UNI-T UT261A Phase Sequence Indicator
Operating Manual
Symbols
The following indication symbols are used on UT261A or in this Manual:
- A: Electric shocking
- A: Warning
- ~: Dangerous voltage
- [dual-insulation]: Dual or mandatory insulation protection
- [ground]: Grounding
- [AC/DC]: AC or DC
- CE: Comply with EU code
- CAT III: Comply with IEC61010-1 pollution protection degree 2, means the degree of pulse withstand voltage protection measure provided by the instrument; OVERVOLTAGE CATEGORY III refers to the stationary device (for instance, electric meter and major over-current protection devices).
Safety Instructions
▲ Attention: It refers to the circumstances or behaviors possibly making UT261A damaged.
▲ Warning: It refers to the circumstances or behaviors endangering the user.
To avoid electric shocks or fires, please follow the regulations below:
- Before using or repairing the product, please read the safety instructions below carefully.
- Please follow the local and national safety codes.
- Do wear personal protective equipment to avoid electric shocks and other injuries.
- Do use the product with the method described by the manufacturer, otherwise the safety characteristics or protective actions provided by it will possibly be damaged.
- Check whether the insulators of the test leads are damaged or have any exposed metal. Inspect the continuity of the test leads. If any test lead is damaged, do replace it.
- Pay special attention if the voltage is a true RMS of 30VAC, or 42VAC as peak, or 60VDC because these voltages are likely to cause electric shocks.
- When a probe is used, put fingers away from its contact and behind its finger protecting device.
- The impedance generated by the transient current of the extra operating circuit connected in parallel will possibly affect the measurement adversely.
- Before measuring a dangerous voltage, such as a true RMS of 30VAC, or 42VAC as peak, or 60VDC because, make sure the product is operating normally.
- Do not use UT261A after any part of it has been dismantled.
- Do not use UT261A close to explosive gases, steam, or dust.
- Do not use UT261A in a humid place.
Description of a complete UT261A
The lights and jacks are described in Fig. 1:
Fig. 1:
[L1/A], [L2/B], [L3/C]: L1, L2 and L3 LCD
[②]: LCD for clockwise rotating
[③]: LCD for anti-clockwise rotating
[④]: LCD
[⑤]: Test lead
There is safety information on back of the product.
Measurement of direction of the rotating magnetic field
It is necessary to measure direction of the rotating magnetic field in the way below:
- Insert terminals L1, L2 and L3 of the test pen into the L1, L2 and L3 holes of UT261A, respectively.
- Insert the other terminal of the test pen into the alligator clip.
- Have the alligator clip accessed to the phases of the three power cables to be measured. After that, the LCDs of the product will automatically display the phase sequences of L1, L2 and L3.
Specification
Environment
- Working temperature: 0°C~40°C (32°F ~ 104°F)
- Storage temperature: 0℃~50℃ (32°F ~ 122°F)
- Elevation: 2000m
- Humidity: <95%
- Pollution protection grade: 2
- IP grade: IP 40
Mechanical specification
- Dimensions: 123mm×71mm×29mm (4.8in×2.8in×1.1in)
- Weight: 160g
Safety specification
- Electrical safety: Be in compliance with safety standards IEC61010/EN61010 and IEC 61557-7
- Maximum operating voltage (Ume): 700V
- CAT grade: CAT III 600V
Electrical specification
- Power supply: Provided by the measured device
- Nominal voltage: 40VAC-700VAC
- Frequency (fn): 15Hz-400Hz
- Current induction: 1mA
- Nominal test current (subject to each phase): 1mA
Maintenance
Attention
To avoid damage of UT261A:
- Only qualified technicians can repair or maintain UT261A.
- Make sure the calibration steps and performance test are proper and refer to proper maintenance information.
Attention
To avoid damage of UT261A:
- Do not use corrosives or solvents because they may damage the shell of UT261A.
- Before cleaning UT261A, pull out the test leads.
Accessories
Following standard parts are provided:
- A host machine
- An operating manual
- Three testing leads
- Three alligator clips
- A certificate of quality
- A bag
UNI-T
UNI-TREND TECHNOLOGY (CHINA) CO., LTD.
No6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone, Dongguan City, Guangdong Province, China
Tel: (86-769) 8572 3888
http://www.uni-trend.com