EEC Power Sources
Powering Production.®
Manual • Automated • Programmable
April 2023 V1.1
Our Story
Since 1978 EEC has been providing AC Power Sources for the power conversion industry. Our commitment to quality, innovation, and customer service has helped set the expectation for the industry. In 2020 EEC introduced the 8500 Series Power Source, the world's highest power density single phase AC Source. As of 2021, EEC joined the Ikonix Family to become an Ikonix brand, where it continued to innovate and shape the power conversion industry.
A History of Innovation
1978: EEC is founded in Taipei City, Taiwan.
1979: Introduced the CFC Series AC power source and became the first AC power Source/Inverter professional manufacturer in Taiwan.
1988: Introduced the CFC-100W Series Digital AC power sources.
1991: The first Ikonix investment in EEC.
1994: EEC became the sole manufacturer of Battery Charges for the Taiwan military – General Headquarters of Combined Service Force. Collaboration with Associated Research, Inc. (An Ikonix Brand) to become an ODM partner.
2001: Expanded into Suzhou, China and Japan.
2002: Introduced the 6300/6400/6500 High Power Switch Mode Power Supplies.
2008: Moved the Taipei headquarters to a larger facility in Taipei Neihu Technology Park.
2009: Announced the 61000 Series Programmable Power Source.
2020: Introduced the 8500 Series Power Source – the world's highest power density single phase AC source.
2021: The final Ikonix purchase of all EEC shares. EEC joins the Ikonix family to become an Ikonix Brand.
Customer Happiness Promise
EEC aims to provide an amazing experience and quality testers that last a long time. If a customer is not satisfied with their power source, it can be returned within 45 days for a full refund. Annual calibration with EEC or an authorized partner extends the warranty an additional year for the service life of the power source, and at least five years after discontinuation. If the product breaks during that time, EEC promises to fix it for free (unless abuse or excessive damage is present). When a power source reaches the end of its service life, EEC will responsibly recycle it and offer a discount on a replacement.
[Annual calibration and inspection must be made in each successive year starting one year after the original purchase date in order to remain eligible for extended warranty coverage beyond the standard warranty period (five years).]
[5-star rating] CUSTOMER HAPPINESS
5 Year Warranty
Your new power source is warranted to be free from defects in workmanship and material for a period of (5) years from date of shipment.
**5 year warranty is valid on any model purchased in 2021 or after.
Ongoing Support
EEC works to provide the best service and support in the industry. With decades of industry experience, EEC is a trusted partner to help customers be compliant to NRTL standards. EEC works closely with customers to help them achieve their goals and has built a worldwide network of knowledgeable partners, ensuring coverage no matter where they are.
Call +1-847-367-4077
Product Reference Chart
