Everstein SFS1036 Installation Manual
Model: SFS1036
Important Notice
Important: Please read this manual carefully before installation.
- Ensure the pipes are clear and flush or blow out debris before installation to prevent blockages.
- For installation videos, scan the QR code on the instruction manual.
- Ensure all parts are included before starting the assembly.
- For replacement parts, please contact Everstein using the information in the footer.
Lifetime Limited Warranty
Everstein provides a Lifetime Limited Warranty for its shower systems, covering defects in material or manufacturing workmanship for the original purchaser. Proof of purchase is required.
In case of manufacturing defects, Everstein will, at its option, replace the defective part or product free of charge, or refund the original purchase price within 30 days of delivery.
Everstein recommends installation by a licensed professional plumber. Everstein is not responsible for any damage or failure caused by improper installation, misuse, or failure to use a licensed professional.
Warranty Coverage Exclusions:
This warranty does not cover defects or damage caused by the use of non-Everstein original parts. Furthermore, any damage resulting from faulty installation, product abuse, improper use, or the use of abrasive cleaners or solvents is not covered. Labor charges and/or damage incurred during installation, repair, or replacement are also not the responsibility of Everstein.
Limitations of Liability:
This warranty replaces all other warranties, conditions, and guarantees, whether expressed or implied, statutory or otherwise, including but not limited to merchantability or suitability. In certain states, provinces, and countries, the exclusion or limitation of incidental or consequential damages may not apply.
Responsibilities of Others:
The installer or building contractor is responsible for inspecting the unit prior to installation to ensure it is free of defects or damage. If a problem is found, the unit must not be installed. Everstein is not responsible for failures or damage that could have been discovered, repaired, or avoided by proper inspection and testing prior to installation.
Damage occurring in transit is the responsibility of the carrier. The user or installer must open the crate and inspect the unit for damage when delivered. If damage is discovered, it must be reported immediately to Everstein and the carrier in writing.
Warranty Service Note:
When requesting warranty service, please have the following ready:
- Copy of original invoice
- Date of installation
- Description and pictures of the defect
- Model number or description of the model
To obtain warranty service and replacement parts, please contact the Everstein Customer Service Team.
Content
1.2-function Rain Shower System (Pages 1-7)
CONTENIDO
1.Sistema de Ducha de Lluvia de 2 Funciones (Páginas 8-14)
Installation and Maintenance Matters
Do's:
- Check the accessories list to verify that all parts are complete in this package.
- Do not disassemble the main body by yourself.
- Connect inlet pipes to supply valves.
- Make sure inlet pipes and supply valves have no impurities and are cleaned, with no impurities in the pipeline.
- After installation, check all joints for leakages.
- Do not leave the rain shower system exposed to a severely corrosive environment.
- To keep the mixer surface bright, please clean the mixer regularly.
- Rinse the faucet with clean water and wipe it with a soft cotton cloth.
- Use one of the following cleaners to remove dirt from the surface: a. Mild liquid cleaner. b. Colorless glass cleaner and powder cleaner that do not cause abrasion and can be dissolved completely. c. Polish liquid that does not cause abrasion.
Don'ts:
- Avoid using cleaning powder, harsh cleaning brushes, and coarse cloth to prevent scratching and friction.
- Do not use acid cleaners to clean the faucet as they may cause surface corrosion. If the faucet is exposed to harmful acid substances, please rinse it immediately with water.
Tools Needed:
[Screwdriver], [Allen Wrench], [Wrench], [Pipe Fitting], [Teflon Tape], [Blow Torch]
Two-function Rain Shower System - Accessories List
Diagram: An illustration shows various components of the shower system labeled with numbers 1 through 18.
No. |
Part Name |
Qty |
No. |
Part Name |
Qty |
1 |
Shower head |
1 |
10 |
Lifting rod |
1 |
2 |
Shower arm |
1 |
11 |
Connector |
1 |
3 |
Shower arm cup |
1 |
12 |
Cup |
1 |
4 |
Main body |
1 |
13 |
Main body spare parts |
4 |
5 |
Deck plate |
1 |
14 |
Instruction manual |
1 |
6 |
Handle |
1 |
15 |
Gloves |
2 |
7 |
Handle cap |
1 |
16 |
Handle wrench |
1 |
8 |
Shower hand |
1 |
17 |
Lifting rod parts |
1 set |
9 |
Shower hose |
1 |
18 |
|
|
Essential Dimensions & Water Pipe Line
Diagram: Shows the overhead shower setup with dimensions for the shower head, arm, and connector, indicating hot and cold water inlets.
