Polaris Diagnostic Test Kit

for Polaris Robotic Cleaners

WARNING

The Diagnostic Box and included test cables are to be used solely for diagnosing Polaris Robotic Cleaners. It must not be used for any other purpose. Diagnostic tests must be performed while the unit is out of the water. Failure to comply with the following warnings can result in property damage, personal injury, or death.

FOR YOUR SAFETY - This product must be serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty.

Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death.

Only connect unit to receptacle protected by a ground fault circuit interrupter (GFCI). Such a GFCI receptacle should be provided by a qualified installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this product. Disconnect the cleaner and have the problem corrected by a qualified service representative before using.

KEEP OUT OF REACH OF CHILDREN

Overview

P825

91 SERIES

93 94 95 SERIES

WARNING

WARNING

SAVE THESE INSTRUCTIONS

1.0 Overview

This document provides diagnostic testing instructions for the following Polaris robotic cleaners:

These instructions must be followed exactly. Not following the written procedure or taking shortcuts may increase the risk of personal injury. Read all instructions completely before starting the procedure.

1.1 Diagnostic Kit Components

The diagnostic test kit is supplied with four (4) test cables and a cord organizer, which can be mounted:

NOTE: All test cables are also available for order as individual replacement parts from your Polaris supplier.

1.2 Optional Test Cable for 91 Series Cleaners

Contact your dealer or www.polarispool.com for optional test cable for 91 Series cleaners. Ask for part number: R0704900.

(Image of Optional RED Test Cable P/N R0704900 with diagram of 4 Prongs Male to 4 Prongs Female connectors)

NOTE: To test the motor block for 91 SERIES cleaners, you will also need to use a spare power cord. 91 SERIES cleaners can only be tested for cleaner errors using the Diagnostic Box with the RED test cable.

1.3 Required for Testing

The consumer must provide the following items to perform the diagnostic testing:

1.4 Testing Strategy

The Diagnostic Box should be used to test for errors or malfunctions in the following cleaner components in this order:

  1. Control Box
  2. Cleaner and Floating Cable
  3. Motor Block

NOTE: Steps for connecting the cleaner and testing each component are different for each robotic cleaner series. For complete step by step procedures, refer to the specific cleaner section in this manual.

CAUTION

Do not touch the cleaner or any Diagnostic Box buttons while the test is running.

1.5 Diagnostic Box Display Panel

(Diagram of the Diagnostic Box display panel showing Testing Progress Bar, Testing Status Message, Select Control Box Test, Select Cleaner Test, Start Selected Test, EBOX, CLEANER, OK, CANCEL, START/STOP buttons, and 'diag box' logo)

1.6 Control Box Diagnostic Test Status and Diagnostic Messages

Connect the correct test cable between the Diagnostic Box and the cleaner Control Box. On the Diagnostic Box, press [EBOX] button, then press [START] button.

Control Box Quick Test Progress Bar Message During Test Diagnostic Message Action Required
auto testing test fail-At check connections and run test again (replace Diagnostic Box if second fail)
power supply test ▶▶ test fail replace Control Box
keyboard test ▶▶▶ test fail replace Control Box
test complete ▶▶▶▶▶ end good perform cleaner diagnostic test

1.7 Cleaner / Motor Block Diagnostic Tests Status and Diagnostic Messages

Set the cleaner on its back with wheels unobstructed. Connect the correct cable between the Diagnostic Box and the cleaner. On the Diagnostic Box, press [CLEANER] button, then press [START] button.

