Instruction Manual for Shelly Qubino models including: B4523 Wave Plug UK, B4523, Wave Plug UK, Plug UK, UK

Wave Plug UK

10 janv. 2024 — failure of following the user and safety instructions in this guide. ... smartphone, tablet, PC, or home automation system. They work on Z-Wave™ wireless ...

kb.shelly.cloud

Download Manual

Shelly Qubino Wave Plug UK | Shelly Store UK | Smart Home Automation

PDF preview unavailable. Download the PDF instead.

Wave Plug UK EN v3
Wave Plug UK
C
A
B
D EN LEGEND A: Plug B: S button C: Socket D: LED indication ring (LED)

USER AND SAFETY GUIDE
Z-WaveTM smart plug with power measurement
READ BEFORE USE
This document contains important technical and safety information about the Device, its safe use and installation. CAUTION! Before beginning the installation, please read carefully and entirely this guide and any other documents accompanying the Device. Failure to follow the installation procedures could lead to malfunction, danger to your health and life, violation of law or refusal of legal and/or commercial guarantee (if any). Shelly Europe Ltd. is not responsible for any loss or damage in case of incorrect installation or improper operation of this Device due to failure of following the user and safety instructions in this guide.
TERMINOLOGY AND ABBREVIATIONS Device - In this document, the term "Device" is used to refer to the Shelly Qubino device that is a subject of this guide. Gateway (GW) - A Z-WaveTM gateway, also referred to as a Z-WaveTM controller, Z-WaveTM main controller, Z-WaveTM primary controller, or Z-WaveTM hub, etc., is a device that serves as a central hub for a Z-WaveTM smart home network. The term "gateway" is used in this document. S button - The Z-WaveTM Service button, located on Z-WaveTM devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.
ABOUT SHELLY QUBINO Shelly Qubino is a line of innovative microprocessor-managed devices, which allow remote control of electric circuits with a smartphone, tablet, PC, or home automation system. They work on Z-WaveTM wireless communication protocol, using a gateway. When the gateway is connected to the internet, you can control Shelly Qubino devices remotely from anywhere. Shelly Qubino devices can be operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Devices are designed to work with older generations of Z-WaveTM devices and gateways.
ABOUT THE DEVICE The Device is a smart plug/outlet with power measurement and overheating protection, which allows remote control of electric appliances with a mobile phone, tablet, PC, or home automation system.

B4523

V 0.0.3

ISTALLATION INSTRUCTIONS The Device can be plugged into standard BS 1363 (Type-G) sockets and accepts standard BS 1363 (Type-G) plugs. CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it. CAUTION! Do not connect the Device to appliances exceeding the given max. load! CAUTION! Do not install the Device where it can get wet. CAUTION! Do not use the Device if it has been damaged! CAUTION! Do not attempt to service or repair the Device yourself! CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury. CAUTION! Do not allow children to play with the device, especially with the S button. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children. CAUTION! The product is intended for indoor use only. CAUTION! Protect the product from dirt and moisture! Do not use the product in a damp environment! CAUTION! Do not plug Devices into each other!
Plug the Device into a power socket without an appliance/load connected to it. Then plug the appliance/load into the Device socket. To turn on the appliance/load, briefly press the S button. The LED will turn green if the load is 0 W, yellow if the load is between 0 W and 85% of the max. load, and red if the load is more than 85% of the max. load.
Z-WAVETM ADDING / REMOVING / FACTORY RESET Note! All Device outputs (O, O1, O2, etc. - depending on the Device type) will turn the load 1s on/1s off /1s on/1s off if the Device is successfully added to/removed from a Z-WaveTM network. Note! In case of Security 2 (S2) adding (inclusion), a dialog will appear asking you to enter the corresponding PIN Code (5 underlined digits) that are written on the Z-WaveTM DSK label on the side of the Device and on the Z-WaveTM DSK label inserted in the packaging. IMPORTANT: The PIN Code must not be lost.
Adding the Device to a Z-WaveTM network (inclusion)
SmartStart adding (inclusion)
SmartStart enabled products can be added into a Z-WaveTM network by scanning the Z-WaveTM QR Code present on the Device with a gateway providing SmartStart inclusion. No further action is required, and the SmartStart device will be added automatically within 10 minutes of being switched on in the network vicinity.
1. With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list in the gateway. 2. Plug the Device into a power socket. 3. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-WaveTM network. 4. Adding will be initiated automatically within a few seconds after plugging the Device into a power socket, and the Device will be added to a Z-WaveTM network automatically. 5. The blue LED will be blinking in Mode 2 during the adding process. 6. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-WaveTM network.
Adding (inclusion) with the S button
1. Plug the Device into a power socket. 2. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-WaveTM network. 3. Enable add/remove mode on the gateway. 4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode*. 6. The blue LED will be blinking in Mode 2 during the adding process. 7. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-WaveTM network. *Learn mode - a state that allows the Device to receive network information from the gateway.
Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.
Removing the Device from a Z-WaveTM network (exclusion) Note! The Device will be removed from your Z-WaveTM network, but any custom configuration parameters will not be erased.
Removing (exclusion) with the S button
1. Plug the Device into a power socket. 2. Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-WaveTM network. 3. Enable add/remove mode on the gateway. 4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode. 6. The blue LED will be blinking in Mode 2 during the removing process. 7. The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-WaveTM network.
Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.