Unit: mm/inch
Dimensions:
- Shower head to connector height: 7 7/8" - 9 13/16" (200-250mm)
- Overall height range: 43 5/16" - 51 3/16" (1100-1300mm)
- Shower arm to top height range: 47 1/4" - 59" (1200-1500mm)
Connector size of male thread: USA: 1/2"-14NPT, Canada: 1/2"-14NPT, Europe: G1/2".
The Installation Depth of Shower Holder and Shower Head
Diagram: Illustrates the depth of the shower holder and shower head installation into the tile wall and dry wall.
- Connector depth into tile wall: 20mm (3/4")
- Shower arm depth into tile wall: 23mm (7/8")
The thickness of the tile must be calculated for installation.
Installation Depth Of Main Body
Diagram: Shows the main body installation depth into a tile wall and dry wall.
- Minimum depth: 2 3/16" (55mm)
- Maximum depth: 3 1/8" (80mm)
Notice:
- The installation depth of the main body should be no less than 2 9/16" (65mm) and no more than 2 15/16" (75mm), including the thickness of the tile. Otherwise, the deck plate cannot be installed.
- The opening size of ceramic tile shall be smaller than the deck plate size.
Piping Instructions Before Tiling
Diagram: Illustrates the NPT 1/2" inlet and outlet pipes for hot water, cold water, and mixed water.
Instructions:
- As shown in the figure, the inlet and outlet pipes are pre-buried. Please pay attention to the correct direction when installing the pre-buried main body.
- Before tiling, turn on the water to test whether the left and right inlet pipes are tightly connected without leakage. Then, adjust the flow switch to the "on" position to check for leaks in the mixed outlet pipes.
Main Body Valve Installation
Step 1
Diagram: Shows drilling anchors into a concrete wall or using screws for a wood wall to mount the main body valve.
- Make marks according to the size of the main body valve, and then drill anchors into the wall (concrete wall).
- Lock the main body to wood directly with screws (wood wall).
- When installing the main body, please mark the UP side up and do not install it upside down.
Note: The level meter should be parallel to the wall; otherwise, the deck plate cannot be installed.
Step 2
Diagram: Shows attaching the deck plate, water diverter, and handle.
Attention: Please adjust the constant temperature baffle plate to the lower part when installing the handle.
Precautions for handwheel installation: Do not remove the white wear ring; otherwise, the handwheel will be damaged.
- Use Main body spare parts to fix the Main body on the wall and then install the deck plate.
- Please fix the main body to the wall and install the deck plate, water diverter screw, and water diverter cap step by step.
- Install the handle with the screw and handle cap.
Water Discharge Function Introduction
Diagram: Shows the control panel with labels for Rainfall Water Outlet, Hand Shower Water Outlet, and temperature controls (C/H).
- When the handwheel points to "OFF," the water flow is turned off.
- Turning the handwheel to the left opens the overhead shower, adjusting gradually from cold to hot water.
- Turning the handwheel to the right opens the tap, adjusting gradually from cold to hot water.
The Installation of the Shower head
Diagram: Illustrates connecting the shower arm to the riser and the shower head to the shower arm.
- Connect the shower arm with the cover before screwing the arm into the riser connection to prevent damage.
- Fix the shower head onto the shower arm and apply tape to pipe threads on both ends.
- Do not overtighten the shower head. It has a 360° swivel connection.
Lifting Rod Installation
Diagram: Six steps illustrate the installation of the lifting rod, including drilling holes, attaching the base, and mounting the rod.
- Mark the punch position with a pen, drill holes using a 6 mm electric drill, then knock the pellets in. Lastly, place the base and screw in the screws.
- Put the Shower Elevator Rack into the base, then tighten the screw. Done.
- Step 1: Wrap the connector with Teflon tape. Screw the thread into the water pipe inside the wall.