| Model | Output Power Capability | Output Configurations | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 500 VA | 1.25 kVA | 2 kVA | 3 kVA | 4 kVA | 6 kVA | 1 Phase | Split 1 Phase (2 Lines/1 Neutral) | 3 Phase | |
| 430XAC | ✔️ | ✔️ | |||||||
| 460XAC | ✔️ | ✔️ | |||||||
| 8505 | ✔️ | ✔️ | |||||||
| 8512 | ✔️ | ✔️ | |||||||
| 8520 | ✔️ | ✔️ | |||||||
| 8530 | ✔️ | ✔️ | |||||||
| 8540 | ✔️ | ✔️ | |||||||
| 8560 | ✔️ | ✔️ | |||||||
| Model | Voltage Output Max | Frequency Output Range | Max A @ <110V/220V (per phase) | PC Control | CE Mark | Free GUI Available |
|---|---|---|---|---|---|---|
| 430XAC | 300/600/520* | 40-1000 | 9.2A/4.6A | ✔️ | ✔️ | ✔️ |
| 460XAC | 300/600/520* | 40-1000 | 18.4A/9.2A | ✔️ | ✔️ | ✔️ |
| 8505 | 310 | 5.0-1200 | 5.0A/2.5A | ✔️ | ✔️ | ✔️ |
| 8512 | 310 | 5.0-1200 | 12.5A/6.25A | ✔️ | ✔️ | ✔️ |
| 8520 | 310 | 5.0-1200 | 20A/10A | ✔️ | ✔️ | ✔️ |
| 8530 | 310 | 5.0-1200 | 30A/15A | ✔️ | ✔️ | ✔️ |
| 8540 | 310 | 5.0-1200 | 40A/20A | ✔️ | ✔️ | ✔️ |
| 8560 | 310 | 5.0-1200 | 60A/30A | ✔️ | ✔️ | ✔️ |
*x2 = the number of sources required to achieve an output rating. x3 = the number of sources required to achieve an output rating and 3 phase. 300/600/520* = 300V phase 1Ø, 600V split 1Ø, 520V 3Ø
8500 Series Programmable AC Power Source
The EEC 8500 Series is the most power dense and functionality rich power source in EEC's history, offering improved capability, functionality, and a reduced footprint. This series is manufactured for simulating common grid faults, voltage dips, and other power abnormalities. The 8500 Series provides an output voltage up to 310VAC and an output frequency ranging from 5 Hz – 1,200 Hz, making it a versatile solution for many applications. It features an enhanced interface designed with the end-user in mind. EEC 8500 Sources can be configured as a simple AC Power Source in MANUAL mode, as an upgraded option with Standard mode, or incorporating all functions with Advanced Mode. Advanced mode enables sweeps of voltage, frequencies, transients, and DC bias over a single sequence or multiple tests. The 8500 Series includes the following models: 8505, 8512, 8520, 8530, 8540, & 8560.
Features
- 14 pre-configured waveforms allow simulation of nearly any abnormal condition on the DUT by selecting the desired waveform.
- With expanded output voltage to 310VAC and output frequency from 5Hz to 1200Hz, the 8500 provides a single, simple solution for a wide variety of testing applications.
- Advanced mode option allows easy simulation of voltage surges, voltage drops, voltage pulses, voltage sweeps, DC bias, and frequency sweeps to meet specific testing application needs.
- High power density with a reduced overall footprint offers flexibility for benchtop or rack mount applications.
- Legacy Mode allows retention of command sets from 6000, 7000, or 300XAC series.
Image of the front panel of an EEC 8500 Series AC Power Source, displaying voltage, current, and frequency settings, along with control buttons and a rotary knob.
Applicable Industries
- Aerospace
- Appliance
- Laboratory
- Networking
- System Integrator