Control Box Quick Test Progress Bar Message During Test Diagnostic Message Action Required
system check test SC check connections and run test again
auto testing test fail-At check connections and run test again (replace Diagnostic Box if second fail)
communication ▶▶ test fail-Com check connections and run test again (if second fail, disassemble cleaner and test the motor block and the Floating Cable)
traction motor ▶▶▶ tfd1 traction forward drive 1
tfd2 traction forward drive 2
tbd1 traction backward drive 1
tbd2 traction backward drive 2
fail-trac replace with functioning motor block and retest
pump motor ▶▶▶▶▶ Pon pump on
Poff pump off
fail-trac replace with functioning motor block and retest
test complete ▶▶▶▶▶ end end replace with functioning motor block and retest

2.0 Test for 93 94 95 Series

2.1 Perform Control Box Test

  1. Plug the consumer's Control Box into a GFCI protected outlet.
  2. Plug the Diagnostic Box into a GFCI protected outlet.
  3. Connect one end of the GREEN test cable to the cleaner Control Box.
  4. Connect the other end of the GREEN test cable to the Diagnostic Box.

(Image showing Diagnostic Box and Control Box connected with GREEN cable)

  1. On the Diagnostic Box, press [EBOX] button then Start/Stop button to begin the test. The Diagnostic Box displays the test status and progress message (see Section 1.6).
  2. The propeller motor will turn on for approximately three to five (3-5) seconds.
  3. If the test completes and the Diagnostic Box displays the message: good, the cleaner Control Box is fully functional. Turn off the power to the Control Box and disconnect.
  4. If there is an error message on the Diagnostic Box display, see Section 2.4 Control Box Diagnostic Test for explanation and action. Replace the Control Box and repeat the test.

2.2 Perform Cleaner Test

  1. Set the cleaner head on a block of wood or some object that allows the cleaner wheels to rotate freely.
  2. Make sure the Diagnostic Box is plugged into a GFCI protected outlet.
  3. Connect the Floating Cable from the cleaner directly into the Diagnostic Box.
  4. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test.
  5. The drive motor starts and the Diagnostic Box displays test progress (see Section 1.7). The wheels should turn during this part of the test.
  6. The pump motor will turn on and off. The Diagnostic Box displays the test status and progress message (see Section 1.7).
  7. If the cycle completes and the Diagnostic Box displays the message: End, the floating cable and cleaner pass the test and are fully functional.
  8. If there is an error message on the Diagnostic Box display, see Section 2.5 Control Box Test for explanation and action.

2.3 Perform Test for Defective Motor Block

  1. Unplug the cleaner.
  2. Open the cleaner top and remove the filter canister. Remove the screw securing the propeller guard and remove propeller guard.
  3. Remove the propeller and the flow director by pushing out toward rear of cleaner housing.

(Image showing removal of propeller guard)

(Image showing removal of propeller and flow director)

  1. Close the cover, turn cleaner over and place on a soft surface so that it is resting on its top.
  2. Remove four (4) screws from the bottom of the cleaner. Remove the bottom plate/motor block.

NOTE: When removing the motor block, ensure the drive gears and drive pins are on the drive shafts.

  1. Disconnect the Floating Cable from the motor block by removing two (2) screws connecting the cable to the block. Pull the plug away from the block to remove.

NOTE: You will have one of the following motor block cable plugs:

(Image showing Integral Seal Plug)

(Image showing O-Ring Plug)

2.4 93 94 95 Series Control Box Test

(Flowchart detailing the Control Box test procedure for 93 94 95 Series)

2.5 93 94 95 Series Cleaner Test

(Flowchart detailing the Cleaner test procedure for 93 94 95 Series)

2.6 93 94 95 Series Motor Block Test

(Flowchart detailing the Motor Block test procedure for 93 94 95 Series)

3.0 Test for P825 Cleaner

3.1 Perform Control Box Test

  1. Plug the consumer's Control Box into a GFCI protected outlet.
  2. Plug the Diagnostic Box into a GFCI protected outlet.
  3. Connect the colored end of the BLUE test cable to the Diagnostic Box.
  4. Connect the other end of the BLUE test cable to the cleaner Control Box.

