBE VVM 500 Indoor Module: Efficient Climate Control System
Discover the NIBE VVM 500, a smart and user-friendly indoor module for highly efficient, flexible climate control. Learn about its features, installation, compatible heat pumps, and smart home integration.
Preview NIBE EME 20 Installer Manual: Communication Module
This installer manual provides comprehensive instructions for the NIBE EME 20 communication module, covering installation, connection, and configuration for optimal integration with NIBE heat pumps and solar inverters.
Preview NIBE S1156 Ground Source Heat Pump Installer Manual
Comprehensive installer manual for the NIBE S1156 ground source heat pump, covering installation, operation, and technical specifications. Includes quick start guide, safety information, and detailed component descriptions.
Preview NIBE VST 20 Installation Instructions and Technical Data
Detailed installation guide for the NIBE VST 20, a hot water control accessory for NIBE heat pumps. Covers description, components, hot water production, pool heating, technical data, assembly, and electrical connections for F1345, FIGHTER 1330, F1330, and SMO 10 systems.
Preview NIBE F2050 Air/Water Heat Pump Installation Manual
Comprehensive installation guide for the NIBE F2050 air/water heat pump, covering important information, safety, installation steps, electrical connections, hydraulic connections, commissioning, maintenance, troubleshooting, and technical data. Includes details on compatible indoor modules and regulators.
Preview NIBE F2050 Air-to-Water Heat Pump Installation Manual
Comprehensive installation guide for the NIBE F2050 air-to-water heat pump, covering safety information, handling, installation procedures, electrical connections, startup, operation, and troubleshooting.