EEC Power Sources

Powering Production.®

Manual • Automated • Programmable

April 2023 V1.1

Our Story

Since 1978 EEC has been providing AC Power Sources for the power conversion industry. Our commitment to quality, innovation, and customer service has helped set the expectation for the industry. In 2020 EEC introduced the 8500 Series Power Source, the world's highest power density single phase AC Source. As of 2021, EEC joined the Ikonix Family to become an Ikonix brand, where it continued to innovate and shape the power conversion industry.

A History of Innovation

1978: EEC is founded in Taipei City, Taiwan.

1979: Introduced the CFC Series AC power source and became the first AC power Source/Inverter professional manufacturer in Taiwan.

1988: Introduced the CFC-100W Series Digital AC power sources.

1991: The first Ikonix investment in EEC.

1994: EEC became the sole manufacturer of Battery Charges for the Taiwan military – General Headquarters of Combined Service Force. Collaboration with Associated Research, Inc. (An Ikonix Brand) to become an ODM partner.

2001: Expanded into Suzhou, China and Japan.

2002: Introduced the 6300/6400/6500 High Power Switch Mode Power Supplies.

2008: Moved the Taipei headquarters to a larger facility in Taipei Neihu Technology Park.

2009: Announced the 61000 Series Programmable Power Source.

2020: Introduced the 8500 Series Power Source – the world's highest power density single phase AC source.

2021: The final Ikonix purchase of all EEC shares. EEC joins the Ikonix family to become an Ikonix Brand.

Customer Happiness Promise

EEC aims to provide an amazing experience and quality testers that last a long time. If a customer is not satisfied with their power source, it can be returned within 45 days for a full refund. Annual calibration with EEC or an authorized partner extends the warranty an additional year for the service life of the power source, and at least five years after discontinuation. If the product breaks during that time, EEC promises to fix it for free (unless abuse or excessive damage is present). When a power source reaches the end of its service life, EEC will responsibly recycle it and offer a discount on a replacement.

[Annual calibration and inspection must be made in each successive year starting one year after the original purchase date in order to remain eligible for extended warranty coverage beyond the standard warranty period (five years).]

[5-star rating] CUSTOMER HAPPINESS

5 Year Warranty

Your new power source is warranted to be free from defects in workmanship and material for a period of (5) years from date of shipment.

**5 year warranty is valid on any model purchased in 2021 or after.

Ongoing Support

EEC works to provide the best service and support in the industry. With decades of industry experience, EEC is a trusted partner to help customers be compliant to NRTL standards. EEC works closely with customers to help them achieve their goals and has built a worldwide network of knowledgeable partners, ensuring coverage no matter where they are.

Call +1-847-367-4077

Product Reference Chart

Model Output Power Capability Output Configurations
500 VA 1.25 kVA 2 kVA 3 kVA 4 kVA 6 kVA 1 Phase Split 1 Phase (2 Lines/1 Neutral) 3 Phase
430XAC ✔️ ✔️
460XAC ✔️ ✔️
8505 ✔️ ✔️
8512 ✔️ ✔️
8520 ✔️ ✔️
8530 ✔️ ✔️
8540 ✔️ ✔️
8560 ✔️ ✔️
Model Voltage Output Max Frequency Output Range Max A @ <110V/220V (per phase) PC Control CE Mark Free GUI Available
430XAC 300/600/520* 40-1000 9.2A/4.6A ✔️ ✔️ ✔️
460XAC 300/600/520* 40-1000 18.4A/9.2A ✔️ ✔️ ✔️
8505 310 5.0-1200 5.0A/2.5A ✔️ ✔️ ✔️
8512 310 5.0-1200 12.5A/6.25A ✔️ ✔️ ✔️
8520 310 5.0-1200 20A/10A ✔️ ✔️ ✔️
8530 310 5.0-1200 30A/15A ✔️ ✔️ ✔️
8540 310 5.0-1200 40A/20A ✔️ ✔️ ✔️
8560 310 5.0-1200 60A/30A ✔️ ✔️ ✔️

*x2 = the number of sources required to achieve an output rating. x3 = the number of sources required to achieve an output rating and 3 phase. 300/600/520* = 300V phase 1Ø, 600V split 1Ø, 520V 3Ø

