Instruction Manual for JUNG models including: 429 D1 ST Room Controller Display Module, 429 D1 ST, Room Controller Display Module, Controller Display Module, Display Module

Raumcontroller-Modul

KNX, 429 D1 ST

Albrecht Jung GmbH & Co. KG

Manual en 429D1ST 32408603 20231108 (1 MB)

KNX F40 romkontroller 3-kanal NY! - Instell

Operating instructions


File Info : application/pdf, 12 Pages, 1.29MB

PDF preview unavailable. Download the PDF instead.

Manual en 429D1ST 32408603 20231108
Operating instructions
Room controller display module Art. no. 429 D1 ST

ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY
Telefon: +49 2355 806-0 Telefax: +49 2355 806-204 kundencenter@jung.de www.jung.de

Product image non-binding
08.11.2023 32408603 j0082408603

Room controller display module
Table of contents
1 Safety instructions ............................................................................................................ 3 2 Device components .......................................................................................................... 3 3 System information ........................................................................................................... 3 4 Intended use ..................................................................................................................... 4 5 Product characteristics ..................................................................................................... 4 6 Operation .......................................................................................................................... 4 7 Information for electrically skilled persons ........................................................................ 6
7.1 Mounting and electrical connection........................................................................ 6 7.2 Commissioning ...................................................................................................... 9
7.2.1 Safe-state mode ...................................................................................... 10 7.2.2 Master reset ............................................................................................ 10 8 Flashing frequencies of the LEDs................................................................................... 11 9 Technical data ................................................................................................................ 11 10 Accessories .................................................................................................................... 12 11 Warranty ......................................................................................................................... 12

32408603 j0082408603

2 / 12

08.11.2023

Room controller display module
1 Safety instructions
Electrical devices may be mounted and connected only by electrically skilled persons. Serious injuries, fire or property damage are possible. Please read and follow the manual fully. Use only the enclosed plastic screws for fastening to the supporting frame! Otherwise safe operation cannot be ensured. Electrostatic discharges can cause defects in the device. This manual is an integral part of the product, and must remain with the customer.
2 Device components

Figure 1

(1)

LCD with push-button operation

(2)

Buttons 1 and 2

(3)

Operating and status LED

3 System information
This device is a product of the KNX system and complies with the KNX directives. Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding.
The function of this device depends upon the software. Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer´s product database.
The device can be updated. Firmware can be easily updated with the Jung ETS Service App (additional software).

32408603 j0082408603

3 / 12

08.11.2023

Room controller display module
The device is KNX Data Secure capable. KNX Data Secure offers protection against manipulation in building automation and can be configured in the ETS project. Detailed technical knowledge is required. A device certificate, which is attached to the device, is required for safe commissioning. During mounting, the device certificate must be removed from the device and stored securely.
Planning, installation and commissioning of the device are carried out with the aid of the ETS, version 5.7.7 and higher or 6.1.0.
4 Intended use
­ Operation of loads, e.g. light on/off, dimming, blinds up/down, brightness values, temperatures, calling up and saving light scenes, etc.
­ Measurement and feedback control of the room temperature ­ Mounting in appliance box according to DIN 49073
5 Product characteristics
All buttons can be assigned with push-button sensor functions or functions for controller operation.
­ Four red status LEDs ­ A blue operation LED as an orientation light and to indicate the programming
status ­ Integrated bus coupling unit ­ Completion with set of buttons (see accessory) ­ Connection of push-button sensor extension module for expansion up to four
additional buttons ­ Integrated room temperature sensor ­ Room temperature control with setpoint value specification ­ Indication of room or setpoint temperature ­ Indication of outdoor temperature ­ with external sensor, e.g. weather station ­ Indication of time, in conjunction with KNX time encoder ­ The push-button sensor functions switching, dimming, controlling blinds, value
transmitter, calling up moods, etc. ­ Button function or rockers function, vertical or horizontal
6 Operation
Operating a function or load
Depending on the programming, a button can have up to three functions assigned to it ­ upper/left, lower/right, entire surface. Operation depends on the specific function.
 Switch: Short press on button.