- Step 2: Install the rubber pad on the shower hose and connect it to the connector.
Instalación y Cuestiones de Mantenimiento
Hacer:
- Verifique la lista de accesorios para comprobar que todas las partes están completas en este paquete.
- No desmonte el cuerpo principal por sí mismo.
- Conecte las tuberías de entrada a las válvulas de suministro.
- Asegúrese de que las tuberías de entrada y las válvulas de suministro no tengan impurezas y estén limpias, sin impurezas en la tubería.
- Después de la instalación, verifique todas las uniones para detectar fugas.
- No deje el sistema de ducha tipo lluvia expuesto a un ambiente severamente corrosivo.
- Para mantener la superficie del mezclador brillante, limpie el mezclador regularmente.
- Enjuague el grifo con agua limpia y límpielo con un suave paño de algodón.
- Utilice uno de los siguientes limpiadores para eliminar la suciedad de la superficie: a. Limpiador líquido suave. b. Limpiador de vidrio incoloro y limpiador en polvo que no causen abrasión y que se puedan disolver completamente. c. Líquido pulidor que no cause abrasión.
No hacer:
- Evite usar polvo de limpieza, productos químicos de limpieza duros, cepillos y tela gruesa para evitar rascar y fricción.
- No use limpiadores de ácidos para limpiar el grifo, ya que pueden causar corrosión superficial del grifo. Si el grifo está expuesto a sustancias ácidas dañinas, enjuague inmediatamente con agua.
Herramientas Necesarias:
[Destornillador], [Llave Allen], [Llave Inglesa], [Conector de Tubería], [Cinta de Teflón], [Soplete]
Grifo de ducha con botón de 2 funciones - Lista de Accesorios
Diagrama: Muestra varios componentes del sistema de ducha etiquetados con números del 1 al 18.
N.° |
Nombre de la pieza |
Cant. |
N.° |
Nombre de la pieza |
Cant. |
1 |
Cabezal de ducha |
1 |
10 |
Barra de elevación |
1 |
2 |
Brazo de ducha |
1 |
11 |
Conector |
1 |
3 |
Copa del brazo de ducha |
1 |
12 |
Taza |
1 |
4 |
Cuerpo principal |
1 |
13 |
Piezas de repuesto del cuerpo principal |
4 |
5 |
Placa de cubierta |
1 |
14 |
Manual de instrucciones |
1 |
6 |
Manija |
1 |
15 |
Guantes |
2 |
7 |
Tapa de la manija |
1 |
16 |
Llave de manija |
1 |
8 |
Ducha de mano |
1 |
17 |
Piezas de la barra de elevación |
1 juego |
9 |
Manguera de ducha |
1 |
18 |
|
|
Dimensiones Esenciales y Línea de Tubería de Agua
Diagrama: Muestra la configuración de la ducha superior con dimensiones para el cabezal de ducha, brazo y conector, indicando las entradas de agua caliente y fría.
Unidad: mm/pulgada
Dimensiones:
- Altura del cabezal de ducha al conector: 7 7/8" - 9 13/16" (200-250mm)
- Rango de altura total: 43 5/16" - 51 3/16" (1100-1300mm)
- Rango de altura del brazo de ducha a la parte superior: 47 1/4" - 59" (1200-1500mm)
Tamaño del conector de rosca macho: EE. UU.: 1/2"-14NPT, Canadá: 1/2"-14NPT, Europa: G1/2".
La Profundidad de Instalación del Soporte de Ducha y del Cabezal de Ducha
Diagrama: Ilustra la profundidad de la instalación del soporte y cabezal de ducha en la pared de azulejos y pared seca.
- Profundidad del conector en la pared de azulejos: 20mm (3/4")
- Profundidad del brazo de ducha en la pared de azulejos: 23mm (7/8")
El grosor del azulejo debe ser calculado para la instalación.
Profundidad de Instalación del Cuerpo Principal
Diagrama: Muestra la profundidad de instalación del cuerpo principal en una pared de azulejos y pared seca.
- Profundidad mínima: 2 3/16" (55mm)
- Profundidad máxima: 3 1/8" (80mm)
Aviso:
- La profundidad de instalación del cuerpo principal no debe ser inferior a 2 3/16" (55 mm) y no más de 3 1/8" (80 mm), incluyendo el grosor del azulejo. De lo contrario, la placa de cubierta no podrá ser instalada.