8500 Series Programmable AC Power Source

The EEC 8500 Series is the most power dense and functionality rich power source in EEC's history, offering improved capability, functionality, and a reduced footprint. This series is manufactured for simulating common grid faults, voltage dips, and other power abnormalities. The 8500 Series provides an output voltage up to 310VAC and an output frequency ranging from 5 Hz – 1,200 Hz, making it a versatile solution for many applications. It features an enhanced interface designed with the end-user in mind. EEC 8500 Sources can be configured as a simple AC Power Source in MANUAL mode, as an upgraded option with Standard mode, or incorporating all functions with Advanced Mode. Advanced mode enables sweeps of voltage, frequencies, transients, and DC bias over a single sequence or multiple tests. The 8500 Series includes the following models: 8505, 8512, 8520, 8530, 8540, & 8560.

Features

  • 14 pre-configured waveforms allow simulation of nearly any abnormal condition on the DUT by selecting the desired waveform.
  • With expanded output voltage to 310VAC and output frequency from 5Hz to 1200Hz, the 8500 provides a single, simple solution for a wide variety of testing applications.
  • Advanced mode option allows easy simulation of voltage surges, voltage drops, voltage pulses, voltage sweeps, DC bias, and frequency sweeps to meet specific testing application needs.
  • High power density with a reduced overall footprint offers flexibility for benchtop or rack mount applications.
  • Legacy Mode allows retention of command sets from 6000, 7000, or 300XAC series.

Image of the front panel of an EEC 8500 Series AC Power Source, displaying voltage, current, and frequency settings, along with control buttons and a rotary knob.

Applicable Industries

  • Aerospace
  • Appliance
  • Laboratory
  • Networking
  • System Integrator
  • LED Lighting
  • Medical

EEC Benefits

  • 5 Year Warranty
  • 1 Day Guaranteed Shipment

Standard & Options

  • Standard: USB/RS-232 Interface, Ethernet Interface
  • Options: GPIB Interface

8500 Series Specifications

Modes

INPUT MANUAL MODE STANDARD MODE ADVANCED MODE
Manual Operation ✔️ ✔️ ✔️
PC Interface (USB/LAN standard, optional GPIB) ✔️ ✔️
PowerTRAC Compatibility ✔️ ✔️
Voltage, Frequency, Transient, and DC Bias Sweeps ✔️

AC Output Specifications

MODEL 8505 8512 8520 8530 8540 8560
AC OUTPUT
Phase
Power Rating 500VA 1250VA 2kVA 3kVA 4kVA 6kVA
Voltage Range 0 - 310V, 155/310V Auto Range
Resolution 0.1V
Accuracy2 ±(0.2% of setting + 3counts) ±(0.2% of setting + 6counts)
Max. Current (r.m.s)1 5A 12.5A 20A 30A 40A 60A
(0-155V) 2.5A 6.25A 10A 15A 20A 30A
(0-310V) DC, 5 - 1200Hz Full Range Adjust 0.1Hz at 0.0 - 999.9Hz , 1Hz at 1000 - 1200Hz
Frequency Range ±0.03% of setting(≥ 15Hz), ±0.3% of setting(<15Hz)
Resolution ± 0.3% @ 50/60Hz (Full Resistive Load)
Accuracy2 ≥ 3 ≥ 3 ≥ 3 2.5 ≥ 3 2.5
Total Harmonic Distortion (THD)3 4 4 4 3 4 3
Crest Factor4 ± 0.1V
Inrush Current ±0.2V,<1s response time
Line Regulation
Load Regulation5

DC Output Specifications

8505 8512 8520 8530 8540 8560
DC OUTPUT
Power rating 300W 750W 1200W 1800W 2400W 3600W
Voltage Range 0 - 420V, 210/420V Auto Range
Resolution 0.1V
Accuracy2 ±(0.2% of setting + 3counts) ±(0.2% of setting + 6counts)
Max. Current (r.m.s)2 3.0A 7.5A 12.0A 18.0A 24.0A 36.0A
(0-210V) 1.5A 3.75A 6.0A 9.0A 12.0A 18.0A
(0-420V) L < 700mV < 800mV
Ripple and Noise (r.m.s)6 H < 700mV < 800mV
Ripple and Noise (p-p)6 < 6.0Vp-p < 7.0Vp-p
Load Regulation5 ±0.2V,<1s response time