32408603 j0082408603

4 / 12

08.11.2023

Room controller display module
 Dim: Long press on button. The dimming process ends when the button is released.
 Move Venetian blind: Long press on button.  Stop or adjust Venetian blind: Short press on button.  Call up light scene: Short press on button.  Save light scene: Long press on button.  Set value, e.g. brightness or temperature setpoint: Short press on button.
Operating modes and indication icons
The device compares the current room temperature with the setpoint temperature and controls heating or cooling devices according to the current demand. The setpoint temperature depends on the current operating mode and can be changed by the user, depending on the programming. The operating modes and the current controller status are shown in the display.
­ ó: Operating mode Comfort ­ ô: Operating mode Standby ­ õ: Operating mode Night ­ ö: Operating mode Frost/heat protection
The ö icon flashes if the room temperature drops below 5 °C / 41 °F. ­ ÷: Dewpoint operation indication; controller blocked ­ óõ: Comfort extension, night ­ óö: Comfort extension, frost protection ­ ìí...ê: Fan controller with fan level indication. ë= Fan off. ­ µ: Manual fan control ­ ÝÞ...â: Heating mode with heating stage indication ­ ãä...è: Cooling mode with cooling step indication ­ ¹: Indoor temperature ­ ¶¹: Outdoor temperature ­ ·¸: Setpoint temperature ­ ...--0 or 0--...: Setpoint temperature reduced or increased manually
When switched on, the display shows, next to the icon for the current operating mode, either:
­ the current time: the seconds mark flashes. ­ the current room temperature: icon ¹ ­ the current outdoor temperature: icon ¶¹ ­ the current setpoint temperature: icon ·¸
The display switches the information over automatically or at the press of a button, depending on the programming.

32408603 j0082408603

5 / 12

08.11.2023

Room controller display module
Second operating level
In the second operating level the following settings are available in sequence. Some items are not visible, depending on the programming of the device.
­ Presence mode ­ Setpoint shift ­ Basic temperature for Comfort mode ­ Lowering for standby mode, heating ­ Raising for standby mode, cooling ­ Lowering for night mode, heating ­ Raising for night mode, cooling ­ Changing the operating mode ­ Fan controller ­ Time indication ­ Current room temperature indication ­ Current temperature setpoint indication ­ Current outdoor temperature indication ­ Display contrast ­ Display illumination ­ OK ­ Exit and save settings ­ ESC ­ Exit without saving settings
Operating second operating level
The second operating level is programmed and not disabled.
 Open: Simultaneously press the buttons 1 and 2 at the top left (see figure 1).  Press button 1 at top or bottom.
The current setting is switched or the displayed value is increased or decreased.  Press button 2 at top or bottom. The display switches to the previous or next menu entry.
7 Information for electrically skilled persons
7.1 Mounting and electrical connection
DANGER!
Electric shock when live parts are touched. Electric shocks can be fatal. Cover up live parts in the installation environment.

32408603 j0082408603

6 / 12

08.11.2023

Room controller display module
Snapping on the adapter frame The adapter frame is required depending on the switch design range.
 With the adapter frame (7) in the correct orientation, snap it from the front onto the module (8) (see figure 2). Note marking TOP =.
Mounting and connecting the device

Figure 2: Mounting the controller module

(5)

Supporting frame

(6)

Design frame

(7)

Adapter frame

(8)

Controller module

(9)

Fastening screws

(10) Design control surfaces

(11) KNX device connection terminal

(12) Box screws

Supporting frame side A for A design ranges, CD design ranges and FD design. Supporting frame side B for LS design ranges.

Recommended installation height: 1.50 m.

When the push-button sensor extension module is used (see figure 3): preferably mounted vertically. Use large supporting frame (13). When mounting on only one appliance box, countersink the lower screws into the wall, e.g. with a ø 6 x10 mm hole. Use supporting frame as template.

32408603 j0082408603

7 / 12

08.11.2023

Room controller display module
DANGER!
When mounting with 230 V devices under a common cover, e.g. socket outlets, there is a danger of electrical shocks in the event of a fault! Electric shocks can be fatal. Do not install any 230 V devices in combination with a push-button sensor extension module under a common cover!
 Mount supporting frame (5) or (13) in the correct position onto an appliance box. Note marking TOP = at top; marking A or B in front. Use only the enclosed box screws (12).
 Push frame (6) onto supporting frame.  Mount the push-button sensor extension module (14) preferably below. Route
connecting cable (16) between supporting frame and intermediate web.  Push-button sensor extension module: Insert connecting cable (16) in the cor-
rect orientation into slot (15) in the controller module. Do not crimp the connecting cable (see figure 3).  Connect controller module (8) to the KNX using KNX device connection terminal (11) and push onto the supporting frame.  Fasten controller module (8) and push-button sensor extension module (12) to supporting frame using the enclosed plastic screws (8). Tighten the plastic screws only lightly.  Before mounting the control surfaces (10), load the physical address into the device (see chapter 5.2. commissioning).

Figure 3: Mounting with push-button sensor extension module
(13) Supporting frame for mounting with push-button sensor extension module (14) Extension module push-button sensor

32408603 j0082408603

8 / 12

08.11.2023

Room controller display module
(15) Slot for push-button sensor extension module (16) Push-button sensor extension module connecting cable
7.2 Commissioning
Preconditions in secure operation ­ Secure commissioning is activated in the ETS. ­ Device certificate entered/scanned or added to the ETS project. A high resolution camera should be used to scan the QR code. ­ Document all passwords and keep them safe.
Programming the physical address and application software Project design and commissioning with ETS version 5.7.7 and higher or 6.1.0.
The device is connected and ready for operation. The buttons are not mounted yet.
If the device does not receive any application software, or the wrong application software, then the blue operation LED flashes slowly.