- LED Lighting
- Medical
EEC Benefits
- 5 Year Warranty
- 1 Day Guaranteed Shipment
Standard & Options
- Standard: USB/RS-232 Interface, Ethernet Interface
- Options: GPIB Interface
8500 Series Specifications
Modes
| INPUT | MANUAL MODE | STANDARD MODE | ADVANCED MODE |
|---|---|---|---|
| Manual Operation | ✔️ | ✔️ | ✔️ |
| PC Interface (USB/LAN standard, optional GPIB) | ✔️ | ✔️ | |
| PowerTRAC Compatibility | ✔️ | ✔️ | |
| Voltage, Frequency, Transient, and DC Bias Sweeps | ✔️ |
AC Output Specifications
| MODEL | 8505 | 8512 | 8520 | 8530 | 8540 | 8560 |
|---|---|---|---|---|---|---|
| AC OUTPUT | ||||||
| Phase | 1Ø | 1Ø | 1Ø | 1Ø | 1Ø | 1Ø |
| Power Rating | 500VA | 1250VA | 2kVA | 3kVA | 4kVA | 6kVA |
| Voltage Range | 0 - 310V, 155/310V Auto Range | |||||
| Resolution | 0.1V | |||||
| Accuracy2 | ±(0.2% of setting + 3counts) | ±(0.2% of setting + 6counts) | ||||
| Max. Current (r.m.s)1 | 5A | 12.5A | 20A | 30A | 40A | 60A |
| (0-155V) | 2.5A | 6.25A | 10A | 15A | 20A | 30A |
| (0-310V) | DC, 5 - 1200Hz Full Range Adjust | 0.1Hz at 0.0 - 999.9Hz , 1Hz at 1000 - 1200Hz | ||||
| Frequency Range | ±0.03% of setting(≥ 15Hz), ±0.3% of setting(<15Hz) | |||||
| Resolution | ± 0.3% @ 50/60Hz (Full Resistive Load) | |||||
| Accuracy2 | ≥ 3 | ≥ 3 | ≥ 3 | 2.5 | ≥ 3 | 2.5 |
| Total Harmonic Distortion (THD)3 | 4 | 4 | 4 | 3 | 4 | 3 |
| Crest Factor4 | ± 0.1V | |||||
| Inrush Current | ±0.2V,<1s response time | |||||
| Line Regulation | ||||||
| Load Regulation5 | ||||||
DC Output Specifications
| 8505 | 8512 | 8520 | 8530 | 8540 | 8560 | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| DC OUTPUT | |||||||||||
| Power rating | 300W | 750W | 1200W | 1800W | 2400W | 3600W | |||||
| Voltage Range | 0 - 420V, 210/420V Auto Range | ||||||||||
| Resolution | 0.1V | ||||||||||
| Accuracy2 | ±(0.2% of setting + 3counts) | ±(0.2% of setting + 6counts) | |||||||||
| Max. Current (r.m.s)2 | 3.0A | 7.5A | 12.0A | 18.0A | 24.0A | 36.0A | |||||
| (0-210V) | 1.5A | 3.75A | 6.0A | 9.0A | 12.0A | 18.0A | |||||
| (0-420V) | L | < 700mV | < 800mV | ||||||||
| Ripple and Noise (r.m.s)6 | H | < 700mV | < 800mV | ||||||||
| Ripple and Noise (p-p)6 | < 6.0Vp-p | < 7.0Vp-p | |||||||||
| Load Regulation5 | ±0.2V,<1s response time | ||||||||||
Settings & Measurements
Settings
| MODEL | 8505 | 8512 | 8520 | 8530 | 8540 | 8560 |
|---|---|---|---|---|---|---|
| SETTINGS | ||||||
| Start/End Angle | 0-359 | |||||
| Current Hi Limit (OC Fold=OFF) | 0.05-5.00A | 0.05-12.50A | 0.05-20.00A | 0.10-30.00A | 0.10-40.00A | 0.10-60.00A |
| (0-155V) | 0.05-2.50A | 0.05-6.25A | 0.05-10.00A | 0.10-15.00A | 0.10-20.00A | 0.10-30.00A |
| (0-310V) | 0.01A | |||||
| Resolution | ± (2.0% of setting + 4 counts) | |||||
| OC Fold Back Response Time7 | < 1.4s | |||||
| Time Range | 1.0 - 999.9h / 1.0 - 999.9m / 1.0 - 999.9s / 0.2 - 999.9ms | |||||
| Resolution | 0.1h/ 0.1m/ 0.1s/ 0.1ms | |||||
| Accuracy | ± (0.1% + 0.1 h) / ± (0.1% + 0.1 m) / ± (0.1% + 0.1 s) / ± (0.1% + 0.1 ms) | |||||
| Time unit | h, m, s, ms | |||||
| Ramp up Range | 0.1 - 999.9s, 0 = OFF | |||||
| Resolution | 0.1s | |||||