Settings & Measurements

Settings

MODEL 8505 8512 8520 8530 8540 8560
SETTINGS
Start/End Angle 0-359
Current Hi Limit (OC Fold=OFF) 0.05-5.00A 0.05-12.50A 0.05-20.00A 0.10-30.00A 0.10-40.00A 0.10-60.00A
(0-155V) 0.05-2.50A 0.05-6.25A 0.05-10.00A 0.10-15.00A 0.10-20.00A 0.10-30.00A
(0-310V) 0.01A
Resolution ± (2.0% of setting + 4 counts)
OC Fold Back Response Time7 < 1.4s
Time Range 1.0 - 999.9h / 1.0 - 999.9m / 1.0 - 999.9s / 0.2 - 999.9ms
Resolution 0.1h/ 0.1m/ 0.1s/ 0.1ms
Accuracy ± (0.1% + 0.1 h) / ± (0.1% + 0.1 m) / ± (0.1% + 0.1 s) / ± (0.1% + 0.1 ms)
Time unit h, m, s, ms
Ramp up Range 0.1 - 999.9s, 0 = OFF
Resolution 0.1s
Accuracy ± (0.1% + 1 Cycle) at Output frequency ≤ 10Hz / ± (0.1% + 0.1 s) at Output frequency > 10Hz

Input Specifications

Phase Voltage Max. Current Frequency Power Factor8
100 - 240 V ± 10% 8A 50 / 60 Hz ≥ 0.93
200 - 240 V ± 10% 18A
1Ø or 3Ø 1Ø: 200~240 VAC ± 10%
3Ø3W: 200~240 VAC ± 10%
3Ø4W: 346~416 VAC ± 10%
30A
≥ 0.97
1Ø: 45A/3Ø3W:
38A
3Ø4W: 22A

Measurement Specifications

8505 8512 8520 8530 8540 8560
MEASUREMENT
Voltage(AC) Range 0 - 310V, 155/310V Auto Range
Resolution 0.1V
Accuracy2 ±(0.2% of reading + 3counts) at voltage > 5V ±(0.2% of reading + 6counts) at voltage > 5V
Voltage(DC) Range 0 - 420V, 210/420V Auto Range
Resolution 0.1V
Accuracy2 ±(0.2% of reading + 3counts) at voltage > 5V ±(0.2% of reading + 6counts) at voltage > 5V
Current9 Range L 0.050 - 1.200A 0.050 - 5.000A 0.050 - 20.00A 0.10 - 37.50A 0.10 - 50.00A 0.10 - 75.00A
Resolution L 1.00 - 6.25A 4.00 - 15.62A 4.00 - 25.00A 0.10 - 15.00A 0.10 - 20.00A 0.10 - 30.00A
Resolution3 0.001A 0.01A
Accuracy2 L ± (1% of reading + 10counts) at CF < 3 ± (0.5% of reading +8counts)
Accuracy2 H ± (0.5% of reading +12counts)
Frequency Range 0.0 - 1200Hz
Resolution 0.1Hz / 1Hz
Accuracy ±0.1Hz @ 5 - 999.9Hz. / ±1Hz @ 1000 - 1200Hz
Power10 (AC,DC) Range L 0.0 - 75.0W 0.0 - 300.0W 240 - 2500W 0 - 3750W 0 - 5000W 0 - 7500W
Range H 60 - 625W 240 - 1563W 240 - 2500W 0 - 3750W 0 - 5000W 0 - 7500W
Resolution L 0.1W 1W
Accuracy2 L ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V ± (2% of reading +15 counts) at PF ≥ 0.35 and voltage > 5V
Accuracy2 H ± (1% of reading +5 counts) at PF ≥ 0.35 and voltage > 5V ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V
Power Factor Range 0.000 - 1.000
Resolution 0.001
Accuracy W/VA, Calculated and displayed to three significant digits
Power Apparent (VA) Range L 0.0 - 75.0VA 0.0 - 300.0VA 240 - 2500VA 0 - 3750VA 0 - 5000VA 0 - 7500VA
Range H 60 - 625VA 240 - 1563VA 240 - 2500VA 0 - 3750VA 0 - 5000VA 0 - 7500VA
Resolution L 0.1VA 1VA
Accuracy V×A, Calculated value
Peak Current Measurement Range L 0.0 - 20.0Apk 0.0 - 50.0Apk 0.0 - 80.0Apk 0.0 - 120.0Apk 0.0 - 160.0Apk 0.0 - 240.0Apk
Resolution 0.1A
Accuracy ± (0.5% of reading +8counts) ± (0.5% of reading +12counts)
Reactive Power Measurement Range L 0.0 - 75.0VAR 0.0 - 300.0VAR 240 - 2500VAR 0 - 3750VAR 0 - 5000VAR 0 - 7500VAR
Range H 60 - 625VAR 240 - 1563VAR 240 - 2500VAR 0 - 3750VAR 0 - 5000VAR 0 - 7500VAR
Resolution L 0.1VAR 1VAR
Accuracy (VA)² - (W)², Calculated value
Crest Factor Measurement Range 0.00 - 10.00
Resolution 0.01
Accuracy Ap / A

