Installation Guide for VIKING models including: F-1NX, VA-F1NX, F-1NX Swing Gate Operator, F-1NX, Swing Gate Operator, Gate Operator, Operator
Viking F-1 Swing Gate Opener – Gate Master Pros Download Specs
Abridor de portón batiente Viking F-1 | Confiable y compatible con energÃa solar | EliteGates.net
File Info : application/pdf, 48 Pages, 8.44MB
DocumentDocumentINSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FO R TH E VI KI N G F-1 GATE O P ER ATO R UL 325 CLASS I, CLASS II, CLASS III, AND CLASS IV COMPLIANT Residential and Commercial Vehicular Swing Gate Operator STANDARD FEATURES AND OPERATOR SPECIFICATIONS · Mechanical gate release handle · Plated and powder coated steel chassis · Adjustable travel speed · Opening up to 120° · 100% duty cycle · 400 cycles of operation on backup battery (1500 lb. gate) · Intelligent speed control with smooth start and stop, self-adjust system · Modular Power Supply Box for convenient low voltage installations · Hold Open Timer to automatically close the gate · Intelligent obstruction detection with adjustable sensitivity · Modular connectors for easy access control and accessory installation · Regulated power supply for your external accessories · LED indicators display gate and operator status for easy troubleshooting · On-Board LCD Display provides diagnostics, operator status, settings and real-time volt and amp readings · Built-in motor heater for cold weather applications · Equipped for 115/230 VAC, 24 VAC/VDC and Solar power supplies THE VIKING F-1TM SWING GATE OPERATOR TABLE OF CONTENTS: IMPORTANT SAFETY INFORMATION 2-9 Important Safety Instructions 2 Important Installation Instructions 2-3 Maintenance 4 General Safety Precautions 4-5 UL 325 Gate Operator Classifications 5 Monitored Entrapment Protection Requirements 6 Monitored Entrapment Protection Installation 7 Manual Release 7 Audible Alarm Reset Installation 8 Warning Placard Installation 9 SPECIFICATIONS 10 CONTROL BOARD REFERENCES 11 GATE OPERATOR INSTALLATION Concrete Pad Option Post Mounting Option Operator Positioning 12-15 12 13 14-15 ELECTRICAL INSTALLATION High Voltage Supply Option Low Voltage Supply Option Solar Supply Option Monitored UL Sensor Connections 16-18 16 17 17 18 LIMITS SETUP 19 PRIMARY/SECONDARY SET UP Two Wire Communication Wireless Communication Options 20-21 20 21 CONTROL BOARD SETUP 22-25 Initial Settings 22-23 Obstruction Detection Sensor (ODS) 24 Heater, Lock Mode................................................................................................................. 25 ACCESSORY CONNECTIONS Access Control Connections Radio Receiver Photocell Viking Loop Rack Guidelines for Loop Installations Magnetic Lock, Lock Solenoid Barrier Arm Synchronization Option 26-33 26-27 28 29 30 31 32 33 TROUBLESHOOTING LED References LCD Display References Solutions 34-40 34-35 36-39 40 PARTS DIAGRAM/PARTS LIST 41 LIMITED WARRANTY 42-43 VIKING ACCESSORIES 44 VIKING TECHNICAL SUPPORT 1.800.908.0884 F-1 · Rev I1 · May 2024 11 IMPORTANT SAFETY INFORMATION ! WARNING! Not Following these instructions may cause severe injury or death. IMPORTANT SAFETY INSTRUCTIONS ! WARNING! To reduce the risk of severe injury or death. 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote away from children. 3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or when an object activates the non-contact sensors. After adjusting the force or the limit travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death. 5. Use the manual release only when the gate is not moving. 6. KEEP GATES PROPERLY MAINTAINED. Read the user's manual. Have a qualified service person make repairs to gate hardware. 7. The entrance is for vehicles only. Pedestrians must use a separate entrance. 8. Every gate operator installation MUST have secondary protection devices against entrapment, such as edge sensors and photo beams more in particularly in places where the risk of entrapment is more likely to occur. 9. SAVE THESE INSTRUCTIONS. IMPORTANT INSTALLATION INSTRUCTIONS 1. Install the gate operator only when: a. The operator is appropriate for the construction of the gate and usage Class of the gate (refer to page 5), b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position, c. ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED, AND d. GUARDING IS SUPPLIED FOR EXPOSED ROLLERS. . 2. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. For pedestrian access in the vicinity of an automated vehicular gate, separate pedestrian access shall be provided or available. The pedestrian access shall be in a location such that a pedestrian shall not come in contact with a moving vehicular access gate during the entire path of travel of the vehicular gate. A pedestrian gate shall not be incorporated into an automated vehicular gate panel. 3. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open in to the public access areas. 4. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate. 5. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving AND AWAY FROM THE GATE PATH PERIMETER. 2 VIKING TECHNICAL SUPPORT 1.800.908.0884 IMPORTANT SAFETY INFORMATION ! WARNING! Not Following these instructions may cause severe injury or death. IMPORTANT SAFETY INSTRUCTIONS (Continued) 6. Controls intended for user activation must be located at least six feet (6') away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Exception: Emergency access controls only accessible by authorized personnel (i.e. fire, police, EMS) may be placed at any location in the line-of-sight of the gate. 7. The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start. 8. A minimum of two (2) WARNING SIGNS shall be installed, in the area of the gate. Each placard is to be visible by persons located on the side of the gate on which the placard is installed. 9. For gate operators using non-contact sensors (photoelectric beam or like) in accordance with section 32.1.1 of the UL standard: a. See instructions on the placement of non-contact sensors for each type of application (refer to page 6). b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier (refer to page 6). d. For UL compliance: Use Only - Omron: E3K-R10K4-NR-1 // EMX: IRB-RET, IRB-MON // Miller Edge: RG-K-R, PG-K-R100, PG-K-R50, MIM-62 For ETL compliance: The following can also be used - Viking: FA-XP30-10K // SecoLarm E-931-33PRGQ, E-936-S45RRGQ, E-931-S50RRGQ, E-960-D90GQ // EMX NIR-50325 10. For a gate operator utilizing a contact sensor (edge sensor or like) in accordance with section 32.1.1 of the UL 325 standard: a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as a the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate (refer to page 6). b. One or more contact sensors shall be located at the bottom of a vehicular vertical lift gate. c. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. d. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subject to mechanical damage. e. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstructions. A wireless contact sensor shall function under the intended end-use conditions. f. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 4 inches (101.6 mm) but less than 16 inches (406 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. g. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm). h. For UL compliance: Use only - EMX: WEL-200K // Miller Edge: ME117, ME120, ME123, MG020, MGR20, MGS20, RB-G-K10, MIM-62 For ETL compliance: The following can also be used - ASO: 25.30, 25.45, 95.20 // Miller Edge: ME110 VIKING TECHNICAL SUPPORT 1.800.908.0884 3 IMPORTANT SAFETY INFORMATION ! WARNING! Not Following these instructions may cause severe injury or death. MAINTENANCE Remove the Power Harness from the Control Board. (refer to page 16) · Clean and lubricate the turning pins and gate hinges using the recommended lubricant. · Check that all mounting hardware of the gate operator is properly tighten. · Ensure that the gate moves freely. · Check for corroded parts and replace if necessary. · Check the battery for the following: - Battery connections must be free of corrosion. - Battery voltage must be 26VDC (fully charged battery). Reconnect the Power Harness for the Control Board. (refer to page 16) · Check and confirm the proper operation of all safety devices (photoelectric eye, edge sensors or like). · Check and confirm the operation of all installed accessories. · Check and confirm the operation of all special features such as the Intelligent Obstruction Sensor and Hold Open Timer. (refer to pages 22-24) · Check and confirm the operation of the manual release. (refer to page 7) · Verify the functionally of the battery backup, or power failure option, by turning of f the main power source (115VAC or 230VAC). DO NOT FORGET TO TURN ON THE MAIN POWER SOURCE AFTER VERIFICATION. GENERAL SAFETY PRECAUTIONS The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully as they contain