| Accuracy | ± (0.1% + 1 Cycle) at Output frequency ≤ 10Hz / ± (0.1% + 0.1 s) at Output frequency > 10Hz | |||||
Input Specifications
| Phase | Voltage | Max. Current | Frequency | Power Factor8 |
|---|---|---|---|---|
| 1Ø | 100 - 240 V ± 10% | 8A | 50 / 60 Hz | ≥ 0.93 |
| 1Ø | 200 - 240 V ± 10% | 18A | ||
| 1Ø or 3Ø | 1Ø: 200~240 VAC ± 10% 3Ø3W: 200~240 VAC ± 10% 3Ø4W: 346~416 VAC ± 10% |
30A | ||
| ≥ 0.97 | ||||
| 1Ø: 45A/3Ø3W: 38A 3Ø4W: 22A |
Measurement Specifications
| 8505 | 8512 | 8520 | 8530 | 8540 | 8560 | |
|---|---|---|---|---|---|---|
| MEASUREMENT | ||||||
| Voltage(AC) Range | 0 - 310V, 155/310V Auto Range | |||||
| Resolution | 0.1V | |||||
| Accuracy2 | ±(0.2% of reading + 3counts) at voltage > 5V | ±(0.2% of reading + 6counts) at voltage > 5V | ||||
| Voltage(DC) Range | 0 - 420V, 210/420V Auto Range | |||||
| Resolution | 0.1V | |||||
| Accuracy2 | ±(0.2% of reading + 3counts) at voltage > 5V | ±(0.2% of reading + 6counts) at voltage > 5V | ||||
| Current9 Range L | 0.050 - 1.200A | 0.050 - 5.000A | 0.050 - 20.00A | 0.10 - 37.50A | 0.10 - 50.00A | 0.10 - 75.00A |
| Resolution L | 1.00 - 6.25A | 4.00 - 15.62A | 4.00 - 25.00A | 0.10 - 15.00A | 0.10 - 20.00A | 0.10 - 30.00A |
| Resolution3 | 0.001A | 0.01A | ||||
| Accuracy2 L | ± (1% of reading + 10counts) at CF < 3 | ± (0.5% of reading +8counts) | ||||
| Accuracy2 H | ± (0.5% of reading +12counts) | |||||
| Frequency Range | 0.0 - 1200Hz | |||||
| Resolution | 0.1Hz / 1Hz | |||||
| Accuracy | ±0.1Hz @ 5 - 999.9Hz. / ±1Hz @ 1000 - 1200Hz | |||||
| Power10 (AC,DC) Range L | 0.0 - 75.0W | 0.0 - 300.0W | 240 - 2500W | 0 - 3750W | 0 - 5000W | 0 - 7500W |
| Range H | 60 - 625W | 240 - 1563W | 240 - 2500W | 0 - 3750W | 0 - 5000W | 0 - 7500W |
| Resolution L | 0.1W | 1W | ||||
| Accuracy2 L | ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V | ± (2% of reading +15 counts) at PF ≥ 0.35 and voltage > 5V | ||||
| Accuracy2 H | ± (1% of reading +5 counts) at PF ≥ 0.35 and voltage > 5V | ± (1% of reading +10 counts) at PF ≥ 0.35 and voltage > 5V | ||||
| Power Factor Range | 0.000 - 1.000 | |||||
| Resolution | 0.001 | |||||
| Accuracy | W/VA, Calculated and displayed to three significant digits | |||||
| Power Apparent (VA) Range L | 0.0 - 75.0VA | 0.0 - 300.0VA | 240 - 2500VA | 0 - 3750VA | 0 - 5000VA | 0 - 7500VA |
| Range H | 60 - 625VA | 240 - 1563VA | 240 - 2500VA | 0 - 3750VA | 0 - 5000VA | 0 - 7500VA |
| Resolution L | 0.1VA | 1VA | ||||
| Accuracy | V×A, Calculated value | |||||
| Peak Current Measurement Range L | 0.0 - 20.0Apk | 0.0 - 50.0Apk | 0.0 - 80.0Apk | 0.0 - 120.0Apk | 0.0 - 160.0Apk | 0.0 - 240.0Apk |
| Resolution | 0.1A | |||||
| Accuracy | ± (0.5% of reading +8counts) | ± (0.5% of reading +12counts) | ||||
| Reactive Power Measurement Range L | 0.0 - 75.0VAR | 0.0 - 300.0VAR | 240 - 2500VAR | 0 - 3750VAR | 0 - 5000VAR | 0 - 7500VAR |
| Range H | 60 - 625VAR | 240 - 1563VAR | 240 - 2500VAR | 0 - 3750VAR | 0 - 5000VAR | 0 - 7500VAR |
| Resolution L | 0.1VAR | 1VAR | ||||
| Accuracy | (VA)² - (W)², Calculated value | |||||
| Crest Factor Measurement Range | 0.00 - 10.00 | |||||
