User Guide for SVL models including: V2-L RF CCT Dual Color LED Controller, V2-L RF CCT, Dual Color LED Controller, Color LED Controller, LED Controller, Controller

未命名 -1

SVL.UA

V2-L RF CCT - svl.ua

V2-L Page 1 2023.7 Mechanical Structures and Installations User Manual Ver 2.0.1 Technical Parameters RF CCT Match Remote Control (two match ways)

Пульт RS2 CCT від SkyDance. ✓ Ціна від 1 584,60 грн.

PDF preview unavailable. Download the PDF instead.

V2-L-1
V2-L
Dual Color LED Controller
 4096 levels 0-100% dimming smoothly without any flash.  Match with all RF 2.4G single zone or multiple zone dual color or remote control.  One RF controller accept up to 10 remote control.  Auto-transmitting function: Controller automatically transmit signal to
another controller with 30m control distance.  Synchronize on multiple number of controllers.  Fade in and out effect selectable.  3 levels color temperature (WW, NW and CW) selectable by
continuous power off and on operation.  Connect with external push switch to achieve on/off and 0-100% dimming function.  Over-load / Short circuit protection, recover automatically.
LVD RED
Technical Parameters

RF CCT
2 Channel / Step-less dimming/Wireless remote control/ Auto-transmitting/Synchronize/Push Dim/Multiple protection

Input and Output Input voltage Input current Output voltage Output current Output power Output type

12-48VDC 16.5A 2x(12-48)VDC 2CH,8A/CH 2x(96-384)W Constant voltage

Warranty Warranty

5 years

Dimming data Input signal Control distance Dimming gray scale Dimming range Dimming curve PWM frequency Package Size Gross weight

RF 2.4GHz + Push Dim 30m(Barrier-free space) 4096 (2^12) levels 0 -100% Linear 2KHz (default)
L178 x W50 x H38mm 0.126kg

Safety and EMC
EMC standard (EMC)
Safety standard(LVD) Radio Equipment(RED) Certi cation Environment Operation temperature Case temperature (Max.) IP rating

ETSI EN 301 489-1 V2.2.3 ETSI EN 301 489-17 V3.2.4 EN 62368-1:2020+A11:2020 ETSI EN 300 328 V2.2.2 CE,EMC,LVD,RED
Ta: -30 OC ~ +55OC Tc: +85OC IP20

Mechanical Structures and Installations

Push switch Push switch common
+
Installation rack LED indicator Match key
Match Remote Control (two match ways)

MATCH
-

IN PUT 12-48VDC

Cool white LED LED output + Warm white LED LED output +
Installation rack Power input Power input +

45mm

175mm 160mm 27mm

End user can choose the suitable match/delete ways. Two options are offered for selection:

Use the controller's Match key
Match: Short press match key, immediately press on/off key (single zone remote) or zone key (multiple zone remote) of the remote. The LED indicator fast flash a few times means match is successful.

Use Power Restart
Match: Switch off the power, then switch on power, repeat again. Immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 3 times on the remote. The light blinks 3 times means match is successful.

Delete: Press and hold match key for 5s to delete all match, The LED indicator fast flash a few times means all matched remotes were deleted.

Delete: Switch off the power, then switch on power, repeat again. Immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 5 times on the remote. The light blinks 5 times means all matched remotes were deleted.

User Manual Ver 2.0.1 2023.7

Page 1

Wiring Diagram
Push Switch

CW

2

OUTPUT

+

+

WW

1

+

-

MAT CH
+

IN PUT 12-48VDC

Wire Preparation:
1. The wiring can be solid or stranded with a cross-sectional area of 0.5 to 2 mm². Conventional 1mm² can withstand 10A output current.
2. When wiring is installed, the terminals must be tightened. If they are not tightened, the contact point resistance will be too high and the terminals will easily burn due to heat when used at full load for a long time.

+
-

CW WW

Dual color LED strip

Power Supply 12-48VDC Constant Voltage
0.5-2.0mm²
4-5mm

AC100-240V

CCT Remote

Note: 1. Continuously switch off and on the power supply two times rapidly, it will change WW, NW and CW 3 levels color temperature in sequence (factory setting). 2. Long press the match key for 15s to cancel the continuous switch off-on to switch 3 levels color temperature function.
Long press the match key for 10s to restore the factory setting. 3. The output power of a constant voltage power supply should be at least 1.2 times that of the output load (light strip),
otherwise the full power output of the load can easily cause automatic flickering or shaking of the light.
Light on/off fade time

Long press match key 5s, then short press match key 3 times, the lighting effect will be set to the fade in and fade out in 3s, the indicator light of LED controller blinks 3 times.
Long press match key 10s, restore factory default parameter, the light on/off time restores to 0.5s.

Push Dim

Click Long press(>1s) from OFF Long press(>1s) from ON
Dual color control

ON/OFF Color temperature UP/DOWN (turn off and turn on to return dimming)
Dimming UP/DOWN

The provided Push-Dim interface allows for a simple dimming method using commercially available non-latching(momentary) wall switchs. If more than one controller are connected to the same push switch, do a long press for more than 10s, then the system is synchronized and all lights in the group dim up to 100%. This means there is no need for any additional synchrony wire in larger installations. We recommend the number of controllers connected to a push switch does not exceed 25 pieces, The maximum length of the wires from push to controller should be no more than 20 meters.

WW=Warm white LED CW=Cool white LED Each channel can supply up to 192W(@24V) and white balance can be controlled as such:

Color temperature Power distribution

Cool white WW=0W,CW=192W

Neutral white WW=96W,CW=96W

Warm white WW=192W,CW=0W

Linear dual color tuning
Warm white(Min. 2700K) Neutral white(4000K)
Cool white(Max. 6500K)
Recommended CCT range

PPW WMM dduuttyy((%%))

Dimming curve

110000 9900 8800 7700 6600 5500 4400 3300 2200 1100

Gamma=1.0

10 20 30 40 50 60 70 80 90 100
Brightness(%)

InstallationPrecautions

1. The products shall not be stacked, the distance should be  20cm, so as not to affect lifespan of the products due to poor heat dissipation. 2. The product shall not be installed close to the switching power supply with an interval of  20cm to avoid radiation interference of the switching power supply. 3. The installation height shall be  1m from the oor to avoid shortening the remote control distance due to too weak reception signal. 4. The products are not allowed to be close to or covered by metal objects, with an interval of  20cm to avoid signal attenuation and shorten the remotedistance. 5. Avoid installation at the corner of the wall or the corner of the beam, with an interval of  20cm to avoid signal interference.

User Manual Ver 2.0.1 2023.7

Page 2


Corel PDF Engine Version 16.1.0.843 CorelDRAW X6