important indications for the safe installation, use and maintenance. · These instruction must be kept and forwarded to all possible future users of the system. · This product must be used only for that which it has been expressly designed. · Any other use is to be considered improper and therefore dangerous. · The manufacturer cannot be held responsible for possible damage caused by improper, erroneous or unreasonable use. · Avoid operating in the proximity of the hinges or moving mechanical parts. · Do not enter the path of the moving gate while in motion. · Do not obstruct the motion of the gate as this may cause a situation of danger. · Do not allow children to play or stay within the path of the moving gate. · Keep remote control or any other control devices out of the reach of children, in order to avoid possible involuntary activation of the gate operator. · In case of break down or malfunctioning of the product, disconnect from the main power source. Do not attempt to repair or intervene directly, contact only qualified personnel for repair. · Failure to comply with the above may create a situation of danger. · All cleaning, maintenance or repair work must be carried out by qualified personnel. · In order to guarantee that the system works efficiently and correctly it is important to have the manufacturer's instructions on maintenance of the gate and operator carried out by qualified personnel. · In particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. 4 VIKING TECHNICAL SUPPORT 1.800.908.0884 IMPORTANT SAFETY INFORMATION ! CAUTION: To Reduce the Risk of Fire or Injury to Persons: GENERAL SAFETY PRECAUTIONS (Continued) a. Use only the following type and size battery(ies): Yuasa NP7-12 or VIKING DUBA12 b. 'RQRWGLVSRVHRIWKHEDWWHU\LHVLQ´UH7KHFHOOVPD\H[SORGH&KHFNZLWKORFDO codes for possible disposal instructions. c. Do not open or mutilate the battery(ies). Released electrolyte is corrosive and may cause damage to the eyes or skin. It may be toxic if swallowed. d. Exercise care in handling batteries in order not to short the battery with conducting materials such as rings, bracelets and keys. e. &KDQJHWKHEDWWHU\LHVSURYLGHGZLWKRULGHQWL´HGIRUXVHZLWKWKLVSURGXFWRQO\LQ DFFRUGDQFHZLWKWKHLQVWUXFWLRQVDQGOLPLWDWLRQVVSHFL´HGLQWKLVPDQXDO f. Observe proper polarity orientation between the battery(ies) and charging circuit. g. Do not mix batteries of different sizes or from different manufactures in this product (applies to products employing more than one user replaceable secondary battery). h. A battery-operated product employing a secondary battery supply intended to be FKDUJHGZLWKLQWKHSURGXFWVKDOOFRQWDLQVSHFL´FLQVWUXFWLRQVFRQFHUQLQJWKHSURSHU method of charging. UL 325 Gate Operator Classifications GLOSSARY RESIDENTIAL VEHICULAR GATE OPERATOR CLASS I - A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families. COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public. INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR CLASS III A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public. RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. Install the gate operator only when: The operator is appropriate for the construction of the gate and the Usage Class of the gate. VIKING TECHNICAL SUPPORT 1.800.908.0884 5 IMPORTANT SAFETY INFORMATION ! WARNING! Not Following these instructions may cause severe injury or death. Monitored Entrapment Protection Requirements IMPORTANT: MONITORED PROTECTION MUST BE INSTALLED · REQUIRED BY UL 325, an approved MONITORED entrapment protection sensor is REQUIRED to be installed in all areas accessible to potential entrapment and pinch points. · For a horizontal swing gate operator, at least one Monitored External Entrapment Sensor is required in each direction of travel. Except, if there is no entrapment zone in one direction of travel, it is not required to have a Monitored Entrapment sensor for that direction of travel. ! If there is a possible entrapment zone in the open direction, an external sensor MUST be connected to the "UL" input or the installation will not comply with UL 325. ! An external sensor connected to the "Re-Open" input terminal will protect against entrapment ONLY in the closing direction. · The installed sensor MUST be "10K Resistor Based". · You may connect up to FOUR monitored sensors, wired in parallel, to either the "UL" and/or "Re-Open" terminals, for a total of 8 monitored sensors. · Failure to install the required monitored entrapment protection sensor(s) may render the gate operator INOPERABLE . The gate can be moved manually. Refer to page 7. · Consult the installation manual of the sensor for detailed information about the usage, installation and maintenance. · Use only UL and/or ETL Recognized Edge Sensors and Photoelectric Sensors. Refer to pg 3. SWING GATE ENTRAPMENT ZONE Locations between a moving gate or moving, exposed operator components and a counter opposing edge or surface where entrapment is possible up to 1.8 m (6 ft) above grade. Such locations occur if during any point in travel: a. The gap between the bottom of a moving gate and the ground is greater than 101.6 mm (4 in) and less than 406 mm (16 in); or b. The distance between the center line of the pivot and the end of the wall, pillar, or column to which it is mounted when in the open or closed position exceeds 101.6 mm (4 in). Any other gap between a moving gate and fixed counter opposing edges or surfaces or other fixed objects is less than 406 mm (16 in) (examples are walls, curbs, berms or other immovable objects). Gate in Closed Position Photoelectric Sensor (non-contact sensor) Potential Entrapment Area Photo Beam Unit 5HµHFWRU Potential Entrapment Area Edge Sensor (contact sensor) 6 Edge Sensors VIKING TECHNICAL SUPPORT 1.800.908.0884 IMPORTANT SAFETY INFORMATION ! WARNING! Not Following these instructions may cause severe injury or death. Monitored Entrapment Protection Installation ! IMPORTANT: A minimum of one Monitored External Entrapment Sensor is required to be connected to the UL terminal OR the Re-Open terminal. If there is a possible entrapment zone in the open direction, an external sensor MUST be wired to the "UL" input or the installation will not comply with UL 325. "UL" Protects against entrapment in both the opening and closing directions. Input will reverse the gate momentarily in the opposite direction it was traveling. Refer to page 18. "Re-Open" Protects against entrapment in the closing direction ONLY. Input will reverse the gate all the way to the Open Limit. Refer to page 18. STEP 1: Connect the monitored entrapment protection sensor(s) to the Viking Control Board. Refer to page 18 for detail 10K Monitored Terminal 10K Monitored Terminal STEP 2: Execute the Learn Process: · Press and release the "Diagnose" button until you see UL LEARN NO LEARN on the LCD Display. · Press and hold the "Stop" button. · Toggle the "Diagnose" button once. · The number of Monitored sensors connected to the "UL" or "Re-Open" terminals will now be displayed. EXAMPLE: UL LEARN UL2 RO1 UL LEARN NO LEARN UL SENSOR ERRORS: If a problem occurs with one of the monitored entrapment sensors, the "Stop" LED will illuminate and an ERR message will be displayed, indicating which input terminal(s) the sensor is connected to. TERMINAL: "UL" "Re-Open" "UL" & "Re-Open" ERROR MESSAGE: ERR SENS UL ERR SENS RO ERR SENS UL RO Manual Release When manual operation is required: 1. Remove the "Output Shaft Cover" or Hat. 2. Lift the "Manual Release Handle". 3. Remove the "Clutch Key". To resume normal operation: 1. Align the notches on the Output Shaft to the clutch and reinstall the Clutch Key. 2. Push the Manual Release Handle down, back to the locked position. Refer to page 15 for more details. VIKING TECHNICAL SUPPORT 1.800.908.0884 Output Shaft Cover Locking Handle (in Unlocked Position) Clutch Key 7 IMPORTANT SAFETY INFORMATION ! WARNING! Not Following these instructions may cause severe injury or death. Audible Alarm Reset Switch Installation Manual Reset for the Audible Alarm · UL 325 standard requires an audible alarm to sound after two consecutive events detected by the inherent entrapment protection of the gate operator (obstruction sensor). · The audible alarm will continue to sound for 5 minutes or until a stop command is actuated. · The Stop command can be actuated in two different forms: 1. Using the Built in Stop switch on the Control Board or; 2. Using an External Stop button within the sight of the gate, away from moving parts of the gate and out of reach of children. a. Controls intended for user activation must be located at least six feet (6') away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. b. The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start. COM 2 N.O. STOP External Stop Button STOP 5' Minimum 8 VIKING TECHNICAL SUPPORT 1.800.908.0884 IMPORTANT SAFETY INFORMATION ! WARNING! Not Following these instructions may cause severe injury or death. DO NOT allow pedestrian use of this gate DO NOT install the gate operator to lift gates Locate Control Buttons · Within sight of the gate, · At a minimum height of 5 feet so small children are not able to reach it; and · At least 6 feet away from all moving parts of the gate. Warning Placard Installation · All Warning Placards must be installed where visible in the area of the gate. · A minimum of two placards shall be installed. · A placard is to be installed in the area of each side of the gate and be visible. VIKING TECHNICAL SUPPORT 1.800.908.0884 OPEN STOP CLOSE 9 SPECIFICATIONS Max Gate Length Max Gate Weight 8/&ODVVL´FDWLRQ Duty Cycle Operating Voltage Main Power Source Main Power Current SPECIFICATIONS 12 Feet / 16 Feet Main Power Frequency 1500 lbs / 1000 lbs Main Power Fuse Class I, II, III, IV *refer to page 5 Alternative Power 100% Accessory Power 24VDC Power Consumption 120VAC / 240VAC Single Phase Motor Current Draw - Typical 2.5A / 1.5A Operating Temperature 50Hz / 60Hz 4.0A Timed 24VAC/VDC (60VA) or Solar 24VDC (750mA) 70mA 4.0A -20°F (-28°C) to 160°F (71°C) 26 17¾ 24½ 20½ 7 EQ EQ 1. COVER BOLTS 2. OUTPUT SHAFT COVER (HAT) 3. MAIN COVER ASSEMBLY 4. MANUAL RELEASE HANDLE releases the clutch to allow for manual operation 5. CLUTCH KEY install if application does not require clutch to slip; remove to manually operate the gate 6. OUTPUT ARM connects the Arm Assembly to Clutch & Handle Assembly 7. VFLEX CONTROL BOARD 8. MOTOR SWITCH discontinues power to the motor; also serves as a breaker that will self-trip to protect the motor circuitry 9. BATTERY SWITCH disconnects batteries from the charging circuit during troubleshooting 10. MAIN AC POWER SWITCH discontinues the 115/230VAC power supplied to the operator 11. EMI FUSE main power supply protection 12. MODULAR POWER BOX ASSEMBLY removable; provides a convenient solution for optional low voltage installations 13. LOOP RACK for convenient loop detector installation 14. J-BOX high voltage power supply connection 15. COVER BOLT MOUNTING BRACKET 10 VIKING TECHNICAL SUPPORT 1.800.908.0884 CONTROL BOARD REFERENCES 1. POWER HARNESS CONNECTOR provides power to the control board. pg 16-17 2. "OPEN LEFT" & "OPEN RIGHT" provides power to the motor. pg 19 3. LIMIT SETUP BUTTONS available for future developments. 4. FEATURE ACTIVATION TRIM POTS activate and set features. pg 22 5. "EPS1" CONNECTOR available for future developments. 6. "EPS2" CONNECTOR available for future developments. 7. EMI BOARD CONNECTOR monitors the high voltage power supply. 8. "CHECK MOTOR" Status LED indicates motor power status. pg 34 9. "BATTERY LOW" Status LED indicates battery power status. pg 34 10. "POWER" Status LED control board power status. pg 16,34 11. "MAGNETIC LOCK RELAY" Status LED status of this on-board relay. pg 32, 34 12. "MAGNETIC LOCK RELAY" Terminal Block connect electric locks here. pg 32, 34 13. INPUT STATUS LEDs indicates input status. pg 34-35 14. ACCESS CONTROL TERMINAL BLOCKS accessory connections. pg 26-33 15. "PRIMARY/SECONDARY" Terminal Block wired Primary/Secondary. pg 20 16. CONTROL BOARD MOUNTING HOLES secures and grounds the control board. 17. "Siren" Terminal Block Vikings UL Siren is connected here. 18. ON-BOARD 3 BUTTON STATION controls the gate during set up. 19. "AUX. PWR" Terminal Block used for solar applications & in-motion warning devices. pg 17, 23 20. FEATURE ACTIVATION PIN HEADERS activate features by placing a jumper onto the pin headers. pg 23 21. "DIAGNOSE" Button allows you to navigate through the Diagnostics LCD Display. pg 36-39 22. "DIAGNOSE" LED informs that errors have been detected and available on LCD Display. pg 38 23. LCD DIAGNOSTICS DISPLAY provides error messages, diagnostics and operator status information. pg 36-39 24. EXPANSION PRODUCT CONNECTIONS connections for additional products from Viking Access Systems. pg 21, 44 25. "FAIL SAFE/SECURE" Jumper power failure option. pg 23 26. FUSE HOLDER - 15 AMP for motor circuit. 27. FUSE HOLDER - 4 AMP for charging circuit. 28. HEAT SINK secures the control board and dissipates heat. VIKING TECHNICAL SUPPORT 1.800.908.0884 11 GATE OPERATOR INSTALLATION Concrete Pad Option 1. Follow the local building code to determine the required depth of the concrete pad. 2. Pad measurements recommended by Viking Access Systems are at least 24" long, 22" wide and 30" deep to ensure the stable operation of the operator, and a minimum of 6" above level grade to avoid any flooding of the machinery. 3. Provide a sufficient number of conduit pathways for all low power accessories such as loop detector leads, maglock, non-contact sensors, contact sensors, safety and other commands. Also provide conduit for the power supply to the operator. ! DO NOT run low voltage and high voltage wiring in the same conduit. ! Provide at least 12" separation between low and high voltage conduits. 11" 9" Center of Output Shaft Drill for a ½" x 3½" Red Head Anchor (4) Places 24" 22" 6" Minimum 11¼" 2¼" Conduit Location 10" 12½" 2¼" 30" Grade Level See Note 2 Gate Operator Concrete Pad 12 VIKING TECHNICAL SUPPORT 1.800.908.0884 GATE OPERATOR INSTALLATION Post Mounting Option TIP: The operator can be post mounted to be elevated above snow and flood lines. 1. Consult the local building codes for the depth and concrete requirements. 2. Maximum 3.00" OD pipe. 3. Provide a sufficient number of conduit pathways for all low power accessories. Also provide conduit for the power supply to the operator. ! DO NOT run low voltage and high voltage wiring in the same conduit. ! Provide at least 12" separation between low and high voltage conduits. REQUIRED ADD-ON: PART# VA-F1PS · Main pieces made of 1/4" thick material · All mounting hardware is included · Posts and U-Bolts are not supplied 3.05" I.D. 13½" 8.05" 3½" 10½" (inside) 2¾" Mounting Bolt Washer Gate Operator Chassis Pipe Stand Washer Nut 2¾" 3.00" O.D. Pipe (Maximum) Secure Stand to Pipes Using (6) Supplied Bolts Grade Level VIKING TECHNICAL SUPPORT 1.800.908.0884 13 GATE OPERATOR INSTALLATION Operator Positioning ! IMPORTANT: Swing Gates must not open into public access areas. The gate must be installed in a location so that enough clearance is supplied between the gate, while opening and closing, and adjacent structures to reduce the risk of entrapment. C C = A + 12" B B = 12" to 18" Gate Closed E = L x E 0.6 wL i=th8V7"ikMinLagxAimrmum D = L x D 0.4 A = C - 12" F F = E + 4" Gate in Open Position ! TECHNICAL TIPS: Operator and Arm Geometry · Increasing "C" dimension provides better gate control and stability by reducing the effects of inertia and deceasing the gate leverage against the operator. · Following to the geometrical formulas and relationships provided is recommended. Arm Assembly: VA-F1ARM20 Gate must travel level. Pivot Bracket 14 Dimension D Dimension E Primary Extension Secondary Extension VIKING TECHNICAL SUPPORT 1.800.908.0884 GATE OPERATOR INSTALLATION ! IMPORTANT: When attaching the Arm Assembly to the gate, if the "Gate Bracket" is not welded to a frame member that runs the full length of the gate, the operator may damage the gate. Do not attach the Gate Bracket to only a few pickets. STEP 1 Install the Clutch and cut the Arm Assembly to achieve the desired dimensions for "D" and "E" according to the formulas provided. STEP 2 With the gate at the closed, install the Arm Assembly. Check that the dimensions correspond accordingly to the formulas provided. Remove Excess Extension Tube ! TIP: Leave some additional material when cutting the Arm Assembly to allow for adjustment. ! TIP: Use C-clamps or tack-weld the Arm assembly in place until Step 3 has been completed. STEP 3 With the Clutch installed and released, manually move the gate to both limits. Verify the following: 1. The gate reaches the desired limits. 2. The Arm does not bind at any point. STEP 4 Once satisfied with the installation and movement of the gate, weld the arm pieces securely. Paint the Arm to protect against rusting. STEP 5 Rotate the Clutch until it lines up with the notches on top of the Output Shaft and insert the Clutch Key. STEP 6 Verify the Clutch is adjusted properly. · Both sides adjusted evenly. · Handle is locked, by hand, and positioned horizontally at 0°. With the Clutch Key removed, the Clutch should not slip with moderate force applied to the gate. VIKING TECHNICAL SUPPORT 1.800.908.0884 Tighten the Clutch 15 ELECTRICAL INSTALLATION High Voltage Supply Option ! Caution: Always turn off power breakers when working with high voltage. DO NOT connect the "Power Harness" to the Control Board until the electrical installation is complete and ready for verification. STEP 1 At the "Power Box": a. Set the "Voltage Selector" according to the supply voltage (115V or 230V). b. Turn the "AC Power" switch ON 1a 1b STEP 2 ! WARNING: SINGLE PHASE AC ONLY At the "J-Box": a. Connect the incoming power wires, matching the wire color codes. 