| Resolution | 0.01 | |||||
| Accuracy | Ap / A | |||||
General Specifications
| MODEL | 8505 | 8512 | 8520 | 8530 | 8540 | 8560 |
|---|---|---|---|---|---|---|
| GENERAL | ||||||
| PLC Remote Control | Input:Output ON, Output OFF/Reset, Output Verify, Interlock, File Recall M1 through M7, Trigger Output: Fail, Test-in-Process | |||||
| Rear Input | AC Outlet | Terminal Block | ||||
| Memory Std. | 10 x 100 (file x sequence) / MANUAL only 10 file no sequence | 100 x 100 (file x sequence) / MANUAL, STEP, PULSE only 100 file no sequence | ||||
| Sync Signal/ Ext Trigger Std. | ON/OFF | ON / START / END / BOTH / OFF / EVENT, Output Signal 5V, BNC type | ||||
| Display | 4.3" TFT LCD | |||||
| Protection | OCP, OVP, OPP, OTP, LVP, RCP and FAN. | |||||
| Interface Standard | USB, PLC remote, LAN, Analog / Option GPIB, RS-232 | |||||
| Efficiency (at Full load)11 | ≥ 74% | ≥ 81% | ≥ 84% | ≥ 83% | ≥ 84% | ≥ 84% |
| Response Time (Tr/Tf)12 | 275-400usec (Typical) | |||||
| Electromagnetic compatibility (EMC) | Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU EN 55011:2016/A1:2017 (Group 1, Class A), EN 61326-1:2013, EN 61326-2-1:2013, EN 61000-3-11:2000, EN 61000-3-12:2011 | |||||
| Safety | Complies with the requirements of the following directive and standards. Low Voltage Directive 2014/30/EU, EN 61010-1 | |||||
| Op. / Non-Op. Temp. / Humidity13 | 0 to 40°C / -40 to 75°C / 20 to 80%RH | |||||
| Dimension (W x H x D), mm | 430 x 88 x 500 | 430 x 88 x 500 | 430 x 88 x 500 | 430 x 88 x 500 | 430 x 176 x 500 | 430 x 176 x 500 |
| Weight | 15KG | 15KG | 15KG | 15KG | 28KG | 28KG |
Standard Accessories
| 8505 | 8512 | 8520 | 8530 | 8540 | 8560 | |
|---|---|---|---|---|---|---|
| Interlock Disable Key (1505) | x1 | x1 | x1 | x1 | ||
| USB Cable | x1 | x1 | x1 | x1 | ||
| Shorting bar | x1 | x1 | x1 | x1 | ||
| Power Cord (125Vac/10A) | x1 | x1 | x1 | x1 |
Specifications subject to change
400XAC Series 3 Phase AC Power Sources
With a unique feature set and competitive price point, the 400XAC Series provides 3Ø AC power in a single box. The exclusive SmartCONFIG feature allows switching from 1Ø to 3Ø or DC output with the push of a button. This maximizes investment while providing the AC power needed for applications. The 400XAC Series consists of two models: the 430XAC is a 3 kVA AC power source and the 460XAC is a 6 kVA AC power source.
Features
- Exclusive SmartCONFIG feature allows for push button switch of 1Ø, 3Ø, or DC output.
- Single phase input power requirements.
- 50 built-in memory locations with 9 test steps.
- Built-in power factor correction (PFC).
- Advanced metering circuits monitor voltage, current, peak current, power, apparent power, reactive power, power factor, and crest factor.
- External voltage sensing for accurate metering.
- Transient feature simulates voltage variations, brownouts, and transient voltage conditions.
- Programmable starting and ending angle of the output sine wave.
- Rack mount handle kit included.
Image of an EEC 400XAC Series AC Power Source unit, showing its front panel controls and a wheeled base.