General Specifications

MODEL 8505 8512 8520 8530 8540 8560
GENERAL
PLC Remote Control Input:Output ON, Output OFF/Reset, Output Verify, Interlock, File Recall M1 through M7, Trigger Output: Fail, Test-in-Process
Rear Input AC Outlet Terminal Block
Memory Std. 10 x 100 (file x sequence) / MANUAL only 10 file no sequence 100 x 100 (file x sequence) / MANUAL, STEP, PULSE only 100 file no sequence
Sync Signal/ Ext Trigger Std. ON/OFF ON / START / END / BOTH / OFF / EVENT, Output Signal 5V, BNC type
Display 4.3" TFT LCD
Protection OCP, OVP, OPP, OTP, LVP, RCP and FAN.
Interface Standard USB, PLC remote, LAN, Analog / Option GPIB, RS-232
Efficiency (at Full load)11 ≥ 74% ≥ 81% ≥ 84% ≥ 83% ≥ 84% ≥ 84%
Response Time (Tr/Tf)12 275-400usec (Typical)
Electromagnetic compatibility (EMC) Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU EN 55011:2016/A1:2017 (Group 1, Class A), EN 61326-1:2013, EN 61326-2-1:2013, EN 61000-3-11:2000, EN 61000-3-12:2011
Safety Complies with the requirements of the following directive and standards. Low Voltage Directive 2014/30/EU, EN 61010-1
Op. / Non-Op. Temp. / Humidity13 0 to 40°C / -40 to 75°C / 20 to 80%RH
Dimension (W x H x D), mm 430 x 88 x 500 430 x 88 x 500 430 x 88 x 500 430 x 88 x 500 430 x 176 x 500 430 x 176 x 500
Weight 15KG 15KG 15KG 15KG 28KG 28KG

Standard Accessories

8505 8512 8520 8530 8540 8560
Interlock Disable Key (1505) x1 x1 x1 x1
USB Cable x1 x1 x1 x1
Shorting bar x1 x1 x1 x1
Power Cord (125Vac/10A) x1 x1 x1 x1

Specifications subject to change

400XAC Series 3 Phase AC Power Sources

With a unique feature set and competitive price point, the 400XAC Series provides 3Ø AC power in a single box. The exclusive SmartCONFIG feature allows switching from 1Ø to 3Ø or DC output with the push of a button. This maximizes investment while providing the AC power needed for applications. The 400XAC Series consists of two models: the 430XAC is a 3 kVA AC power source and the 460XAC is a 6 kVA AC power source.

Features

  • Exclusive SmartCONFIG feature allows for push button switch of 1Ø, 3Ø, or DC output.
  • Single phase input power requirements.
  • 50 built-in memory locations with 9 test steps.
  • Built-in power factor correction (PFC).
  • Advanced metering circuits monitor voltage, current, peak current, power, apparent power, reactive power, power factor, and crest factor.
  • External voltage sensing for accurate metering.
  • Transient feature simulates voltage variations, brownouts, and transient voltage conditions.
  • Programmable starting and ending angle of the output sine wave.
  • Rack mount handle kit included.

Image of an EEC 400XAC Series AC Power Source unit, showing its front panel controls and a wheeled base.