2a b. If the supply voltage is 120VAC, connect the red wire, labeled "Outlet Power", to the neutral (white) wires. STEP 3 a. Turn ON the main facility breaker b. Verify that all three (3) LEDs are illuminated at the "Power Box". c. Turn the "Battery Switch" ON. At the Control Board: 3c d. Connect the Power Harness and verify the "POWER" LED is illuminated solid. 3d ! TECHNICAL TIP: If the "Power" LED is flashing or any of the 3 LEDs on the "Power Box" are not illuminated, refer to the Troubleshooting pages. 3b Tips for proper ground installation: To minimize the effects caused by lightning, follow these guidelines. · Use a ground rod to provide a ground reference. · Consult your city code and be aware of under-ground services in the site of the gate operator to prevent inconveniences. · Always use a single bonding point for grounding. · All ground wires must be as short and as thick as possible. · Prevent unnecessary turns or loops in all ground wires. 16 Earth Ground Ground Rod VIKING TECHNICAL SUPPORT 1.800.908.0884 ELECTRICAL INSTALLATION Low Voltage Supply Option TIP: The operator is equipped with a Modular Power Box that can be relocated to provide power for low voltage installations. Supplies 24VAC to the operator. ! Caution: Always turn off power breakers when working with high voltage. DO NOT connect the "Power Harness" to the Control Board until the electrical installation is complete and ready for verification. Remove the "Power Box" from the operators chassis and relocate to the nearest high voltage source (115V or 230V single phase AC). Follow local codes or guidelines. MAXIMUM DISTANCE: 500 ft. with 10 AWG wire 115/230V AC 24V AC Connect to the Power Harness Green & White wires Solar Supply Option Vikings Solar Package (part # VA-SOCHP) is an efficient and effective solution to powering the operator with solar energy. (See page 44 for package details) ! Tip: Solar efficiency can be increased by activating the "Pre-Warning" A feature. The "Aux. Pwr" B terminals will provide 24VDC to all nonessential controls, beginning 3 seconds prior to gate movement, until the gate reaches either limit. (page 23) For 12V solar panels connect two in series for 24V Solar Input Battery Input Load Input + + + 12V x 2 AB 24V x 1 Connect the batteries in series for 24V + + Disconnect the operators power harness and use the Solar Harness. ! IMPORTANT: The number of cycles achieved daily is dependent on many factors, including local solar radiation data and power consumption of the motor and accessories. It is very important that you consider this when using solar power. VIKING TECHNICAL SUPPORT 1.800.908.0884 17 ELECTRICAL INSTALLATION MONITORED UL SENSOR CONNECTIONS UL (Monitored Input Terminal) The "UL" input terminal protects against entrapment in both the opening and closing directions. Input will reverse the gate momentarily in the opposite direction it was traveling when a connected device it triggered. Pages 6-7. Re - Open (Monitored Input Terminal) The "Re-Open" input terminal protects against entrapment in the closing direction ONLY. Input will reverse the gate all the way to the Open Limit when a connected device it triggered. Pages 6-7. Power Terminals Relay Terminals 10K Monitored Power Terminals Relay Terminals 10K Monitored NOTE: The "Stop" LED will be illuminated if there is a failure with at least one monitored entrapment sensor and the gate operator will be rendered inoperable. Check for proper operation: When a connected device is triggered, the "UL" LED will illuminate and, if more than one Monitored device connected, the "Stop" LED will flash rapidly to indicate an input. ! If more than one Monitored device is connected to this terminal, the "UL" LED will be illuminated. This alone is inconsequential. Check for proper operation: When a connected device is triggered, the "Re-Open" LED will illuminate and, if more than one Monitored device connected, the "Stop" LED will flash rapidly to indicate an input. ! If more than one Monitored device is connected to this terminal, the "Re-Open" LED will be illuminated. This alone is inconsequential. ! TECHNICAL TIP: For more information regarding accessory connections to the Control Board and individual input terminal functions, refer to pages 26-27. 18 VIKING TECHNICAL SUPPORT 1.800.908.0884 LIMITS SETUP ! IMPORTANT: This gate operator uses mechanical limit switches. Therefore, the limits cannot be set electronically by the Control Board. The Limit Buttons on the Control Board have been rendered inactive. STEP 1 Connect the "Limit Switch Harness" to the Control Board. a. "OPEN RIGHT" Connector if the gate opens Right. b. "OPEN LEFT" Connector if the gate opens Left. 1 OPEN LEFT OPEN RIGHT 1a Limit LEDs indicate that the gate is at the corresponding limit position. 1b Gate OPENS to the LEFT Left Limit Switch = Close Limit Right Limit Switch = Open Limit Gate OPENS to the Right Left Limit Switch = Open Limit Right Limit Switch = Close Limit STEP 2 At the "Limit Cam & Holder" assembly: a. Loosen screws on both of the "Limit Cams". b. With the Articulating Arm and "Clutch" installed, insure that the "Clutch Guide Pin" is inserted into one of the four holes on the "Cam Holder". c. Move the gate manually to the desired closed limit position and adjust the nearest "Limit Cam" to actuate the corresponding "Limit Switch". d. Slightly tighten the Limit Cam Screws. e. Repeat Step 2c & 2d for the desired open limit position. f. Run the gate 2 full cycles before confirming your limit settings. Adjust accordingly if required. Clutch Clutch Guide Pin Left Limit Switch Black Red White Green Right Limit Switch Set Left Limit Cam in this direction Cam Holder Set Right Limit Cam in this direction NOTE: Referring to Step 2b. The "Cam Holder" contains four (4) Guide Pin holes for convenience. It is recommended to mark the hole used for future reference if needed. ! TECHNICAL TIP: Each Limit LED will illuminate solid when the corresponding limit switch is actuated. Several LEDs will flash simultaneously when both Limit Switches are actuated at the same time or may indicate a problem with the limit switches or wires. VIKING TECHNICAL SUPPORT 1.800.908.0884 19 PRIMARY/SECONDARY SETUP Two Wire Communication ! IMPORTANT: DO NOT run the Primary/Secondary communication cable in the same conduit or within 12" of 115 - 230V power supply cables. ! Technical Tip: DO NOT set the "Timer" and/or "Overlap" features on both operators Control Boards. Only turn these features on at the Primary Control Board. CABLE REQUIREMENTS: · 2 Conductor (wire) · 18 AWG or better · Shielded (overall foil) · Drain Wire (bare wire) MS1 MS1 MS2 MS2 Connect Drain Wire to Chassis Ground Connect Drain Wire to Chassis Ground Step 1 Connect shielded cable to "Primary/Secondary" connectors at the control boards Step 2 At the Primary Operator: Connect the entrapment protection sensor(s) as described on pages 7 and 18. Step 3 At the Secondary Operator: Turn ON the DUAL MODE Feature: · Toggle the "Diagnose" button until you see DUAL MODE on the LCD Display. · Default setting is OFF. · Press and hold the "Stop" button. · Toggle the "Diagnose" button once. · The feature should now be displayed as ON. 20 DUAL MODE ON VIKING TECHNICAL SUPPORT 1.800.908.0884 PRIMARY/SECONDARY SETUP Wireless Communication Options REQUIRED ADD-ON: Viking Konnect - Wireless Primary/Secondary Kit PART# VA-KONNECT-MS ! Technical Tip: DO NOT set the "Timer" and/or "Overlap" features on both operators Control Boards. Only turn these features on at the Primary Control Board. Green LEDs will be illuminated solid when communication is ON. Step 1 Plug the modules on to the "V.K" plug & play connection of each operators Control Board. It is not important which board the Primary or Secondary module is placed on. Step 2 At the Primary Operator: Connect the entrapment protection sensor(s) as described on pages 7 and 18. Step 3 At the Secondary Operator: Turn ON the DUAL MODE Feature: · Toggle the "Diagnose" button until you see DUAL MODE on the LCD Display. · Default setting is OFF. · Press and hold the "Stop" button. · Toggle the "Diagnose" button once. · The feature should now be displayed as ON. VIKING TECHNICAL SUPPORT 1.800.908.0884 DUAL MODE ON 21 CONTROL BOARD SETUP Initial Settings "Speed" Motor Speed Increases or decreases the speed of gate travel. "ODS" Obstruction Detection Sensor Sets the amount of force required to trip the inherent obstruction sensor. See page 24 for more details about this feature. "Overlap" Overlap Delay Delays the gate from opening for the selected amount of time from 1-6 seconds. ! For Primary/Secondary or dual applications, the Primary will delay to open and the Secondary will delay to close. "Timer" Hold Open Timer Automatically closes the gate after the selected amount of time from 1-60 seconds. Turning the dial between "0" and "OFF" will disable this feature, requiring a close command to close the gate. 22 VIKING TECHNICAL SUPPORT 1.800.908.0884 CONTROL BOARD SETUP Initial Settings NOTE: Installing a shunt, or jumper, on the pins will activate the feature. "Auto Open" - Power Failure Option Opens the gate automatically during power failure. Resumes normal operation when power is restored. "Fail Safe/Secure" During power failure, determines the force required to manually move the gate. · Fail Safe Mode: By removing the wire-jumper plug from the "Fail Safe/Secure" connector: The gate can move manually with a relatively low amount of force. · Fail Secure Mode: By inserting the wire-jumper plug into the "Fail Safe/Secure" connector: The gate will require more effort to manual move. "Last Open" - Power Failure Option Opens the gate automatically when the battery backup voltage is critically low. "Pre-Warning" Initiates two options for an audible or visual warning 3 seconds prior to gate motion and will continue: 1. Until gate reaches closed limit: "Magnetic Lock" terminals provide a contact between "COM" and "N.O.". 