User Guide for Danfoss models including: LE402 Logic Element Normally Closed Spool Type Pilot Valve Adapter, LE402, Logic Element Normally Closed Spool Type Pilot Valve Adapter, Normally Closed Spool Type Pilot Valve Adapter, Spool Type Pilot Valve Adapter, Pilot Valve Adapter, Valve Adapter, Adapter

ICS Logic Elements LE402 Technical Information

LE402

Logic Elements for Hydraulic Integrated Circuits | Danfoss | Danfoss

PDF preview unavailable. Download the PDF instead.

BC479481219665en-000101
Logic Elements
LE402
Logic Element, Normally Closed, Spool Type, Pilot Valve Adapter 350 bar [5000 psi] · 350 l/min [93 US gpm]
DESCRIPTION AND OPERATION This is a high flow, 2-port logic element where a pilot control valve can be installed into the cavity on the top of the valve. The valve is normally closed from port 1 to 2, with an orifice through the spool connecting port 1 to the inlet port 1 of the control valve. Installing a direct acting relief valve will make this valve a high flow relief valve, a solenoid valve a high flow on/off valve, and a proportional control valve a high flow proportional control valve.

SCHEMATIC

1

2

DIMENSIONS

mm [in]

25.0

(0.98)

max

Cavity SDC08-2

26.0 A/F

1-5/8-12UN-2A

Pressurep - psi Pressure - bar

58.5
(2.30) Tank (2)

PERFORMANCE DATA
Rated pressure Rated flow Pilot Valve Cavity Leakage Weight Cavity

MODEL CODE

Basic Code
LE402 -No housing LE452- Cartridge and housing

Seal Option

Code

Seal Kit

N-Buna-N SK633

V- Viton SK633V

Spring Bias 0.2 - 2 bar [29 psi]

Pilot cartridge
Omit - None 1DR2-P-40S PDR21AN*6** S207N

BC479481219665en-000101

350 bar [5000 psi] 350 l/min [93 US gpm]
SDC08-2 350 ml/min nominal
0.29 kg [0.63 lb] SDC20-2

Installation torque 60 Nm [44 ft lbs]

Pressure (1)

PERFORMANCE CURVES

Pressure Drop

0 30 145

Flow - L/min 90 150 210

270 10

116

8

87

6

58

4

29

2

0

0

0 8

24

40

56

72

Free Flow 1 to 2 Flow - US gpm

LE452 - N - 0.2 - 1DR2-P-40S - 10W - 377

Housing Material
Omit-Aluminum/No housing 377 - Steel

Housing

Code

Ports Aluminum Steel

Omit No housing 10W 1-1/4" BSP C24005 12W 1-1/2" BSP C24007 20T 1-1/4" SAE C24011 24T 1-1/2" SAE C24013

C24006 C24008 C24012 C24014

* Aluminum bodies are to be used for pressures less than 210 bar [3000 psi]. * Additional housings available

