Digital Tap Timer User Guide CO1605 www.holmanindustries.com.au GLOSSARY A. UNIVERSAL TAP ADAPTOR B. TAP CONNECTION C. UNION NUT D. LCD DISPLAY E. CONTROL BUTTONS F. BATTERY COMPARTMENT G. CLEAR SCREW-ON COVER H. SNAP-ON HOSE CONNECTION A B C G H D E F MANUAL WATERING TECHNICAL DATA PRODUCT: Low Pressure Tap Timer

PDF preview unavailable. Download the PDF instead.

CO1605
Digital Tap Timer

BATTERY INSTALLATION

1. Hold the tap timer with the battery compartment facing you

2. Remove the battery compartment tray

3. Connect a 9V ALKALINE battery to the battery connector

4. Insert the connected battery and push in the battery tray

E

 When changing a battery, the timer will hold the current program if you fit the battery within 2 minutes. When changing the battery, make sure the battery compartment stays dry

 Use only 9V ALKALINE batteries

SETTING THE WATERING DAYS SETTING THE START TIMES

Undo-Alt

Undo-Alt

'DAYS' is where you select what day(s) you want to water on
1. Press until the calendar is displayed on the left next to 'DAYS'. This means your are in 'DAY' mode
2. Press ARROW-CI and the black box under 'M' will flash
3. Press PLUS-CIR to select that day, press Minus-Ci to deselect that day
4. Press ARROW-CI to scroll through the days, press PLUS-CIR if you need to reselect that day
5. Press to save the schedule

Undo-Alt

'STARTS' is the time of day you want your watering to begin. You can schedule up to 4 start times per day
1. Press until the alarm clock is displayed in the bottom left corner next to 'STARTS'. This means you are in 'STARTS' mode
2. Start '1' is the time you want your watering to first begin. Use PLUS-CIR or Minus-Ci to adjust the hour
3. Press ARROW-CI then PLUS-CIR or Minus-Ci to adjust the minutes

MANUAL WATERING
OPTION 1: Manual Watering
To start Manual Watering, turn the `INTERVAL' dial to `RESET'. Turn the `RUN TIME' dial to `ON'. Turn on your tap and water as needed. To stop watering, turn your tap off. Turn the `RUN TIME' dial to `OFF', or re-enter the watering operation

OPTION 2: Manual Watering (Auto-Stop)
To start Manual Watering with an auto-stop, turn the `INTERVAL' dial to `RESET'. Turn the `RUN TIME' dial to the desired time you wish to water for. Turn on your tap, watering will stop once `RUN TIME' minutes have lapsed

INTERVAL

RUN TIME

INTERVAL

RUN TIME

ENTER

ENTER

CO1605

www.holmanindustries.com.au

User Guide

GLOSSARY A. UNIVERSAL TAP ADAPTOR B. TAP CONNECTION C. UNION NUT D. LCD DISPLAY E. CONTROL BUTTONS F. BATTERY COMPARTMENT G. CLEAR SCREW-ON COVER H. SNAP-ON HOSE CONNECTION
INSTALLATION
Make sure the washer is in place, then screw the Tap Timer to the tap. Turn it clockwise (hand tighten only)
 There should be no need to use thread seal tape, as long as the tap seals onto the washer
SETTING THE CURRENT TIME

A D
E F

B C
G H

SETTING THE DURATION

Undo-Alt

Undo-Alt

1. Press until the clock is displayed in the top left corner next to `TIME'. This means you are in `TIME' mode
2. Press ARROW-CI and the hour will flash 3. Press PLUS-CIR or Minus-Ci to adjust the hour 4. Press ARROW-CI to select the minutes 5. Press PLUS-CIR or Minus-Ci to adjust the minutes 6. Press ARROW-CI to select the day (the
black box will be flashing) 7. Press PLUS-CIR to reach the current
day. Press ARROW-CI to save the day
4. Press to change to the next start time and repeat steps 2 and 3
5. To turn a start time 'OFF' adjust the 'HOUR' until it reads 'OFF'
MANUAL OPERATION
'MANUAL' allows you to manually turn on your tap timer and set a watering duration.  This will not effect your
automatic schedule.

Undo-Alt

'DURATION' is the length of time you want the water to run for
1. Press until the hour glass is displayed on the left next to 'DURATION'.This means you are in 'DURATION' mode
2. The hour display will be flashing, press PLUS-CIR or Minus-Ci to adjust the hour
3. Press ARROW-CI to select the minutes 4. Press PLUS-CIR or Minus-Ci to adjust the minutes
MANUAL OPERATION CONT.
1. Press - to begin manual watering. The pre-set time is 10 minutes. This will start automatically unless the duration is changed
2. Manually set the duration time using - or -
3. Once the watering duration has finished the tap timer will automatically end watering and return to the automatic schedule
SUSPENDING OPERATION
Use this feature when you want to temporarily suspend the automatic schedule. This feature is generally used when it has been raining or during winter.
Suspension: Press w

TECHNICAL DATA
PRODUCT: Low Pressure Tap Timer
PRODUCT CODE: CO1603
MAXIMUM WATER PRESSURE: 600 kPa
BATTERY: Use 2 x AAA ALKALINE batteries
FLUID: Only use cold water with NO added chemicals
FREQUENCY OPTIONS: Every 1 hrs, 2 hrs, 3 hrs, 4 hrs, 6 hrs, 8 hrs, 12 hrs, 24 hrs, 48 hrs, 72 hrs, Week, Reset
RUN TIME OPTIONS: 1, 3, 5, 10, 15, 20, 30, 60, 90, 120, ON, OFF
WARNINGS: Do not use this device without the appropriate filter
Every 4 seconds the LED will flash to confirm the battery is working. If the LED flashes any quicker, please replace the batteries

We really appreciate having you as a customer, and would like to say thank you for choosing us. Should you have any questions
about this product or its operation please call customer service on 1300 716 188
Head Office/Service 11 Walters Drive, Osborne Park WA 6017 Tel: +61 8 9416 9999 Fax: +61 8 9416 9920 support@holmanindustries.com.au
www.holmanindustries.com.au
Copyright © 2020 Holman Industries


Adobe PDF Library 15.0 Adobe InDesign 15.1 (Macintosh)