Owner's Manual for Gibson models including: G7S A K, KG7S A K, G7S A and K Series Single Stage Upflow Horizontal and Downflow Gas Furnaces, G7S A and K Series, Single Stage Upflow Horizontal and Downflow Gas Furnaces, Upflow Horizontal and Downflow Gas Furnaces, Horizontal and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces, Furnaces
KG7S(A,K) | Gas Furnace | Gibson | Literature Library
File Info : application/pdf, 8 Pages, 575.48KB
DocumentDocumentTECHNICAL SPECIFICATIONS G7S (A and K Series) Single Stage Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000 - 126,000 Btuh The gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing "appliance appearance." Design certified by CSA for application in Canada and the United States. This furnace series is approved and certified by the SCAQM and the SJVAPC Districts in the state of California under each Districts' Mitigation Fee Plan for shipment into and sales in both districts. For California installations in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. FEATURES and BENEFITS · 100% fired and tested: All units and each component are tested on the manufacturing line. · Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free. · Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install. · Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life. · 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds). · 30 second post purge: Increases life of heat exchanger. · Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology. · Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement. · High static blowers: All models equipped with high static blowers. · 60 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil. · Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances. · Multi-speed direct drive blower: Energy-efficient, brushless DC (ECM). Designed to give a wide range of cooling capacities. Dip switches on PCB provide easy motor speed selection. · LP convertible:Simple burner orifice and regulator spring change for ease of convertibility. · Integrated control board: Incorporates connections for electronic air cleaner and humidifier. Ergonomically located for ease of service. · Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws. · Blower Compartment: Insulated for ultra quiet operation. · Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it's needed. GAS FURNACE COMPONENTS Combustion Tube 9 12 11 14 8 2 Upflow/Horizontal Gas Furnace 1 2 10 9 12 14 8 2 4 1. Blower Assembly 7 2. Blower Door Switch 13 3. Burner Assembly 5 4. Control Board 6 5. Flame Sensor 3 6. Gas Manifold 1 7. Gas Valve 8. Igniter 4 9. Inducer 11 10. Insulated Combustion Tube (Downflow Models) 13 11. Low Voltage Transformer 7 12. Main Air Limit Switch 5 13. Pressure Switch 6 14. Roll-Out Switch(s) 3 DIMENSIONS TOP VIEW C *SA Dimension Dimension Dimension Dimension Model #'s "A" "B" "C" "D" 045-23A 054-23A 14 ¼ 10 ¾ 12 12 072-24B 090-24B 17 ½ 11 ¾ 15 16 072-35C 090-35C 21 108-35C 14 19 19 126-45D 24 ½ 15 ¼ 22 23 23 FLANGES 19 B Accepts 4" Type B Vent Pipe 25 3/8 A Gas Electric (1 5/8 X 3 1/2) (Ø 7/8) 4 Knockouts (both sides) T-stat (Ø 7/8) Electric (Ø 7/8) 1 1/4 23 LEFT SIDE 23 15 1 FRONT VIEW G7SA Single Stage Upflow/Horizontal Series 23 1/2 BOTTOM VIEW D Front Brace Bottom Panel 22 1/4 25 21 3/4 (1 Gas 5/8 X 3 1/2 X 45°) 28 RIGHT SIDE 29 1/2 22 1/2 22 3/4 34 1/2 *SK Dimension Dimension Dimension Dimension Model #'s "A" "B" "C" "D" 054-23A 14 ¼ 10 ¾ 12 12 072-24B 090-24B 17 ½ 11 ¾ 15 16 108-35C 21 14 19 19 126-45D 24 ½ 15 ¼ 22 23 Electric (Ø 7/8) TOP VIEW C 23 FLANGES 19 B Accepts 4" Type B Vent Pipe A Gas (1 5/8 X 3 1/2) BOTTOM VIEW D Front Brace 18 5/8 T-stat (Ø 7/8) Electric (Ø 7/8) 22 1/4 25 Gas (1 5/8 X 3 1/2 X 45°) 29 1/2 22 1/2 34 1/2 22 1/2 25 3/8 7 28 LEFT SIDE FRONT VIEW 7 RIGHT SIDE G7SK Single Stage Downflow Series 3 MODEL IDENTIFICATION CODE Gas Furnace Design Series S = Single Stage T = Two Stage M = Modulating A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal D = 95% Upflow/Horizontal E = 96% Upflow K = 80% Downflow L = 92.1% / 95.1% Downflow M = 95% Downflow N = 96% Downflow Q = 96.4+% AFUE Upflow/Horizontal G 7 S A 045 C T 23 A 1 Revision Input Heating Capacity 045 = 45,000 054 = 54,000 072 = 72,000 090 = 90,000 108 = 108,000 126 = 126,000 Cabinet Width A = 14.25 B = 17.50 C = 21.00 D = 24.50 Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons Motor Technology V = VSHE E = FSHE T = 5 Tap ECM NOx C/D = 40 Ng/J or less NOx U = 14 Ng/J or less NOx SPECIFICATIONS G7SA MODEL NUMBERS -045-T23A1 -054-T23A1 -072-T24B1 -072-T35C1 -090-T24B1 -090-T35C1 -108-T35C1 -126-T45D1 Input - Btuh (a) 45,000 52,000 70,000 75,000 90,000 85000 108000 122000 Heating Capacity - Btuh 36,000 42,000 56,000 60,000 72,000 68000 86000 98000 AFUE 80.0 80.0 80.0 80.0 80.0 80 80 80 Motor H.P. - Speed - Type 1/2 - 5 - ECM 1/2 - 5 - ECM 3/4 - 5 - ECM 3/4 - 5 - ECM 3/4 - 5 - ECM 3/4-5-ECM 1-5-ECM 1-5-ECM Motor FLA 6.4 6.4 8.8 8.8 8.8 8.8 11.5 11.5 Rated Ext. SP - In. W.C. 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Temperature Rise Range - ºF 30-60 30-60 30-60 35-65 35-65 35-65 35-65 40-70 Shipping Weights 95 lbs 95 lbs 110 lbs 115 lbs 115 lbs 134 lbs 136 lbs 147 lbs G7SK MODEL NUMBERS -054C-T23A1 -072-T24B1 -090-T24B1 Input - Btuh (a) Heating Capacity - Btuh AFUE Motor H.P. - Speed - Type Motor FLA Rated Ext. SP - In. W.C. 54,000 72,000 90,000 43,000 58,000 72,000 80.0 80.0 80.0 1/2 - 5 - ECM 3/4 - 5 - ECM 3/4 - 5 - ECM 6.4 8.8 8.8 0.5 0.5 0.5 Temperature Rise Range - ºF 30-60 35-65 35-65 Shipping Weights 102 lbs 110 lb 115 lb 4 ACCESSORIES G7S(A,K) KITS Description "A" Cabinet downflow sub base kit "B", "C", "D" Cabinet downflow sub base kit U.S. LP Conversion kit (0 to 10,000 ft.) and High Altitude LP Canada LP Conversion kit (0 to 4,500 ft.) and High Altitude LP Side return filter kit Furnace Twinning Kit SKU 902974 904911 905028 905029 541036 1010035 5 6 7 GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (04/2022) 575F-0422 (Replaces 575F-0220) www.gibsonhvac.com GIBSON is a pending or registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved. Powered by TCPDF (www.tcpdf.org)