Applicable Industries

  • Aerospace
  • Appliance
  • Motor

EEC Benefits

  • 5 Year Warranty
  • 1 Day Guaranteed Shipment

Standard & Options

  • Standard: USB/RS-232 Interface, Ethernet Interface
  • Options: GPIB Interface

400XAC Series Specifications

Input

430XAC 460XAC
INPUT
Phase 1Ø or 3Ø
Voltage 200-240 VAC 1Ø: 200~240 VAC ± 10%
3Ø3W: 200~240 VAC ± 10%
3Ø4W: 346~416 VAC ± 10%
Frequency 47-63 Hz

AC Output

430XAC 460XAC
AC OUTPUT
Power Rating 1Ø2W: 3000 VA
1Ø3W: 3000 VA
3Ø4W: 3000 VA
1Ø2W: 6000 VA
1Ø3W: 6000 VA
3Ø4W: 6000 VA
Max. Current (RMS) 1Ø2W: 5-150 V: 9.2 A @ <110 V for per phase
5-300 V: 4.6 A @ ≤220 V for per phase
1Ø2W: 5-150 V: 18.4 A @ <110 V for per phase
5-300 V: 9.2 A @ ≤220 V for per phase
1Ø3W: 5-150 V: 9.2 A @ <110 V for per phase
5-300 V: 4.6 A @ ≤220 V for per phase
1Ø3W: 5-150 V: 18.4 A @ <110 V for per phase
5-300 V: 9.2 A @ ≤220 V for per phase
3Ø4W: 5-150 V: 9.2 A @ <110 V for per phase
5-300 V: 4.6 A @ ≤220 V for per phase
3Ø4W: 5-150 V: 18.4 A @ <110 V for per phase
5-300 V: 9.2 A @ ≤220 V for per phase
Inrush Current (peak) 110.4 A 220.8 A
55.2 A 110.4 A
36.8 A for per phase 73.6 A for per phase
18.4 A for per phase 36.8 A for per phase
36.8 A for per phase 73.6 A for per phase
18.4 A for per phase 36.8 A for per phase
THD (Total Harmonic Distortion) <0.5% (Resistive Load) at 40.0~70.0 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range.
±0.5% (Resistive Load) at 70.1~1000 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range.
Crest Factor ≥3 ≥3
Line Regulation ± 0.1 V ± 0.1 V
Load Regulation (Hardware) ± (1% of output +1 V) at Resistive Load, <400 µS response time ± (1% of output +1 V) at Resistive Load, <400 µS response time
Load Regulation (Software) ± 0.2 V, <1 S response time ± 0.2 V, <1 S response time
DC offset ≤ ± 5 mV ≤ ± 5 mV
Poly-phase mode (3Ø4W) for per phase output setting Voltage 5.0~300 VAC (phase), 8.6~520 VAC (line), 150/300 V Auto Range
Accuracy ± (0.2% of setting + 3 counts)
Frequency Range 40~1000 Hz Full Range Adjust
Accuracy ± 0.03% of setting
Starting & Ending Range Phase Angle 0~359°
Accuracy ±1°(45~65 HZ)
Current Hi Limit 5V~150 V 0.01~9.20 A 0.01~18.40 A
5V~300 V Accuracy 0.01~4.60 A 0.01~9.20 A
OC Fold Back Response Time ± (2.0% of setting + 2 counts) ± (2.0% of setting + 2 counts)
Ramp-Up Timer (second) Range <1.4 s <1.4 s
Accuracy 0.0~999.9 s 0.0~999.9 s
Ramp-Down Timer (second) Range ± (0.1% + 0.05 sec) ± (0.1% + 0.05 sec)
Accuracy 0.0~999.9 s 0.0~999.9 s
Delay Timer Range ± (0.1% + 0.1 sec) ± (0.1% + 0.1 sec)
Accuracy 1 s~999.9 s 1 s~999.9 s
Dwell Timer Range 0.1 m~999.9 min 0.1 m~999.9 min
Accuracy 0.1 h~999.9 h ± (0.1% + 0.1 sec) 0.1 h~999.9 h ± (0.1% + 0.1 sec)
0, 1s~999.9 h (0=continuous) 0, 1s~999.9 h (0=continuous)
Poly-phase mode (3Ø4W) for per phase measurement Frequency Range 0.0-1000 Hz 0.0-1000 Hz
Accuracy ± 0.1 Hz (501-1000 Hz Accuracy ±0.2 Hz) ± 0.1 Hz (501-1000 Hz Accuracy ±0.2 Hz)
Voltage Range 0.0-420.0 V 0.0-840.0V
Accuracy ± (0.2% of reading + 3 counts) L1 Voltage + L2 Voltage, Calculated and displayed to one significant digits
Current (RMS) Range L 0.005A~1.200A 0.005A~2.400A
Range H 1.00A~13.00A 2.00~26.00A
Calculated Formula L VA VA
Calculated Formula H ∑ VA ∑ VA
Power Range L 0.0W~360.0W 0.0W~720.0W
Range H 300W~3900W 600W~7800W
Accuracy L A Power + B Power + C Power, Calculated value A Power + B Power + C Power, Calculated value
Accuracy H √(VA)² - (W)², Calculated value √(VA)² - (W)², Calculated value
Power Factor Range 0 - 1.000 0 - 1.000
Resolution 0.001 0.001
Accuracy Calculated and displayed to three significant digits Calculated and displayed to three significant digits
Power Apparent (VA) Range L 0.0VA~360.0VA 0.0VA~720.0VA
Range H 300VA~3900VA 600VA~7800VA
Calculated Formula L √(W)² + ()² √(W)² + ()²
Calculated Formula H
Power Reactive (Q) Range L 0.0VAR~360.0VAR 0.0VAR~720.0VAR
Range H 300VAR~3900VAR 600VAR~7800VAR
Calculated Formula L A VAR + B VAR + C VAR, Calculated value A VAR + B VAR + C VAR, Calculated value
Calculated Formula H
Crest Factor Range 0-10.00 0-10.00
Accuracy Ap / A, Calculated and displayed to two significant digits Ap / A, Calculated and displayed to two significant digits

