Owner's Manual for MEAN WELL models including: MSP-200 Series 200W Single Output Medical Type, MSP-200 Series, 200W Single Output Medical Type, Single Output Medical Type, Output Medical Type, Medical Type, Type

MSP-200-20241030

wangj

MSP-200 series

30 ott 2024 — MSP-200-3.3 MSP-200-5. MSP-200-7.5. MSP-200-12. MSP-200-15. MSP-200-24. MSP-200-36. MSP-200-48. MODEL. DC VOLTAGE. RATED CURRENT. CURRENT RANGE. RATED POWER.

[PDF] MSP-200 series

Oct 30, 2024 · The maximum line drop compensation is 0.5V. 200W Single Output Medical Type. MSP-200 series.


File Info : application/pdf, 3 Pages, 110.91KB

PDF preview unavailable. Download the PDF instead.

MSP-200-SPEC
200W Single Output Medical Type

MSP-200 series

 Features :

User's Manual

Universal AC input / Full range

Built-in active PFC function, PF>0.95

High efficiency up to 89%

Withstand 300VAC surge input for 5 seconds

Protections: Short circuit / Overload / Over voltage / Over temperature

Cooling by free air convection

Built-in constant current limiting circuit

1U low profile 38mm

Medical safety approved (MOOP level)

Built-in remote ON-OFF control

Standby 5V@0.3A

 GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Built-in remote sense function No load power consumption<0.5W (Note.6) 5 years warranty

SPECIFICATION

ANSI/AAMI ES60601-1 IEC60601-1 TPTC004

MODEL

MSP-200-3.3 MSP-200-5 MSP-200-7.5 MSP-200-12 MSP-200-15 MSP-200-24 MSP-200-36 MSP-200-48

DC VOLTAGE

3.3V

5V

7.5V

12V

15V

24V

36V

48V

OUTPUT

RATED CURRENT

40A

35A

CURRENT RANGE

0 ~ 40A

0 ~ 35A

RATED POWER

132W

175W

RIPPLE & NOISE (max.) Note.2 80mVp-p

90mVp-p

VOLTAGE ADJ. RANGE

2.8 ~ 3.8V 4.3 ~ 5.8V

VOLTAGE TOLERANCE Note.3 ±2.0%

±2.0%

LINE REGULATION

±0.5%

±0.5%

LOAD REGULATION

±1.5%

±1.0%

SETUP, RISE TIME

1000ms, 50ms/230VAC

26.7A

16.7A

13.4A

0 ~ 26.7A

0 ~ 16.7A

0 ~ 13.4A

200.3W

200.4W

201W

100mVp-p 120mVp-p 150mVp-p

6.8 ~ 9V

10.2 ~ 13.8V 13.5 ~ 18V

±2.0%

±1.0%

±1.0%

±0.5%

±0.3%

±0.3%

±1.0%

±0.5%

±0.5%

2500ms, 50ms/115VAC at full load

8.4A 0 ~ 8.4A 201.6W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5%

5.7A 0 ~ 5.7A 205.2W 250mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5%

4.3A 0 ~ 4.3A 206.4W 250mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5%

HOLD UP TIME (Typ.)

16ms/230VAC 16ms/115VAC at full load

VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.95/230VAC PF>0.99/115VAC at full load

INPUT EFFICIENCY (Typ.)

80%

84%

86%

88%

88%

88%

89%

89%

AC CURRENT (Typ.)

2.2A/115VAC 1.1A/230VAC

INRUSH CURRENT (Typ.) 35A/115VAC 70A/230VAC

LEAKAGE CURRENT Note.7 Earth leakage current < 300A/264VAC , Touch leakage current < 100A/264VAC

OVERLOAD PROTECTION
OVER VOLTAGE

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

3.96 ~ 4.62V 6 ~ 7V

9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V

Protection type : Shut down o/p voltage, re-power on to recover

57.6 ~ 67.2V

FUNCTION

OVER TEMPERATURE 5V STANDBY REMOTE CONTROL WORKING TEMP.

Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
RC+/RC- : 4 ~10V or open = power on ; 0 ~ 0.8V or short = power off -40 ~ +70 (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

IEC 60601-1:2005+A1+A2, ANSI/AAMI ES60601-1:2005+A2, CAN/CSA C22.2 No. 60601-1:2014+A2 EAC TP TC 004 approved; Design refer to BS EN/EN60335-1, BS EN/EN 62368-1(by request)

SAFETY &
EMC (Note 4)

ISOLATION LEVEL WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION

Primary-Secondary: 2×MOOP, Primary-Earth: 1×MOOP I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to BS EN/EN55011 (CISPR11) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN60601-1-2, EAC TP TC 020

MTBF

1609.5K hrs min. Telcordia SR-332 (Bellcore) ; 186.2K hrs min. MIL-HDBK-217F (25)

OTHERS NOTE

DIMENSION

199*98*38mm (L*W*H)

PACKING

0.77Kg; 18pcs/14.9Kg/0.87CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. No load power consumption<0.5W when RC+ & RC- (CN100 pin1,2) 0 ~ 8V or short. 7. Touch current was measured from primary input to DC output. 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:MSP-200-SPEC 2024-10-30

200W Single Output Medical Type

MSP-200 series

7

98

85.5

18 9.5 3.5 28.5 38

Mechanical Specification
(Unit: mm , tolerance ± 1mm)

Case No.902E
197

9

3.5

3-M3
3.5 15 26

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment

1

AC/L

4,5 DC OUTPUT -V

2

AC/N

6,7 DC OUTPUT +V

3

FG

Connector Pin No. Assignment (CN100) :

HRS DF11-6DP-2DS or equivalent

Pin No. Assignment Mating Housing Terminal

1

RC+

2

RC-

3

AUX

HRS DF11-6DS HRS DF11-**SC

4

AUXG

or equivalent or equivalent

5

+S

6

-S

8.2

9.5

9 18.5

1

2

3

4

5

6

7



LED

3.5

CN100

SVR1

4.5

57.5

6.5

13max. 28

80

4-M3 120
199 190
150.75

Block Diagram

EMI

I/P

FILTER

FG

Derating Curve

ACTIVE INRUSH CURRENT LIMITING

RECTIFIERS &
PFC
O.T.P.
PFC CONTROL

AUX POWER
POWER SWITCHING
O.L.P.

RECTIFIERS &
FILTER
RECTIFIERS &
FILTER
DETECTION CIRCUIT

PWM fosc :70KHz
AUX AUXG +S +V
-V -S

PWM

O.V.P.

CONTROL

REMOTE

RC+

CONTROL

RC-

Output Derating VS Input Voltage

LOAD (%) LOAD(%)

112050

100

90

80 80

60

70

60 40
50 20
40

-40

0

10

20

30

40

50

60

70 (HORIZONTAL)

85

100

125

135

155

264

AMBIENT TEMPERATURE ()

INPUT VOLTAGE (V) 60Hz

File Name:MSP-200-SPEC 2024-10-30

200W Single Output Medical Type

MSP-200 series

Function Description of CN100

Pin No. Function Description

1

RC+ Turns the output on and off by electrical or dry contact between pin 2 (RC-). Short: Power OFF, Open: Power ON.

2

RC- Remote control ground.

3

AUX

Auxiliary voltage output, 4.75~5.25V, reference to pin 4(AUXG). The maximum load current is 0.3A. This output has the built-in oring diodes and is not controlled by the "remote ON/OFF control".

4 AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).

5

+S

Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.

6

-S

Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.

Function Manual

1.Remote Control The PSU can be turned ON/OFF by using the "Remote ON/OFF" function

Between RC-(pin2) and RC+(pin1) Output Status

SW ON (Short)

OFF

SW OFF (Open)

ON

-V -V +V +V CN100
1 3 5 2 4 6

CN100
1 RC+ AUX +S 5 SW
2 RC- AUXG -S 6

2.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V.

LOAD -+
Fig 1.1

-V -V +V +V CN100
1 3 5 2 4 6

-S LOAD +S

(Pin6)

(Pin5)

-+

Sense lines should be twisted in pairs

Fig 2.1

CN100 1 RC+ AUX +S 5 2 RC- AUXG -S 6

File Name:MSP-200-SPEC 2024-10-30



References

Acrobat Distiller 9.0.0 (Windows)