Figure 4: Activating programming mode
 Activate programming mode: Press and hold push-button (17) (see figure 4). Then press push-button (18). The operation LED (19) flashes quickly.
 Programming the physical address. The operation LED (19) returns to its previous state ­ off, on, or flashing slowly.
 Programming the application program.
The operation LED flashes slowly (approx. 0.75 Hz) while the application program is programmed.

32408603 j0082408603

9 / 12

08.11.2023

Room controller display module
Fitting the control surfaces
The buttons (10) are available as a complete set of buttons. Individual buttons can be replaced using buttons with icons.
The physical address is loaded into the device.
 Place the buttons (10) on the device in the correct orientation and snap in with a short push. Note marking TOP =.
7.2.1 Safe-state mode
The safe-state mode stops the execution of the loaded application program.
If the device does not work properly - for instance as a result of errors in the project design or during commissioning - the execution of the loaded application program can be halted by activating the safe-state mode. The device remains passive in safestate mode, since the application program is not being executed (state of execution: terminated).
Only the system software of the device is still functional. ETS diagnosis functions and programming of the device are possible.
Activating safe-state mode
 Switch off the bus voltage.  Press and hold down the top left and bottom right button .  Switch on the bus voltage.
The safe-state mode is activated. The operation LED flashes slowly (approx. 1 Hz).
Do not release the buttons until the operation LED flashes.
Deactivating safe-state mode
 Switch off the voltage or carry out ETS programming.
7.2.2 Master reset
The master reset restores the basic device settings (physical address 15.15.255, firmware remains in place). The device must then be recommissioned with the ETS.
In secure operation: A master reset deactivates device security. The device can then be recommissioned with the device certificate.
If the device - for instance as a result of errors in the project design or during commissioning - does not work properly, the loaded application program can be deleted from the device by performing a master reset. The master reset resets the device to delivery state. Afterwards, the device can be put into operation again by programming the physical address and application program.

32408603 j0082408603

10 / 12

08.11.2023

Room controller display module
Performing a master reset
Precondition: The safe-state mode is activated.  Press and hold down the push-button (20) . Then press the push-button (21) for longer than 5 seconds until the operation LED flashes quickly (approx. 4 Hz).  Release the buttons.
The device performs a master reset.
The device restarts. The operation LED flashes slowly.
Resetting the device to its default settings
Devices can be reset to factory settings with the ETS Service App. This function uses the firmware contained in the device that was active at the time of delivery (delivered state). Restoring the factory settings causes the devices to lose their physical address and configuration.

8 Flashing frequencies of the LEDs

State of operation Application discharged
Safe-state mode Flashing status Alarm signal Master reset Programming mode Full-surface operation

Operation LED Approx. 0.75 Hz
Approx. 1 Hz Approx. 2 Hz Approx. 2 Hz Approx. 4 Hz Approx. 8 Hz ---

Status LED With On button pressed --Approx. 2 Hz Approx. 2 Hz ----Approx. 8 Hz

9 Technical data
KNX medium Safety Commissioning mode Rated voltage KNX Current consumption KNX
Without extension module With extension module Connection mode KNX Connecting cable KNX Protection class

TP256 KNX Data Secure (X-mode)
S mode DC 21 ... 32 V SELV
9 ... 12 mA 12 ... 15 mA Device connection terminal EIB-Y (St)Y 2x2x0.8
III

32408603 j0082408603

11 / 12

08.11.2023

Room controller display module
Measuring range Ambient temperature Storage/transport temperature

-5 ... +45°C -5 ... +45°C -25 ... +70°C

10 Accessories
Cover kit for Room controller module Push-button extension module, 1-gang Push-button extension module, 2-gang Push-button extension module, 3-gang Push-button extension module, 4-gang Cover kit 1-gang Cover kit 2-gang Cover kit 3-gang Cover kit 4-gang

Art. no.: ..4093 TSA.. Art. no.: 4091 TSEM Art. no.: 4092 TSEM Art. no.: 4093 TSEM Art. no.: 4094 TSEM Art. no.: ..401 TSA.. Art. no.: ..402 TSA.. Art. no.: ..403 TSA.. Art. no.: ..404 TSA..

11 Warranty
The warranty is provided by the specialist trade in accordance with statutory requirements.

ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY
Telefon: +49 2355 806-0 Telefax: +49 2355 806-204 kundencenter@jung.de www.jung.de

32408603 j0082408603

12 / 12

08.11.2023



References

ST4 PDF Engine (Build 12.0.4.0)