(Image showing Diagnostic Box and Control Box connected with BLUE cable)

  1. On the Diagnostic Box, press [EBOX] button then Start/Stop button to begin the test.
  2. If the cycle completes and the Diagnostic Box displays the message: good, the cleaner Control Box is fully functional. Turn off the power to the Control Box and disconnect.
  3. If there is an error message on the Diagnostic Box display, see Section 3.4 Control Box Test for explanation. Replace the Control Box and repeat the test.

3.2 Perform Cleaner Test

  1. Set the cleaner head on a block of wood or some object that allows the cleaner tracks to rotate freely.
  2. Make sure the Diagnostic Box is plugged into a GFCI protected outlet.
  3. Connect the colored end of the GREY test cable to the Diagnostic Box.
  4. Connect the other end of the GREY test cable to the Floating Cable from the cleaner.

(Image showing connection of GREY cable to Floating Cable)

  1. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test.
  2. The drive motor will start and the Diagnostic Box displays the test progress. The tracks should be moving during this part of the test.
  3. The pump motor will turn on and off and the Diagnostic Box displays the test progress.
  4. If the cycle completes and the Diagnostic Box displays the message: End, the floating cable and cleaner pass the test and are fully functional.
  5. If there is an error message on the Diagnostic Box display, see Section 3.5 Cleaner Test for explanation and action.

3.3 Perform Test for Defective Motor Block

  1. Unplug the cleaner.
  2. Remove the filter canister. Unscrew the impeller housing and remove impeller.
  3. Remove four (4) screws inside the canister at the handle brackets.
  4. Remove four (4) screws from the bottom of the canister bowl.

(Image showing removal of filter canister and impeller)

(Image showing removal of screws at handle brackets)

(Image showing removal of screws from bottom of canister bowl)

  1. Pry wheel keys from each side of the brush and remove the brush.
  2. Remove two (2) screws on each side of the cleaner body and remove body housings.

(Image showing removal of brush)

(Image showing removal of body housings)

  1. Turn the cleaner over, remove two (2) screws and take off the bottom plate.
  2. Turn the cleaner back over and gently pull the gear box off the handle mount. Repeat both sides and remove the gear box and the handle together.

(Image showing removal of bottom plate)

(Image showing removal of gear box and handle)

  1. Remove the canister bowl to free the motor block.
  2. Remove screws and detach the Floating Cable.

(Image showing removal of canister bowl)

(Image showing detachment of Floating Cable)

  1. Connect one end of the BROWN test cable into the motor block.
  2. Connect one end of the BROWN test cable into the motor block.
  3. Connect the other end of the BROWN test cable into the Diagnostic Box.
  4. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test. The drive gears will rotate on the drive shaft for approximately ten (10) seconds then stop. The Diagnostic Box displays the test status and progress message (see Section 1.7).
  5. If the cycle completes and the Diagnostic Box displays the message: End, the Motor Block is functional and the Floating Cable should be replaced.

3.4 P825 Control Box Test

(Flowchart detailing the Control Box test procedure for P825)

3.5 P825 Cleaner Test

(Flowchart detailing the Cleaner test procedure for P825)

3.6 P825 Motor Block Test

(Flowchart detailing the Motor Block test procedure for P825)

4.0 Test for 9100 / P91 Cleaner

4.1 Perform Cleaner Test

NOTE: You can only test the cleaner function on the 9100 and P91 with the Diagnostic Box. You cannot test the Control Box functionality.

  1. Set the cleaner head on a block of wood or another solid object that allows the cleaner wheels to rotate freely.
  2. Plug the Diagnostic Box into a GFCI protected outlet.
  3. Connect the colored end of the RED test cable into the Diagnostic Box.

NOTE: The RED cable does not come standard with the Diagnostic Box but is available for separate order (part number: R0704900).

  1. Connect the other end of the RED test cable to the Floating Cable from the cleaner.
  2. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test.
  3. Drive motors should start within a few seconds. Cleaner wheels will rotate for several seconds and stop automatically when the test is completed.
  4. While wheels are moving, check for air flowing from the exhaust on the back of the cleaner.

