User Guide for HOLMAN models including: CO1605, Digital Tap Timer
PRODUCT: Low Pressure Tap Timer. PRODUCT CODE: CO1603. MAXIMUM WATER PRESSURE: 600 kPa. BATTERY: Use 2 x AAA ALKALINE batteries. FLUID: Only use cold water.
Digital Tap Timer User Guide CO1605 www.holmanindustries.com.au GLOSSARY A. UNIVERSAL TAP ADAPTOR B. TAP CONNECTION C. UNION NUT D. LCD DISPLAY E. CONTROL BUTTONS F. BATTERY COMPARTMENT G. CLEAR SCREW-ON COVER H. SNAP-ON HOSE CONNECTION A B C G H D E F MANUAL WATERING TECHNICAL DATA PRODUCT: Low Pressure Tap Timer
Digital Tap Timer BATTERY INSTALLATION 1. Hold the tap timer with the battery compartment facing you 2. Remove the battery compartment tray 3. Connect a 9V ALKALINE battery to the battery connector 4. Insert the connected battery and push in the battery tray E When changing a battery, the timer will hold the current program if you fit the battery within 2 minutes. When changing the battery, make sure the battery compartment stays dry Use only 9V ALKALINE batteries SETTING THE WATERING DAYS SETTING THE START TIMES Undo-Alt Undo-Alt 'DAYS' is where you select what day(s) you want to water on 1. Press until the calendar is displayed on the left next to 'DAYS'. This means your are in 'DAY' mode 2. Press ARROW-CI and the black box under 'M' will flash 3. Press PLUS-CIR to select that day, press Minus-Ci to deselect that day 4. Press ARROW-CI to scroll through the days, press PLUS-CIR if you need to reselect that day 5. Press to save the schedule Undo-Alt 'STARTS' is the time of day you want your watering to begin. You can schedule up to 4 start times per day 1. Press until the alarm clock is displayed in the bottom left corner next to 'STARTS'. This means you are in 'STARTS' mode 2. Start '1' is the time you want your watering to first begin. Use PLUS-CIR or Minus-Ci to adjust the hour 3. Press ARROW-CI then PLUS-CIR or Minus-Ci to adjust the minutes MANUAL WATERING OPTION 1: Manual Watering To start Manual Watering, turn the `INTERVAL' dial to `RESET'. Turn the `RUN TIME' dial to `ON'. Turn on your tap and water as needed. To stop watering, turn your tap off. Turn the `RUN TIME' dial to `OFF', or re-enter the watering operation OPTION 2: Manual Watering (Auto-Stop) To start Manual Watering with an auto-stop, turn the `INTERVAL' dial to `RESET'. Turn the `RUN TIME' dial to the desired time you wish to water for. Turn on your tap, watering will stop once `RUN TIME' minutes have lapsed INTERVAL RUN TIME INTERVAL RUN TIME ENTER ENTER CO1605 www.holmanindustries.com.au User Guide GLOSSARY A. UNIVERSAL TAP ADAPTOR B. TAP CONNECTION C. UNION NUT D. LCD DISPLAY E. CONTROL BUTTONS F. BATTERY COMPARTMENT G. CLEAR SCREW-ON COVER H. SNAP-ON HOSE CONNECTION INSTALLATION Make sure the washer is in place, then screw the Tap Timer to the tap. Turn it clockwise (hand tighten only) There should be no need to use thread seal tape, as long as the tap seals onto the washer SETTING THE CURRENT TIME A D E F B C G H SETTING THE DURATION Undo-Alt Undo-Alt 1. Press until the clock is displayed in the top left corner next to `TIME'. This means you are in `TIME' mode 2. Press ARROW-CI and the hour will flash 3. Press PLUS-CIR or Minus-Ci to adjust the hour 4. Press ARROW-CI to select the minutes 5. Press PLUS-CIR or Minus-Ci to adjust the minutes 6. Press ARROW-CI to select the day (the black box will be flashing) 7. Press PLUS-CIR to reach the current day. Press ARROW-CI to save the day 4. Press to change to the next start time and repeat steps 2 and 3 5. To turn a start time 'OFF' adjust the 'HOUR' until it reads 'OFF' MANUAL OPERATION 'MANUAL' allows you to manually turn on your tap timer and set a watering duration. This will not effect your automatic schedule. Undo-Alt 'DURATION' is the length of time you want the water to run for 1. Press until the hour glass is displayed on the left next to 'DURATION'.This means you are in 'DURATION' mode 2. The hour display will be flashing, press PLUS-CIR or Minus-Ci to adjust the hour 3. Press ARROW-CI to select the minutes 4. Press PLUS-CIR or Minus-Ci to adjust the minutes MANUAL OPERATION CONT. 1. Press - to begin manual watering. The pre-set time is 10 minutes. This will start automatically unless the duration is changed 2. Manually set the duration time using - or - 3. Once the watering duration has finished the tap timer will automatically end watering and return to the automatic schedule SUSPENDING OPERATION Use this feature when you want to temporarily suspend the automatic schedule. This feature is generally used when it has been raining or during winter. Suspension: Press w TECHNICAL DATA PRODUCT: Low Pressure Tap Timer PRODUCT CODE: CO1603 MAXIMUM WATER PRESSURE: 600 kPa BATTERY: Use 2 x AAA ALKALINE batteries FLUID: Only use cold water with NO added chemicals FREQUENCY OPTIONS: Every 1 hrs, 2 hrs, 3 hrs, 4 hrs, 6 hrs, 8 hrs, 12 hrs, 24 hrs, 48 hrs, 72 hrs, Week, Reset RUN TIME OPTIONS: 1, 3, 5, 10, 15, 20, 30, 60, 90, 120, ON, OFF WARNINGS: Do not use this device without the appropriate filter Every 4 seconds the LED will flash to confirm the battery is working. If the LED flashes any quicker, please replace the batteries We really appreciate having you as a customer, and would like to say thank you for choosing us. Should you have any questions about this product or its operation please call customer service on 1300 716 188 Head Office/Service 11 Walters Drive, Osborne Park WA 6017 Tel: +61 8 9416 9999 Fax: +61 8 9416 9920 support@holmanindustries.com.au www.holmanindustries.com.au Copyright © 2020 Holman IndustriesAdobe PDF Library 15.0 Adobe InDesign 15.1 (Macintosh)