- El tamaño de apertura del azulejo cerámico debe ser menor que el tamaño de la placa de cubierta.
Instrucciones de Tubería Antes de Colocar Azulejos
Diagrama: Ilustra las tuberías de entrada y salida NPT 1/2" para agua caliente, agua fría y agua mixta.
Instrucciones:
- Como se muestra en la figura, las tuberías de entrada y salida están pre-enterradas. Por favor, preste atención a la dirección correcta al instalar el cuerpo principal pre-enterrado.
- Antes de colocar los azulejos, abra el agua para probar si las tuberías de entrada izquierda y derecha están conectadas herméticamente sin fugas. Luego, ajuste el interruptor de flujo a la posición "on" para comprobar si hay fugas en las tuberías de salida mezcladas.
Instalación de la Válvula del Cuerpo Principal
Paso 1
Diagrama: Muestra la perforación de anclajes en una pared de concreto o el uso de tornillos para una pared de madera para montar la válvula del cuerpo principal.
- Marque según el tamaño de la válvula del cuerpo principal y luego perfore para colocar los anclajes en la pared (pared de concreto).
- Fije directamente el cuerpo principal a la madera con tornillos (pared de madera).
- Al instalar el cuerpo principal, por favor marque el lado UP hacia arriba y no lo instale al revés.
Nota: Tenga en cuenta que el nivel debe estar paralelo a la pared; de lo contrario, la placa de cubierta no podrá ser instalada.
Paso 2
Diagrama: Muestra la fijación de la placa de cubierta, el desviador de agua y la manija.
Atención: Ajuste la placa deflectora de temperatura constante a la parte inferior cuando esté instalando la manija.
Precauciones para la instalación de la rueda manual: No retire el anillo blanco de desgaste; de lo contrario, la rueda manual se dañará.
- Use las piezas de repuesto del cuerpo principal para fijar el cuerpo principal en la pared y luego instale la placa de cubierta.
- Por favor, fije el cuerpo principal a la pared e instale la placa de cubierta, el tornillo del desviador de agua y la tapa del desviador de agua paso a paso.
- Instale la manija con el tornillo y la tapa de la manija.
Introducción a la Función de Descarga de Agua
Diagrama: Muestra el panel de control con etiquetas para Salida de Agua en Forma de Lluvia, Salida de Agua de la Ducha de Mano y controles de temperatura (C/H).
- Cuando la rueda manual apunta a "OFF", el flujo de agua se cierra.
- Girar la rueda manual hacia la izquierda abre la ducha superior, ajustando gradualmente de agua fría a caliente.
- Girar la rueda manual hacia la derecha abre el grifo, ajustando gradualmente de agua fría a caliente.
La Instalación del Cabezal de Ducha
Diagrama: Ilustra la conexión del brazo de ducha a la tubería vertical y del cabezal de ducha al brazo de ducha.
- Conecte el brazo de la ducha con la cubierta antes de atornillar el brazo en la conexión del elevador para evitar daños.
- Fije el cabezal de ducha al brazo de ducha y aplique cinta a las roscas de la tubería en ambos extremos.
- No apriete demasiado el cabezal de ducha. Es una conexión giratoria de 360°.
Instalación de la Barra de Elevación
Diagrama: Seis pasos ilustran la instalación de la barra de elevación, incluyendo la perforación de agujeros, la fijación de la base y el montaje de la barra.
- Marque la posición del golpe con un bolígrafo, perforaciones con un taladro eléctrico de 6 mm, golpe Los gránulos en finalmente, colocan la base y atornille los tornillos.
- Ponga la rejilla del ascensor de la ducha en la base, luego apriete el tornillo, hecho.
- Paso 1: El conector se envolverá con cinta de teflón, atornille la rosca en el agua tubería dentro de la pared.
- Paso 2: Instale la almohadilla de goma en la manguera de ducha y conéctela con el conector.
Models: SFS1036 2 Spray Wall Mount Shower Head, SFS1036, 2 Spray Wall Mount Shower Head, Wall Mount Shower Head, Mount Shower, Head