Applicable Industries
- Aerospace
- Appliance
- Motor
EEC Benefits
- 5 Year Warranty
- 1 Day Guaranteed Shipment
Standard & Options
- Standard: USB/RS-232 Interface, Ethernet Interface
- Options: GPIB Interface
400XAC Series Specifications
Input
| 430XAC | 460XAC | |
|---|---|---|
| INPUT | ||
| Phase | 1Ø | 1Ø or 3Ø |
| Voltage | 200-240 VAC | 1Ø: 200~240 VAC ± 10% 3Ø3W: 200~240 VAC ± 10% 3Ø4W: 346~416 VAC ± 10% |
| Frequency | 47-63 Hz | |
AC Output
| 430XAC | 460XAC | |
|---|---|---|
| AC OUTPUT | ||
| Power Rating | 1Ø2W: 3000 VA 1Ø3W: 3000 VA 3Ø4W: 3000 VA |
1Ø2W: 6000 VA 1Ø3W: 6000 VA 3Ø4W: 6000 VA |
| Max. Current (RMS) | 1Ø2W: 5-150 V: 9.2 A @ <110 V for per phase 5-300 V: 4.6 A @ ≤220 V for per phase |
1Ø2W: 5-150 V: 18.4 A @ <110 V for per phase 5-300 V: 9.2 A @ ≤220 V for per phase |
| 1Ø3W: 5-150 V: 9.2 A @ <110 V for per phase 5-300 V: 4.6 A @ ≤220 V for per phase |
1Ø3W: 5-150 V: 18.4 A @ <110 V for per phase 5-300 V: 9.2 A @ ≤220 V for per phase |
|
| 3Ø4W: 5-150 V: 9.2 A @ <110 V for per phase 5-300 V: 4.6 A @ ≤220 V for per phase |
3Ø4W: 5-150 V: 18.4 A @ <110 V for per phase 5-300 V: 9.2 A @ ≤220 V for per phase |
|
| Inrush Current (peak) | 110.4 A | 220.8 A |
| 55.2 A | 110.4 A | |
| 36.8 A for per phase | 73.6 A for per phase | |
| 18.4 A for per phase | 36.8 A for per phase | |
| 36.8 A for per phase | 73.6 A for per phase | |
| 18.4 A for per phase | 36.8 A for per phase | |
| THD (Total Harmonic Distortion) | <0.5% (Resistive Load) at 40.0~70.0 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range. ±0.5% (Resistive Load) at 70.1~1000 Hz and output voltage within the 80~140 VAC at Low Range or the 160~280 VAC at High Range. |
|
| Crest Factor | ≥3 | ≥3 |
| Line Regulation | ± 0.1 V | ± 0.1 V |
| Load Regulation (Hardware) | ± (1% of output +1 V) at Resistive Load, <400 µS response time | ± (1% of output +1 V) at Resistive Load, <400 µS response time |
| Load Regulation (Software) | ± 0.2 V, <1 S response time | ± 0.2 V, <1 S response time |
| DC offset | ≤ ± 5 mV | ≤ ± 5 mV |
| Poly-phase mode (3Ø4W) for per phase output setting Voltage | 5.0~300 VAC (phase), 8.6~520 VAC (line), 150/300 V Auto Range | |
| Accuracy | ± (0.2% of setting + 3 counts) | |
| Frequency Range | 40~1000 Hz Full Range Adjust | |
| Accuracy | ± 0.03% of setting | |
| Starting & Ending Range Phase Angle | 0~359° | |
| Accuracy | ±1°(45~65 HZ) | |
| Current Hi Limit 5V~150 V | 0.01~9.20 A | 0.01~18.40 A |
| 5V~300 V Accuracy | 0.01~4.60 A | 0.01~9.20 A |
| OC Fold Back Response Time | ± (2.0% of setting + 2 counts) | ± (2.0% of setting + 2 counts) |
| Ramp-Up Timer (second) Range | <1.4 s | <1.4 s |
| Accuracy | 0.0~999.9 s | 0.0~999.9 s |
| Ramp-Down Timer (second) Range | ± (0.1% + 0.05 sec) | ± (0.1% + 0.05 sec) |
| Accuracy | 0.0~999.9 s | 0.0~999.9 s |
| Delay Timer Range | ± (0.1% + 0.1 sec) | ± (0.1% + 0.1 sec) |
| Accuracy | 1 s~999.9 s | 1 s~999.9 s |
| Dwell Timer Range | 0.1 m~999.9 min | 0.1 m~999.9 min |
| Accuracy | 0.1 h~999.9 h ± (0.1% + 0.1 sec) | 0.1 h~999.9 h ± (0.1% + 0.1 sec) |
| 0, 1s~999.9 h (0=continuous) | 0, 1s~999.9 h (0=continuous) | |
| Poly-phase mode (3Ø4W) for per phase measurement Frequency Range | 0.0-1000 Hz | 0.0-1000 Hz |
| Accuracy | ± 0.1 Hz (501-1000 Hz Accuracy ±0.2 Hz) | ± 0.1 Hz (501-1000 Hz Accuracy ±0.2 Hz) |
| Voltage Range | 0.0-420.0 V | 0.0-840.0V |
| Accuracy | ± (0.2% of reading + 3 counts) | L1 Voltage + L2 Voltage, Calculated and displayed to one significant digits |