(Image showing hand connecting RED cable to Floating Cable)

  1. If the cycle completes and the Diagnostic Box displays the message: End, the cleaner is fully functional.
  2. If the wheels do not rotate or there is an error message on the Diagnostic Box display, see Section 4.3 Cleaner Test for explanation and action.

4.2 Perform Test for Defective Motor Block or Floating Cable

NOTE: To test the motor block for 91 SERIES cleaners, you will also need a spare Floating Cable.

  1. Determine if there is water damage to the O-ring or the cable receptacle. Remove four (4) screws from the handle on the cleaner. Remove the handle piece.

(Image showing removal of handle piece)

  1. Remove three (3) screws from cable receptacle (see Figure 6). Remove the Floating Cable and receptacle.
  2. Check inside the receptacle for water damage.
  3. Perform a complete visual inspection of the length of the entire Floating Cable for wear.
  4. Check the power plug for any visible wear or water damage.

(Image showing check of O-ring for damage)

(Image showing Floating Cable and receptacle)

  1. Check the O-ring for damage.
  2. If there is no evidence of water damage to the O-ring, the cable receptacle, or the Floating Cable and power plug, the motor block is defective. Replace with a new motor block and repeat the test.

NOTE: Return defective component(s) to Polaris. (For more information, go to www.Polarispool.com.)

4.3 91 Series Cleaner Test

(Flowchart detailing the Cleaner test procedure for 91 Series)

NOTE: The 9100 and P91 Control Box cannot be tested using the Diagnostic Box.

NOTES

PDF preview unavailable. Download the PDF instead.

148341 201652394726 Adobe PDF Library 11.0 Adobe InDesign CC 2014 (Macintosh)

Related Documents

Preview Polaris 360 Factory Rebuild Kit: Assembly and Warranty Guide
Comprehensive guide for the Polaris 360 Factory Rebuild Kit, detailing disassembly, assembly steps, in-line back-up valve replacement, and limited warranty information for the Polaris automatic swimming pool cleaner.
Preview Polaris FREEDOM™ Cordless Robotic Cleaner Owner's Manual
Comprehensive owner's manual for the Polaris FREEDOM™ Cordless Robotic Cleaner, covering setup, operation, maintenance, and troubleshooting.
Preview Polaris Freedom Cordless Robotic Cleaner Quick Start Guide
A concise guide to setting up and operating the Polaris Freedom Cordless Robotic Cleaner, including charging, cleaning modes, and app integration.
Preview Polaris PIXEL Compact Cordless Robotic Cleaner Owner's Manual
Comprehensive owner's manual for the Polaris PIXEL Compact Cordless Robotic Cleaner (Model ET37). Includes setup, operation, maintenance, troubleshooting, and safety instructions for optimal pool cleaning.
Preview Polaris PIXEL Compact Cordless Robotic Pool Cleaner Owner's Manual
Comprehensive owner's manual for the Polaris PIXEL Compact Cordless Robotic Pool Cleaner. Includes setup, operation, maintenance, safety guidelines, and troubleshooting for efficient pool cleaning.
Preview Polaris™ Edge 2/0 AWG Series Installation Guide
Detailed installation instructions for the NSI Industries Polaris™ Edge 2/0 AWG Series connectors, covering conductor preparation, splicing, and torque specifications for reliable electrical connections.
Preview Polaris 2022 Geared For Good ESG Report
Polaris' 2022 ESG report detailing their commitment to environmental, social, and governance initiatives under the 'Geared For Good' framework. Learn about their progress in product design, production, community impact, and employee well-being.
Preview Polaris 360 Quick Disconnect Replacement Instructions
Step-by-step guide for replacing the quick disconnect on a Polaris 360 pool cleaner, detailing component removal and reassembly for optimal pool maintenance.