2. Until gate reaches either limit: "AUX. PWR" terminals provide 24VDC. "Sync" Used only in conjunction with Barrier Arm Operators. Activating this feature allows for synchronized operation with Barrier Arm Operators. See page 33. VIKING TECHNICAL SUPPORT 1.800.908.0884 "EXT" Available for future developments. 23 CONTROL BOARD SETUP Obstruction Detection Sensor (ODS) ! IMPORTANT: The appropriate "ODS" setting is dependant upon the gate installation and construction. Set this feature accordingly. Additional Safety equipment should be used to reduce possible risk of injury or vehicle damage. "ODS" Obstruction Detection Sensor The Obstruction Sensor detects obstructions in the path of the traveling gate. The dial sets the amount of force required to activate the operators inherent obstruction detection. Setting the dial to "0" will require the least amount of force to activate; Setting the dial to "100" will require the maximum amount of force to activate. UL 325 standard requires an audible alarm to go off after two consecutive entrapment events sensed by the Inherent Entrapment Protection of the Gate Operator. The audible alarm will sound for a period of 5 minutes or until a Stop command or the "Alarm Reset" switch has been actuated. (refer to page 8) When the Obstruction Sensor detects an obstruction it will: 1. Stop the gate's movement and reverse it momentarily. 2. Bring the gate to a resting position. 3. Disable the Hold Open Timer feature until the Gate Operator receives a new command. If second obstruction is detected before the gate reaches either limit it will: 1. Stop the gate's movement. 2. Disable the Gate Operator. 3. Sound the UL Alarm 4. A STOP command must be provided to disable the alarm and continue operation. ! TECHNICAL TIP: The Status LED for the "ODS" will indicate the following when it has been triggered. A. Solid: Obstruction. Detected a sudden or abrupt increase in gate resistance. B. Flashing: Overload. Detected a more subtle, but sustained increase in gate resistance. 24 VIKING TECHNICAL SUPPORT 1.800.908.0884 CONTROL BOARD SETUP Viking Heater The operator has an integrated heater that is thermostatically controlled. Activate this feature when the operator is used in application temperatures down to -20°F (-29°C). To set the heater to turn on at the Close Limit: 1. Use the "Diagnose" button to scroll through the LCD Display to "HEATER CLS" 2. Press and hold the "Stop" button on the Control Board. 3. Press and release the "Diagnose" button to turn this feature ON and OFF. To set the heater to turn on at the Open Limit: 1. Use the "Diagnose" button to scroll through the LCD Display to "HEATER OPN" 2. Perform steps 2-3 as described above. HEATER CLS ON HEATER OPN ON NOTE: If the application requires the gate to be held open for any reason, set the HEATER ON for both limit positions. ! IMPORTANT: AN EXTERNAL POSITIVE STOP must be used on the gate at the limit position(s) the HEATER has been set for. LOCK MOD ON Viking Lock Mode Turning this feature ON will secure the gate at the closed position, preventing unauthorized manual entry. Use the LCD Display to activate this feature. 1. Use the "Diagnose" button to scroll through the LCD menu to "LOCK MOD" 2. Press and hold the "Stop" button on the Control Board. 3. Press and release the "Diagnose" button to turn this feature ON and OFF. VIKING TECHNICAL SUPPORT 1.800.908.0884 25 ACCESSORY CONNECTIONS Access Control Connections Power Connections The Control Board provides a 24VDC output to power external devices and controls. Alternatively, for devices that require a power supply other than 24VDC, the operators Power Box contains a convenient 120VAC receptacle to connect a plug-in transformer. Terminals Connections and Input Functions: "C" = "N.O." = Common Normally Open Viking Terminal "+28V" --------------------- "GND" --------------------- "GND" --------------------- "Radio" If "Timer" OFF: If "Timer" ON: " U L" (see pages 6-7 & 18) If stopped: If traveling: "Re- Open" (see pages 6-7 & 18) If stopped: If closing: "ATG" Anti-Tailgate Input is received: Input is released: "C. Loop" If not at open limit: If at open limit: "Open", "Exit", "Fire" & "Strike" If stopped: If closing: "Stop" If traveling: "Close" If stopped: If traveling: Function Device Terminal DC Positive DC Negative Relay Common ------------------------------------------- "+" "" "C" "N.O." Open - Stop - Close Open / Reopen if closing "N.O." Prevents the gate from moving Stops then reverses gate momentarily "N.O." No function Stops then Opens gate "N.O." Stops gate if closing Closes gate to prevent tailgating "N.O." No function Prevents gate from Closing "N.O." Opens gate Stops then Opens gate "N.O." Stops gate "N.O." Closes gate No function ! TECHNICAL TIP: Each input Terminal (i.e. Radio, Exit, Re-Open, UL) has a corresponding Status LED that when illuminated indicates an input is currently being provided to the terminal and the gate is responding accordingly. (See pages 34-35 LED References) 26 VIKING TECHNICAL SUPPORT 1.800.908.0884 ACCESSORY CONNECTIONS Relays In General NOTE: Viking Access Systems does not provide the external safety devices and access controls. These items can be purchases from your dealer or distributor. In General In regards to the Viking Control Board, all external safety devices and access controls contain, and are, simple relays that provide an input to the Viking Control Board when the device is activated. When these devices are activated, their internal relays create a contact, or short, between the "C" and "N.O." terminals. This contact is what provides the command to the Viking Control Board. ! TECHNICAL TIP: Viking uses the Normally Open "N.O." contact from the device, excluding "fail-safe" type photo beams. In such instances, the Normally Closed "N.C." will be used instead. +28V GND + COM -- N.O. N.C. GND EXIT Not Used Glossary of Terms 1. Terminal: Wire Connections. 2. Input Terminal: On the Viking Control Board, the terminal which is labeled for a specific command (Re-Open, Exit, Radio, etc.). The N.O. contact from the access control device is to be connected to the Input Te r m i n a l . 3. Terminal Block: On the Viking Control Board, a removable block containing multiple terminals. 4. Relay: The component of an access control or safety device that provides an input or command to the Viking Control Board. 5. "C" Relay Common Terminal: This is the relay terminal that makes contact (a short) to the N.O. terminal when the device is activated. Always wire this relay terminal to any "GND" terminal at the Control Board. 6. "N.O." Relay Normally Open Terminal: The relay terminal that has an open contact to "C" while the relay is not activated, and a closed contact when the relay is activated. Almost always wire this relay terminal to an "Input Terminal" at the Control Board, 7. "N.C." Relay Normally Closed Terminal: The relay terminal that has a closed contact to "C" while the relay is not activated, and an open contact when the relay is activated. This terminal is rarely used. 8. Relay Coil: Contains the terminals that provide power at the relay. 9. "+" Relay Positive Terminal: The positive power pole for the relay coil. Always wire this relay terminal to any "+28V " terminal at the Control Board. 