DC Output

430XAC 460XAC
DC OUTPUT
Max. Power 3000 W 6000 W
Max. Current 0-210 V: 14.4 A
0-420 V: 7.2 A
0-210 V: 28.8 A
0-420 V: 14.4 A
Ripple and Noise (RMS) Range: 5-210 V <700 mV Range: 5-420 V <1100 mV
Ripple and Noise (p-p) <4.0 Vp-p

DC Settings

430XAC 460XAC
DC SETTINGS
Voltage 5-210 V / 5-420 V Selectable 5-210 V / 5-420 V Selectable
Accuracy ± (0.2% of setting + 3 counts) ± (0.2% of setting + 3 counts)
Current Hi Limit 14.40 A 28.80 A
Accuracy 7.20 A 14.40 A
OC Fold Back Response Time <1.4 s <1.4 s

DC Measurement

430XAC 460XAC
DC MEASUREMENT
Voltage Range 0.0-420.0 V 0.0-420.0 V
Accuracy ± (0.2% of setting + 5 counts) ± (0.2% of setting + 5 counts)
Current Range 0.05 A~19.50 A 0.05 A~39.00 A
Accuracy ± (1% of reading +5 counts) ± (1% of reading +5 counts)
Power Range 0 W~3900 W 0 W~7800 W
Accuracy ± (2% of reading +5 counts) ± (2% of reading +5 counts)