| Current (RMS) Range L | 0.005A~1.200A | 0.005A~2.400A |
| Range H | 1.00A~13.00A | 2.00~26.00A |
| Calculated Formula L | VA | VA |
| Calculated Formula H | ∑ VA | ∑ VA |
| Power Range L | 0.0W~360.0W | 0.0W~720.0W |
| Range H | 300W~3900W | 600W~7800W |
| Accuracy L | A Power + B Power + C Power, Calculated value | A Power + B Power + C Power, Calculated value |
| Accuracy H | √(VA)² - (W)², Calculated value | √(VA)² - (W)², Calculated value |
| Power Factor Range | 0 - 1.000 | 0 - 1.000 |
| Resolution | 0.001 | 0.001 |
| Accuracy | Calculated and displayed to three significant digits | Calculated and displayed to three significant digits |
| Power Apparent (VA) Range L | 0.0VA~360.0VA | 0.0VA~720.0VA |
| Range H | 300VA~3900VA | 600VA~7800VA |
| Calculated Formula L | √(W)² + ()² | √(W)² + ()² |
| Calculated Formula H | ||
| Power Reactive (Q) Range L | 0.0VAR~360.0VAR | 0.0VAR~720.0VAR |
| Range H | 300VAR~3900VAR | 600VAR~7800VAR |
| Calculated Formula L | A VAR + B VAR + C VAR, Calculated value | A VAR + B VAR + C VAR, Calculated value |
| Calculated Formula H | ||
| Crest Factor Range | 0-10.00 | 0-10.00 |
| Accuracy | Ap / A, Calculated and displayed to two significant digits | Ap / A, Calculated and displayed to two significant digits |
DC Output
| 430XAC | 460XAC | |
|---|---|---|
| DC OUTPUT | ||
| Max. Power | 3000 W | 6000 W |
| Max. Current | 0-210 V: 14.4 A 0-420 V: 7.2 A |
0-210 V: 28.8 A 0-420 V: 14.4 A |
| Ripple and Noise (RMS) | Range: 5-210 V <700 mV | Range: 5-420 V <1100 mV |
| Ripple and Noise (p-p) | <4.0 Vp-p | |
DC Settings
| 430XAC | 460XAC | |
|---|---|---|
| DC SETTINGS | ||
| Voltage | 5-210 V / 5-420 V Selectable | 5-210 V / 5-420 V Selectable |
| Accuracy | ± (0.2% of setting + 3 counts) | ± (0.2% of setting + 3 counts) |
| Current Hi Limit | 14.40 A | 28.80 A |
| Accuracy | 7.20 A | 14.40 A |
| OC Fold Back Response Time | <1.4 s | <1.4 s |
DC Measurement
| 430XAC | 460XAC | |
|---|---|---|
| DC MEASUREMENT | ||
| Voltage Range | 0.0-420.0 V | 0.0-420.0 V |
| Accuracy | ± (0.2% of setting + 5 counts) | ± (0.2% of setting + 5 counts) |
| Current Range | 0.05 A~19.50 A | 0.05 A~39.00 A |
| Accuracy | ± (1% of reading +5 counts) | ± (1% of reading +5 counts) |
| Power Range | 0 W~3900 W | 0 W~7800 W |
| Accuracy | ± (2% of reading +5 counts) | ± (2% of reading +5 counts) |
Protection
| 430XAC | 460XAC | |
|---|---|---|
| PROTECTION | ||
| Software OCP | Over Current 110% of full rated current >1 second | Over Current 110% of full rated current >1 second |
| Output Short Shut Down Speed | <1 second | <1 second |
| Software OPP | When over Power 105 ~ 110% of full power >5 second. When over Power >110% of full power <1 second. |
When over Power 105 ~ 110% of full power >5 second. When over Power >110% of full power <1 second. |
| Software OTP | Temperature over 95 degree C on the power amp and PFC heatsink | Temperature over 120 degree C on the power amp and PFC heatsink |
| Software OVP L | When output frequency < 100Hz, maximum voltage deviation + 5V When output frequency 101-500Hz, maximum voltage deviation + 15V When output frequency 501-1000Hz, maximum voltage deviation + 20V |
When output frequency < 100Hz, maximum voltage deviation + 10V When output frequency 101-500Hz, maximum voltage deviation + 30V When output frequency 501-1000Hz, maximum voltage deviation + 40V |