Factory reset After Factory reset, all custom parameters and stored values (kWh, associations, routings, etc.) will return to their default state. HOME ID and NODE ID assigned to the Device will be deleted. Use this reset procedure only when the gateway is missing or otherwise inoperable.
Factory reset with the S button
Note! Factory reset with the S button is possible anytime.
1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 2. Press the S button multiple times until the LED turns solid red. 3. Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset. 4. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s. 5. The blue LED will be blinking in Mode 1 if the Factory reset is successful.
Note! For more information about this Device refer to the Extended User Guide available at: https://kb.shelly.cloud/

LED SIGNALIZATION

Mode 1 Mode 2 Mode 3 Mode 4
Mode 5

LED blinking modes 0,5s On/2s Off 0,5s On/0,5s Off 0,1s On/0,1s Off (1x to 7x - 0,2s On/0,2s Off) + 2s Off 0,2s On blue/0,2s On red

Normal mode

Colour

LED mode

Excluded/Removed

Blue

Mode 1

Included/Added

Green

Mode 1

Load 0 W

Green

Load between 0 W and 85% of Yellow the max. load

Load > 85% of the max. load

Red

Solid Solid Solid

Setting mode (with S button)

Adding/Removing (Inclusion/ Blue Exclusion) menu selected

Solid

Adding/Removing (Inclusion/ Blue Exclusion) menu - while pressing S button - Adding/ Removing (Inclusion/Exclusion) process selected

Mode 3

Factory reset menu selected Red

Solid

Factory reset - while pressing Red S button - Factory reset process selected

Mode 3

"Setting in progress" mode

Factory reset and reboot

Blue/Red/Green **

Adding/Removing (Inclusion/ Blue Exclusion)

Mode 2

Checking power supply 230 V AC frequency or 24 V DC voltage

Blue/Red

Mode 5

OTA Firmware updating

Blue/Red

Mode 2

Alarm mode

Overcurrent detected O

Red

Mode 4 (1x)

Overheat detected

Red

Mode 4

(2x)

Power supply fault (power

Red

supply 230 V AC frequency or

24 V DC voltage fault)

Mode 4 (3x)

Overvoltage detected

Red

Mode 4 (7x)

** LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.

TECHNICAL SPECIFICATIONS:

Power supply Power consumption Power measurement (W) Max. switching voltage AC Max. switching current AC Overheating protection Overcurrent protection Overvoltage protection Distance Z-Wave repeater: CPU Z-Wave frequency band Maximum radio frequency power transmitted in frequency bend(s) Size (H x W x D)
Weight Compatible sockets Compatible plugs Shell material Color Ambient temperature
Humidity Max. altitude

230 V ±10%, 50/60 Hz < 0,7 W Yes 260 V 13 A Yes Yes Yes up to 40 m indoors (131 ft.) Yes Z-Wave S800 868,4 MHz < 25 mW
60x60x56 ±0.5 mm / 2.36x2.36x2.20 ±0.02 in 74 ±1 g / 2.6 ±0.04 oz BS 1363 (Type-G) BS 1363 (Type-G) Plastic White -20°C to 40°C / -5°F to 105°F 30% to 70% RH 2000 m / 6562 ft.

IMPORTANT DISCLAIMER
Z-WaveTM wireless communication may not always be 100% reliable. This Device should not be used in situations in which life and/or valuables are solely dependent on its functioning. If the Device is not recognized by your gateway or appears incorrectly, you may need to change the Device type manually and ensure that your gateway supports Z-Wave PlusTM multi-channel devices.
CLEANING
CAUTION! Before cleaning the Device power off the connected appliance by pressing the S button, unplug it and then unplug the Device itself. Never clean the Device if it is connected to the mains! CAUTION! Use a wet soft cloth to clean the Device. CAUTION! Do not use aggressive detergents! CAUTION! Do not immerse the Device or wash it under running water!
DISPOSAL AND RECYCLING
This refers to the waste of electrical and electronic equipment. It is applicable in the EU, UK, US and other countries to collect waste separately. This symbol on the product or in the accompanying literature indicates that the product should not be disposed of in the daily waste. Wave Plug UK must be recycled to avoid possible damage to the environment or human health from uncontrolled waste disposal and to promote the reuse of materials and resources. It is your responsibility to dispose of the device separately from general household waste when it is already unusable.
ORDERING CODE: QNPL-001X12UK
DECLARATION OF CONFORMITY
Hereby, Shelly Europe Ltd. (former Allterco Robotics EOOD) declares that the radio equipment type Wave Plug UK is in compliance with Directive 2014/53/ EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: https://shelly.link/WavePlugUK-DoC
MANUFACTURER:
Shelly Europe Ltd. Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria Tel.: +359 2 988 7435 E-mail: zwave-shelly@shelly.cloud Support: https://support.shelly.cloud/ Web: https://www.shelly.com Changes in the contact data are published by the Manufacturer at the official website: https://www.shelly.com

1/1


Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)