Protection

430XAC 460XAC
PROTECTION
Software OCP Over Current 110% of full rated current >1 second Over Current 110% of full rated current >1 second
Output Short Shut Down Speed <1 second <1 second
Software OPP When over Power 105 ~ 110% of full power >5 second.
When over Power >110% of full power <1 second.
When over Power 105 ~ 110% of full power >5 second.
When over Power >110% of full power <1 second.
Software OTP Temperature over 95 degree C on the power amp and PFC heatsink Temperature over 120 degree C on the power amp and PFC heatsink
Software OVP L When output frequency < 100Hz, maximum voltage deviation + 5V
When output frequency 101-500Hz, maximum voltage deviation + 15V
When output frequency 501-1000Hz, maximum voltage deviation + 20V
When output frequency < 100Hz, maximum voltage deviation + 10V
When output frequency 101-500Hz, maximum voltage deviation + 30V
When output frequency 501-1000Hz, maximum voltage deviation + 40V
Software OVP H When output frequency < 100Hz, maximum voltage deviation + 10V
When output frequency 101-500Hz, maximum voltage deviation + 30V
When output frequency 501-1000Hz, maximum voltage deviation + 40V
When output frequency < 100Hz, maximum voltage deviation + 5V
When output frequency 101-500Hz, maximum voltage deviation + 15V
When output frequency 501-1000Hz, maximum voltage deviation + 20V
Software LVP L When output frequency < 100Hz, maximum voltage deviation -5V > 0.5 second
When output frequency 101-500Hz, maximum voltage deviation -15V > 0.5 second
When output frequency 501-1000Hz, maximum voltage deviation -20V > 0.5 second
When output frequency < 100Hz, maximum voltage deviation -10V > 0.5 second
When output frequency 101-500Hz, maximum voltage deviation -30V > 0.5 second
When output frequency 501-1000Hz, maximum voltage deviation -40V > 0.5 second
Software LVP H When output frequency < 100Hz, maximum voltage deviation -10V > 0.5 second
When output frequency 101-500Hz, maximum voltage deviation -30V > 0.5 second
When output frequency 501-1000Hz, maximum voltage deviation -40V > 0.5 second
When output frequency < 100Hz, maximum voltage deviation -5V > 0.5 second
When output frequency 101-500Hz, maximum voltage deviation -15V > 0.5 second
When output frequency 501-1000Hz, maximum voltage deviation -20V > 0.5 second
Reverse Current Protection (RCP) Over 75W

General

430XAC 460XAC
GENERAL
Transient (only for 40~70 Hz) Trans-Volt 0.0-300.0 V Resolution 0.1 V
Trans-Site 0°~359° Resolution 1°
Trans-Time 0.5-999.9 mS Resolution 0.1 mS
Trans-Cycle 0-9999, 0-Constant
Operation Key Feature Soft key, Numeric key, Rotary Knob
Remote Input Signal Test, Reset, Interlock, Recall program memory 1 through 7
Remote Output Signal Pass, Fail, Test-in Process
Key Lock Yes, Password Driven
Memory 50 memories, 9 steps/memory
Ext Trigger START / END / BOTH / OFF in the Program mode, Output Signal 5 V, BNC type
Alarm Volume Setting Range: 0-9 ; 0 = OFF, 1 is softest volume, 9 is loudest volume.
Graphic Display 240 x 64 dot resolution Monographic LCD / Contrast 9 Levels 1-9
PFC PF ≥0.97 at Full load
Efficiency ≥78% (at Full load)
Auto Loop cycle 0 = Continuous, OFF, 2~9999
Over Current Fold Back On/Off, Setting On when output current over setting Hi-A value it will fold back output voltage to keep constant output current is setting Hi-A value, Response time <1400ms
Safety Agency CE Listed
Dimensions (W x H x D) 430 x 400.5 x 500 mm
16.93 x 15.77 x 19.69 in
Net Weight 105.8 lbs (48 kg) 125.6 lbs (57 kg)
Operation Environment 0-40°C / 20-80% RH

Specifications subject to change

Contact Information

Headquarters

28105 N. Keith Drive
Lake Forest, IL 60045 USA

Telephone: +1-847-367-4077

Fax: +1-847-367-4080

Email: info@ikonixusa.com

Website: www.ikonixusa.com

Ikonix Taiwan

16F-2., No.237, Sec. 1, Datong Rd.,
Xizhi Dist., New Taipei City 221, Taiwan

Telephone: +886-2-21653066

Fax: +886-2-21653077

Email: contact@ikonixasia.com

Website: www.ikonixasia.com

Ikonix Asia

Unit D3-5-2 (2ND Floor) Block D3, Dana 1 Commercial Centre, Jalan PJU 1A/46,
47301 Petaling Jaya, Selangor, Malaysia

Telephone: +60-3-78429168

Fax: +60-3-78426168

Email: contact@ikonixasia.com

Website: www.ikonixasia.com

Local Sales Offices

EEC has local sales offices throughout the world. To find your nearest representative, visit us at eecsources.com.

Models: 8500 Series Power Source, 8500 Series, Power Source, Source

File Info : application/pdf, 19 Pages, 10.31MB

EEC Catalog HR 5

References

Adobe PDF Library 17.0 Adobe InDesign 19.0 (Windows)

Related Documents

Preview LabVIEW Programming Guide for EEC Power Sources
An example LabVIEW program demonstrating how to control EEC Power Sources, including setting parameters, initiating tests, and reading meter data using IVI ActiveX drivers.