| Software OVP H | When output frequency < 100Hz, maximum voltage deviation + 10V When output frequency 101-500Hz, maximum voltage deviation + 30V When output frequency 501-1000Hz, maximum voltage deviation + 40V |
When output frequency < 100Hz, maximum voltage deviation + 5V When output frequency 101-500Hz, maximum voltage deviation + 15V When output frequency 501-1000Hz, maximum voltage deviation + 20V |
| Software LVP L | When output frequency < 100Hz, maximum voltage deviation -5V > 0.5 second When output frequency 101-500Hz, maximum voltage deviation -15V > 0.5 second When output frequency 501-1000Hz, maximum voltage deviation -20V > 0.5 second |
When output frequency < 100Hz, maximum voltage deviation -10V > 0.5 second When output frequency 101-500Hz, maximum voltage deviation -30V > 0.5 second When output frequency 501-1000Hz, maximum voltage deviation -40V > 0.5 second |
| Software LVP H | When output frequency < 100Hz, maximum voltage deviation -10V > 0.5 second When output frequency 101-500Hz, maximum voltage deviation -30V > 0.5 second When output frequency 501-1000Hz, maximum voltage deviation -40V > 0.5 second |
When output frequency < 100Hz, maximum voltage deviation -5V > 0.5 second When output frequency 101-500Hz, maximum voltage deviation -15V > 0.5 second When output frequency 501-1000Hz, maximum voltage deviation -20V > 0.5 second |
| Reverse Current Protection (RCP) | Over 75W | |
General
| 430XAC | 460XAC | |
|---|---|---|
| GENERAL | ||
| Transient (only for 40~70 Hz) | Trans-Volt 0.0-300.0 V Resolution 0.1 V Trans-Site 0°~359° Resolution 1° Trans-Time 0.5-999.9 mS Resolution 0.1 mS Trans-Cycle 0-9999, 0-Constant |
|
| Operation Key Feature | Soft key, Numeric key, Rotary Knob | |
| Remote Input Signal | Test, Reset, Interlock, Recall program memory 1 through 7 | |
| Remote Output Signal | Pass, Fail, Test-in Process | |
| Key Lock | Yes, Password Driven | |
| Memory | 50 memories, 9 steps/memory | |
| Ext Trigger | START / END / BOTH / OFF in the Program mode, Output Signal 5 V, BNC type | |
| Alarm Volume Setting | Range: 0-9 ; 0 = OFF, 1 is softest volume, 9 is loudest volume. | |
| Graphic Display | 240 x 64 dot resolution Monographic LCD / Contrast 9 Levels 1-9 | |
| PFC | PF ≥0.97 at Full load | |
| Efficiency | ≥78% (at Full load) | |
| Auto Loop cycle | 0 = Continuous, OFF, 2~9999 | |
| Over Current Fold Back | On/Off, Setting On when output current over setting Hi-A value it will fold back output voltage to keep constant output current is setting Hi-A value, Response time <1400ms | |
| Safety Agency | CE Listed | |
| Dimensions (W x H x D) | 430 x 400.5 x 500 mm 16.93 x 15.77 x 19.69 in |
|
| Net Weight | 105.8 lbs (48 kg) | 125.6 lbs (57 kg) |
| Operation Environment | 0-40°C / 20-80% RH | |
Specifications subject to change
Contact Information
Headquarters
28105 N. Keith Drive
Lake Forest, IL 60045 USA
Telephone: +1-847-367-4077
Fax: +1-847-367-4080
Email: info@ikonixusa.com
Website: www.ikonixusa.com
Ikonix Taiwan
16F-2., No.237, Sec. 1, Datong Rd.,
Xizhi Dist., New Taipei City 221, Taiwan
Telephone: +886-2-21653066
Fax: +886-2-21653077
Email: contact@ikonixasia.com
Website: www.ikonixasia.com
Ikonix Asia
Unit D3-5-2 (2ND Floor) Block D3, Dana 1 Commercial Centre, Jalan PJU 1A/46,
47301 Petaling Jaya, Selangor, Malaysia
Telephone: +60-3-78429168
Fax: +60-3-78426168
Email: contact@ikonixasia.com
Website: www.ikonixasia.com
Local Sales Offices
EEC has local sales offices throughout the world. To find your nearest representative, visit us at eecsources.com.