10. " " Relay Negative Terminal: The negative power pole for the relay coil. Always wire this relay terminal to any "GND" terminal at the Control Board. VIKING TECHNICAL SUPPORT 1.800.908.0884 27 ACCESSORY CONNECTIONS Radio Receiver NOTE: The operator may be supplied with a FA-XR2C Radio Receiver and (2) FA-XT4RC Transmitters. STEP 1 Wire the Radio Receiver as illustrated. ! TECHNICAL TIP: The FA-XR2C Radio Receiver is IP44 rated for water resistance and can be mounted outside of the operator cover if desired. STEP 2 Program the FA-XT4RC Radio Transmitters to the FA-XR2C Radio Receiver. Follow the instructions provided with the Transmitters. FAAC XR2 Wiring Terminals Harness + RED - BLACK COM GREEN "Radio Station" +28V GND GND N.O. WHITE Radio ! TECHNICAL TIP: The Control Board provides two modes of operation that a radio receiver can control the gate. For more information regarding accessory connections and terminal functions, refer to pages 26-27. 1. Open-Stop-Close By having the radio receiver connected as illustrated and with the "Timer" OFF: This type of configuration is not recommended for commercial installations. 2. Open Only By having the radio receiver connected as illustrated and with the "Timer" ON. 28 VIKING TECHNICAL SUPPORT 1.800.908.0884 TX DL2 ACCESSORY CONNECTIONS Photocell NOTE: The operator may be equipped with a FA-XP30-10K Photocell. Refer to pages 6-7, 18 for UL 325 requirements. UL or Re-Open COM and -+ + + SW1 DL1 DL4 NC RX NO NC COM - + SW1 DL1 VIKING TECHNICAL SUPPORT 1.800.908.0884 29 ACCESSORY CONNECTIONS Viking Loop Rack TIP: This operator may be equipped with a pre-wired Loop Rack that plug-in type loop detectors can be connected to. This provides a convenient alternative to the box type loop detectors that would need to be wired to the Control Board. Loop Rack: Part # VA-LR Loop Rack Wiring Harness: Part # VA-LRH Viking Loop Rack 28V Gnd Exit Center Re-Open Twist Wire Outside the Loop 6 Twists/Foot Until Its Connection to the Loop Rack Open Center Re-Open Exit Center OP CN RO Re-Open Outside Re-Open Loop Center Loop Inside Re-Open Loop Control Board Connector Exit Loop Loop Sensor Connector 30 VIKING TECHNICAL SUPPORT 1.800.908.0884 ACCESSORY CONNECTIONS Guidelines for Loop Installation 1. Prevent sharp corners in the geometry of the loop sensor. 2. Install the appropriate number of turns for your loop geometry based on the loop perimeter. Use the Table below as a guide. 3. Use XLP (cross-linked-polyethylene) type of wire. This wire reduces the effects of moisture and other environmental events in altering the functionality of the vehicular loop detector. 4. Twist the lead wire at least 6 turns per foot. 5. Use BACKER-ROD to minimize damage to the loop detector wire prior to using the sealant. 6. Place the loop detector wire and adjust the sensitivity of the vehicular loop detector unit as needed. ! IMPORTANT! Some of the following parameters may affect the proper functionality of the vehicular loop detector. Consult the manufacturer of the vehicular loop detector and/or loop wire. · Gate size · Number of turns in the loop sensor wire · Distance of the loop sensor wire to the gate Saw Cut 1" Min. Sealant Backer-Rod Vehicular Loop Detector Wire (3 Turns Shown) Recommended Number of Turns Perimeter (ft.) Turns 10 5 20 4 30-40 3 50-100 2 Continuously Wind Wire in Loop Slot for the Required Number of Loops Provide Additional Saw Cuts to Eliminate Sharp Corners 1/8" to 1/4" Saw Slot Twist Wire Outside the Loop 6 Twists/Foot Until Its Connection to the Loop Detector Outside Re-Open Loop A A VIKING TECHNICAL SUPPORT 1.800.908.0884 5' Dimension "A" = 5' for Single Gate 6' for Dual Gate Center Loop 5' 5' 5' Inside Re-Open Loop Make Even with Open Gate Gate in Open Position Exit Loop 31 ACCESSORY CONNECTIONS Magnetic Lock, Lock Solenoid Magnetic Lock Lock Solenoid Power for the Locks: Do not use the 24VDC power supplied by the Control Board. A Class 2 external power supply or plug-in transformer, must be used for the magnetic lock or lock solenoid. This will prevent rapid drainage of the battery in the event of power failure. The control boards "Magnetic Lock" relay is rated for 10A-250VAC. ! TECHNICAL TIP: The Magnetic Lock Relay LED will indicate status of the on-board relay even if a lock is not connected to the Control Board. Refer to page 34. 32 VIKING TECHNICAL SUPPORT 1.800.908.0884 ACCESSORY CONNECTIONS Barrier Arm Synchronization NOTE: The Control Board provides a convenient solution for applications that require synchronized operation with a Barrier Arm Operator. Consult the Barrier Arm operator's documentation for further instructions. This type of application opens and closes in the following pattern: 1. Open Command is provided only to the Barrier Arm operator. 2. The Barrier Arm will send an open input to the Viking gate operator; Barrier Arm will delay to open until the Viking gate operator reaches its Open Limit. 3. Barrier Arm will close first; the Viking gate operator will delay to close until the Barrier Arm reaches its Close Limit. Turn the "Timer" on at the Viking Control Board. STEP 1 (Figure A) At the Barrier Arm operator, connect the device(s) that will be used as the primary OPEN input. STEP 2 Connect the Barrier Arms' designated sync output terminals to the Strike input at the Viking gate operator. 2 4 1 3 STEP 3 At the Viking gate operator, activate Sync Mode by placing a jumper on to the pin headers labeled "SYNC". STEP 4 Connect Magnetic Lock relay terminals ("COM" and "N.C.") to the Barrier Arms' designated sync input terminals. VIKING TECHNICAL SUPPORT 1.800.908.0884 33 TROUBLESHOOTING LED References In addition to the LCD Display, the Control Board LEDs monitor the various circuits of the Control Board. Use the table below to identify the corresponding "TS Ref#" and refer to pages 34-40 for further troubleshooting. # LED 1 "Magnetic Lock Relay" Status OFF SOLID 2 "Check Motor" OFF SOLID 3 "Battery Low" OFF SOLID FLASHING 4 "POWER" SOLID FLASHING OFF 5 "Radio" OFF SOLID 6 "UL" OFF SOLID 7 "Re-Open" OFF SOLID 8 "ATG" 34 OFF SOLID Page 40 Meaning TS Ref#(s) At Closed Limit and Magnetic Lock Relay state is closed across "COM" & "N.C.". (pg 32). Gate should be at the Close Limit. Not at Closed Limit and Magnetic Lock Relay state is closed across "COM" & "N.O.". (pg 32). Gate should not be at the Close Limit Normal Condition. The Control Board is sending power to the motor but the circuit is open. 7, 8 Normal Condition. Batteries are low. Check power supply to the operator. (pg 16-17). 1, 2, 3, 4 Batteries critically low. Check power supply to the operator. (pg 16-17). 1, 2, 3, 4 Normal Condition. Operator is running on batteries only (pg 16-17). 1, 2, 4 No power to Control Board. 1, 2, 4, 5 Normal Condition. Control Board is receiving an input from a device connected to the Radio terminal (pg 26, 28). 9, 10 Normal Condition. Control Board is receiving an input from a device connected to the UL 9, 10, 16, terminal or when more than one device is connected (pg 6-7, 18, 26). 20 Normal Condition. Control Board is receiving an input from a device connected to the Re-Open terminal or when more than one device is connected (pg 6-7, 9, 10, 16, 18, 26, 30). 20 Normal Condition. Control Board is receiving an input from a device connected to the ATG terminal (pg 26). 9, 10 VIKING TECHNICAL SUPPORT 1.800.908.0884 TROUBLESHOOTING LED References # LED Status 9 "C Loop" OFF SOLID 10 "Open" OFF SOLID 11 "STOP" OFF SOLID 12 "Close" OFF SOLID 13 "Siren" 14 "Aux. Pwr" 15 "Diagnose" OFF SOLID FLASHING OFF SOLID OFF FLASHING 16 "Close Limit" OFF SOLID FLASHING 17 "Open Limit" OFF SOLID FLASHING 18 "ODS" OFF SOLID FLASHING 19 "Timer" OFF SOLID FLASHING 20 "AC VOLTAGE INPUT" SOLID OFF 21 "PROTECTION WORKING" SOLID OFF 22 "AC VOLTAGE OUTPUT" SOLID OFF 23 "AC POWER" SOLID OFF Pg 40 Meaning TS Ref#(s) Normal Condition. Control Board is receiving an input from a device connected to the C Loop terminal (pg 26, 30). 9, 10 Normal Condition. Control board is receiving an input from a device connected to any of the following input terminals: Exit, Fire, Strike or Open (pg 26, 30). 9, 10 Normal Condition. Control Board is receiving an input from a device connected to the Stop terminal (pg 26). There is a problem with the required monitored sensor(s) connected to the "UL" and/or "Re-Open" input terminals (pg 6-7, 18) 9, 10 16, 20 Normal Condition. Control Board is receiving an input from a device connected to the Close terminal (pg 26). 9, 10 Normal Condition. Second consecutive obstruction has been detected. (pg 22, 24). Batteries are critically low. 1, 2, 11-13 1, 2, 4 No voltage output on these terminals at the moment. There is 24VDC output on these terminals at the moment. Normal Condition. Errors have been detected; Check LCD Display for ERR messages (pg 3839). Gate is not at the close limit position. Gate is at the close limit position. Check for correct operator model number on LCD Display. 6 Gate is not at the open limit position. Gate is at the open limit position. Check for correct operator model number on LCD Display. 6 Normal Condition. Obstruction has been detected. (pg 24). 1, 2, 11,-13 Overload has been detected. (pg 24). 1, 2, 12-13 If gate is at the open limit, the Timer to close is turned OFF. (pg 22) Timer to close is ON and counting down to close the gate. (pg 22) 7LPHULV21EXWLVQRWWLPLQJRXWGXHWRDFRQµLFWLQJFRPPDQGSJ 9, 10 Normal Condition. ,QFRPLQJSRZHUWR3RZHU6XSSO\3DQHO$VVHPEO\LVQRWVXI´FLHQWSJ 1 Normal Condition. EMI Board is damaged and circuit is not protected . Replace EMI Board. Normal Condition. There is no output voltage from the Power Supply Panel Assembly. 2 Normal Condition for High Voltage installations. High Voltage is not supplied to the Modular Power Box (pg 16). 1 VIKING TECHNICAL SUPPORT 1.800.908.0884 35 TROUBLESHOOTING LCD Display References The Control Board is equipped with a LCD Display that provides operator information, current conditions, settings, diagnostics and error messages. Use the table below to identify the corresponding "TS Ref#" and refer to pages 34-40 for further troubleshooting. Press the Diagnose button to manually scroll through all of the Messages. NOTE: (UURU0HVVDJHVZLOOEHGLVSOD\HG´UVW 7KH«'LDJQRVH«/('ZLOOµDVKFRQVHFXWLYHO\ indicating how many Error Messages are available. LCD MSG Meaning MODEL F-1 Indicates the Model of the unit System Status Messages GATE IS IDLE GATE IS OPENING GATE IS CLOSING GATE IS OPENED GATE IS CLOSED STOP BY OBSTRUCT STOP BY OVERLOAD OVERLAP TIMING HOLDING __ SEC RED CONN UNPLUGED Gate is stopped between limits Gate is opening Gate is closing Gate is at the limit open position Gate is at the limit close position Gate has stopped due to an obstruction of the gate system. Also refer to the "ODS" LED. (pg 22, 24, 34 @ #4, 35 @ #18) Gate has stopped due to an overload of the gate system. Also refer to the "ODS" LED. (pg 22, 24, 34 @ #4, 35 @ #18) Gate is waiting for the overlap time Gate is at the limit open position and timing to close - The display shows the actual time left before closing The Motor Connector is not plugged into the red Open Left or Open Right socket at the Control Board. (pg 19) Page 40 TS Ref #s 6 11, 12, 13 11, 12 10 21 36 VIKING TECHNICAL SUPPORT 1.800.908.0884 LCD Display References LCD MSG Meaning Multi Meter Displays TROUBLESHOOTING Page 40 TS Ref #s MOT AMP __._ A MOT VOLT __._ VDC AC VOLT __._ VAC CHARGE __._ VDC BAT VOLT __._ VDC This is the motor current amperage during operation. At Idle, should be 0.0 A. This is the actual motor voltage during operation. At Idle, should be 0.0 VDC. This is the actual low voltage AC to the Control Board from the transformer Indicates the charging voltage to the batteries, With the Battery Switch in the OFF position, should be between 26.0 - 28.0 VDC. Indicates battery voltage, if the AC power is discontinued to the Control Board. Board Settings Messages Speed __ % Shows the percentage of speed set by the Speed adjustment on the Control Board. (pg 22) OVERLAP _._ SEC Shows the number of seconds set by the Overlap Adjustment on the control board. This feature is not available on slide gate operator models ODS SENS ___% Shows the force setting selected to trip the obstruction sensor. (pg 22, 24) TIMER __ SEC Shows the amount time set or remaining to hold the gate at the Open Limit position, before the gate starts to close. (pg 22) HEATER ___ OFF The Integrated Heater is disabled for the open "OPN" and/or close "CLS" limits (pg 25) HEATER ___ ON The Integrated Heater has been enabled to turn on at the open "OPN" and/or close "CLS" limits (pg 25) "ACTV" will also be displayed while it is heating. LOCK MOD ___ The Lock Mode feature is turned ON or OFF (pg 25) UL LEARN UL_ RO_ Indicates the number of connected Monitored Entrapment Protection Sensors that are being monitored. NO LEARN = no sensors learned. (pg 6-7, 18) 20 VIKING TECHNICAL SUPPORT 1.800.908.0884 37 TROUBLESHOOTING LCD Display References LCD MSG Meaning Error Messages Page 40 TS Ref #s ERR AC LOW ERR AC HIGH ERR AC NO AC ERR CHRG HIGH ERR CHRG CHECK 4A ERR BAT LOW ERR FUSE 15 AMP ERRLIMIT OPN+CLS ERR EMI NO EMI ERR EMI NO FUSE ERR EMI NO AC ERR EMI Unknown ERR EMI PROTECT ERR REFV WRONG ERR SENS UL RO Indicates that the 24VAC supply to the VFlex Board is too low from the 115/230 power supply. 1, 3, 19 Indicates that the 24VAC supply to the VFlex Board is too high from the 115/230 power supply. 1, 3, 19 Indicates that there is no 24VAC supply detected to the VFlex Board from 1, 2, 4, the 115/230 power supply. 19 Potential problem with the charging voltage from the Control Board. 1, ? a) 4 Amp Fuse is blown at the Control Board or; b) There is a problem with the batteries or the Control Board. The voltage from the batteries is low. 18, ? 1-4, 18, 19 15 Amp motor fuse is blown. 7, 11, 12 There is a problem with the Limit Switches or Wires. 22 No EMI board detected. 15 4 Amp main fuse is blown on Power Supply Panel Assembly. 2 There is no AC voltage detected at the Power Supply Panel Assembly. 1, 4, 15 There is a problem with the communication between the EMI Board and the VFlex Board. 15 Lightning strike protection for the EMI Board (behind the Power Supply Panel Assembly) needs to be replaced ? One, or more, of the Control Board internal reference voltages are incorrect. ? There is a problem with the required monitored sensor(s) connected to the "UL" and/or "Re-Open" input terminals (pg 6-7, 18). 20 38 VIKING TECHNICAL SUPPORT 1.800.908.0884 (THIS PAGE LEFT BLANK INTENTIONALLY) VIKING TECHNICAL SUPPORT 1.800.908.0884 39 TROUBLESHOOTING Solutions Begin the troubleshooting process by referring to the error messages on the LCD Display and/or the Status LEDs on the Control Board. Use pages 34-39 to identify the Troubleshooting Reference # (TS Ref#) then reference the table below. TS Ref# CHECK Page Ref# 1 Check that the high voltage power supplied to "J-Box" is within range. 100V-120V or 200V-240V pg 16-17 2 At the Power Supply Panel Assembly, remove and check 4A Fuse for continuity. pg 16-17 3 Check that to the high the "Voltage Selector", on the Power Supply voltage power supply. 115VAC or 230VAC Panel Assembly, is set according pg 16-17 4 Check the main power breaker and "AC POWER" switch (if applicable) are on. pg 16-17 5 Check that the Power Harness is connected to the Control Board. pg 11, 16-17 6 Perform a soft reset by momentarily actuating both limit switches simultaneously. pg 19 7 Check Motor Fuse on the Control Board. pg 11 8 Check for an open circuit to the Motor and that the operator is not in Manual Release mode. pg 7, 10 9 Check the Status LEDs and LCD Display to determine if the Control Board is receiving an pg 22, 24, input from any external devices or if the "ODS" has been triggered. 34-36 10 Remove the external devices from the Control Board to determine if the Control Board is pg 26-30, responding to an input or problem with the external device or wiring. 34-35 11 Check the "ODS" setting on the Control Board. pg 4, 22, 24 12 Check that the gate can be moved manually of travel. Check gate track rollers, chain and with low resistance throughout hinges as applicable. its full length pg 4, 7 13 Check the limit position. pg 19 14 Not applicable to this model. 15 Check the EMI Cable and contacts between the EMI Board and the VFlex Board. 16 Check that the LCD Display for Error Messages 17 Not applicable to this model. 18 Check 4 Amp fuse on the Control Board 19 Check for 24VAC out from the Toroidal Transformer and Power Harness. 20 Check the required entrapment protection sensors. 21 Check that the Motor Harness Connector is connected to the Control Board. 22 Check the Limit Switches and Wires. Both limit circuits are to be N.C. 23 Not applicable to this model. 24 Not applicable to this model. 25 Not applicable to this model. 26 Not applicable to this model. ? Call Viking Technical Support for further assistance. pg 11 pg 38, 39 pg 11 pg 16-17 pg 3, 6-7, 18 pg 11, 19 pg 19 40 VIKING TECHNICAL SUPPORT 1.800.908.0884 Item Description 1 Operator Cover Bolt (4) 2 Operator Cover 3 Output Shaft Knob 4 Output Shaft Cover 5 Clutch Key 6 Clutch and Handle 7 Output Arm 8 Output Shaft 9 Control Board 10 Fuse - 15 amp 11 Fuse - 4 amp 12 Limit Switch Holder 13 Limit Switch (2) 14 Limit Cam & Holder 15 Worm Gear #70 10:1 16 Sprocket (Gearbox) 17 Chain #40x46 Pitches 18 Sprocket (Motor) 19 24V DC Gearhead Motor 20 Brush Kit 21 Chassis 22 Loop Rack 23 Battery Switch 24 Motor Switch 25 Battery 26 Modular Power Box Assembly 27 Toroid Transformer - 10 amp 28 Power Box Panel Assembly 29 120V Receptacle 30 Main Power Switch 31 Alarm 32 Power Harness 33 Limit Switch Harness 34 Multi-Part Arm Assembly (Standard) Part No. VASWCB VNXF1CV DWOUK10 VNXSWOSC VAWRCK20 DWCL20 DWAR20 DWOP20 VFLEXPCBU18 VNXF15A VNXF4A DWLH10 DULS10 DWLC10B DWGB70 VASP3034 DWCA10 VASP1034 VAF1MO VAMBK VNXF1CH VA-LR DUMRS10 DUMRS10 DUBA12 VNXMPBF1 DUTT10 VNXUPBPA VA120PL DUMRS10 DUAL10 VNXSWPH VNXF1LSH VA-F1ARM20 PARTS DIAGRAM: VIKING TECHNICAL SUPPORT 1.800.908.0884 41 LIMITED WARRANTY )$$&,QWHUQDWLRQDO,QFª6HOOHU«ZDUUDQWVWKH´UVW3XUFKDVHURIWKHSURGXFWWREHIUHH from defects in material and workmanship IRUDVSHFL´FSHULRGDVGH´QHGE\WKH:DUUDQW\ Disclosure on the website www.vikingaccess.com. The Warranty Period commences from the date of invoice. Control Boards, Accessories or Spare Parts factory installed or sold with any of the products above carry the same warranty period as the product they are sold with, excluding batteries that carry a maximum 2 year warranty. Accessories or spare parts sold separately have a 1-year warranty period. Products repaired under warranty carry the remainder of the original warranty period. For products repaired outside of warranty, the Seller warrants that all parts used for the repair will be free from defects in materials and workmanship for a period of ninety (90) days. Defective products must be returned to Seller, freight prepaid by Purchaser, within the warranty period. A Return Material Authorization Number (RMA) must be obtained before product is returned. Items returned will be repaired or replaced, at Seller's option, upon an examination which discloses to the satisfaction of the Seller that the item is defective. The Seller will return the warranted item freight prepaid. This limited Warranty covers the product under the normal use and service for which it was intended, provided it has been properly installed and operated. Seller's obligations under this warranty shall be limited to the repair or exchange of any part. This warranty shall not apply to products or parts thereof which have been repaired or altered, without Seller's written consent, outside of Sellers's workshop or altered in any way so as, in the judgment of Seller, to affect adversely the stability or reliability of the product(s) or has been subject of misuse, negligence, or accident, or has not been operated in accordance with the product's instructions or has been operated under conditions more severe than, or RWKHUZLVHH[FHHGLQJWKRVHVHWIRUWKLQWKHVSHFL´FDWLRQVIRUVXFKSURGXFWV When the warranty service involves the exchange of an operator or part, the item the Seller replaces becomes its property and the replacement becomes Purchaser's property. The Purchaser represents that all removed items are genuine and unaltered. The replacement may not be new but will be in good working order and at least functionally equivalent to the item replaced. The replacement assumes the warranty service status of the replaced item. 7KHSURGXFWVDUHQRWZDUUDQWHGWRPHHWWKHVSHFL´FUHTXLUHPHQWVLIDQ\RIVDIHW\FRGHV of any particular state, municipality, or other jurisdiction, and the Seller doesn't assume any risk or liability whatsoever resulting from the use thereof, whether used singly or in combination with other machines or apparatus. The Seller does not assume nor authorizes any person to assume for them any other liability in connection with the sale or use of the products of beyond that extended herein. The warranty hereinabove set forth shall not be deemed to cover maintenance parts, including, but not limited to hydraulic oil, motor brushes, or the like. No agreement to replace or repair shall constitute an admission by the Seller of any legal responsibility to effect such replacement to make such repair, or otherwise. 42 VIKING TECHNICAL SUPPORT 1.800.908.0884 $OOSURGXFWVVROGE\WKH6HOOHUDUHVXEMHFWWRGHVLJQDQGRUDSSHDUDQFHPRGL´FDWLRQV which are production standards at the time of shipment. The Seller may, but shall not be required to, modify or update products shipped prior to a current production standard. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE. THIS WARRANTY SHALL NOT APPLY TO PRODUCTS OR ANY PART THEREOF WHICH HAVE BEEN SUBJECT TO ACCIDENT, NEGLIGENCE, ALTERATION, ABUSE, OR MISUSE OR IF DAMAGE WAS DUE TO IMPROPER INSTALLATION OR USE OF IMPROPER POWER SOURCE, OR IF DAMAGE WAS CAUSED BY FIRE, FLOOD, LIGHTNING, ELECTRICAL POWER SURGE, EXPLOSION, WIND STORM, HAIL, AIRCRAFT OR VEHICLES, VANDALISM, RIOT OR CIVIL COMMOTION, OR ACTS OF GOD. The Seller shall not be liable for any loss or damage whatsoever resulting, directly or indirectly, from the use or loss of use of the product(s). Without limiting the foregoing, this exclusion from liability embraces a Purchaser's expenses for downtime or for making XSGRZQWLPHORVWSUR´WGDPDJHVIRUZKLFKWKH3XUFKDVHUPD\EHOLDEOHWRRWKHUSHUVRQV damage to property, and injury to or death of any persons. This limited warranty extends only to wholesale customers who buy directly through the Seller's normal distribution channels. The Seller does not warrant its products to end consumers. Consumers must inquire from their selling dealer as to the nature and extent of that dealer's warranty, if any. THE LIMITED WARRANTY OFFERED HEREIN IS THE SOLE AND EXCLUSIVE REMEDY AVAILABLE TO THE PURCHASER. CORRECTION OF DEFECTS, IN THE MANNER AND FOR THE PERIOD OF TIME DESCRIBED HEREIN, SHALL CONSTITUTE THE COMPLETE FULFILLMENT OF ALL LIABILITIES OF SELLER TO THE PURCHASER WITH RESPECT TO THE COVERED PRODUCT, AND SHALL CONSTITUTE FULL SATISFACTION OF ALL CLAIMS, WHETHER BASED ON CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHERWISE. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY LOSS OF PROFITS OR ANY INDIRECT, CONSEQUENTIAL, INCIDENTAL, SPECIAL OR PUNITIVE DAMAGES ARISING OUT OF SELLER`S BREACH OF THIS LIMITED WARRANTY, OR ARISING OUT OF THE CUSTOMER'S INABILITY TO USE THE COVERED PRODUCT, EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to a particular Purchaser. This Limited Warranty JLYHVWKH3XUFKDVHUVSHFL´FOHJDOULJKWV7KH3XUFKDVHUPD\DOVRKDYHRWKHUULJKWVZKLFK vary from state to state. VIKING TECHNICAL SUPPORT 1.800.908.0884 43 VIKING EXPANSION PRODUCTS VIKING KONNECT Primary/Secondary Kit Secure and reliable Primary/Secondary communication between two single gate operators or ECU's using Viking's Konnect technology. Part# VA-KONNECT-MS ***Q-7 & ECU Operators require (2) Antenna Extension Cables (part# VA-RPSMA)*** *** NOT COMPATIBLE for Solar Mode setting on Control Board (if applicable)*** VIKING MONITOR Off-site access to operator diagnostics. With the Viking Monitor App, this tool allows you to monitor and label multiple operators by site and location for quick reference. Provides error notifications, operator status, settings and diagnostic information. Part# VA-MONITOR ***Q-7 & ECU Operators require (1) Antenna Extension Cable (part# VA-RPSMA)*** VIKING AC SURGE PRO Adds another layer of protection to the high voltage power supply of your gate operator. Connecting the AC Surge Pro in parallel to the EMI Board, provides a dual layer of protection from surges up to 20,000 Volts / 10,000 Amps. Part# VA-SURGEPROAC VIKING 24V SOLAR KIT The components included in this package are intended to provide sufficient power for general applications. Part# VA-SOCHP This Kit includes the following components: (2) 12V 40W Solar Panels Part# VA-SO40W (wired in series = 24V 80W) (2) 12V 35Ah batteries Part# DUBA35 (wired in series = 24V 35Ah) (1) Solar Charger Part# SOCHR10 (1) Solar Power Harness Part# SOHAR ! NOTE: The number of cycles achieved from this kit are dependent upon the following and may require increased panel and battery capacities: · Power consumption of all accessories being used · Average solar radiation of geographic location 44 VIKING TECHNICAL SUPPORT 1.800.908.0884 OUR CONTINUOUS COMMITMENT TO EXCELLENCE Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and its needs. As technology continues to advance, we have developed a completely HI´FLHQW DQG LQWHOOLJHQW OLQH RI JDWH RSHUDWRUV WR PHHW WKH FKDQJLQJ demands. These machines offer: full UL325 and UL991 compliance, soft-start and soft-stop, intelligent obstruction sensors, continuous RSHUDWLRQGXW\F\FOHDQGH[WUHPHSRZHUHI´FLHQF\,QQRYDWLYH features include: adaptive and self-learning algorithms, redundancy design in both hardware and software to ensure operation and functionality, protection from lightning, short circuit and power surges, DQGRXUH[FOXVLYHKHOLFDOJHDULQJRIIHULQJWKHKLJKHVWHI´FLHQF\UDWLQJ LQ WKH LQGXVWU\ 2XU HQWLUH SURGXFW OLQH LV FRQWLQXDOO\ PRGL´HG DQG improved based on the latest technology and our customer's valuable IHHGEDFN 7KH UHVXOWV DUH SURGXFWV WKDW RIIHU DFFXUDF\ HI´FLHQF\ reliability and performance, all in sleek, high-tech designs. We pledge to continue establishing ourself as the leader in high quality, innovative gate operators by developing "Next Level" technology. We are committed to providing safety and convenience with innovative solutions for every security gate need. INSTALLATION DATE: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ COMPANY / INSTALLER: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ CONTACT: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ SERIAL NUMBER(S): ____________________________________ ALL I N STALL ATION , MAI NTENAN CE AN D R EPAI R WOR K M UST B E DOCUMENTED AND MADE AVAIL ABLE TO THE USER . VIKING ACCESS SYSTEMS 631 Wald Irvine, CA 92618 Phone 800.908.0884 Fax 949.753.1640 www.vikingaccess.com